Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC | L1 | Accepted-AOC Accepted - AOC | |
| 2 | L2₹42.8 L+₹3.7 L (9.39%)Rejected-AOC | L2 | Rejected-AOC Rejected - AOC | |
| 3 | L3₹44.6 L+₹5.4 L (13.8%)Rejected-AOC | L3 | Rejected-AOC Rejected - AOC | |
| 4 | L4₹53.8 L+₹14.6 L (37.2%)Rejected-AOC | L4 | Rejected-AOC Rejected - AOC | |
| 5 | Rejected-Technical 1 8 373 FLAT NO 704 KRISHE GARDEN BEGUMPET BEGUMPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | - | Rejected-Technical Complete document not submitted |
Tender Value
₹45.6 L
EMD Value
₹91,200
Closing Date
20 Aug 2020, 6:00 pmClosed
GE DEHRADUN
GE Dehradun, Mall Road, Garhi Cantt, Dehradun
PROVN OF ROOF TOP SOLAR PANELS AND GUARD ROOM (17 KUMAON) AND ELETRIFICATION OF MAIN GATES OF 21 MADRAS AT DEHRADUN UNDER GE DEHRADUN
2020_MES_362251_2
8213/A/E8
Open Tender
Civil Works
Item Rate
120 days
GE DEHRADUN
Class D cat a(i) b(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹91,200
Yes
17 Dec 2020
6 Aug 2020
24 Aug 2020
6 Aug 2020
20 Aug 2020
7 Aug 2020
Amount
Supply installation and testing of 2x20 KW mono crystalline SPV modules (solar panels) for 20KW output during peak radiation hours of each plant, made out of hard anodised alluminium frame and covered with toughened glass fixed tilt on and incl hot dip galvanized 50x5 mm angle iron structure suitable to withstand wind pressure 150 Km/hr incl PCC foundation for anchoring of mounting structure with roof etc. on roof tops complete all as specified and as directed. Make: TATA Solar/ Luminous Solar/ Loom Solar/ Warree/ LG Note: (i) Panel should have min 25 years of warranty and efficiency more than 18%. (ii) All accessories like connectors and cable required for interconnection of SPV modules & upto junction box of each string is included in item rate.
All as per item No 1.00 Contd/---- (iii) Switches/ MCBs, fuses, array junction boxes, DC isolator, AC box, SPV junction box and cable from junction box to array box shall be measured and paid separately. (iv) The two set of panels each for 20KW shall be installed on roof tops at two different locations in Dehradun (a) Birpur, Dehradun (b) Garhi Cantt, Dehradun. (v) Bidder is advised to visit the site to get himself acquainted with the site, hight, accessibility, area of roof top and environmental conditions before submission of bid. It shall be deemed that the contractor has visited the site whether he inspects or not. No claim on account of any misunderstanding shall be entertained later on. (vi) Work shall be got carried out through manufacturer or thier authorised distributor/dealer. Contractor shall produce guarantee card along with the material for the items belonging to guarantee provided by the manufacturers, if any. (vii) Similarily guarantee for services to be provided by manufacturer or their authorised distributor/dealer after completion of job, if any, shall be provided. (viii) However contractor shall be liable for the work executed under the contract for defect liability period as per contract conditions.
Supply & Fixing junction box with factory fitted terminal block of size 98 mm x 98 mm x 61mm as per Hensel Cat No D9045 or nearest higher size made of polycarbonate with IP 65 degree of protection (EN60529), dust proof, water tight, shock proof, fire retardant, with internally embedded gasket, PVC Glands for cable entry, suitable for 6 sqmm cable and fixing arrangement with structure of SPV module complete all as directed Make:- HENSEL/ABB/ BCH/Cape
S&F sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with Two runs of 6 Sq mm as current carrying conductor and one run of 6 Sq mm as earth conductor PVC insulated FRLS cable with multi stranded copper conductor of drawing in and incl 20 mm dia heavy duty PVC conduit and accessories such as bend elbow junction boxes etc fixed to wall complete all as specified. Note:- Three runs of wire shall be measured as one meter only for payment purpose.
Supply & fixing polycarbonate DC Array/String box with and incl DIN rail mounted connectors (for negative), DC surge protector with suitable rated DC single pole MCB's or fuse with blow indicator (for positive) for each string and extended handle rotary DC isolator with IP 65 degree of protection (EN60529), dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with factory fitted terminals block, PVC Glands for cable entry and fixing arrangement complete all as directed Make of box:- HENSEL/ABB/ BCH/Cape Make of accessories :- L&T/Schneider/Siemens/Legrand/ABB
Supply and fixing of dual MPPT ON grid power conditioning units/ Inverter three phase, 415 Volts, grid output current 28.9 Amps, max current 31.8 Amps, power factor>0.8, efficiency 98.7%, pure sine wave of min 20 KW capacity output or nearest higher size 160-850 voltage input with low voltage startup with maximum power point tracking features with GPRS or WiFi with RS 485 connector complete all as specified and directed housed with and incl outdoor type weather proof enclosure suitable for ambient conditions prevailing to Dehradun complete with min warranty of 5 years. Make:- L&T/ABB/Solis/Panasonic/Siemens
Supply & fixing of cable (with metal saddles) PVC insulated screened PVC bedded FRLS, unarmoured, electric power cables (heavy duty) with stranded aluminiium conductor, 1100 volts cross sectional area 25 sq. mm 4 Core incl lugs cable glands etc all as directed. Make Havells/Polycab/KEI/Grandlay
Material and labour for CPRI approved chemical earthing complete with GI pipe electrode 50 mm dia, 2 Mtr long with terminal size 50x6 mm buried directly in ground not less than 2.25 m deep below normal ground level and backfilled gel type compound incl connected with and incl galvanized wire 4 mm earth lead duly protected by 15 mm dia GI pipe upto test point including PVC access well & cover with and incl necessary earth work in soft/loose soil for bore hole upto required depth for earth electrode including testing on completion all as specified and directed. Make; SNE/OBO/ENNOVE
S&F of single core 10 Sq mm PVC insulated FRLS cable with multi stranded copper conductor of nominal cross section area as earth conductor with copper thimbles from test point to equipments drawing in and incl 15 mm dia heavy duty PVC conduit and accessories such as bend elbow junction boxes etc fixed to wall complete all as specified and directed.
M & L for three pointed bronze air termination rod of 12 mm dia and 1 mtr long fixed on top of 40 mm dia 3 mtr long medium duty GI pipe incl necessary PCC foundation etc complete all as specified and directed.
Supply and fix aluminium strip 25x3.15 mm with saddles and fixing screws etc for roof and down conductors above test point connected to structure of SPV module and air termination rod complete all as specified
Supply and fix copper strip 25x3.15 mm buried in ground 150 mm below ground including all excavation and earth work connecting one end in test point and another end to earthing terminal etc all as specified and directed.
Material and labour for CPRI approved chemical earthing complete with copper pipe electrode 50 mm dia, 2 Mtr long with terminal size 50x6 mm buried directly in ground not less than 2.25 m deep below normal ground level and backfilled with gel type compound, connected with copper strip earth lead 25x3.15mm by means of nuts bolts check nuts GI washers etc including PVC access well & cover with and incl necessary earth work in soft/loose soil for bore hole upto required depth for earth electrode including testing on completion all as specified and directed. Make; SNE/OBO/ENNOVE
Supply and fixing of test point terminal block made of gun metal or phosphorous bronze 32x6 mm 100 mm long drilled holes for connections of alluminium down conductor and copper earth lead housed in and incl polycarbonate box of size 139x119x70 mm fixed to wall for protection of test point complete all as specified. Make:-Hensel Cat No K 8060 or equalent in ABB/ BCH/Cape
Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed by Engineer-in-Charge .
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified and directed by Engineer-In- Charge.
All as per item No 17.00 here in above but exc 1.50m and n exc3.00 m in depth complete all as specified and directed by Engineer-in-Charge .
M & L for treating the bottom and sides of excavation at the rate of 5 ltrs of emulsion per sqm of surface area complete all as specified and directed by Engineer-in-Charge
M & L for treating the back fill in contact with foundation at the rate of 7.50 ltr of emulsion per sqm of vertical surface complete all as specified and directed by Engineer-in-Charge
M & L for treating the top surface of filled earth at the rate of 5 ltr of emulsion per square meter of surface area complete all as specified and directed by Engineer-in-Charge
M & L for treating the soil under plinth protection at the rate of 5 ltr of emulsion per square meter of surface area complete all as specified and directed by Engineer-in-Charge
M & L for treating the soil along with external perimeter of building at the rate of 2.25 ltr of emultion per meter of the perimeter wall complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in l;ayers not exc 25 cm in soft and loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and directed by Engineer-in-Charge.
M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L reinforced cement concrete 1:1:2 nominal mix (using 20mm graded aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed by Engineer-in-Charge.
M & L reinforced cement concrete 1:1:2 nominal mix (using 20mm graded aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves and this like complete all as specified and directed by Engineer-in-Charge.
M & L reinforced cement concrete 1:1:2 nominal mix (using 20mm graded aggregate) for columns, pillars, piers, post and strut complete all as specified and directed by Engineer-in-Charge.
M & L reinforced cement concrete 1:1:2 nominal mix (using 20mm graded aggregate) for beams, cantilivers, beressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n exc 10cm etc.for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns,footing, plinth beam, roof beam, lintels, slabs and other similar structures etc., hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
All as per item No 35.00 here in above but 5mm dia and over upto and inclluding 10mm dia in stirrups, spacers and binders etc complete all as specified and directed by Engineer-in-Charge
Spreading and levelling in layers excavated earth, n exc. 25 cm thick and well ramming including watering as required complete all as specified and directed by Engineer-in-Charge
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M/L for rendering 15 mm thick in CM 1 : 4 using water proofing compound on fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement (water proofing compound to be measured and paid seperately) complete all as specified and directed by Engineer-in-Charge.
M/L for rendering 15 mm thick in CM 1 : 6 on other than fair faces of brick work or concrete surfaces etc finished even and smooth without using extra complete all as specified and directed by Engineer-in-Charge.
M/L for rendering 5 mm thick in CM 1 : 4 on brick or concrete surfaces (in ceiling) etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for applying three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete complete all as specified and directed by Engineer-in-Charge.
M & L for applying three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete complete all as specified and directed by Engineer-in-Charge.
M&L applying two coats of cement based paint over a coat of primer on new plastered surface incl preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for hardcore of broken bricks of gauge n exc. 63 mm , deposited , spread and levelled and compacted in layers n exc. 15 cm thick , watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M & L for 75 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) as in plinth protection complete all as specified and directed by Engineer-in-Charge.
M & L for 600 X 600 mm size machine cut kota stone slab flooring 20-22mm thick (in one colour) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite mirror polishing complete including 15 mm thick screed bed in cement mortar 1:6 all as specified and directed by Engineer-In- Charge
M & L for machine cut kota stone slab skirting 10-12mm thick (in one colour) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite mirror polishing complete including 10 mm thick rendering in cement mortar 1:4 all as specified and directed by Engineer-In- Charge
M & L for 18 to 20 mm thick marble stone slab (jaisalmer yellow) as in shelves/door cill etc over cement screed base including 15 mm thick bedding layer in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polishing complete for all as specified and directed by Engineer-In- Charge
S & F pressed steel frames of size (125 X 60 MM ) for doors with one or more rebates including necessary fixing lugs, hinges, lock strikes plate, etc,including necessary PCC in backing with bitumen paint in steel surface complete all as specified and directed by Engineer-in-Charge
M & L for factory made 35mm thick of 2nd class hard wood plain framed panelled shutters (any number of pannel) with panel of 12mm thick Ply wood BWR fixed to chowkhat. The size of rails and styles as per SSR Part-I kiln seasoned and chemically preassure treated complete all as specified and directed by Engineer-in-Charge.
M & L for factory made 35mm thick 2nd class hard wood glazed and skelton shutters open riveted on prepared to receive glass, gauge etc without sash bar, edge of framing plain or chemfered or rounded fitted with cut & mitred beads for securing glass etc size of members of shutters as specified in clause 8.20 (a) of section 8 of SSR Part-I (1991), complete all as specified and directed by Engr-in-charge.
S&F factory made 100% solid wood plastic composite (FRP) door frame of size 75 mm x 50 mm x 50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof termite proof fire retardant and having good screw holding capacity all as specification and drawing complete all as specified and directed by Engr-in-Charge. Make : ECHON/Sintex/Jayna (Jain wood industries)
S&F 24 mm thick moulded FRP factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side palin with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire retardent and having screw holding capacity by Engr-in-Charge.Make : ECHON/Sintex/Jayna (Jain wood industries)
S & F 200mm long stainless steel 204 grade bright finished tower bolts complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel 100 mm long butt hinges for PVC door shutters and frames complete all as specified and directed by Engineer-in-Charge.
S & F stainless steel 204 grade bright finishd handles fabricated type of size 150mm complete all as specified and directed by Engineer-in-Charge.
S&F factory made MS box type window / ventiliators fly proof, without sash bar , fixed with dash thru bolts of standard quality including 100 mm long handle in each shutter, 2 Nos tower blots 150 mm long & three hinges of 75 length (box type/capsule type) for each shutter, MS flat for securing wiremesh with machine screws complete all as specified and as directed by Engineer-in-Charge. Notes : Wire mesh and guard bars shall be measured and paid sepearately under respective items of this schedule
S&F factory made MS box type window / ventiliators glazing with sash bar, fixed with dash thru bolts of standard quality, 100 mm long handle in each shutter, 2 Nos tower blots 150 mm long & three hinges of 75 length (box type/capsule type) for each shutter all as specified and as directed by Engineer-in-Charge Notes : Glass & guard bars shall be measured and paid sepearately under respective items of this schedule
S & F Framed work such as grills, gratings ,etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming toFe 290. Gde-E-165
S&F sheet glass ordinary quality 4mm thick and glazing with oil putty , glazing pins in squares n.exc. .5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed.
S&F stainless steel wire cloth. 0.50mm nominal dia of wire with 304 grade nickle and average width of aperture 1.40mm and fixed with stainless steel wire staples/beads/MS flat all as directed by Engineer- in -Charge.
S & F 16 mm dia sliding door bolts,safety type stainless stel 204 grade bright finishd with hasp and stapple (bolt type) and fixing clips of sheet, cast or extruded sectina and fixing bolt and sliding bolts of extruded sections, length of bolt sliding 250 mm long complete all as specified and directed by Engineer-in-Charge
S & F MS helical door spring 300mm complete all as specified and directed by Engineer-in-Charge (Make :- Raja/Ritz)
M & L for painting to new wooden surfaces of any description not otherwise described of 10cm width or new surfaces and applying priming coat with pink primer and two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of synthetic enamel paint on new steel surface over a coat of red oxide primer incl preparation of surface complete all as specified and directed by Engineer-in-Charge.
M&L for screed bed 15 mm thick in CM 1:3 on RCC roof tops when the concrete is still green finished even and smooth using extra cement mixed with water liquid proofing admixture as per manufacturer's instruction complete all as specified and directed by Engineer-in-Charge (Note:- WPC shall be measured and paid separately)
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge
M & L for two coats of damp proof PU paint on plastered surface of roof complete all as specified and directed by Engineer-in-Charge. Note: The water proofing treatment shall be got carried out by manufacturer or their authorised applicators.
M&L coloured glazed non skid ceramic tiles joint free 400X400 mm size and 7 to 8 mm thick , in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile over and including screed bed 15 mm thick in cement mortar 1:6,complete all as specified and directed by Engineer-in-Charge.
M & L for Glazed ceramic ware coloured printed tiles 300x 450 x 6 to 8 mm thick in dado, set and jointed in neat cement slurry and pointed in colour cement to match the surface including 10 mm thick rendring in CM 1:4on any faces of brick work for fixing wall tilesover and including bedding layer of cement mortar .
M & L 15mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified and directed by Engineer-in-Charge.
S & F for 100 mm bore cast iron soil, waste and vent pipes,(spun pipes as per IS 3989) in any length with or without ears with cement joints, laid in trenches or in floors/fixed to walls complete all as specified and directed by Engineer-in-Charge
S & F for 75 mm bore cast iron soil, waste and vent pipes,(spun pipes as per IS 3989) in any length with or without ears with cement joints, laid in trenches or in floors/fixed to walls complete all as specified and directed by Engineer-in-Charge
S & F cast iron cowls 75 mm complete all as specified and directed by Engineer-in-Charge
S & F repair for 100 mm bore cast iron (spun pipes as per IS 3989)branch piece , single (equal or unequal) ordinay or inverted (spigot or socket type ) or with parallel branches complete all as specified and directed by Engineer-in-Charge
S & F for 75 mm bore out let cast floor trap (spun pipes as per IS 3989)with gratings including jointing to waste pipe fixed in cement concrete type (B-1) 1:2:4 etc complete all as specified and directed by Engineer-in Charge
S & F for 75 mm bore cast iron bends (spun pipes as per IS 3989)of (any radius), dimnishing piecs or taper (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer-in-Charge
S&F of vitreous china white glazed orrisa pattern WC size 580 x 440mm complete includcing CI P trap and PVC flush pipe but excl flushing cistrern complete all as specified and directed by Engineer-in-Charge.
S&F PVC Low level flushing cistern 8 ltr capacity dual type incl internal fittings,sypons,handle, PVC bend etc complete all as specified and directed by Engineer-in-Charge.
S & F wash hand basin vitreous china white glazed flat back, size 550 x 400 mm, including pedestal, CP waste coupling and waste pipe brackets and cutting for and pinning in ends of brackets and etc complete in all respect complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous China bowl Urinal half stall of size 465x355x265mm White (minimum) with waste coupling, waste pipe and CP spreader complete all as specified
M & L PVC connection 15mm dia of standard pattern 450mm long, with two Nos brass check nuts and washers etc complete all as specified and directed by Engineer-in-Charge.
S&F 15mm dia bib tap, long body type chromium plated brass, fancy type with crutch or butterfly handle, screwed down complete all as specified and as directed by Engr-in-charge.Jaquar ESSCO DLX 526/MARC ES 526/Perl MAR 078
S&F 15mm dia stop valves/angle valve/concealed stop cock cast copper alloy chromium plated brass,fancy type, high pressure with crutch or butterfly handle screwed down complete all as specified and as directed by Engr-in-charge Jaquar ESSCO DLX 511/MARC ES 508/Perl MAR 075
S&F 15mm dia concealed stop cock cast copper alloy chromium plated brass,fancy type, high pressure screwed down complete all as specified and as directed by Engr-in-charge Jaquar ESSCO DLX 511/MARC ES 508/Perl MAR 075
S&F CP brass fancy type pillar tap complete all as specified and direcated. Make- ESSCO MQT-508 KN or equivalent in Jaquar and Pearl
S&F CP brass shower rose 15mm dia , 125mm dia complete all as specified and directed.
S&F brass CP tubular towel rail 20mm dia D type 60cm long between flanges complete all as specified and as directed by Engr-in-charge.
S&F 500 litres capacity rotational moulded polythylene water storage tanks (cylinderical vertical with close top) three layer external white hoisted and fixed in position including 20mm size ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and tank nipple complete all as specified and as directed by Engr-in-charge.
S & F 20mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type pressed steel terminal box 1.2mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge for the following. Make of PVC Wire: Havells/KEI/Finolex/L&T. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
(a) One light point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
All as per Item No 94.00 here in above but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 400 watts.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC.
S&F lamp holder,pvc/polycarbonate type with back plate suitable for batten fittings complete all as specified & directed.
S&F sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed Make Legrand/Schneider/ABB.
S&F Isolator/MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to IS 8828 ISI marked complete all as specified & directed Make Legrand/Schneider/ABB.
S&F Isolator/MCB single pole and 240 volt 10 KA 5-40 Amp 'B' series conforming to IS 8828 ISI marked all as specified and directed Make Legrand/Schneider/ABB.
S&F wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINE PLUS BS 20W LED 865 SPCSS (Tube Batten) CRYSTAL 1213T8 DSTL 20W LED 865S GLASS (TUBE DOUBLE SIDE)
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a direct fit in holder complete all as specified and directed.
S&F Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 25 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Havells model No. LHETAXU7PA6S025 / Philips Cat Part No BRP410LED CW025GIPSUGR and syska SSK-ST-25W
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with multi stranded aluminum conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and overall PVC sheathed 1100 Volts grade, nominal cross sectional area 10 Sqmm 2 core incl lugs thimbles bottle timbles and gun metal cable glands and heat shrinkable PVC sleeves on exposed surfaces and teflon tape duly insulated complete laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/ floors/ equipment etc complete all as specified and directed by the Engr-in-Charge. Make : Havells/Polycab/KEI/Grandlay
M&L for sand cushioning in trenches for protection of UG cable with river bed sand laid dry in trenches before and after laying of cable, including well ramming and consolidation complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
S&F Air ventilation fan matalic body with louvers, 300 mm sweep single phase 230V, of 900 RPM, connecting with three core 23/0.0076 copper wire from ceiling rose to fan including making necessary opening in brick walls and making good to existing specifications complete all as directed Make : Orient/GEC / Crompton / Havells
S&F Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connections heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed . MAKE: BAJAJ, RECOLD,/ HAVELLS .
S&F ceiling fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan and writing MES No. comlete all as specified and directed Make Havells/ Crompton/ Orient/ GEC.
S&f GI pipe 40mm light grade galvanised with all fittings laid in trenches for protection of cable complete all as specified and directed.
S&F LED integral LED post to lantern 40 watt minium housing heat resistant toughened glass with fram IP-65 protection road way luminaries with high power LED 70/2 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed.
S&F 3 core twisted flexiable weather proof cable PVC insulated and unsheathed mulitstranded copper conductor of size 2.5 sqmm confirming to relevent IS complete all as specified & directed including taking out old unserviceable cable complete all as specified and directed.
S&F pole mounted junction box as per sintex Cat No, 250x200x100mm for fixing cable GS-JB-2520 with provision of four Nos copper busbar with hole for incoming and outgoing, busbar of capacity 100 Amp mounted on epoxy insulator with provision of MCB SP20 Amp 'B' series including all bare conductor of cable duly insulated PVC heat shrinkable sleeve 1.1 KV heavy duty grade CP brass cable glands & lugs for incoming & outgoing connection with provision of drilling hole in pole in bottem and top of the ple for passing of cable from pole box to street light fitting complete all as specfied and directed. Make : Hensel/ Schneider
RAMAPATI ENGINEERING SERVICES
Amit Engineering
SEEMA ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .