Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹22.5 LAdmitted-Finance | -23.27% | ₹22.5 L | L1 | Admitted-Finance |
| 2 | L2₹22.8 LAdmitted-Finance | -22.10% | ₹22.8 L | L2 | Admitted-Finance |
| 3 | L3₹23.7 LAdmitted-Finance | -19.11% | ₹23.7 L | L3 | Admitted-Finance |
| 4 | L4₹25.3 LAdmitted-Finance | -13.56% | ₹25.3 L | L4 | Admitted-Finance |
Tender Value
₹29.3 L
EMD Value
₹58,520
Closing Date
29 Jul 2026, 6:00 pmClosed
EXECUTIVE ENGINEER-ELE.
UDA Office Udaipur
Shifting of Existing Overhead 11KV Line and Transformer due to Construction Service Road from Kali Magri to RTO Junction on 200ft. Road from Sukher to RTO. 3007
2026_UITUD_574717_1
NIT_30_07
Open Tender
Electrical Works
Percentage
90 days
Udaipur
Please Refer Tender Document
2 documents required · 2 mandatory
₹590
Refer Tender Document
₹58,520
Yes
17 Aug 2026
13 Jul 2026
30 Jul 2026
13 Jul 2026
29 Jul 2026
13 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Item Code [12.13-2025]:Item Type [Electrical] ::Sub Item Code [12.13-2025 + 12.13.6]: P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). 120 mm | 80 | Mtr | 290 | ₹23,200 |
| 2 | Item Code [13.1-2025]:Item Type [Electrical] ::Sub Item Code [13.1-2025 + 13.1.4]: Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC pipe / Hume Pipe/ Stoneware Pipe/ PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. 3 core 185.0 Sq.mm | 100 | Mtr | 1,756 | ₹1,75,600 |
| 3 | Item Code [13.7-2025]:Item Type [Electrical] ::Sub Item Code [13.7-2025 + 13.7.2/13.7.2.3]: Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. 11 KV End Termination Kit Outdoor type/3 core 120/150/185 Sq.mm | 2 | Each | 6,576 | ₹13,152 |
| 4 | Item Code [13.7-2025]:Item Type [Electrical] ::Sub Item Code [13.7-2025 + 13.7.3/13.7.3.3]: Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. 11 KV Straight Through Joint Kit /3 core 120/150/185 Sq.mm | 2 | Each | 10,219 | ₹20,438 |
| 5 | Item Code [19.1-2025]:Item Type [Electrical] ::Sub Item Code [19.1-2025 + 19.1.2]: Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. 9.0 Mtr long PCC pole of 200 Kg Working Load | 4 | Each | 5,277 | ₹21,108 |
| 6 | Item Code [19.1-2025]:Item Type [Electrical] ::Sub Item Code [19.1-2025 + 19.1.3]: Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. 9.0 Mtr long PCC pole of 400 Kg Working Load | 2 | Each | 6,483 | ₹12,966 |
| 7 | Item Code [19.13-2025]:Item Type [Electrical] :: Supply and fixing of 11 kV pin insulator confirming to IS:731:1971 with latest amendment on existing bracket including all accessories like MS forged hot dipped GI Pin confirming to IS 2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment, and as per latest Discom specs. etc. as required. | 84 | Each | 196 | ₹16,464 |
| 8 | Item Code [19.14-2025]:Item Type [Electrical] ::Sub Item Code [19.14-2025 + 19.14.1]: Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest amendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. B & S type hardware 45 KN | 24 | Each | 734 | ₹17,616 |
| 9 | Item Code [19.14-2025]:Item Type [Electrical] ::Sub Item Code [19.14-2025 + 19.14.3]: Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest amendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. B & S disc insulator 45 KN | 48 | Each | 404 | ₹19,392 |
| 10 | Item Code [19.16-2025]:Item Type [Electrical] :: Supplying and laying of Hot dip galvanized steel stay wire of 550-900 N/mm Quality confirming to IS-2141/2000 in all respect Including chemical composition (Heavily coated Hard quality) of dia 7/3.15 mm(7/10 SWG) and as per latest Discom specs. etc. as required. | 64 | Mtr | 110 | ₹7,040 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
Conditions_07.pdf
Tender Documents • 1.35 MB
BOQ_1022268.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].