Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST | |
| 2 | L2₹26.6 L+₹3.0 L (12.7%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹27.2 L+₹3.7 L (15.5%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹30.0 L+₹6.4 L (27.2%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹32.5 L+₹8.9 L (37.9%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹49.2 L
EMD Value
₹98,500
Closing Date
3 Jul 2023, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
CA NO GES U 12 2023 24 PROVN OF COVERED SHELTER RETAINING WALL AT DEPOT AREA RECONSTRUCTION OF BOUNDARY WALL NEAR BLDG NO P13 AT SAPPER ENCLAVE AND REWIRING OF BLDG NO NP15 OR LIVING AT MED REGT UNDER GE SOUTH UDHAMPUR
2023_MES_601216_1
GE/S(U)-12/2023-24
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹98,500
12 Sept 2023
5 Jun 2023
4 Jul 2023
5 Jun 2023
3 Jul 2023
19 Jun 2023
Amount
Excavation in post holes (or similar holes) in hard rock, each not exc 0.50 cum, getting out, removing surplus spoil to distance not exceeding 50 mtr and making good surface complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate in fdn, filling and mass concrete including complete all as specified and as directed.
Rolled Mild steel work conforming to Fe 410 W (Gde E-250 Quality B) as in single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections etc complete all as specified and as directed.
Rolled mild steel conforming to Fe 410 W (Gde E-250 Quality B) in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60mm thick crimpted/tapard at the external end slo of any colour having tensile strength 550 Mpa as in roof covering fixed with self tapping screws and caps etc complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10 cm in width or girth and applying two coats of black bituminous paint over coat of red oxide complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Earth work in excavation in any type of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed.
PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Walling of random rubble stone masonry uncoursed well bonded, bedded and solidly hearted, built in cement mortar (1:6) including providing weep holes complete all as specified and as directed. (PCC bond stone shall be measured and paid seperately)
All as per Ser Item No 11 above but except stones complete all as specified and as directed.
PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) set in cement mortar 1:6 as in bond stones of any thickness and size or shape complete all as specified and as directed.
Raised pointing to random rubble walling uncoursed in CM (1:3) complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stone and dressing of face beds and joints as specified of random rubble walling, uncoursed or brought up to course, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 20 mm for granite or trap stone complete all as specified and as directed.
Material and labour for providing precast cement concrete louvers and jallies, 50mm thick (measured solid) including all mouldings set in cement mortar 1:6 type B0 1:2:4 (Using 12.5 mm graded stone aggregate) complete all as specified and as directed.
RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in coping, benching including weathering slightly rounded or chamfered angles as directed including necessary form work and finishing the exposed surfaces complete all as specified and as directed.
Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, RCC band, coping etc. also splays between floors and beams, etc complete all as specified and as directed.
Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping ends and binding with and incl mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed.
PVC pipe 110 mm dia low density of pressure rating 10 kg/sqcm (in short lengths) fixed in walls as weep holes as in retaining wall complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Hardcore of gauge of borken stone or boulders n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material and labour for plain cement concrete type E-2, 1:5:10 (Using 40mm graded stone aggregates) as in sub base complete all as specified and as directed.
Material and labour for sand filling as a cushioning/ bedding complete all as specified and as directed.
Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade, glossy finished, with grey cement and pigment complete all as specified and as directed.
Returing filling in, including spreading, levelling, water and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material exc 250 m but not exc 500 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in fdn, filling and mass concrete including complete all as specified and as directed.
Plain galvalume aluminium zinc coating GI based plain steel sheet 0.63mm thick in ridges, hips, valley gutters at the external end slop of any colour having tansile strength 550 Mpa as in roof(ridges) covering fixed with self tapping screws and caps etc complete all as specified and as directed.
10 mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:3 and finished even and fair for receiving tiles/Marble complete all as specified and as directed.
M&L 20mm thick granite stone slab as in shelves / vertical surfaces /platforms set and jointed in neat cement slurry, pointed in colored cement to match the shade including rubbing of moulding etc complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10 cm in width or girth and applying two coats of black bituminous paint over coat of red oxide complete all as specified and as directed.
Preparation of old steel and iron surfaces exceeding 10 cms width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
Preparation of old plastered or un- plastered surfaces and walls including cornices, pilasters etc and applying Two Coats of cement base paint complete all as specified and as directed.
110 mm bore PVC (SWR) pipe single socketed, in any length with rubber joints fixed to walls complete all as specified and as directed.
110 mm bore PVC (SWR) bend any radius complete all as specified and as directed.
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof 100mm bore of pipe complete all as specified and as directed.
Rough excavation in hard/dense soil not exceeding 1.5m deep in and getting out complete all as specified and as directed.
Excavation over areas n.exc 1.5 mtr deep and getting out in Hard/dense soil, complete all as specified and as directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Cement concrete type D-2 ,1:4:8 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
Walling of random rubble,uncoursed,well bonded,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and as directed.
Precast cement concrete 1:3:6 type C1 using 20mm graded crushed stone agregate bonders for stone walling set in cement mortar 1:6 with plain fair faces including chamfers weathering etc complete all as specified and as directed.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in height, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints,, as specified , with maximum depression on face from straight edge n. exc 40mm for lime or sand stone complete all as specified and as directed.
PVC (SWR) pipe, 110mm dia (ISI marked) in any length embedded in cement mortar for weep holes at locations complete all as specified and as directed.
Raised pointing to random rubble masonry, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and as directed.
Hand packing of brocken stone boulder/ boulder (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistranded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5mm and 20mm dia), medium grade with Modular metal flush boxes thickness (1.25mm) & PVC back plate for mounting modular type in adequate module of switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts copper conductor cable 1.5Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
All as per srl item No 49 but for 3 pin 10 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 49 but for 3 pin 10 Amps socket outlet on the same board including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 49 but for 3 Pin 20 Amps socket outlet independent with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
All as per srl item No 49 but for Exhaust fan point controlled by one way switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5mm and 20mm dia), medium grade with sunk Cl / Pressed steel terminal boxes with 3mm thick laminated sheet cover including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed.
All as per srl item No 49 but for 3 pin 5 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 49 but for 3 pin 5 Amps socket outlet on the same board including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 49 but for 3 Pin 15 Amps socket outlet independent with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
Switch flush type 10 Amps single pole one way (Modular Type) with outer strip complete all as specified and as directed.
Switch flush type 20 Amps single pole one way (Modular Type) with outer strip complete all as specified and as directed.
Socket combined 2-in-1, 3 Pin 10 Amps (Modular Type) with outer strip complete all as specified and as directed.
Socket combined 2-in-1, 3 Pin 10 & 20 Amps (Modular Type) with outer strip complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and as directed.
S&F in replacement of MCB Single Pole, 230 Volt, Raiting 6 to 40 Amps complete all as specified and as directed.
S&F in replacement of MCB Single Pole and Neutral , 230 Volt, Raiting 40 to 63 Amps complete all as specified and as directed.
S &F in replacement of Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 08 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Supply and fixing LED Galaxy Flood lights (With Lens) Cat Pt No - HPLLEDFL03060F complete all as specified and as directed.
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
Supply & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 10 Sqmm x 2 core size including taking down old cable complete all as specified and as directed. Note : Earth work and other connected work shall be measured & paid sperately.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard/dense soil and getting out complete all as specified and as directed.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and as directed. Note : for payment purpose punned thickness shall be measured
Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and as directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
Supply and fixing in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-I angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mash and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and as directed.
Switch piano flush type 5 Amps single pole one way complete all as specified and as directed.
S&F for socket 3 Pin 6 Amps flush type complete all as specified and as directed.
S&F Switch socket combination 2-in-3 pin 5 Amps flush type complete all as specified and as directed.
M&L for Switch socket combination 2-in-1, 3 pin 5 & 15 Amps flush type complete all as specified and as directed.
S & F in replacement sheet metal enclosures for DBs when MCBs to be used double door DB VTPN with MCCB 125A 4way IP43 Protection Make: Cat Pt No - 811888 with 125A MCCB 16kA complete all as specified and as directed.
S&F in Replacement of fan regulator electronic, stepped type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed.
Refixing of LED light fitting any type/ any wattage connected with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Taking down/refixing ceiling fan/Exhaust Fan including disconnection of existing connection, dismanting of blades and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and rehanging the fan complete all as specified and as directed.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
khajuria builders
M/S SATINDER PAL & CO.
s l sharma and sons
vmd traders
RAMAN CONSTRUCTION CO
R K BUILDERS
BHAGWATI TRADERS
VARDHMAN INTERNATIONAL
SINGH CONST CO
VIRINDER SINGH
AS BUILDCON
HIMALAYA ENTERPRISES
P N Constructions
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .