| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹39.4 L+₹78,164 (2.02%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹39.5 L+₹86,459 (2.24%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.2 L+₹1.6 L (4.06%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.5 L+₹2.8 L (7.31%)Rejected-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L5 | Rejected-AOC Rejected |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
7 Jun 2023, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam
REPAIRS TO PERIMETER STREET LIGHTS WATCH TOWER FLOOD AND SOLAR LIGHTS INCLUDING CONNECTED ITEMS UNDER GE M RAJALI ARAKKONAM
2023_MES_596259_1
8270E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer M NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹78,000
Yes
15 Jul 2023
17 May 2023
9 Jun 2023
17 May 2023
7 Jun 2023
31 May 2023
Amount
Taking down unserviceable solar light fittings of any watt and type from existing position on pole/wall for repair keep in safe costody for refix serviceable light fittings after repair all as specified and as directed Note: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘ Supply only’ under relavent item here-in-after ii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fitting are deemed to be included in the quoted rate.
Refixing serviceable solar light fitting in existing position after repair of any watt and type on existing pole complete all as specified and as directed
Supply and fixing in repair of Solar LED street light luminaire complete suitable for solar street light DC supply of not less than 35 Watt with LED driver and auto dusk and dawn off control, IP65 outdoor type in and including all necessary new wiring with 1.5 sqmm copper for PV panel, battery, MCB,including S & F charge controller as per site for making functioning of LED on solar light on existing stand alone solar system, servicing, cleaning of PV panel complete, testing and commissioning complete all as specified and as directed by Engr-in-charge. Make LUKER Cat LSTSOL30N or equivalent modal of crompton /Surya/Philips Note: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS work as per site requirement.
Supply only outdoor drivers any type not less then 35 wattage for Havells solar lights including necessary connecting arrangements as per site requirement all as specified and directed.
Material and Labour for servicing, overhauling, caliberation, conditioning, repairing, cleaning to old/ unserviceable PV cell system, charge controller system complete of stand alone solar street light system as per site requirement to make functioning of PV cell system incl taking down unserviceable solar PV Cell panels of any watt and type from existing position on pole/wall for repair , complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable LED light fittings of any watt and type from existing position on pole/ wall/ tower/gate/hanger, complete for repair and keep in safe costody for refix the serviceable light fittings all as specified and as directed. Note: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘ Supply only’ under relavent item here-in-after ii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fittings are deemed to be included in the quoted rate.
Refixing the serviceable light fitting in existing position after repair of any watt and type on existing pole complete all as specified and as directed
Supply,Fixing and Testing LED street light luminaire fitting of not less than 60 Watt,Luminaire fitting of IP 66 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Surya / Philips/ Bajaj /Crompton.
Supply and Fixing and Testing LED street light luminaire fitting of not less than 45 Watt of IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Surya / Philips/ Bajaj /Crompton.
S&F out door drivers any type and 50-75 wattage after taking down old unserviceable flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all as specified and directed Make : Surya / Philips/ Bajaj /Crompton.
Supply only surge protection devicess any type and KV for 5 KV suitable for LED light fittings up to 75 watts capacity flood lights/post top latern lights including necessary connecting arrangements as per site requirement all as specified and directed. Make : Philips/Wipro/Surya/Crompton
Taking down unserviceable LED Flood light fittings of any watt and type from existing position on pole/ wall/ tower/gate/hanger, complete for repair and keep in safe costody for refix the serviceable light fittings all as specified and as directed. Note: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘ Supply only’ under relavent item here-in-after ii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fittings are deemed to be included in the quoted rate.
Refixing the serviceable light fitting in existing position after repair of any watt and type on existing pole complete all as specified and as directed
Supply,Fixing and Testing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Luminaire fitting of IP 66 protection comprises of Pressure die cast Aluminium housing powder coated,with Surge Suppressor 5 KV complete including making good disturbed surfaces all as specified and directed. Make : Surya / Philips/ Bajaj /Crompton.
Supply,Fixing and Testing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Luminaire fitting of IP 66 protection comprises of Pressure die cast Aluminium housing powder coated with Surge Suppressor 5 KV complete including making good disturbed surfaces all as specified and directed. Make : Surya / Philips/ Bajaj /Crompton.
S&F out door drivers any type and 75-150 wattage after taking down old unserviceable flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all as specified and directed Make : Surya / Philips/ Bajaj /Crompton.
Supply only surge protection devicess any type and KV for 10 KV suitable for LED light fittings up to 75-150 watts capacity flood lights including necessary connecting arrangements as per site requirement all as specified and directed. Make : Philips/Wipro/Surya/Crompton
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed.
PCC for foundation for pole/post where ever necessary 1:4:8 type D-2 (40 mm graded aggregate) complete all as specified and directed.
PCC for coping for Light pole, road cutting etc whereever necessary 1:3:6 type C-1 (20 mm graded aggregate) complete all as specified and directed.
Dismantling steel poles of any size etc from existing location/positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed.
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type type 410 SP-31 (9.00 metres long) complete all as specified and directed.
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M&L for tubes light grade galvanised iron pipes of 40 mm sizes with all fittings and fixed under road / culvert/cable protection ,complete all as specified and directed
Taking down old unservicaeble security light pole junction box/bus bar box etc from existing security light poles / wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed.
Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 55 fabricated by CPRI certified panel manufacturer's and including suitable terminal TPN 10 KA SMC Connector , MCB SPN 20 Amps 'C' curve - 01 No , hinged door with Two hinges, pad side locking system - 01 No for fixing as per site and including MS Clamps - 02 Nos of suitable shape of size 25mm width, 6 mm thick, 900mm long for cement pole with zinc coated nut, bolts and washers as per site requirement complete all as specified and directed.
M & L for black stove enamelled rigid ERW steel conduit 25 mm dia fixing with suitable size MS clamp / saddles as per site requirement complete all as specified and directed by Engr In Charge.Make :- BEC/EMCO/ GARWARE /JINDAL/ WAVIN/FINOLEX.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 3 core solid conductor nominal cross section in service connection complete all as specified and directed.
Material and labour for removing of existing loop cable from under ground, after rectificattion of fault /damaged cable portion and rearrange the cable to same existing location with proper connections including lugs, nuts, bolts including Earth work etc. complete all as specified and as directed by Engr-in-charge.
Material and labour for cutting of bituminous road/ floor for laying of pipe / cables n. exc 1.5m wide and n. exc 1.5m deep including refilling with material and watering well ramming compacting and making good with PCC 1:3:6 type B1 suitable thick complete all as specified and directed. Note-PCC shall measured and paid separately under relevant itemof schedule.
Cutting and Trimming of tree branches touching street / security poles or light fittings etc, to clear the tree branches around the pole and maintain a clearance of 1.50 M radius of the pole top or light fitting complete all as specified and as directed by Engineer-in-charge. Note:- (a) An area of 1.5 M surrounding the pole to be cleared off trees branches. (b) Measurement and payment will be made for all cutting / trimming near top of the each pole as one job only.
Dismantling and taking out following size cable from existing feeder pillar/ LT panel and removing/ cutting burned part of cable including taking out loop for extension of cable upto required length and fixing /connecting the cable in existing position including necessary nuts, bolts, lugs of approriate size and refixing of cable gland complete all as specified and as directed by Engr-in-charge for following sizes: Note: The quoted rate includes necessary earth work and supply and fixing of lugs of appropriate sizes.
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Material and labour for straight through cable heat shrinkable joint kit for 1.1 KV grade complete with jointing material and accessories like lugs etc complete suitable for following size XLPE cable all as specified and as directed.
150 sqmm 3.5 core to 185 sqmm 3.5 core
50 sqmm 3.5 core to 120 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Material and labour for end joint heat shrinkable joint kit for 1.1 KV grade complete with jointing material and accessories like lugs etc complete suitable for following size XLPE cable all as specified and as directed.
150 sqmm 3.5 core to 185 sqmm 3.5 core
50 sqmm 3.5 core to 120 sqmm 3.5 core
35 sqmm 4 core
Taking up existing old/ unserviceable/ burnt under ground cable from the existing positions/ trenches etc., including testing with the help of megger, disconnecting and removing unserviceable portion of cable complete all as specified and as directed. Note:- (i) Excavation/ earth work shall be measured and paid seprately under relavent items. (ii) Retrived serviceable bricks from site be properly stacked and reused as protection to UG cable and shall be measured and paid separetely under relevent items. (iii) Serviceable portion of cable shall be relayed as directed and shall be measured and paid separetely under relevent items.
16 sqmm 4 core,
25 sqmm 4 core,
120 sqmm 3.5 core,
Supply,laying following size of cable XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor , connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel / Street light boxes all as per site requirement , testing complete all as specified and directed.
16 sqmm 4 core,
25 sqmm 4 core,
120 sqmm 3.5 core,
Relaying serviceable portion of cable as obtained against item No 16 here-in-before in the trench including necessary connections with suitable lugs complete all as specified and directed Note:- Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
16 sqmm 4 core,
25 sqmm 4 core,
120 sqmm 3.5 core,
Supply and fixing sealed maintenance free lead acid battery 12 V, 100 AH in and including new terminals/ lugs, wiring as per site requirement complete all as specified and as directed : make Exide/ Amaron/Luminious
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft / loose soit including removing green vegetation,roots,bushes etc from surroundings near electric poles/panels or sub stations area Complete all as specified and directed.
Excavation in trenches n. exc 1.5 m deep and n. exc 1.5 m in depth for taking up / laying cable etc incl for each additional 1.5m or part thereof in depth beyond the first 1.5 and getting out for soft/loose soil complete all as specified and directed.
Spreading riddled earth for low thermal resistivity UG cable cushioning complete all as specified and directed
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed.
Relaying of serviceable bricks as obtained from item ser No.14 here-in-before complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed.
Material and labour for painting to existing LT feeder pillar box/panel boards after preparing/ scraping the surface with emery sheet in all respect for making smooth surface including painting with two coat of exterior enamel paint water proof suitable for existing LT feeder pillar box/panel board surfaces including writing in coming and out going details as per site requirement and as specified complete all as specified and as directed. Note: White washing to copping/pedestal of LT feeder pillar box / panel board shall be measured and paid separately.
Material and labour for welding works to existing LT feeder pillar box/panel board doors including removing broken hinges and supply and fixing new heavy duty hinges as per existing type and qty including writing in coming and out going details as per site requirement and painting with synthetic enamel paint over redoxide on the welded surfaces to make good the disturbed surface and match with existing tint complete all as specified and as directed.
RD ENTERPRISES
RK ENTERPRISES
Global Safety Engineering and Management Solutions
KRISHNA ENTERPRISES
SHRI S SANTHAKUMAR
RK CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .