Dismantling of existing broken CC Collar in Street Light Poles and Re-Construction of New Collars in Area Ward No. 19, 20, 21, 22, 33, 34, 35 under Sub Division No. 3, M.C. Chandigarh
2025_MCC_89789_1
71/E/MCC/2025
Open Tender
Electrical Works
60 days
Dismantling of existing broken CC Collar in Street
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹3,970
10 Apr 2026
30 Dec 2025
9 Jan 2026
30 Dec 2025
9 Jan 2026
30 Dec 2025
S/E of CC Collars including following:- a) The box shall be enclosed in a cement collar made from cement concrete 1:2:4 with outside dia 16”. b) The collar shall be embedded in the group upto 6” shall stand 9” above ground shall have housed 12” high SMC Box and 6” top over the box. c) The collar shall be provided with 2 G.I. Pipe of 40mm dia and 45cm long to facilitate entry of cables in the junction box after digg out the cable loops from earth complete in all respects, connections etc. d) The collar shall be plastered properly finished, curing and painted with 2 coats of Apex paint of superior quality. e) Providing and Fixing junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement. The existing ckt cable loops be made properly connection after digging from the earth and refilling the same position. There should be a terminal Strip (Thimble type) 30 amp, one no. Kitkat, rating suitable for minimum 4x16 sq.mm aluminum cable termination. The sheath of the armoured cable should be properly thimbed with the pole for proper earthing. Curing of CC Collar must be done as per satisfaction of Engineer-in-charge. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect.
Dismantling of existing damaged/broken old bollard lights/CC Collar, Jallies alongwith junction box, wire and C.C. foundation etc. and other material complete in all respect to the satisfaction of Engg-in-charge. The entire “malba” shall be disposed off and send to C & D plant Industrial Area Phase-I. The contractor shall hand over the dismantled material to the J.E-in-Charge at central store in proper form duly accounted.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_109820.pdf
BOQ Comparative Chart
xlsx
finsummary_109820.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.26 MB
BOQ_109820.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid