Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.0 L+₹37,449 (4.94%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.1 L+₹1.5 L (19.7%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹9.7 L+₹2.1 L (27.7%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
3 Jul 2024, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
O/O The Executive Engineer Kolkata Electrical Division, P.W.Dte. BlockI 1st Floor Writers Buildings, Kolkata 700 001
SITC of Air conditioners Machines at 1st floor Block IV of proposed Service Record Cell, Group T, Finance Department under Writers Buildings Electrical Sub-Division, PWD
2024_WBPWD_697253_1
WBPWD/EE-KED/eNIQ-07Q/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Writers Buildings
Please refer Tender documents.
5 documents required · 5 mandatory
₹16,000
O/O The Executive Engineer Kolkata Electrical Divi
17 Jan 2025
20 Jun 2024
5 Jul 2024
20 Jun 2024
3 Jul 2024
28 Jun 2024
27 Jun 2024
Amount
SITC Microprocessr Controlled, DX Type ceiling suspended Ductable Air conditioner Unit with Indoor& Outdoor Having Following specification i) Refrigerent-R410A/R407C ii) Expansion Valve:Thermostatic/Electronics iii) Compressor :Scroll/TwinRotary with Fixed speed v) ODU: Outdoor Unit Air cooled Condenser unit With Copper coil with Aluminium fins having single compact ODU or multiple ODU unit vi) IDU: Indoor Unit having synthetic Filter and wireless/Wire Remote Vii) CFM: 400/Tr viii)Protection: Single Phase Preventer, phase reversal preventer, HP/LP cut Out. ix)Power sypply: 415+/- 10%, 50Hz x)Ambient temperature: 48°C +/- 5°C (Tollerance) Make: (Make:Hitachi/Daikin/ Blue Star/Voltas/carrier)
Min BTU/Hr: 61200,19.25KW (1 nos. compressor)
Non return Damper with volume control Supply, installation, testing and commissioning of GI volume control Non return duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.(Make: Carryaire/ Dynacraft/ TSC/Ravistar/ Systemair/Airmaster/Air Enterprise)
Fire damper Supplying, Fixing, testing and commissioning of Fusible link type fire damper.. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire in indoor motor and temperature rise above 62 degree centrigate . (Make: Carryaire/ Dynacraft/ TSC/Ravistar/ Systemair/Airmaster/Air enterprise)
REFRIGERANT PIPING WITH INSULATION Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410A/R407C refrigerant & 19 mm thick Nitrile Rubber 'class O' Insulation tube with supports & brackets as per direction of EIC.
Liquid Line ( 5/8" dia) without rubber insulation (make: Rajco / Mandev / Royku)
Suction Line (7/8" dia) with 19 mm thick nitrile rubber insulation Al foil covered (make: Rajco / Mandev / Royku)
DRAIN PIPE Supply and fixing of Drain piping by UPVC with 6mm thick nitrile rubber insulation and necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc:
DUCT WORK Fabrication , supply, Installation , testing & commissioning of following GSS(120 GSM) sheet conforming to IS:655 – 277 (SAIL/ TATA/ JINDAL or as per choice of EIC) rectangular duct complete with neoprene rubber gaskets, elbows, splitter supports, flanges, turning vanes for supply air / return air duct erected with supporting rods, fustners, nuts etc.
Duct Damper Supply & Fixing of powder coated supply air GI volume control damper with diffusers/grilles Make - Premire /Systemair / Air Enterprise / Caryaire /Airmaster
Supply & Fixing of IDU & Duct Covered with 3mm thick ACP Board (Make:Aludecor/Protap Bond) Complete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C. (for tap door )
DUCT THERMAL INSULATION Supplying and fixing of 13mm thickness duly laminated aluminium foil of mat fininshedclosed cell Nitrile rubber (class ''O'') insulation ANTI MICROBIAL COATING type on duct after applying two coats of cold setting adhesive (The joints shall sealed with 50mm wide and 3 mm thick self afhesive nitrile rubber tape insulaton complete as per specifications and as required. for Duct (K-Flex / Amracell / Supreme / K-Flex)
DUCT ACOUSTIC INSULATION Supplying & fixing of acoustic insulation inside ducting with 10mm thick open cell nitrile rubber(class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required. (Make - Armacell / K Flex / Supreme/ A-Flex)
Supplying, fabrication & fixing M.S. Angle Frame for installation of 2 nos Outdoor unit . the structure having 5 nos 50 x 50 x5 mm MS angle for main bottom support grouted on wall with total length 16' and in between main support 7 nos 25 x 5 mm ms strip . For railing vertical & horizontal support is made by 25 x 25 x 5 mm Angle for safety of maintenance , total length 35' ; including cutting holes , welding , painting and mending good damage as per EIC
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 7 core x 2.5 mm² (Make- Polycab/ Havells/Gloster/RR).
Providing and fixing fire retardant nonporous double layer flexible connection between IDU(FR)
NATIONAL AIRCON
S.R. REFRIGERATION AND APPLIANCES
UNIVERSAL SALES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .