| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹44.0 L+₹2.3 L (5.61%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹44.7 L+₹3.0 L (7.19%)Rejected-Finance 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹46.0 L+₹4.3 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹49.3 L+₹7.7 L (18.4%)Rejected-Finance | L5 | Rejected-Finance Being higher bidder |
| Sl No | Description | Qty | Unit | H.S.Kochhar n Sons L1 | GUPTA ENGINEERING WORKS L2 | Balaji Associate L4 | M/s Yash Trading Company L5 | Sethi Brothers L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, commissioning erecting and testing complete of manufacturer or OEM manufactured, static silient (sound proof enclosure) Disel Engine driven Generating set of capacity 160KVA,CPCB-IV water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, inbuilt AMF panel of suitable size including all accessories and measuring instruments as per OEM recommandations,battery of adequate capacity as per OEM recommandations for self starting, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete with inbuilt AMF panel of suitable size including all accessories and measuring equipments as provided by OEM and suitable for conditions prevalent at Agra (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation 1:2:4 type B1 (using 20 mm graded stone aggregate) of size 2.20x1.50x0.30 Mtrs (LxBxH) anti-vibration pads complete all as specified and directed, including all feature to comply with latest CPCB guidelines and comprising of following components:- | 1 | Each Job | 20,50,990 ₹20,50,990 Lowest | 21,99,999 ₹21,99,999 | 22,75,000 ₹22,75,000 | 27,00,000 ₹27,00,000 | 22,22,222 ₹22,22,222 |
| 1.10(a). DIESEL ENGINE :- Diesel engine 1500 RPM, direct injection, multi cylinders, four stroke, conforming to conforming to IS:100001/ISO3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 160KVA at outdoor atmospheric conditionxs at Agra ( Taking all derating factor into consideration) fitting with the following accessories subject to the design of manufacturer:- | ||||||||
| 1.20(i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level (v) Radiator cooling (vi) Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel hoses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly (xi) Lub oil filter and pump (xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid bty as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc 01 set (xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine main manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB regulations (xix) Any other item not included / specified but is a standard design of the manufacturer. | ||||||||
| 1.30(b). Engine insttrument panel : Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp gauge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery of adequate capacity as per OEM recommandations with charger and charging meter. (vii) Safety alarm against high water temp and lub oil pressure. (viii) Any other item not included/specified but is a standard design of the manufacturer. | ||||||||
| 1.40(c ). ALTERNATOR :- Alternator shall be self excited, self regulated, brush less for 160KVA continous operation at the speed of 1500RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS-4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per engineering practice complete all as specifided and directed. (d). Bypass arrangement by providing separate panel outdoor type made out of 3.15mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 250 Amp is to be installed near AMF panel complete all as specified and directed. | ||||||||
| 1.50(e) AMF CONTROL PANEL: Supply, fabricating and testing of factory made/fabricated cubical automatic main failure panel outdoor type with degree of protection IP-42 conforming to IS-2147, suitable for 160 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar, contactors of adequate rating for auto transfer of main / DG supply, internal wiring with control fuse, connecting incoming and outgoing leads/ bus bar as approved with and including following accessories all as specified and directed :- (i) Master switch for auto/manual/reset/off - 01 No. (ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc - 01 No. (iii) Push button start, stop, reset - 01 No. (iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil pressure. (v) Battery charger . (vi) Fault accept / reset push button. (vii) Set of relays and connector 02 Nos of 315/320 Amp suitable for 160 KVA DG Set for automatic start and automatically shut down of suitable rating and capacity and 2 Nos MCCB 4 pole, 315/320 Amp, 36 KA, with thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (viii) Make of AMF control panel shall be as per OEM recommendatins. (f) The above DG set shall be fixed/ mounted on PCC foundation with proper fixing arrangements as directed by Enginner-in -charge. | ||||||||
| 1.60(g) The Precommissioning test of above DG set shall have to be carried out in presence of IEM or any other officer as detailed by accepting officer . The expenditure for testing including cost of fuel consumed/ equipment required for testing shall have to be born by the contractor and which shall deemed to be included in unit rate quoted.No extra payment shall be paid for this account. The testing shall be carried out for 12 Hrs continuously with one hour 10% over load in 12 hours. Note :- Any other items which are not mentined above but essential for standard design to the manufacturer./ execution of work item shall also deemed to be included in the quoted rates | ||||||||
| 2.00 | Supply and fixing the on load change over switch with sheet steel enclosure 4 pole 415 volts with front handle operated 250 Amps and fixed on wall with grouting of nut bolts etc complete and all as specified and directed. | 2 | Each | 15,000 ₹30,000 | 13,000 ₹26,000 | 25,000 ₹50,000 | 18,700 ₹37,400 | 12,000 ₹24,000 Lowest |
| 3.00 | Supply and Laying XLPE insulated LT UG cable PVC sheathed , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor 185 Sqmm 3.5 core laid in trenches or fixed on wall/floor/poles etc including taking down old unserviceable cable complete all as specified and directed. | 100 | RM | 1,100 ₹1,10,000 | 1,225 ₹1,22,500 | 1,100 ₹1,10,000 | 1,000 ₹1,00,000 Lowest | 1,635 ₹1,63,500 |
| 4.00 | Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out etc complete all as specified and directed. | 13 | Cum | 100 ₹1,300 | 100 ₹1,300 | 90 ₹1,170 Lowest | 300 ₹3,900 | 150 ₹1,950 |
Tender Value
₹46.4 L
EMD Value
₹92,700
Closing Date
27 Sept 2025, 6:00 pmClosed
GE TECH AREA AGRA
Military Engineers Services Garrison Engineer (AF) Tech Area Agra - 282008
SPECIAL REPAIR / REPLACEMENT OF BER COOLING APPLIANCES, DG SETS, TRANSFORMERS UNDER GE(AF) TECH AREA AGRA
2025_MES_720524_2
8200-1724/E8
Open Tender
Miscellaneous Works
Item Rate
150 days
AF TECH ATREA AGRA
Class D and above category b(i)
9 documents required · 9 mandatory
₹500
Yes
GE TECH AREA AGRA
₹92,700
Yes
21 Oct 2025
4 Sept 2025
2 Oct 2025
4 Sept 2025
27 Sept 2025
13 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .