| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr Quoted ₹4.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹4.2 Cr+₹1.6 L (0.39%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹4.2 Cr+₹1.6 L (0.39%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹4.3 Cr+₹7.8 L (1.86%)Rejected-Finance | ₹4.3 Cr+₹7.8 L (1.86%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹4.3 Cr+₹8.0 L (1.91%)Rejected-Finance | ₹4.3 Cr+₹8.0 L (1.91%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹4.3 Cr+₹10.9 L (2.59%)Rejected-Finance | ₹4.3 Cr+₹10.9 L (2.59%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
18 Feb 2022, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF TYPE VI QTRS FOR MES CIVILIANS OFFICERS AT PUNE
2022_MES_502931_1
84521E8 CEPZ/PNA/TOKEN-15 OF 2021-22
Open Tender
Civil Works
Lump-sum
300 days
Pune
Class A
Category a(i)
See NIT also
8 documents required · 8 mandatory
₹2,000
GE(I)(P)CH Pune
₹4.0 L
Yes
9 Mar 2022
21 Jan 2022
21 Feb 2022
21 Jan 2022
18 Feb 2022
4 Feb 2022
22 Jan 2022 - 31 Jan 2022
Amount
NOTE: Schedule ‘A’ Part I to XII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-13 only.
Total amount of Sch 'A' Part-I (Building Works/ Structure)
Total amount of Sch 'A' Part-II (Internal water supply)
Total amount of Sch ‘A’ Part III (Internal Electric Supply)
Total amount of Sch ‘A’ Part IV (External Water Supply)
Total amount of Sch ‘A’ Part V (External Electric Supply)
Total amount of Sch ‘A’ Part VI (Hot water supply)
Total amount of Sch 'A' Part-VII (Road path culvertts)
Total amount of Sch 'A' Part-VIII (Sewage Disposal)
Total amount of Sch ‘A’ Part IX (Area drainage)
Total amount of Sch 'A' Part-X (Compound wall & gate)
Total amount of Sch ‘A’ Part XI (Site Clearance/ Excavation & Earthwork)
Total amount of Sch ‘A’ Part XII (Partially completed Deviation Order in completed/partially completed work)
Note: Schedule 'A' Part XIII (Miscellaneous B/R and E/M works) is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
S&F exhaust fan, single phase, light weight, PVC frame, 300 mm sweep, 1400 RPM, white/ivory plastic rust proof body and blades, self opening louvers for protection from birds and rain water, including fixing of mounting frame in the round hole cutitng in the wall by means of rugged bolts, nuts and washers etc including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of exhaust fan complete all as specified and directed.
Supply & fix ceiling fan 5 star rating BEE mark (with and including assembling the same) with providing fan hook/box, 1200 mm (48") sweep and connecting up, with modular fan regulator complete with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan suitable on working AC, SP 230 V electric supply regulator complete all as specified and directed.
Supply & fix wall Mounted fan suitable for 240 volt, 50C/S, 300mm, Plastic bosy and blade, high speed fan, pull card for speed contraol complete as required including providing all fixing accessories. Make Crompton, Model WM wind flo 12 Hi speed 300mm or equivalent in make of Havells/Bajaj/C&G complete all as specified and directed.
S&F LED 1X20 Watt 230 V, Energy saver indoor domestic plastic extruded luminaire with decorative end caps, complete with all accessories and all as specified. Make- Cat No.LTT8-20 of Crompton Greaves or equivalent model in Havells/Phillips/C & S/ Bajaj as approved by GE.
S&F LED 1X18 Watt 230 V, Energy saver indoor domestic plastic extruded luminaire with decorative end caps, complete with all accessories and all as specified. Make- Cat No. LPLL-18-CDL of Crompton Greaves or equivalent model in Havells/Phillips/C &S/ Bajaj as approved by GE.
S&F Lamp holder, angle / straight pin type PVC/polycarbonate type with back plate including LED 1x9 W lamp. Complete all as specified and directed
S&F Bed Side LED light fitting 1X12 Watt 230 volts, complete with all accessories and all as specified and directed.Make- Cat No.ALPHA 12W WW of Bajaj or equivalent model in Phillips/Crompton Greaves/Havells/ C & S approved by GE.
S&F Mirror LED light fitting 1X08/07 Watt 230 volts, complete with all accessories and all as specified and directed.Make- Cat No.LCL-07CDL of Crompton or equivalent model in Phillips/Bajaj/Havells/ C & S approved by GE.
S&F LED security light fitting 30 Watt 230 volts, complete with all accessories including provision of fixing arrangement on wall complete and all as specified and directed.Make- Cat No.LTESS30WLED of C & S or equivalent model in Phillips/Bajaj/Havells/ C & G approved by GE.
S&F Ceiling light fitting surface mounted LED with broad collar frame suitable for 600 x 600 mm modular ceiling complete with LED lamp, complete with all accessories and all as specified and directed.Make- Cat No.LCTLSN-36-CDL of Crompton or equivalent model in Phillips/Bajaj/Havells/ C & G approved by GE.
S&F MCB TPN AC 415 volts, 10 KA, 40Amp 'C' Series complete all as specified and directed.
S&F MCB SP 240 Volt, 6 to 32 Amps, 10 KA 'C' Series complete all as specified and directed.
S&F MCB SP & N 240 Volts 6 to 32 Amp 10 KA 'C' Series complete all as specified and directed.
S&F Single phase Electric energy meter, range 5-30 Amp alongwith transparent pilfer proof meter box complete all as specified and directed.
S&F three phase Electric energy meter, range 10-40 Amp alongwith transparent pilfer proof meter box complete all as specified and directed.
Design, fabricate, supply, testing and commissioning of CPRI approved factory made LT cubical panel board indoor type fabricated of 2.00 mm thick CRCA epoxy power painted by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces.The panel shall consists bus bar of high conductivity aluminium for phases and half for neutral and shall be provided with colour coded shrinkable sleeves. incuding bottom alloy for phases and half for neutral and shall be provided with colour coded heat shrinkable sleeves Including bottom gland plate consisting of sufficient nos of circular cable entry holes at bottom with suitable PVC/rubber bushes to prevent ingress of water/vermin etc. inside the enclosures the required no of holes to be fixed with chromium plated brass cable glands for incoming and outgoing cables, with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size including connection. The panel shall be provided with separate compartments for each switch gear etc with double stud hinged door, front openable with locking arrangement and suitable for 1100 volts grade, 3 phase 415 volts, 50 cycles, AC supply protection shall be IP 48. The panel shall be fixed with angle iron frame made of angles of suitable size comprising the following and :-
(a) Bus bar of aluminium strips of 300 Amps currently capacity TPN, of length as actually required at site for 3 phase and half size neutral, mounted on epoxy/FRP bus bar insulators- 01 No
(b) MCCB 200 Amps, 415V, 4 Pole, 36 KA with thermal magnetic release conf to IS/IEC60947-2&IEC60947-2 - 01 No (incoming)
(c) MCB 63 Amps, 4 pole, 10 KA. 'C' Series- 09 No.(outgoing)
(d) MCB 20 Amps, 2 pole (SPN) 10 KA 'C' Series- 02 No. (outgoing)
(e) LED type indicator lamp- 03 Nos
(f) Internal wiring with suitable size copper conductor PVC insulated heavy duty cable complete -01 Job.
(h) Ammeter 0-200 Amps with suitable CT's -01 Nos
(i) Voltmeter 0-500 Volts - 01 No
Design, Fabricate, Supply & Install, Testing & Commissioning factory made, CPRI approved, LT Feeder Pillar box made of 3.15 mm CRCA sheet, powder coated, self supporting Outdoor type fabricated out of 3.15mm thik CRCA sheet and 40 mm x 40mm x 6mm angle iron frame, weather proof ventilated with locking arrangements IP 52, duly painted with powder coated paint (7 tank process) including of PCC pedestal suitable for 3 phase and 4 wire system comprising the following components:
(a) Aluminium bus bar 300 Amp rated suitable for 3 phase 4 wire system- 01 Set
(b) MCCB FP 250 Amps, 36 KA, 415 Volts, thermal magnetic adjustment of overloaded and short circuit release as per IS/IEC60947-2 & IEC60947-2= 01 No (INCOMING)
(c) MCCB FP 200 Amps, 36 KA, 415 Volts, thermal magnetic adjustment of overloaded and short circuit release as per IS/IEC60947-2 & IEC60947-2= 01 No (O/G for Blg)
(d) MCCB FP 20 Amps, 25 KA, 415 Volts, thermal magnetic adjustment of overloaded and short circuit release as per Conf to IS/IEC60947-2 & IEC60947-2= 01 No No (O/G for lift)
(e) MCB SPN, 10Amps , 240 V, 'C' Series= 01 Nos (for Street Light)
(f) DOL starter suitable 3 Phase, Sunmersible Pump set = 02 Nos
(g) Single Phase Preventer = 02 Nos
(h) Analog Timer Switch, 1 module single phase for street light
(i) Digital Ammeter 0-200 Amps with suitable CTs= 01 Nos
(j) Digital Voltmeter 0-500 Amps = 01 Nos
(k) LED type induction LAMP = 03 Nos
(l) Internal Wiring with suitable size conductor PVC insulated heavy duty cable complete = 01 Job
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 32x6 mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical Main LT panel (Outside the Blgs) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
NOTE:- GI strip and GI pipe 40mm bore medium grade for encasing GI strip beyond 7.50m length per earthing if so required at site shall be measured and paid separately under relevant items
Material & labour for cutting the existing 80mm GI main insertion of tee for tapping out for branch connecting incl connected fittings and necessary excavation, refilling and disposal of surplus material complete all as specified and directed.
S & F 80 mm dia cast iron sluiced valves conforming to IS with ISI mark with SS non rising spindle with double flanges pressure rating PN 01 along with necessary nuts, bolts, gasket etc complete all as specified and directed.
Supply, fixing, testing and commissioning of Submersible Pump Set, 3 Phase, 415 V, 50 Hz of capacity appox 133 LPM at appox 23 m head complete with submersible motor of approved make ISI certified with all electrical wiring, starters and control panel etc and suitable sizes cabling for pump to starter etc. including all necessary suitable suction and discharge pipe, valves, non return valves fittings and connections etc complete all as specified and directed.
Supply and fix Shower rose 150mm dia of MAKE JAQUAR CAT No. OHS-CHR-1801 or equivalent for fixing with 15mm pipe (for Officers Qtrs)complete all as specified and directed.
Supplying ,laying, testing and commissioning XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade LT, confirming to IS 7098 Part I, ISI marked, with and including cable glands, cable lugs etc to suit cable size, laid in trenches, fixed along the poles or through G.I. Pipe laid under floors road etc; fixed concealed in walls encased in G.I. Pipe etc. complete of following sizes:-
(a) Cross sectional area 185 Sqmm, 3.5 core
(b) Cross sectional area 35 Sqmm, 3.5 core
(c) Cross sectional area 25 Sqmm, 3.5 core
(d) Cross sectional area 16 Sqmm, 4 core
(e) Cross sectional area 06 Sqmm, 2 core
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 25 x 4 mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
NOTE:- GI strip and GI pipe 40mm bore medium grade for encasing GI strip beyond 7.50m length per earthing if so required at site shall be measured and paid separately under relevant items
M &L for Construction of brick masonary valve pit chamber of size 900 x 900 x600 mm with 150 mm thick PCC 1:4:8 Type D2 (using 40 mm graded trap stone aggregate) over 15 cm thick hardcore 23 cm thick brick wall buit in cement and sand mortar 1:4, 15 mm thick internal plater including top of floor in extra cement 2mm thick MS sheet cover with 40mm x 40mmx 6mm MS angle frame fixed in PCC 1:2;4 type B1 coping with 25mm x 6mm flat iron holdfasts with handle and locking arrangement, including necessary excavation, filling in soil and disposal of surplus soil at a distance of n exe 50 mtr complete all as shown in drg No. specified and directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 20 x 3 mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main DG panel & AMF panel (outside the blds) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
NOTE:- GI strip and GI pipe 40mm bore medium grade for encasing GI strip beyond 7.50m length per earthing if so required at site shall be measured and paid separately under relevant items
Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 20 KVA 3 -phase 0.8 power factor 50 Hz, 1500 RPM self exicited self regulated brshless AC generator installed including accoustic enclosure with AMF panel, suitable for ambient condition at Pune and confirming to condition under IS 4722, 10001/10002, 13364, BS 5514/2613/5000 with following :-
(A). Alternator :- Standard design alternator rated at 20 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000, IS: 13364 and shall be in position to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
i) Insualation class - 'H'
ii) Temparature rise Class - 'H'
iii) Excitation : Self Excited
iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% .
v) Frequency regulation + 1%
(B) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS -10001/10002/ 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
i) Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts.
iii) Cooling Water pump :
iv) Exhaust System :- Exhaust System complete with exhaust piping upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre.
Exhaust gas turbo charger type
Exhaust manifold
Silecer : Residual type
Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequecy regulation.
Fuel fileters
Fuel hoses
v) Lub oil System :-
Lubricating oil filter
Lubricating oil pump
vi) Air Intake System :-
Air intake Manifold
Air cleanler dry type
vii) Governer electronic / (as recommended by OEM)
viii) Starting System :- Electric Self starter with and including battary charging alternator.
ix) Battaries :- Battaries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified and :
Starter gear ring
Start and stop push button
Ignition key / Switch
Handling and operation : Salient features of accessories shall be as under:
Radiator with blower fan
Corrosion inhibitor coolant
Paper element filters for fuel, lub oil and by pass.
Governer electronic (as recommended by OEM) controlled direct fuel injection system
Fly wheel housing and fly wheel.
x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display.
xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine.
xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling.
xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames as per (as recommended by OEM)
xiv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
xv) Fuel Tank :- Daily service fuel tank (as recommended by OEM) with caliberated level indicating arrangement, stop cock, drain plug, complete on a common base in side the accoustic enclosure.
C) Rubber Matting of LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided.
D) Accoustic Enclosure:- Manufactured by OEM suitable for 20 KVA DG Set.
(i) NAL approved as per CPCB
(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.
(iii) The generating set battaries and control panel should be inside the enclosure.
(iv) Fuel tank should be in side the enclosure.
(v) Construction Details/specification are as follows : -
a) Outer body :- CRCA Sheet of 1.6mm thick.
b) Doors :- CRCA sheet of 1.6 mm thick
c) Sound Insulation :- 100 mm thick rock wool (64kg/Cum)
vi) The accoustic should be composite in construction and fully assembled integral unit.
vii) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulated plat form.
viii) The DG Set should be provided with external Emergency stop push button.
ix) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings.
x) The noise level should be 75 Db at 1m under free field conditions.
xi) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade shall be Genset Green. The base frame should be painted with epoxy based black shade.
x) AMF with microprocessor based Relay Control Circuit, 4 pole MCCB 100Amp 415 V, 25 KA, for main supply and DG set supply with HRC back up fuse complete with all DC control relays/ Line Voltage monitor (LVM) as per OEM specifications incorporationg Engine start, stop three attempt starting facility and failure to start etc.
xii) Digital Frequency meter
xiii) Digital KWH meter
xiv) Digital Power Factor meter (-1.0 to +1.0)
xv) Current Transformers of suitable CT ratio
xvi) Indicating Lamp for supply 'ON' and load 'ON'
xvii) Instrument fuses (HRC type)
xviii) Push button 01 No each for start, stop, and re-set
xix) AL busbar of capacity 200 Amp for phases and neutral
xx) Bottom gland plate including glands for incoming and outgoing LT cables
xxi) Circuit diagram plate
xxii) KWH meter Digital type
xxiii) Instrument fuses HRC type
Notes :- (i) The capacity of Generator set shall be net after all due derating factors as per relevant IS design. (ii) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator to the Panel all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and FOL for final successful acceptance test. (iv) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (v) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests. (vi) All civil works including PCC platform and foundations work required for panel and equipments including making good during installation and commissioning of genset as per manufacturer instructions are deemed included in contractor's quoted rate. The depth of the foundation and PCC shall be provided as per recommendations of the manufacturer.
S&F ISI marked Stationary type electric water heater closed/vented type, inner body made out of copper of capacity 25 Liters suitable for 230 Volts, singles phase AC 50 HZ. Supply ISI Star (5 Star Rating) complete with all accessories and fittings as per requirement.
S&F non return valve chromium plated brass 20 mm dia conforming to IS specifications all as specified and directed.
Supply, install, testing & commissioning for 13 Passengers/884 kg lift suitable to serve 5 (G+4) storey with AC variable voltage & variable frequency AC-VVVF drive with closed loop complete with all standard accessories, Simplex down collective , operation with/without attendant, stainless steel doors with door drive (electric motor driven mechanism), stainless steel doors with hairline finish , automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, The lift shall be machine roomless type and near Ground floor landing door) complete all as specified below:- (Make : Kone/Schnider/Kinetic Hyundai elevator & movement technologies/Hitachi Lifts/Mistubishi Elevators/Otis/Fujitech. Note: Contractor to submit detailed construction drawing of lift being provided with complete technical specification as per IS:14665 (latest revesion) before execution of this work.
(a) Type of Lift : 13 Passenger
(b) Load capacity : 884 Kg
(c) Speed : 1.5 mtr/sec with single speed motor
(d) Power Supply : 400 volts, 3 phase, 4 wire AC, 50 Hz
(e) Type of Drive : AC variable voltage & variable frequency
(f) Type of Machine : Gearless.
(g) Suitable Car size as per IS;14665
(h) Hoistway required : 2500 mm wide x 1900 mm deep
(j) Overhead and pit required : 4250 mm minimum and 1500mm
(K) Car door : Telescopic opening power door, Stainless steel doors with hairline finish ( N-304) , for car & landing at all floor.
(l) Car enclosure : Standard manufacturing with MS frame & stainless steel, in powder coated finish, standard thickness with 2x9 watts LED Light fitting on ceiling coveredwith translucent acrylic cover fitted with power coated Al grill, and also vertical down light suitable for LED lamp and covered and stainless steel wire mesh .
(m) Terminal buffers : Special spring buffers
(n) Door opening (Inside) : Protected by centre opening powder coated finish doors with clear opening about 900 mm.
(o) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design
(p) Flooring : Marbonite/ Granite 10 mm thick
(q) Signals:-
(i) Combined Gein hall buttons with 16 segment at all floors.
(ii) 16 Segment Digital car position indicator combined with direction arrows, overload warning indicator / Hall lantern in car of stainless steel
(iii) One No car operating panel with touch screen buttons in car
(iv) Car direction indicator in car & landing
(v) Battery operated alarm bell & emergency light (rechargeable) alongwith suitable maintenance free battery
(vi) Overload warning feature in car
(vii) Fireman’s switch one No per lift to be installed at G Floor near landing door to be installed at ground floor near landing door.
(viii) All signal fixture & car operating panel on stainless steel face plate
(ix) 3D, Infra red sensor safety edge of door for entire height.
(x) Built in annoucing system without hand set , 2 Nos one one each for car and Ground floor and with one hand set in machine room.
(xi) The interior of the car shall be provided with a device that audibly indicates the floor lift car has reached and indicates that car entrance/exit door is open or closed.
(r) Stops & Opening : 5-5 (All opening on same side)
(s) Safety device : As per OEM Design Automatic resue device (ARD)/automatic landing device all as specified .
(t) Operation : Simplex down collective , operation with/without attendant
(u) Two Separate earthing complete all as specified in SSR Part-I , Plate No.3 and with Aluminum strip of size 25x3.25mm from ground to Lift machine room to be terminated to the control panel , machine and other equipment installed in machine room.
(v) Machine Room : Loacated above the hoist way
(w) Hoist-Way Constn : RCC wall constn as existing at site internal dimension 2000mm x 3000mm. Total height from G/L to slab of Machine room – As existing at site ( Tenderer to inspect the same at site before quoting )
(x) AC VVVF drive
(y) Control system shall be closed loop type
(z) Door shall have ACVVVF controlled door operator
aa) Faceplate shape shall be Rectangular and stainless steel in Hairline Finish.
(ab) Civil work : Necessary Civil work such as making good disturbed surfaces, modification to landing space suitable to car size, necessary foundation to machine etc and one white wash coat in the lift shaft after completion of lift installation .
Supply and installed MCCB, 4 Pole, 250 Amps, 415 Volts AC 50 Hz, 36KA including SS enclosure with connection, complete with all as specified and directed (Tapping Point).
Supply and fix street light fitting complete with 25 watt LED, light fitting including LED bulb, road lighting luminaires with high power LED and unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free services, housing high pressure die cast aluminum, including 1.5 sqmm 3 core copper cable flexible, from looping box to fitting complete with all as specified and directed. Make- Cat No. LTO-25-CDL of Crompton or Equivalent to Bajaj/Wicro/Asian/Philips
Supplying and fixing pole mounted looping box FRP type of size 280x170x105mm suitable for 3-phase connection with locking arrangement including necessary nuts, bolts and clamps complete all as specified and directed comprising of the following complete
(a) Bus bar linked with suitable insulator= 04 Nos
(b) MCB SP 6 Amps with proper fixing arrangement= 01 Nos
Horizon Construction
ganesh electricals and airconditioners
L.K.R.TIWARI CONSTRUCTION
Suma Construction
SHAILENDRA B TULSANI
United Sales Corporation
DARSHAN CONSTRUCTION Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .