Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹36.8 L+₹87,623.01 (2.44%)Rejected-AOC VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC NOT ACCEPTED | |
| 3 | L3₹36.9 L+₹99,950.06 (2.78%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED | |
| 4 | L4₹37.6 L+₹1.8 L (4.89%)Rejected-AOC 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC NOT ACCEPTED | |
| 5 | L5₹40.8 L+₹4.9 L (13.6%)Rejected-AOC | L5 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹41.1 L
EMD Value
₹82,300
Closing Date
29 Jan 2020, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR C/0 56 APO
PROVN OF SECURITY WALL SEPTIC TANK AND HARD STANDING NEAR BLDG NO P 1 AT TA GROUP HQ WATER HEATING SYS WITH ALLIED INFRA FOR NCCIU ROOF TREATMENT IN BLDG NO P 74 AT HQ NC ADDN/ALTN OF ROOF AND PROVN OF FALSE CEILING IN BLDG NO NP21 AND NP23 AT I WKS
2019_MES_307604_1
GE/S(U)-55/2019-20
Open Tender
Civil Works
Item Rate
240 days
NCCIU HQNC (I) WKSP
REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH UDHAMPUR
₹82,300
Yes
3 Jun 2020
19 Dec 2019
31 Jan 2020
19 Dec 2019
29 Jan 2020
15 Jan 2020
19 Dec 2019 - 31 Dec 2019
Amount
Rough excavation not exceeding 1.5 mtr deep and getting out in any type of soil complete all as specified and directed.
Excavation over areas not exceeding 1.5 m and not exceeding 3.00 m in depth getting out as in soft/loose soil complete all as specified and directed.
PCC (1:4:8) type-D-2 (using 40 mm graded stone aggregate) as in foundations and mass concrete complete all as specified and directed.
Brick work with sub class "B" bricks straight or curved on plan exceeding 6 Metre mean radius in cement mortar 1:6 complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing excavated material exceeding 250 m but not exceeding 500 m and deposited where complete all as specified and directed.
Form work to sides of concrete foundation footings, base of columns,raft and raft beams,sides and soffits (if any) of foundation and plinth beams,and similar work vertical or to batter rough finished flat surfaces complete all as specified and directed.
Form work to faces of walls,retaining walls,abutments,parapets and staircase railings and similar work including attached pillasteres,buttresses etc vertical ot to batter etc rough finished surfaces complete all as specified and directed.
Form work to sides of pillars,posts,struts,piers,columns,and stanchions etc rough finished surfaces complete all as specified and directed.
RCC M-25 design mix, (using 20 mm graded stone aggregate) as in foundation ,including rafts, footings, foundation beams,plinth beams ,bases for columns,etc basement slabs,under-reamed piles and mass concrete complete all as specified and directed.
RCC M-25 design mix, (using 20 mm graded stone aggregate) as in walls, retaining walls, basement walls, ballast walls and the like any thickness above top of footing including attached pilasters and buttresses complete all as specified and directed.
RCC M 25 design mix, (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over cut to lenth, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia as in reinforcement cut to length, bent to shae required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (anealed not less than 0.9 mm dia) complete all as specified and directed.
Rendering 15 mm thick in cement mortar 1:4 on fair faces of concrete surfaces finished fair and even without using extra cement complete all as specified and directed.
RCC 1:1.5:3 type A-1 (using 20 mm graded aggregate) as in beams, lintels complete all as specified and directed.
Form work to sides and soffits of floor or roof beams, lintels etc rough finished surfaces complete all as specified and directed.
Boulder pitching is grouted with cement and sand mortar 1:6 hand packed tightely complete all as specified and directed.
Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars and similar work confirming to E-250 complete all as specified and directed.
Mild steel confirming to grade Fe-165 (Fe-290) angle post or struts in fencing fixed independently including cutting and bending to shape as directed drilling holes, notching for wire etc. complete all as specified and directed.
Preparation of new plastered surfaces and applying two coats of cement based paint over a coat of chalk whiting complete all as specified and directed.
Preparation of new steel surfaces of any description over 10 cm idth or girth and applying two coat of synthetic enamel paint over a coat of red oxide chrome primer complete all as specified and directed.
Punched tape concertina coil (including spike and handle) with 50 turns and 1050 mm dia, width of barbed 9 mm dia and spacing of clips 23.5 mm to 24.5 mm c/c weight of coil will be 10 to 14 kg without packing. Coil length will be 6 m when opened up etc complete all as specified and directed.
Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of post including securing and tying at crossing with and provision of galvanised mild steel wire staple or steel pins etc complete all as specified and directed. (Each line wire to be mesured)
Hand packing (any thickness) at back of walls over arches etc and raising (or lowering) to the required level complete all as specified and directed.
110 mm dia PVC (SWR) pipes single socketed in any length as in weep holes of retaining wall all complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation or manholes etc and area not exceeding 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete type D-2 (1:4:8) for 150 mm dia pipe complete all as specified and directed.
SGSW drain pipe grade 'A' of 150 mm internal dia laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:4) as in manholes, septic tank, filter bed, walls, drains etc complete all as specified and directed.
Precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) for manhole cover septic tank covers slabs etc including necessary form work and set in cement mortar (1:4) complete all as specified and directed. Note:- reinforcement will be measured and paid seperately.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm complete all as specified and directed.
PVC (SWR) vent cowl 110 mm dia complete all as specified and directed.
Construction of soakage well 1.8 M dia and 3 Mtr deep including excavation and earth work in any type of soil foundation in PCC 1:3:6 walls of honey combed and solid, M-25 concrete, RCC cover slab and filling with brick bats complete as shown in drgs No.TD CE/TD -1202/2003 sheet No 1/2 and 2/2 dated 09-10-2003 and as directed. Note:- Rate quoted shall deemed inclusive of dewatering during construction if met with.
Removing excavated soil to a distance exceeding 50 m and not exceeding 2.50 km out side defence land complete all as specified and directed by Engr-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard and dense soil complete all as specified and directed.
75 mm thick plain cement concrete type D-2 (1:4:8) (40 mm graded stone aggregates) as in sub base complete all as specified and directed.
Sand cushion 20 to 30 mm thick for fixing of inter locking tiles complete all as specified and directed by Engr-in-Charge.
Machine pressed precast concrete interlocking paver block (glossy finish) of approved shape and size confirming to IS 15658-2006 of 60 mm thickness with grey cement and pigment, M-35 Grade of approved colour and design complete all as specified and directed by Engr-in-Charge.
Cement concrete 1:2:4 type B-1 (20 mm readed stone aggregate) as in coping kerb and similar work etc including necessay form work complete all as specified and directed.
Dismantling AC corrugated sheet as in roof covering complete all as specified and directed.
Dismantling framed work timber scantlings 40 sqcm and over in section, in any position complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards any thickness including cover fillets complete all as specified and directed.
Demolition cement concrete in ground floors and paving (unreinforced) not exceeding 15 cm thickness (below or above ground floor) complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises complete all as specified and directed.
Demolition of Brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pilars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to to common raters and running rails and guides for sliding doors, fixed with angle cleats or other connecting leates Fe 410-W (Gde-E-250) qualiy-A complete all as specified and directed.
Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick crimpted/tapard at the external end slop of any colour having tansile strength 550 Mpa as in roof covering fixed with self tapping screws and caps etc complete all as specified and directed.
Plain galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick in ridges, hips, valley gutters at the external end slop of any colour having tansile strength 550 Mpa as in roof (ridges) covering fixed with self tapping screws and caps etc complete all as specified and directed.
Mild steel screw bolt (machine made) 11 to 15 mm dia with hexagonal or square heads at one end and screw the other, or screwed both end to be fitted with washers and one hexagonal or squre nut exceeding 10 cm and not exceeding 15 cm long complete all as specified and directed.
4 mm thick AC board (designer ceiling) of size 600 mm x 600 mm panel confirming to IS 14862 type B category three including GI frame work with size of grid 605 mm x 605 mm for seanless ceiling comprises of GI perimeter including all accessories complete all as specified and directed.
Screed bed or bedding layers of 15 mm thick cement mortar 1:6 for laying floor finishes complete all as specified and directed.
Backing coat of cement mortar 10 mm thick in 1:3 to receive tiles in vertical surfaces complete all as specified and directed.
25 mm thick PCC type B-0 (using 15 mm graded aggregate) as in sub base for receiving floor finishes complete all as specified and directed.
Vitrified ceramic tiles 10 mm thick (square /rectangular) polished, area of each tiles not exceeding 0.36 sm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per ser item No 55 here in before above but skairting/ dado complete all as specified and directed.
Applying one coat birla wall care putty on old plastered on wall surfaces including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading with oil greasy spot complete all as specified and directed with complete removing.
Preparation of old plstered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
Preparation of old plastered surfaces and applying one coats of distemper oil emulsion over a coat of primer of celing complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
15 mm thick rendering in cement mortar (1:6) on brick or concrete surface complete all as specified and directed.
Applying two coat birla wall care putty on new plastered on wall surfaces including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading with oil greasy spot complete all as specified and directed.
Preparation of new plstered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer including complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking of shutter off shutters from frame) 1.5 sqm not exceeding 4 sqm each complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking of shutter off shutters from frame) not exceeding 1.5 Sqm each complete all as specified and directed.
75 mm thick plain cement concrete, type C-2, (1:3:6) (using 40 mm graded aggregate) as in plinth protection complete all as specified and directed.
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed.
Powder coated Anodised Aluminium frames for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed.
Powder coated aluminium anodised window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary jointing cleat glazing clips, rubber packing, anodised aluminium snap beading screws etc. complete all as specified and directed.
Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium staples complete all as specified and directed.
4 mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 kg/Sqm complete all as specified and directed by Engr-in-Charge.
25 mm thick PCC 1:2:4 type B-1 (using 12.5 mm graded aggregate) as in level course on roof surface complete all as specified and directed.
Rendering 10 mm thick in cement mortar 1:3 mixed with integral water proofing compound as per manufacture's instructions as in roof and chajjas, finished the surface fair and even with out using extra cement complete all as specified and directed. Note : Supply of water proofing compound will be measured and paid separately.
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Min wt of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm including two coats of bituminious alluminium paint complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound complete all as specified and directed.
PCC 1:2:4 using B-0 (using 12.50 mm graded aggregate) for coping, corner of roof and similar work complete all as sepcified and directed.
25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in level course on floor etc complete all as specified and directed.
Vitrified coloured heavy duty (Dura stone) 300 x 300 x 10 mm thick tiles as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Rendering 5 mm thick in cement mortar 1:3 on ceiling, chajja, roof projection etc finished fair and even without using extra cement complete all as specified and directed.
Preparation of new plastered or un- plastered surfaces and walls including cornices, pilasters etc and applying two Coats of cement base paint over a coat of primer complete all as specified and directed.
Preparation of new plastered or un- plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
Disconnecting existing tanks of exceeding 500 but not exceeding 1000 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position with cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc. complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 1000 ltrs (cylindlerical verrtical with closed top) hoisted and fixed in position complete all as specified and directed in SSR part I inclding dismantling of existing damaged water tanks.
PTMT ball valves 20 mm dia high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes and fixed to iron pipes complete all as specified and directed.
PTMT ball valves 25 mm dia high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes and fixed to iron pipes complete all as specified and directed.
Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and complete all as specified and directed.
Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 25 mm bore and complete all as specified and directed.
Steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, 15 mm bore with all necessary GI fitting including taking down old pipe complete all as specified and directed.
Steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, 20 mm bore with all necessary GI fitting including taking down old pipe complete all as specified and directed.
Steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, 25 mm bore with all necessary GI fitting including taking down old pipe complete all as specified and directed.
Refixing old 15 mm steel tubing and connection in new or old position with all necessary GI fitting (wall, ceiling, floors etc) including taking down old pipe complete all as specified and directed.
Refixing old 20 mm steel tubing and connection in new or old position with all necessary GI fitting (wall, ceiling, floors etc) including taking down old pipe complete all as specified and directed.
Demolition and beaking up drain AC pipes/PVC pipe set in cement mortar 100 mm and below complete all as specified and directed.
110 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
110 mm PVC (SWR)couplers for PVC pipe and similar work complete all as specified and directed.
75 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
75 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
Sand filling under floor or in foundation including watering and consolidation all as specified and directed.
Precast cement concrete (factory made)1:2:4 type B-1 (20 mm graded stone aggregate) set in cement mortar as in road kerbs and similar work etc complete all as specified and directed.
Removing excavated soil/debries to a distance exceeding 50 m and not exceeding 1.50 km out side defence land complete all as specified and directed.
Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1 (20 mm graded crushed stone aggregate), kerb stone & the like of size 300 mm x 300 mm x 100 mm thick or of size as approved by GE, with plain fair faces including chamfers, weathering etc. embedding in position/laid in trenches on edges of roads, including excavation in any type of soil, setting in cement mortar (1:4) returning filling and removal of surplus soil/debris to a distance not exceeding 50 m from the starting point complete all as specified and directed.
Crash barrier consisting of metal frame work with and including supporting angles nut and bolts, PCC as in foundation with and including earth work (Single faced with c/c distance of pole (1.50 to 2.0 mtr), thickness of coil 3.00/2.67 mm and girth 350 mm to 400 mm confirming to Gde Fe 410, IS10748, AASHTO M 180 complete all as specified and directed.
Retro Reflective Tape Hip grade (High Intensity Prismatic) size 4"x12" red and yellow colour with as per Morth specification complete all as specified and directed.
Preparation of new plaster surface of walls and applying two coats of oil bound distempers over one coat of primer and two coat of wall care putty complete all as specified and directed by Engr-in-Charge.
Rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 on vertical surfaces/backing coat complete all as specified and directed.
Glazed ceramic coloured tiles of size 600 x 300 x 7-8 mm wall tiles set and jointed in neat cement and in white/coloured cement to match with the colour of tile etc complete all as specified and directed
Demolition of cement concrete any description and any position not otherwise specifically provided complete all as specified and directed.
Non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Reinforced cement concrete (nominal mix) type B-1 1:2:4 (20 mm graded aggregate) using in beams, cantilevers, bressummers, lintels over 1.5 mtr span and similar work etc complete all as specified and directed.
Form work to sides and soffits of floor or roof beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports overhangs etc complete all as specified and directed.
Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratary with plugs washer and wastes including bedding in cement mortar to drawf wall or including fixing cantiliver brackets and connecting union to pipes overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
Vitreous china bowl urinal flat back, size 465 x 355 x 265 mm white (min) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
Vitreous china ware wash down water closet pan, (pedestal pattern) coloured including connection to drain and to flushing pipe, anti syphonage pipe etc. complete all as specified and directed.
WHB vitreous china (flat back or angle back type ) any size, including cutting for pinning in ends size 550 x 400 mm including brackets, 32 mm CP waste fittings coupling, connection pipe 450 mm long and 15 mm dia CP piller taps fancy type complete all as specified and directed.
10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve float and handle complete all as specified and directed.
Plastic water closet seat, black or white closed pattern, solid type with flat bottom and cover and mild steel chromium plated hinging device (Make CERA) any type of EWC complete all as specified and directed.
Pillar tap cast copper alloy with capstan head, chromium plated screwed down high presure with or with out lettered fixed with iron pipe 15 mm bore complete all as specified and directed.
Bib taps cast copper alloy with crutch or butter fly handle screwed for iron pipe of dia 15 mm fixed complete all as specified and directed.
Steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls,15 mm bore including taking down old pipe complete all as specified and directed.
Demolition of reinforced cement work as in roof slabs (other than ground floors) beams staircases, landing chajjas and similar suspended work complete all as specified and directed.
Reinforced cement concrete (design mix) M-25 (20 mm graded aggregate) as in slab supported on walls, beam and columns in floors, roofs landings, balconies etc. complete all as specified and directed.
Form work to soffits of suspended slabs such as roof, floor slabs, landings etc not exceeding 200 mm thick (horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for laying floor tiles in cement mortar 1:4 complete all as specified and directed.
Non skid ceramic joint free tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm and not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the slurry complete all as specified and directed.
20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Dismantling boarding any description any description fixed in any position with nails complete all as specified and directed.
Dismantling timer scantling over 40 sqcm in section and over in section , in any position complete all as specified and directed.
18/19 mm thick plywood grade "A" (Termite treated/water proof), type "B" fixed with screws to timber/iron frame work complete all as specified and directed. Make : Green Ply/Kit ply.
0.9 mm thick decorative choice of lamination type-1 of surface finish, colour and pattern as approved adhesive as per manufacturers instructions complete all as specified and directed.
2nd class soft wood as in plain solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Stain less steel catcher of superior quality complete all as specified and directed by Engr-in-Charge.
50 mm stain less steel pivoted type hinges of superior quality and complete all as specified and directed by Engr-in-Charge.
Aluminium 65 mm mortice lock four levers complete all as specified and directed. (ISI Marked)
Aluminium anodised barrel tower bolts of extruded section with 75 mm long bolt complete all as specified and directed. (ISI Marked )
Drawer side channel of standard size and including of rooler for moving drawer, mild steel bright finish or electro galavanised width of flap 30 mm and Length 60 mm as in repair complete all as specified and directed.
Stainless steel fancy type, bright finish handles fixed with screw of 125 mm size fixed as in reapir complete all as specified and directed.
Stainless steel multipurpose basket in wooden drawer/partitions for storing rations of various types made of 4 mm dia stainless steel rods, fixed in side partitions etc fixed as in reapir complete all as specified and directed for modular kitchen.
Stainless steel luddle-craddle hanging stand for cutlery complete all as specified and directed by Engineer-in-Charge for modular kitchen.
Stainless steel zero crank hinges (auto) fancy type (with Euro concealed hinges) fixed to shutters in cupboards of standard size and shape for modular kitchen fixed as in reapir complete all as specified and directed by Engr-in-Charge.
1.00 mm thick stainless steel single bowl Sinks with plugs, washers and wastes; including fixing contilever brackets and connecting union to pipe (size of bowl 410 mm x 330 mm x 160 mm) complete all as specified and directed.
Recessed type stain less steel handle for cup boards size 150 mm long complete all as specified and directed.
15 mm bore long body Bib tap complete all as specified and directed. Make : Jaquar, Cat Part No CON-037KN or equivalent in Kohler/Cera
15 mm bore Bib tap complete all as specified and directed. Make : Jaquar, Cat Part No CON 107KN or equivalent in Kohler/Cera
15 mm bore angular stop cock with wall flange complete all as specified and directed. Make : Jaquar, Cat Part No CON-059KN or equivalent in Kohler/Cera
PVC connection 15 mm bore 450 mm long Braided Hose with M10 X 1 Nipple, 15 mm Nut, O-Ring & Rubber washer (Suitable for Basin Mixers) complete all as specified and directed. Make: Jaquar, Cat Part No - ALD-803AB or equivalent in Kohler/Cera
75 mm bore cast iron floor trap with grating including jointing to waster pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and directed.
Dismantling of cast iron or reinforced concrete pipes, jointed in cement mortar pipes up to 100 mm bore in any position complete all as specified and directed.
Providing false ceiling GI frame work for seamless ceiling comprising of GI perimerter channel 0.55 mm thick with two unwqual flages of 20 to 30 mm and web of 27 mm fixed to surrounding wall using screws at 452 mm C/C channel 0.9 mm thick having two wqual flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm C/c with GI cleat and steel expansion or sutable hanging from soffits\trusses\bracking supporting hanger compressing of GI wire complete all as sepcified and directed by Engr-in-Charge.
4 mm thick 600 x 600 mm size asbestos cement plain E-boards designer ceiling (Make: Everest of equivalent), fixed to GI grid work with screws and applying new surfaces two coat of distempers and one coat of primers complete all as specified and directed.
Non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Glazed ceramic coloured tiles of size 300 x 200 mm x 7 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
PVC (SWR) Floor trap, 75 mm dia of outlet, plain with grating including jointing with solvent cement including removing old trap and making good complete all as specified and directed by Engr-in-Charge.
Stop valves cast copper alloy chromium plated with long shank (concealed), screwed both ends for iron pipe 15 mm bore complete all as specified and directed.
Excavation in post holes each not exceeding 0.50 cum getting out, returning filling in and well ramming earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance exceeding 1.5 kilo mtr and making good distrub surfaces as in hard/dense soil complete all as specified and directed.
Plain cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in post hole, foundation and similar work etc complete all as specified and directed.
Roof trusses (framed) trussed, purlins, crane gantries rails and fastenings and heavy brackets, post, eves board including frame work and similar work framing (beam, tee, channel or flat sections) including distance pieces cleats including welding reavrign etc. complete all as specified and directed.
Preparation of new surfaces of wall and applying three coats of white wash complete all as specified and directed.
MS flat iron as in wind ties etc confirming to Fe 410-0 or Fe 310-0 including clamps complete all as specified and directed.
Surface excavation over areas, not exceeding 1.5 m deep and geeting out in hard/dense soil and complete all as specified and directed.
Removing excavated soil material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the base in soil complete all as specified and directed.
PCC (1:4:8) type D-2 as in foundation, filling and mass concrete for in fixing MS bed plates fixed with MS Tubular post complete all as specified and directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm and deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed.
150 mm thick PCC type B-2, 1:2:4 (using 40 mm graded aggregates) as in paved area shall be laid in alternate bay, 10 mm thick joint shall be provided joint shall be filled with bitumen mastic, bitumen mastic shall comprises of 1 part of hoted bitumen 85/25 and 3 parts of sand all by weight finishing cement concrete surface even & fair without using extra cement complete all as specified and directed.
Supply Installation Testing and Commissioning of Solar Water Heater System (Flat Plate Collector) (FPC Type) Direct Thermosyphonic type Non Pressurized with 1000 Ltrs SS Tank with tank stand, 100 mm Rockwool Insulation and Al. Cladding with 10 collectors, collector Stand copper couples, end caps, Box type collector with Screwless Technology Including Transportation and Installation of Solar water Heater including 3KW heating element = 03 Nos complete all as specified and directed. Make : Recold Omega. (i) Solar Collector should be box type structure for high strength and stability. (ii) The collectors should have the Brass Couplings and end caps for Rustproof and long life screw. (iii) The collectors must have a screw less construction for water proof and high stability. (iv) Solar hot water tank of capacity 1000 Ltrs. Of SS316L type material
Note (a) The manufacturer will provide free maintenance and servicing of the Solar water heater system for 2 years and the cost of the same will be included in Quoted rates by the contractor and further AMC on agreed mutual terms and conditions. (b) General maintenance program and training will be conducted to the MES staff and user by the manufacturer and cost of the same will be included in the quoted rates. (c) The collectors warranty should be 7 years.
Lagging of pipes used in water supply or plumbing all round with 25 mm thick bonded mineral wool pre-formed SNAP ON pipe section of density 144 kg/cum confirming to IS 9842 on following pipe of internal dia 20 mm complete all as specified and directed.
Lagging of pipes used in water supply or plumbing all round with 25 mm thick bonded mineral wool pre-formed SNAP ON pipe section of density 144 kg/cum confirming to IS 9842 on following pipe of internal dia 15 mm complete all as specified and directed.
Sub main wiring with proper colour coding, insulated, multistranded, copper conductor PVC FRLS cable of 2 run 6 sqmm for phase and neutral and one run of FRLS 4.0 sqmm for earth wire unsheathed, multistranded, copper conductor, PVC cable complete all as specified and directed. Make : Plaza/ Polycab/KEI
Sheet metal enclosure MCB distribution board Single pole & neutral 240 volts 2 way with single door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces complete all as specified and directed. Make - Indo Asian/Legrand/ Schneider/Siemens.
MCB single pole and neutral 240 volts, 50 htz with breaking capacity 10 KA, IP 20 protection of rating 40 to 63 Amps complete all as specified and directed.
Cutting existing GI pipe of any size for taking new connection including all fittings, joints etc complete all as specified and directed.
PCC 1:2:4 type B-1 (20 mm graded aggregate) for cement concrete in foundations, filling and mass concrete complete all as specified and directed.
Taking down carefully aluminium/copper point wiring complete with (light, fan, socket or power) complete fitting such as switch, sockets, ceiling rose, pendents sockets any type, rectangular board terminal boxes etc and making good disturbed surface of walls and all as specified keeping a side serviceable item for re-use within the same bldg and removing unserviceable item from site complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable in and including not less than 2.00 mm thick 20 mm dia & over concealed PVC non metallic rigid PVC conduit (ISI marked) with 1.25 mm thick pressed steel terminal boxes (modular type) concealed for fixing of modular switches/regulator etc along with PVC insulated and insheathed FRLS 1.5 sqmm multi stranded copper conductor cable (green color) as earth lead in and inculding PVC Concealed Conduit medium grade with all fitting (ISI make), as directed by Engr-in-Charge & including modular cover plate with frame, making good the disturbed surfaces to match with the existing specification complete all as specified and directed. Make - HPL or equivalent make in polycab/Havells
All as per ser item No 175 but for 06 Amp socket outlets point controlled by one switch on Independent board complete all as specified and directed.
All as per ser item No 175 but for 06 Amp socket outlets point controlled by one switch on Same board complete all as specified and directed.
All as per ser item No 175 but for 16 Amp socket outlets point controlled by one switch on Independent board complete all as specified and directed.
Switch single pole one way 6 Amps 240 volt (Modular Type) with outer strip & front cover plate complete all as specified and directed.
Sockets, 3 pin 6 Amps, 240 Volt flush type (Modular Type) with outer strip & front cover plate complete all as specified and directed.
Sockets Combined 2-in1, 3 pin 16 Amps, 240 Volt flush type (Modular Type) with outer strip & front cover plate complete all as specified and directed.
Switch single pole one way 15/16 Amps 240 volt (Modular Type) with outer strip & front cover plate complete all as specified and directed.
Ceiling rose surface bakelite 3 terminals complete all as specified and directed.
Replacement fan regulator 120W, 230V 50 C/S, deluxe Modular type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically all as required or complete all as specified and directed by Engineer-in Charge.
Taking down carefully existing ceilling /exaust fan any type sweep and removing fan blade including cleaning all dust particle and filling cavities with filler material, oiling, greasing including painting fan with blade complete one coat of synthetic enamel white paint by spraying and assemble the same along with all fixing connecting accessories and fixing the same position along with all new electrical wire connection complete all as specified and directed.
Slim linear LED tube light fixture 20 Watt as per 4 Ft white, Garnet Batten, Housing made of extruded AL with lumen O/P should not be less than 100 lum/watt with wider beam angle should be greater than 120 deg and poly difuser CRI should be more than 70 & PF should be greater than 0.9 making all connection using 1.5 sqmm copper conductor multistranded PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete all as specified and directed. Make- HPL Cat Part No - HLPLEDCADPL20CW or Equivalent make in polycab/Havells (E-lite LED TRICA)
1x9 Watt LED 5700 k to 6000K Mirror light ultra slim square profile linear LED lightining fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack complete all as specified and directed. Make: Havells, Cat Part No LHEXARP7PN1W009 or equivalent make in Bajaj/Wipro/syska
Slim type 36/40 Watt 2 x 2 LED Flat Panel light with diffused optics (600 x 600 x 12 mm) complete making all connection using 1.5 sqmm copper conductor multistarnd PVC insulated 3 core flexible cable complete all as specified and directions of Engr-in-Charge. Make-HPL Cat Part No - LEDPN36-E (WW) or equivalent make in Havells)/Polycab
Bulk head light fitting, environmental friendly, ultra modern, energy saving, surface mounted, Oval plastic shaped, LED luminaire comprising of high brightness LEDs, IP54 complete all as specified and directed.
LED street Light fitting 35 Watt, New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with acrylic with Heat resistant toughened Glass, Corrosion resistant, CCT 5700K complete making all connection with MCB SPN 40amp alongwith MCB Box enclosure complete all as specified and directions of Engr-in-Charge. Make - Havells, Cat Part No - LHETBXU7PAIS035 (ENDURA CITYLITE PLATINUM PLUS)/polycab
Street light Bracket complete made of GI pipe of suitable size of 25 mm, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall complete all as specified and directed by Engr-in-Charge.
Submain wiring with two single core PVC insulated unsheathed, FRLS flexible copper conductor cable of size 10 sqmm and one single core PVC insulated unsheathed, FR flexible copper conductor cable of size 6.0 sqmm as earth lead in & inculding PVC casing/non metallic rigide PVC conuit medium grade and making good the distured at site or complete all as specified and directed by Engr-in-Charge. Make of cable- KEI/ polycab/finolex
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Note - MCBs will be measured separately.
Replacement of Sheet metal enclouser single pole and neutral with 2 pin and earth plug and socket 20A 240V complete with one single pole MCB of any cap from 10 Amp to 20 Amp, 10KA complete all as specified and directed.
Replacement MCB single pole 240 volt any rating from 10 to 32 Amps, B-Series, with rupturing capacity 10 KA, inculding providing aluminium thimble for out going cable. Make - Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard-8GB32)/Indo Asian(optipro)
Replacement MCB Single Pole & Neutral 240 volt any rating from 40 to 63 Amps, B-series, with rupturing capacity 10 KA, inculding providing aluminium thimble for out going cable complete all as specified and directed. Make - Legrand (DX3)/ Schneider (Acti-9)/Siemens (Betagard-8GB32 )/Indo Asian (opti pro)
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed.
XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor of sizes 16 Sqmm 4 core complete all as specified and directed.
Brick covering width equal to length of brick for mechanical protection to cable with well burnt sub class 'B' bricks laid dry flat complete all as specified and directed by Engr-in-Charge.
Sand cushioning for under ground cable provided with a layers of 8 mm high before laying cable and 15 mm thick after laying and stretching the cable complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exceed 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Galvanized steel pipe light grade with all fitting laid in trenches or passing through cable/road crossing or fixing along pole with suitable size clamps complete of size 40 mm dia complete all as specified and directed.
VTPN MCCB DB-Double Door (Including 63 Amp MCCB) 16 kA (as Incommer) 4 way double door IP-43 protection complete all as specified and directed. (Including All PCC & Cementing work for installation of TPN DB to Wall, deemed to be quoted rate by contractor)
Point wiring for one light/fan point controlled by one switch using 1.5 Sqmm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20 mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type in adequate module of switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and directed.
All as per ser item No 204 but for 3 pin 5 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and directed.
All as per ser item No 204 but for 3 Pin 15 Amps socket outlet independent with cable 2.5 Sqmm including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
Switch piano modular type, 1 module, 10 Amps, 230 volts one way complete all as specified and directed. Make - Anchor /Havells/Legrand
Switch piano modular type, 1 module, type 16/20 Amps 230 volts one way complete all as specified and directed. Make - Anchor/Havells/Legrand
Socket outlet modular type, 2 module, 5 pin, 10 Amps combined complete all as specified and directed. Make - Anchor /Havells/Legrand
Socket outlet, modular type, 2 module, 2-in-1, 20 Amps combined complete all as specified and directed.Make - Anchor/ Havells/Legrand
Ceilling rose, surface bakelite 65 x 50 mm two to three terminals fixed on PVC Round Block complete all as specified and directed.
New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 20 W, complete all as specified and directed by Engineer-in-Charge. Make - Havells, Cat Part No LHEXBXPNIN1W020 or equivalent to Polycab/HPL/Bajaj
Replacement of New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 10 W, complete all as specified and directed by Engineer-in-Charge. Make - Havells, Cat Part No LHEXBXPNIN1W010 or equivalent to Polycab/HPL/Bajaj
KALSOTRA CONSTRUCTION CO
RAMAN CONSTRUCTION CO
VARDHMAN INTERNATIONAL
s l sharma and sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .