Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹50.2 L+₹1.7 L (3.40%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹50.3 L+₹1.8 L (3.65%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹50.4 L+₹1.9 L (3.84%)Rejected-Finance NETAJI SUBHAS ROAD SUBHASPALLY SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹50.7 L+₹2.2 L (4.47%)Rejected-Finance PO BANARHAT DIST JALPAIGURI W B PIN 735202 | BANARHAT | JALPAIGURI | WEST BENGAL | 735202 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Bengdubi
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
COMPRENSIVE MAINTENANCE TO B R AND E M SERVICES AT TECH AREA AND OTHER ALLIED UNITS UNDER AGE BR I AND AGE E M OF GE BENGDUBI
2024_MES_641796_1
8526/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Bengdubii
MES Enlisted/ Un-enlisted contractor of Class D and above with category a(i) and c(i)
7 documents required · 7 mandatory
₹500
Garrison Engineer
₹90,000
Yes
21 Mar 2024
10 Feb 2024
8 Mar 2024
10 Feb 2024
6 Mar 2024
1 Mar 2024
12 Feb 2024 - 17 Feb 2024
Amount
B/ R Items: M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in hold fast and block filling of pressed steel chowkat including necessary formwork if required etc complete all as specified and directed.
Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed.
M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for Granite (of any type) work(table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar(1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F 2nd class HW rail and style 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, including cutting holes for removing the hold fast, making good disturbed surfaces and removing materials from site of work complete all as specified and directed.
Taking down old unserviceable shutters of any description exc 1.00 but n.exe 2.00 Sqm each complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatm moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain/decorative colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement in the frame at site as per specification & drawing. etc complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing complete all as specified Note:-The door frame to be fixed to wall using 8 x 100 mm long anchor fasteners.
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 250 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd.
S&F 100mm Butt hinges,medium weight, cold rolled mild steel, complete all as specified and directed.
S&F 150mm size aluminium handle cast type complete all as specified and directed.
S&F in repair tubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and directed.
M&L for Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe -410-W(Gde-E-250) quality-A. complete all as specified and directed.
S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete with glazing bars dovetailed or welded complete all as specified and directed.
S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete without glazing bars dovetailed or welded complete all as specified and directed.
M&L for 1.25mm thick pressed steel door frame of size 105mm x 60mm with one or more rebates including necessary fixing lugs , hinges, lock strike plate etc complete all as specified and directed.
S&F for 1.25mm thick pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc.complete all as specified and directed.
M&L for anodised aluminium snap grid (SIZE-605x605MM) frame work for false ceiling complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed.
S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed.
S&F 4 mm thick designed Non asbestos fiber cement building boards, fixed or laid /inserted to timber /GI /Aluminium frame-work with screws as in ceiling complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base of hardstanding, floors, path, ramp etc and finishing the surface without using extra cement complete all as specified and directed.
Dismantling of floor, hearth or wall tiling / Paving Blocks including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for sheet glass, 4mm thick, ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each pane complete all as specified and directed.
S&F 4.0mm thick Figured/frosted glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each panecomplete all as specified and directed.
M&L for preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
M&L for two coats of synthetic enamel paint on false ceiling including preparation of new surfaces of any description over 10 cm width or girth complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed.
S&F medium grade galvanized steel tubing (concealed) with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified and directed.
S&F medium grade galvanized steel tubing (concealed) with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and directed.
Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 15 mm dia bore complete all as specified and as directed
Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 20 mm dia bore complete all as specified and as directed
Dismantling water tanks and removing to store exc 250 ltr but not exc 500 ltr capacity complete all as specified and as directed
S&F rotational moulded PVC water storage tank 500 ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top (thereated) including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc completge all as specified and directed.
S&F in repair 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F fancy type stop valve cast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for union and fixed of size 15mm dia complete all as specified and directed.
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20mm bore and fixed as in repair complete all as specified and directed.
S&F in repair Ball brass valves, high pressure, with polyethene float and fly nut complete, screwed for GI pipe or brass ferrule of 20mm bore complete all as specified and directed.
S&F PVC connections pipe ,15mm dia size with PTMT nuts of length 600mm complete all as specified and directed.
S&F in repair 75mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair 110mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings incl ridges, hips and valley gutter complete all as specified and directed.
Dimantling of Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridges etc complete all as specified and directed.
Dismantling wall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as speecified and directed. Note : (i) Weight of Aluminium sections as per actual or as per IS or as per Manufacturer which over is less, shall only be considered for payment. (ii) Cost of all the items/ accessories required for the entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wirecloth shall be measured and paid separately under respective items. (iii) The accessories (Aluminium mongries etc) required to be provided for window, vents and doors as per directions of GE shall be provided but weight for the same shall not be considered and no extra cost will be paid.
M&L for powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as speecified and directed.
M&L for powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as speecified and directed.
M&L for Glazed ceramic tiles coloured 300mmx 450mm , 6 to 7 mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface etc complete all as specified and directed.
M&L for Non Skid ceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including screed bed or bedding layer 20mm thick in cement mortar 1:6 for laying floor finishes etc complete all as specified and directed.
M&L for Non Skid ceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including screed bed or bedding layer 20mm thick in cement mortar 1:6 for laying floor finishes etc complete all as specified and directed.
M&L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular)polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in cement mortar 1:6 etc complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size nconfirming to IS 15658-2006 of 60 mm thickness, M-35 Grade compacted over and including 25mm thick sand well rammed and compacted complete all as specified and directed.
M&L for pre polished coloured cement concrete chequred tile size 300x300x25mmthick with grey cement and no pigment of approved quality thick on floors over and including 20 mm thick screed bed cement mortar 1:6 set and jointed in neat cement slurry and pointed with colour to match the tiles complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in two layers 10mm +5mm in cement mortar 1:4 on external surfaces of brick work or concrete surfaces with using WPC finishing the surfaces even and smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured and paid separately under respective item of this schedule.
M&L for 5mm thick rendering in cement mortar 1:3 over/soffit of chajja/ceiling, finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new undecorated surface of ceiling and applying two coats of white wash complete all as specified and directed.
M&L preparation of new plastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed.
M&L for preparing of old existing surfaces and stopping of distempered and painted surfaces and applying one coat of cement based paint (any tint) on walls complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distember over a coat of primer white or any tint over 1mm thick wall care putty complete all as specified and directed.
M&L for preparing of old existing treament and stopping of distempered and painted surfaces and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over prepared surfaces complete all as specified and directed.
M&L for preparing of old existing treament and stopping of distempered and painted surfaces of wall and applying one coat of oli bound distemper (any tint) complete all as specified and directed.
M&L for 5.5 mm thick sheet glass ordinary quality frosted on one side including glazing clips, rubber packing etc exc. 0.5 sqm in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness size quality and discription) for metal frame exc 1.5 sqm including punching, drilling out old glazing pins / spring clips and providing new ones complete all as specified and directed.
M&L for preparing the back surfaces of chaukhats and treating them with tar or coal tar black paint complete all as specified and directed.
S&F in repair bib tap fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia bore pipe complete all as specified and directed.
S&F in repair for stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore of pipe complete all as specified and directed.
S&F in repair Vitreous china wash down water closet European type (pedestal pattern) (excluding flushing cistern and flush pipe) Seat and cover for pedestal pan including connection to outgoing pipe and seat cover and flushing pipe complete all as specified and directed.
S&F in repairs 10 lits capacity PVC flushing cistern low level, white, with inlet, ball valve, float and handle and flush pipe including brackets etc complete all as specified and directed.
S&F in repair vitreous china wash hand basin in repair oval special type 510x410mm including CP fancy type 15 mm pillar taps including 32mm dia PVC waste pipe, and 32 mm dia brass CP waste coupling complete all as specified and directed.
M&L any size and type mesh aluminium anodised grills of approved designs complete all as specified and directed.
S&F jet spray with 01 mtr PVC tube (Stainless steel) complete all as specified and directed.
S&F in repairs two way angle cock 15mm bore cast copper fancy CP alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F Soap dish brass chromium plated fixed with chromium plated brass screws complete all as specified and directed.
S&F in repair chromium plated shower roses 125 mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions etc complete all as specified and directed.
S&F 2nd class hard wood 30 mm thick made glazed and skeleton shutters open rebated and prepared to rceieve glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as spfd in SSR Part-1, Section 8, clause 8.24 (b)window, kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for providing and fixing PVC FALSE CEILING consisting of 600x600mm, 5mm (+0.25) thick plain ambossed PVC sheet of 600Kg/Cbm Density manufactured by ISO 9001-2008, certified company, used as panel insert in a frame work made using anodised aluminium T- section of sizes 1"x1" (25x25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2'x2'(600x600mm). the aluminium frame work is supported from the ceiling with the help of "J" hook and GI wire/6mm MS rods of require sizes to maintain proper level etc. The aluminium framework is supported on side wall with the use of aluminium L-section of size 1"x1"(25x25mm) angles etc. complete as specified by manufacturer & drawing and directed by GE.
E/M Items:- Dismantling all electrical connection and taking out indoor/outdoor unit of split AC after disconnect suction & liquid line and repair cleaning, servicing and overhauling of the same including Air filter, blower motor (indoor/outdoor) and adjusting of remote control and checking all electrical devices including fixing cable socket/ gland etc and reassembling and fixing in position and leakage check the unit , charging refrigerant gas as required in the system complete all as specified and directed. Note:- (i) Spares required for repair and gas shall be measured and paid seperately under respective item of this schedule. (ii) Contractor shall attend any type of complaint as and when required and no extra payment shall be allowed.
Supply only the following spare parts for split type AC machine including removing unserviceable old one complete all as specified and directed.
Running capacitor 40/50 mfd 4/6/8 pole 440 volt, AC including necessary copper wire.(Make : Sarda or Equivalent)
Starting capacitor 100/120 mfd 230 volt 50 Hz including necessary copper wire (Make - Sarda or Equivalent).
Starting capacitor 80 mfd 230 volt 50 Hz including necessary copper wire (Make - Sarda or Equivalent).
AC contactor relay for split AC.
Starting relay for 1.5/2.00 TR split AC (Make - Arvind or Equivalent).
Copper pipe 1/2" for liquid line including fittings
Copper pipe 5/8" for suction line including fittings
PVC Fan blade suitable for outdoor condenser unit including necessary brass nut bolt etc.
Drain pipe 25 mm dia suitable for spilt AC with necessary saddle screws complete all as specified and directed.
Outdoor unit condensor coil for Split AC 1.5 TR
Outdoor unit condensor coil for Split AC 2.0 TR
Air filter for Split AC of any size.
Indoor unit cooling coil for Split AC 1.5 TR
Indoor unit cooling coil for Split AC 2.0 TR
liquid sensor for Split AC 1.5/2.0 TR
Air sensor for Split AC 1.5/2.0 TR
Taking down old u/s remote control assembly and dismantling the unit and replaced the unserviceable item such as PCB, transformer and magnetic coil suitable for split AC and reassembling the same including testing complete all as specified and directed.
Dismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burned compressor of capacity 2 TR and supply and install new compressor 2 TR 230 V, 50 Hz suitable for split AC including recharging of gas (M-22), mounting pad nut and bolt and reassembling all the connection in its original location and testing complete all as specified and directed. (Make - Carrier/ Kirloskar/ Emerson).
All as per item No.100 here - in - before but 1.5 TR capacity.
Dismantling all electrical connection from the blower motor and taking out unserviceable burnt blower motor and supply and install blower motor suitable for 2/1.5 TR split AC and reassembling all the connection in its original location and testing complete all as specified and directed..
All as per item No.102 here-in-before but condenser fan motor 2/1.5 TR split AC.
Supply and fixing remote control asy with control circuit or connected wire suitable for 2 TR/1.5 TR split type AC.
S&F swing motor(Synchronous motor) AC 220 Volt, 50/60 Hz for split type AC including necessary connection wire after taking out old one complete all as specified and directed.
S&F factory made split AC stand complete with fixing in wall with hinges, nuts and bolts complete all as specified and directed.
S&F PCB board suitable for 1.5 /2 TR split AC/window AC complete all as specified and directed.
S&F insulation tube for suction / liquid line complete all as specified and directed.
Supply and charging Gas M-22 or equivalent to Split AC/Window type AC machine/Water Cooler including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
Dismantling of defective deep frezer of any capacity, size and type for thorough checking/ including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components and testing including transportation to whorkshop and back complete all as specified and directed. (NOTE :- New accessories / components required shall be measured and paid separately, labour charges for fixing shall be included in the unit rate of respective item)
Supply only following spare parts for Deep Freezer :-
Relay for deep freezer of any size/capacity
Overload relay for deep freezer of any size/capacity
Starting capacitor 60/40 Mfd
Starting capacitor 80/100 Mfd
Running capacitor 6/15 Mfd
Thermostate for deep freezer
Condenser fan motor 240 volt
Supply only deep fridge compressor for storage capacity of 400/500 ltrs deep fridge and testing the performance all as specified and directed by GE. (Cat Part No. L-415) (Recharing of gas will be measured and paid separately).
Dismantling and opening voltage stabiliser 5 KVA capacity single phase, 240 volts and replacement of old unserviceable worn out/defective parts and reassembling the same after necessary repair, cleaning servicing and testing on completion for its satisfactory performance all as specified and directed by GE. (spares required will be measured and paid separately) (Make - Raditror/ Emcon/ V-Guard/ Microtech/ Sen & Pandit or as specified).
All as per item No. 113 here-in-before but 4 KVA capacity
All as per item No. 113 here-in-before but 3 KVA capacity
All as per item No. 113 here-in-before but 2 KVA capacity.
All as per item No. 113 here-in-before but 1 KVA capacity.
All as per item No. 113 here-in-before but 0.5 KVA capacity.
Supply only main transformer suitable for automatic line voltage corrector 5 KVA, 230 volts, 50 Hz complete all as specified and directed.
All as per item No. 119 here-in-above but 4 KVA capacity.
All as per item No. 119 here-in-above but 3 KVA.
All as per item No. 119 here-in-above but 2 KVA capacity.
All as per item No. 119 here-in-above but 1 KVA capacity.
All as per item No. 119 here-in-above but 0.5 KVA capacity.
Supply only relay (time limit) suitable for automatic line voltage corrector of capacity 0.5 to 1 KVA all as specified and directed.
Supply only voltage regulating circuit board (PCB) of suitable size/ type including all necessary electrical components for operating the main transformer for output voltage 200 volts to 230 volts (2% tolerance) including all electrical connection complete all as specifed and directed.
Supply only voltage regulating transformer of voltage rating 220/12 volts to 6 volts bridge type or central type transformer of current carrying capacity 600 mA per second, any size to separate the regulating circuit board complete all as specified and directed.
Supply only relay over load for stabilizer any type.
Dismantling of defective refrigerator of any make and capacity for thorough checking of all accessories and components, repairs and reassembling the same after repair/ replacement of defective accessories/components and testing complete all as directed by GE including transportation to workshop and back complete all as specified and directed. NOTE :- New accessories / components required shall be measured and paid separately, labour charges for fixing shall be included in the unit rate. Repair of body overhauling / repair sealeds unit (compressor ) gas charging painting etc shall be measured and paid separately. Old serviceable accessories / components obtained shall be refixed as directed by the GE,and labour charge for refixing to be deemed to be included in unit rate quoted.
Supply only the following suitable accessories components of refrigerator (Make - Kelvinator/Allwyn /Godrej/Whirlpool/Usha/Samsung/LG) :-
Cooling chamber including cooling coil of size shape suitable for refrigerator of size and of capacity upto 210 ltrs . (Make Godrej/ Whirlpool/ Kelvinator).
All as per item No. 130.01 here-in-before for refrigerator of capacity above 210 ltrs.
Thermostat defrost type switch suitable for refrigerator of capacity upto 310 ltrs (Make - Whirlpool/ Godrej/ Annapurna).
PTC Relay with overload suitable for refrigerator of capacity upto 310 ltrs.
PTC relay with overload with capacitor for cap upto 310 Ltr Make whirpool/Godrej/Annapurna
Condensor coil of suitable for size of refrigeration capacity upto 210 ltrs .
Condensor coil of suitable for size of refrigeration capacity above 210 ltrs .
Magnetic door gasket including fixing accessories for refrigerator of any capacity.
Capillary tube of size 0.31 for any type/size refrigerator
Door switch for refrigerator of any capacity.
Lamp holder, screwed/pin type including 15 watt, lamp 240 volts.
LED lamp for any capacity
Inner shelf for refrigerator of capacity 165 ltrs.
All as per item No. 130.13 here-in-before but for refrigerator of 286 to 310 ltrs capacity.
PVC chillar tray for refrigerator of capacity 165 ltrs.
All as per item No. 130.15 here-in-before but 286 to 310 ltrs.
Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm .
Vegetable tray for 165 ltrs refrigerator.
Vegetable tray for 286 to 310 ltrs refrigerator.
Running capacitor 6 / 10 mfd
Frost free fan motor SP 230 volts
Heating coil including fixing accessories suitable for 250/286/310 ltrs
T-Fuse for refrigerator of cap 250/286/310
Supply only gas R-134
Taking out burnt compressor for Regrigerator of Capaicty 165/200 Ltrs after disconnecting suction and discharge line and supply and fixing compressor and testing the performance all as specified and directed by GE . (Re Charging of gas will be measured and paid separetely)
All as per item No.131 here-in-above but for compressor of capacity of refrigerator 250/286/310 ltrs .
S&F Vaccuming dehydration for refrigerator of capacity 165 ltrs to 210 ltrs leak testing of the system as per system standard practice testing for proper cooling effected and satisfactory performance complete all as specified and as directed .
All as per item No. 133 here-in-before but for refrigerator of capacity 286 to 310 ltrs.
S&F PCB board suitable for refrigerator to control temp/conversion in system of capacity 165/280/310 ltrs complete all as specified and directed.
Dismantling of defective water cooler storage type 40 ltrs capacity for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components and testing complete all as specified and directed by the GE including transportation to whorkshop and back complete. NOTE : (a) New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate of respective items (b) Repair of body overhauling/repair, sealed compressor unit gas charging, painting etc shall be measured and paid separately.
All as per item No. 136 here-in-before for water cooler storage type 80 ltrs capacity.
All as per item No. 136 here-in-before but for water cooler storage type 120/150 ltrs capacity.
Supply only the following accessories/components suitable for water cooler complete all as specified and directed.(Make:- Shreeram/ USHA/ BLUE STAR/Voltas) :-
Condensor coil for water cooler 40 ltrs capacity of similar specification as of old one.
All as per item No. 139.01 here-in-before but water cooler of 80 ltrs capacity
All as per item No. 139.01 here-in-before but water cooler of capacity 150 ltrs/120 ltrs
Aluminium fan blade for blower motor for water cooler of capacity 40/80/120/150 ltrs (storage capacity)
Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120/150 ltrs (cooling capacity).
Thermostat including plastic regulating knob for water cooler of capacity (cooling) 40/80/120/150 ltrs.
Relay for water cooler type suitable for water cooler storage cooling capacity 40/80 ltrs/hrs (Make - Annapurna/Godrej/usha/Blue star).
All as per item No. 139.07 here-in-before but 1022/522 for water cooler 150/120 ltrs/hours capacity.
Over load protector type 1022 suitable for water cooler 120/150 ltrs/hrs capacity. (Make - As per sample)
All as per item No.139.09 here-in-before but type 522 AC suitable for water cooler of capacity 40/80 ltrs/hrs (Make - As per sample)
Self closing bib tap/push tap 15mm dia chromium plated steel suitable for water cooler 40/80/150/120 ltr/hrs capacity.
PVC connection pipe high density 15mm dia300mm long including jublee clamps (for inner connection from tank outlet to tap).
PVC connection pipe, type 15 mm dia 450 mm long complete with PVC union at both end. (Make - Prayag/ Prince/ kisan)
Stop cock brass both end screwed 15 mm
Float valve PVC complete with all accessories 15 mm dia. Make - Prayag
Running Capacitor 10/15 mfd 230 volts AC, 50 Hz suitable for water cooler (Make - Sarada or equivalent)
Starting Capacitor 80/100 mfd, 50 Hz 230 volts(Make - Sarada or equivalent)
All as per item No. 139.17 here-in-before but 40/60 mfd, 230 volts.(Make - Sarada or equivalent)
Supply only the following items :-
Capillary tube copper size 0.61/0.70
Capillary tube copper size 0.41
Copper pipe 1/2"
Copper pipe 3/8"
Copper pipe 5/16"
Copper pipe 1/4"
Copper pipe 3/16"
Supply only New compressor and testing the performance all as specified and directed by GE. SRA-100/SRA-200 SF, 40/80 ltr/hrs suitable for storage capacity complete all as specified and directed. (Recharing of gas will be measured and paid separately).
All as per item No. 141 here-in-above but compressor of water cooler of storage capacity 60/120 ltrs/hrs,
All as per item No. 141 here-in-above but for compressor of water cooler of sotrage acapacity of 80/ 160 ltrs/hrs.
S&F Vacumming, dehydration for water cooler of capacity 80/40 ltrs/hrs leak testing for the system as per standard practice, testing for proper cooling effect and satisfactory performance complete all as specified and as directed by GE . Note: refrigerant gas (R-134/M-22) will be measured and paid separately.
All as per item No.144 here-in-above but for water cooler of storage capacity 120 ltr/hrs.
All as per item No.144 here-in-above but for water cooler of storage capacity 150 ltr/hrs.
Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testing suitable for water cooler of any type complete all as specified and directed.
Supply and fixing Socket outlet 3 pin, 15 amps, flush type 2/3 pin multipurpose of complete all as specified and directed.
M&L for cutting through brick wall built in cement mortar for provision of window type AC any size /capacity and making good with cement mortar 1:4 including three coat of white washing on new plastered surface wall including preparation of surface all as specified and as directed.
S&F sheet metal enclosure SPN with two pin earth plug and socket complete width one SP MCB 20 amps 240 volts including dismantling old one complete all as specified and directed.
S&F switch socket combination 15 amps 3/5 pin flush type complete all as specified and directed.
Supply and fixing MCBs-C curve-10 KA, single pole 6 to 32 amps capacity after taking old one complete all as specified and directed.
Supply and fixing MCBs-C curve-10 KA, DP 32 amps capacity complete all as directed.
M&L for sub main wiring with two single core 4 sqmm PVC unsheathed copper conductor cable FRLS concealed through PVC conduit 25mm dia with medium grade contineous earth wire PVC insulated cable with copper conductor wire FRLS of size 4sqmm dolly connected to main earth with taking down old onecomplete all as specified and directed. (Note : Two run of4sqmm wire, one run of 4sqmm earth wire and PVC conduit for suitable size measured as one unit).
M&L for sub main wiring with two single core 6 sqmm PVC unsheathed copper conductor cable FRLS concealed through PVC conduit 25mm dia with medium grade contineous earth wire PVC insulated cable with copper conductor wire of size 6 sqmm dolly connected to main earth. with taking down old one complete all as specified and directed. (Note : Two run of 6sqmm wire, one run of 6 sqmm earth wire FRLS and PVC conduit for suitable size measured as one unit).
Dismantling all electrical connection and taking out room type AC after disconnect the complete and repair cleaning, servicing and overhauling of the same at site including Air filter, adjusting of remote control and checking all electrical devices including fixing cable socket/gland etc and reassembling and fixing in position charging refrigerant gas as required in the system complete all as specified and directed. (spares required for repair and gas shall be paid separately) Note :- Contractor shall be attend the any type of complaint at site as and when required and no extra payment shall be allowed.
S&F outdoor unit of split AC 2.0 TR complete with all accessories (such as compressor, wiring, copper pipes) incl fixing on wall/floor complete all as specified and directed.. Make Samsung/LG/Whirlpool/Camipro. (Note :- Charging of gas shall be measured paid separately)
All as per item No. 157 but 1.5 TR.Make Samsung/LG/Whirlpool/Camipro. (Note :- Charging of gas shall measured and be paid separately)
S&F indoor unit of split AC 2.0 TR complete with necessary accessories (such as cabinet, wiring, copper pipes, remote control, swing motor) incl fixing on wall/floor complete all as specified and directed. Make Samsung / LG / Whirlpool / Camipro. (Note :- Charging of gas shall be measured and paid separately)
All as per item No. 159 but 1.5 TR. Make Samsung / LG / Whirlpool / Camipro. (Note :- Charging of gas shall be measured and paid separately)
Dismantling of defective window type room air conditioner of any make and capacity for thorough checking repair of all accessories and components and reassembling the same after repair/replacement of defective accessories/components and testing complete all as directed by GE. Note : (a) New accessories / components required shall be measured and paid separately Labour charges for fixing shall be included in the unit rate. .(b) Repair of body , overhauling/repair sealed unit (compressor), gas charging, painting etc shall be measured and paid separately. (c) Old serviceable accessories/ components obtained from item above shall be refixed as directed by GE. Labour charges for refixing to be deemed to be included in the unit rate quoted of respective item.
Supply only the following accssories/components suitable for window type air conditioner (Make - Carrier/Voltas/F. Loyed/LG/ Shreerram/Blue star):-
Cooling coil assembly with copper tubes of specification similar to old one.
Aluminium/PVC blade for blower motor for window type air conditioner (1.5/2 TR capacity).
Air filter of PVC suitable for AC
Aluminium runner suitable for AC
Thermostat with regulator knob (Make Infoss/Annapurna) for AC
Relay type 1622 suitable for window type air conditioner (1.5 TR/ 2TR capacity) Make - Shreeram/ Annapurna)
Over load protector type DC 1622 surge voltage 250 volts RNQ suitable for window type air conditioner (1.5 TR / 2 TR capacity) Make - Shreeram).
PVC insulated and sheathed cable 3 core, 1100 volts grade flexible with stranded copper conductor of size 4 sqmm
Starting capacitor 80/100 mfd, suitable for window type room AC (Capacity 1.5 TR/2.00). Make - Sarada.
All as per item No. 162.09 here-in-above but for 100/120 mfd (Make - Sarada
Running capacitor 40 mfd 240 volts, AC 50 Hz, type SMRC suitable for room AC (Capacity 1.5 TR / 2.00 TR).
All as per item No.162.11 here-in-above but 45/50 mfd.
PVC front grill suitable for window type room AC of any make any type (as per sample).
Swing motor for window type AC 1.5 ton capacity.
Wiring set complete suitable for AC.
Relay 4 pole switch for AC/refrigerator.
Dismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burned compressor of capacity 2 TR and supply and install new compessor 2 TR 230 V, 50 Hz suitable for window AC including charging of gas (M-22), mounting pad nut and bolt and reassembling all the connection in its original location and testing complete all as specified and directed. (Make - Carrier/ Kirloskar/ Emerson).
All as per item No.163 here-in-above for compressor of capacity 1.5 TR.
S&F PVC insulated cable 3 core round flexible stranded copper conductor of size 2.5 sqmm complete all as specified and directed.
S&F plug top 3 pin 15 amps 240 Volts complete all as specified and directed.
Taking down damaged insulated portion of suction line and discharge line and supply & fixing of new PVC insulation tube complete all as specified and as directed.
S&F plug top suitable for industrial socket 3 pin incl earth point 240 volts complete all as specified and directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 1,57,215.00 (refer Tender Srl Page No 42(R)). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S East India Traders
KD SAHA and CO.INDIA
SARKAR ENGINEERING CO.
SHRI SANJAY KUMAR GUPTA
SHRI PRADEEP PARIK
M/S BIJAY KUMAR SHIVA
M/S ANNI ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .