Ge West Agra
Garrison Engineer West 62 Station Road Agra Cantt
REPAIR AND REPLACEMENT OF COOLING APPLIANCES (SPLIT/ WINDOW TYPE AC, WATER COOLER, FRIDGE, DEEP FREEZER ETC WITH MISC E/M WORKS UNDER AGE E/M (W) OF GE (W) AGRA
2023_MES_586951_1
8012/946/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹70,000
14 Aug 2023
24 Mar 2023
1 May 2023
24 Mar 2023
29 Apr 2023
1 Apr 2023
Amount
Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer in charge.
Taking down for servicing of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer in charge. Notes for Ser Item No 1 & 2 :- (i) Replacement of defective spares for making the AC units in satisfactory working condition will be measured & paid separately under relevant items and Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. (ii) Penalty will be charged for not attending complaint from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues. (iii) Cost of minor items such as nuts,bolts,washers,screws clips saddles oil,grease rubber gaskets etc as required at site to be incuded in unit quoted rates of items/jobs, & mechanic should be in position of all type of equipments. (iv) Location and place of complaints shall be as per requirement of maintenance work under GE (W) Agra as directed by Engineer in charge/ JE concerned.. (v) Contractor shall be responsible to provide conveyence and required T&P for attend the complaints.
Supply only running capacitor of 45+5 MFD capacity complete all specified and as directed by Engineer in charge
Supply only running capacitor of 50+6 MFD capacity complete all specified and as directed by Engineer in charge
Supply only starting capacitor of 80-100 MFD capacity complete all specified and as directed by Engineer in charge
Supply only starting capacitor of 100-120 MFD capacity complete all specified and as directed by Engineer in charge
Supply only running capacitor of 60+6 MFD capacity complete all specified and as directed by Engineer in charge
Supply only running capacitor of 60+2 MFD capacity complete all specified and as directed by Engineer in charge
Supply only running capacitor of 55+6 MFD capacity complete all specified and as directed by Engineer in charge.
Supply only running capacitor of 55+2 MFD capacity complete all specified and as directed by Engineer in charge.
Supply only running capacitor of 50+2 MFD capacity complete all specified and as directed by Engineer in charge.
Supply only running capacitor of 45 +2 MFD capacity complete all specified and as directed by Engineer in charge.
Supply only starting relay 1622 suitable for any type AC of 1.5 TR/2 TR capacity complete all specified and as directed by Engineer in charge.
Supply only starting relay 2000 suitable for any type AC of 1.5 TR/2 TR capacity complete all specified and as directed by Engineer in charge.
Supply only overload relay suitable for any type AC of 1.5 TR/2 TR capacity complete all specified and as directed by Engineer in charge.
Supply only thermostat switch (2059/2064/2054) adjustable type with Knob suitable for any type AC of capacity 1.5 TR / 2 TR complete all specified and as directed by Engineer in charge.
Supply only aluminium / hard PVC condenser fan blade of blower motor suitable for window type AC of 1.5 TR / 2 TR capacity complete all specified and as directed by Engineer in charge
Supply only aluminium / hard PVC condenser fan blade of blower motor suitable for split type AC of 1.5 TR / 2 TR capacity complete all specified and as directed by Engineer in charge.
Supply only Wiring kit for Window/split type AC of Capacity 1.5 TR/2 TR capacity complete all specified and as directed by Engineer in charge.
Supply only Remote control compatible for split AC of Cap 1.5/2 TR of any make and model as per site requirement complete all specified and as directed by Engineer in charge.
Supply only swing motor as per existing type and model for any type AC complete all specified and as directed by Engineer in charge.
Supply only plazma filters of window type AC/Split AC of capacity 1.5 TR/ 2 TR of any make, dismantling and cleaning the unit with air blower including replacement of air filter complete all specified and as directed by Engineer in charge.
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split AC of capacity 1.5/2 TR complete all specified and as directed by Engineer in charge.
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for window AC of capacity 1.5/2 TR complete all specified and as directed by Engineer in charge.
Supply & fixing in repairs plastic louvers for (Front panel) for Window AC 1.5/2 TR complete all specified and as directed by Engineer in charge.
Supply & fixing in repairs of suction and discharge valve set of size 15mm (5/8''), 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5/2 TR capacity complete all specified and as directed by Engineer in charge. Note:- (i) 15mm (5/8'') or 6mm (1/4'') and 12mm (1/2'') made one set (ii) Supply & filling of refrigerant gas shall be measured and paid under relevent item.
Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all specified and as directed by Engineer in charge.
Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all specified and as directed by Engineer in charge.
Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5 / 2 TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all specified and as directed by Engineer in charge.
Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all specified and as directed by Engineer in charge. (Note:- Supply & filling of refrigerant gas shall be measured and paid under relevent item.)
-ditto- all as per item No. 30 above but spilt/window type Air Conditioner of capacity 2 TR complete all specified and as directed by Engineer in charge.
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/ R-32 and commissioning complete all specified and as directed by Engineer in charge.
All as per item No 32 here-in-before but of 1.5 TR capacity complete all specified and as directed by Engineer in charge.
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the Split type Air Conditioner of Cap 1.5 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-134a/R-32 and commissioning complete all specified and as directed by Engineer in charge.
All as per item No 34 here-in-before but of 2.0 TR capacity complete all specified and as directed by Engineer in charge. Note for Item No 32 to 34 (i) Refrigerant gas will be measured and paid saperatlt under respactive item here in after. (ii) Compressor should be accompanied by Purchase voucher from authorised dealer of manufacturer and manufacturer's test certificate. (iii) Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Supply & fixing in repairs of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all specified and as directed by Engineer in charge.
Supply & fixing in repair copper wounded Indoor Air blower motor for Split AC 1.5/2 TR capacity complete all specified and as directed by Engineer in charge.
Supply & fixing in repairs of copper wounded condenser fan motor for Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all specified and as directed by Engineer in charge.
Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 39 above but spilt type Air Conditioner Capacity 1.5/ 2 TR complete all specified and as directed by Engineer in charge.
Supply & fixing in repairs of evaporator/cooling coil for window type Air Conditioner of capacity 1.5/ 2TR of existing make and size complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 41 above but spilt type Air Conditioner Capacity 1.5/ 2 TR complete all specified and as directed by Engineer in charge.
Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 43 above but spilt type Air Conditioner of capacity 2 TR complete all specified and as directed by Engineer in charge.
Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 45 above but spilt type Air Conditioner of capacity 2 TR complete all specified and as directed by Engineer in charge.
Supply & fixing heavy duty copper pipe 6 mm (1/4") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 47 above but copper pipe 12 mm (1/2") dia/ bore complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 47 above but copper pipe 15mm (5/8") dia/ bore complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 47 above but copper pipe 18mm (3/8") dia/ bore complete all specified and as directed by Engineer in charge.
Taking down unserviceable flexible PUF form type insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 & 2.0 TR complete all specified and as directed by Engineer in charge.
Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC complete all specified and as directed by Engineer in charge.
Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC of capacity 1.5 / 2 TR complete all specified and as directed by Engineer in charge.
Dismantling and removing defective burnt blower unit motor of any capacity and make of 1.5/2 TR capacity window type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all specified and as directed by Engineer in charge.
Dismantling and removing defective burnt blower unit motor of any capacity and make of indoor units of split type AC of capacity 1.5/2 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all specified and as directed by Engineer in charge.
Dismantling and removing defective burnt outdoor unit motor of any capacity and make of indoor units of split type AC of capacity 1.5/2 TR capacity rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete all specified and as directed by Engineer in charge..
Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all specified and as directed by Engineer in charge.
Supply and fixing in repairs of 1.5 TR capacity window type AC kit including condenser & evaporator coil (copper), copper wounded blower motor, chasis base plate, reverse valve, capacitor and copper pipes & PVC wires of suitable size for internal connection except compressor etc ready to install & suitable for use in cold and hot mode with remote including taking down old one complete all specified and as directed by Engineer in charge.
Dismantling and Refixing the Split type AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with Outdoor Unit’s pipes and Connecting indoor and outdoor units with copper pipes and installation of drainage pipes and Fixing Outdoor unit on separately ODU stand, Temperature & gas pressure testing, gas charging, Carpentry work, Plumbing, masonry & white cementing Note : Drain Pipe, Copper of required size, Refrigerent gas , Outdoor stand , power plug, MCB and Copper wire to be paid under relevent item)
Dismantling and Refixing the window type AC of 1.5/2 TR Including Drilling of holes into a brick wall for connecting Indoor with Outdoor Unit’s pipes and Connecting indoor and outdoor units with copper pipes and installation of drainage pipes and Fixing Outdoor unit on separately ODU stand, Temperature & gas pressure testing, gas charging, Carpentry work, Plumbing, masonry & white cementing Note : Drain Pipe, Copper of required size, Refrigerent gas , Outdoor stand , power plug, MCB and Copper wire to be paid under relevent item)
Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unservisible sub main wiring complete all specified and as directed by Engineer in charge.
-ditto- all as per item no 61 but 2.5 sqmm (nominal area) complete all specified and as directed by Engineer in charge. Notes for item No.60 & 61 :- (i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.
Supply and fixing in repairs of metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps iincluding taking down old unservisible metal clad socket complete all specified and as directed by Engineer in charge.
Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all specified and as directed by Engineer in charge.
Supply & fixing in repair metal clad socket of 20 Amps complete all specified and as directed by Engineer in charge.
Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all specified and as directed by Engineer in charge.
Taking down/ Collecting of unserviceable voltage stabilizer of capacity 0.5 to 5 KVA from the MES store yard of AGE AC(OTBH) or dismantling the same from site and transporting to contractors workshop for locating the fault including checking the serviceability of electrical/electronic circuits relays and replacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all specified and as directed by Engineer in charge. Note :- 1. Replacement of defective spares and rewinding of transformer of voltage stabilizer will be measured & paid separately under relevant items and Labour charges for taking out old spares & fixing of new spares shall deemed to be included in unit rate quoted.
Supply only Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply.
Supply only Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply.
Supply only Printer circuit board (PCB) control card suitable for 0.5 to 5 KVA complete all specified and as directed by Engineer in charge.
Supply only Input/output switch complete all specified and as directed by Engineer in charge.
Supply only Push on switch complete all specified and as directed by Engineer in charge.
Supply only Indicator light complete with bulbs complete all specified and as directed by Engineer in charge.
Supply only Trigger Transformer for 1 to 5 KVA complete all specified and as directed by Engineer in charge.
Supply only Relay for 0.5 to 5 KVA voltage stablizer complete all specified and as directed by Engineer in charge.
Supply only Time delay and High/low voltage cut off circuit with relay suitable for 0.5 KVA to 5 KVA complete all specified and as directed by Engineer in charge.
Taking out burnt components of auxiliary PCB of voltage stabilizer of 4.0/5.0 KVA capacity and re-fixing back in original position after making it serviceable/repair complete all specified and as directed by Engineer in charge.
All as per item No 77 above but for 0.5/2 KVA capacity voltage stabilizer complete all specified and as directed by Engineer in charge.
Supply only auxiliary transformer of voltage stabilizer of 4.0/5.0 KVA capacity complete all specified and as directed by Engineer in charge.
All as per item No 79 above but for 0.5/2 KVA capacity voltage stabilizer complete all specified and as directed by Engineer in charge.
Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 0.5 KVA voltage stabilizer, complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 81 here-in-before but 1 KVA complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 81 here-in-before but 2 KVA complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 81 here-in-before but 4 KVA complete all specified and as directed by Engineer in charge.
-ditto- all as per item No. 81 here-in-before but 5 KVA complete all specified and as directed by Engineer in charge.
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all specified and as directed by Engineer in charge. Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Supply only over load protector relay suitable for 40/80, 60/120 & 150/150 Ltrs capacity water coolers complete all specified and as directed by Engineer in charge.
Supply only thermostat suitable for 40/80, 60/120, 150/150 Ltr capacity water coolers complete all specified and as directed by Engineer in charge.
Supply only condenser motor fan blade suitable for 40/80, 60/120, 150/150 Ltr capacity water coolers complete all specified and as directed by Engineer in charge.
Supply only PVC flexible drain Hose Pipe 40 mm complete all specified and as directed by Engineer in charge.
Supply only Waste water tray complete suitable for 40/80, 60/120, 150/150 Ltr capacity water coolers complete all specified and as directed by Engineer in charge.
Supply only chromium plated push taps suitable for 40/80/120/150 Ltr capacity water coolers complete all specified and as directed by Engineer in charge.
Supply only PVC float valve of size 15mm dia complete suitable for 40/80/120/150 Ltr capacity water coolers including GI socket of same size complete all specified and as directed by Engineer in charge.
Supply only starting capacitor of 40-60 MFD capacity for water cooler any capacity complete all specified and as directed by Engineer in charge.
Supply only starting capacitor of 25 MFD capacity for water cooler any capacity complete all specified and as directed by Engineer in charge.
Supply only running capacitor of 10 to 40 MFD capacity complete all specified and as directed by Engineer in charge.
Supply only Starting relay suitable for 40/80, 60/120, 150/150 Ltr complete all specified and as directed by Engineer in charge.
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap.60/120, 150/150 Ltr and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all specified and as directed by Engineer in charge.
All as per item No.98 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs complete all specified and as directed by Engineer in charge.
Dismanling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-134A, commissioning and testing Water Coolers of 40/80 Ltrs capacity complete all specified and as directed by Engineer in charge.
All as per item No.100 above but Water Coolers of 60/120 Ltrs capacity complete all specified and as directed by Engineer in charge.
All as per item No.101 above but Water Coolers of 150/150 Ltrs capacity complete all as specified and directed. Note for item Nos 99 to 101:- (i) Refrigerant gas will be measured and paid saperatlt under respactive item here in after. (ii) Compressor should be accompanied by Purchase voucher from authorised dealer of manufacturer and manufacturer's test certificate. (iii) Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 60/120, 150/150 Ltrs complete all specified and as directed by Engineer in charge..
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Ltrs complete all specified and as directed by Engineer in charge.
Dismantling the evaporator/cooling coil of water cooler capacity 150/150, 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner complete all specified and as directed by Engineer in charge.
Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all specified and as directed by Engineer in charge.
M&L for cutting and removing the rusted/ worn out portions of the water cooler bottom / base of any make/ size and making new base with MS sheet and angle iron of the existing gauge and size, including provision of standing legs made either with sheets or angle iron and also carried out two coats of black synthetic enameled paint over a coat of red oxide complete all specified and as directed by Engineer in charge.
Dismantling of existing repairable Refrigerators of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, complete all specified and as directed by Engineer in charge. Note :- Parts renewed shall be measured and paid separately under appropriate items.
Supply only capillary tube of existing size including necessary brazing suitable for 165 to 320 Ltrs capacity refrigerator, including dismantling the old unserviceable one complete all specified and as directed by Engineer in charge.
Supply only over load/starting relay kit suitable for 165-320 ltrs capacity refrigerator of approved make and testing complete all specified and as directed by Engineer in charge.
Supply only thermostat switch suitable for 165 to 320 Ltr capacity refrigerator of approved make complete all specified and as directed by Engineer in charge.
Supply only vegitable tray made out of high quality PVC / plastic, clear transparent type suitable for 165 to 320 Ltrs capacity refrigerator of approve quality/ make complete all specified and as directed by Engineer in charge.
Supply only PVC defrost tray as per sample suitable of 165 to 330 Ltrs capacity refrigerators of approve quality/ make complete all specified and as directed by Engineer in charge.
Supply only magnetic type door gasket suitable for 165 to 310 Ltrs capacity of approve quality/ make of refrigerator complete all specified and as directed by Engineer in charge.
Supply only timer for frost free refrigerator (Self defrosting type) of capacity 280 to 310 ltrs capacity, suitable for LG / Samsung make refrigerators complete all specified and as directed by Engineer in charge.
Supply only sensor switch for frost free refrigerator (Self defrosting type) of capacity 280 to 310 ltrs capacity, suitable for LG / Samsung make refrigerators complete all specified and as directed by Engineer in charge.
Dismanling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 165 to 210 Ltrs capacity complete all specified and as directed by Engineer in charge.
Dismanling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-22/134A, commissioning and testing refrigerators of 280 to 330 Ltrs capacity complete all specified and as directed by Engineer in charge. Note for Item No 116 & 117:- (i) Refrigerant gas will be measured and paid saperatlt under respactive item here in after. (ii) Compressor should be accompanied by Purchase voucher from authorised dealer of manufacturer and manufacturer's test certificate. (iii) Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Dismantling of existing repairable deep freezers/ water dispanser of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop fro carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed. Note :- Parts renewed shall be measured and paid separately under appropriate items complete all specified and as directed by Engineer in charge.
M & L for detection of leakage of deep freezer inside the cabinet/puf/insulated body including changing new condenser/Puf of complete deep freezer of capacity 300 ltrs and make it functional complete all specified and as directed by Engineer in charge.
Supply only starting relay 1/6 HP open with OLP complete all specified and as directed by Engineer in charge.
Supply only starting relay for 1/8 HP open type with OLP all as specified and directed.
Supply only over load protector suitable for upto 500 Ltrs capacity deep freezer complete all specified and as directed by Engineer in charge.
M & L for detection of leakage of deep freezer inside the cabinet/puf/insulated body including changing new condenser/Puf of complete deep freezer of capacity 300 ltrs and make it functional complete all specified and as directed by Engineer in charge.
Supply only thermostat suitable for upto 500 Ltrs capacity deep freezer complete all specified and as directed by Engineer in charge.
Supply only Axial Fan for deep freezers complete all specified and as directed by Engineer in charge.
Taking down defective compressor of deep freezer of capacity Upto 280/300 Ltrs and any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant gas Non CFC based or equivalent to Non CFC gas in required qty and testing complete all specified and as directed by Engineer in charge. Note:- (i) Refrigerant gas will be measured and paid saperatlt under respactive item here in after. (ii) Compressor should be accompanied by Purchase voucher from authorised dealer of manufacturer and manufacturer's test certificate. (iii) Transportation Charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
Supply and fixing in repairs new PCB suitable for LG (Dual inverter)/Hitachi/Voltas/Panasonic make inverter ACs of capacity 1.5/2 TR complete all as specified and directed.
M&L for disconnecting the unserviceable PCBs from existing LG (Dual inverter)/Hitachi/Voltas/ Panasonic make Inverter ACs of capacity 1.5/2 TR, and re-fixing after necessary repair for satisfactory functioning of the AC unit complete all specified and as directed by Engineer in charge.
M&L for disconnecting the unserviceable DC condensor fan motor of outdoor units and Supply, fixing & testing for proper functioning of existing LG (Dual inverter)/Hitachi/Voltas/Panasonic make Inverter ACs of capacity 1.5/2 TR complete all specified and as directed by Engineer in charge.
M&L for disconnecting the unserviceable DC blower fan motor of Indoor units and Supply, fixing & testing for proper functioning of existing LG (Dual inverter)/Hitachi/Voltas/Panasonic make Inverter ACs of capacity 1.5/2 TR complete all specified and as directed by Engineer in charge.
Supply only refrigerant gas M-22 in cylinders of required capacity including transportation, loading and unloading charges for collection of empty cylinders from MES store yard of AGE E/M, returning the same cylinder or other cylinder after refilling and testing of cylinders including test certificate by authorised agencies complete all specified and as directed by Engineer in charge.
All as per item No 132 above but refrigerant Gas M-134(a) complete all specified and as directed by Engineer in charge.
All as per item No 132 above but refrigerant Gas R-32 complete all specified and as directed by Engineer in charge.
All as per item No 132 above but refrigerant Gas R-410 complete all specified and as directed by Engineer in charge.
All as per item No 132 above but refrigerant Gas M-600 complete all specified and as directed by Engineer in charge.
Supply only flexible copper conductor cable PVC insulated & PVC sheathed of size 4.0 Sqmm or (40/0.0076), 1100 Volt grade 3 core complete all specified and as directed by Engineer in charge.
Supply only flexible copper conductor cable PVC insulated & PVC sheathed of size 2.5 Sqmm or(23/0.0076), 1100 Volt grade 4 core complete all specified and as directed by Engineer in charge.
M & L for repairing the refrigerator or water cooler body by cutting the worn out/ rusted/damaged portion of body with the help of gas welding and jointing the pieces of 18 gauge MS sheet with gas welding as required and making the surface smooth to match the existing surface by grinding and then applying two coats of Ducco paint with spray machine over one coat of red oxide primer complete all specified and as directed by Engineer in charge.
H.S.Kochhar n Sons
M/S J J ENTERPRISES
M/s SCHOLASTIC ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .