Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹5.9 L+₹20,750 (3.66%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹6.8 L+₹1.1 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
26 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR/MAINTENANCE OF ELECTRIC GEYSERS AT NAGROTA UNDER GE NAGROTA.
2020_MES_381252_1
GEN-44/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA
Class E and above and category b (i)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹20,000
Yes
5 Nov 2020
26 Sept 2020
31 Oct 2020
26 Sept 2020
26 Oct 2020
10 Oct 2020
60 days
Amount
Taking down the water heater storage type of any make of any capacity. dismantling the water heater carefully from its position fixed on walls, reassembling the water heater after replacement of defective parts and reinstalling the water heaters to their original locations or as directed, commissioning and testing the water heater complete, all as directed by the Engr-in-charge. Note: Any material/part found unserviceable during servicing shall be replaced by the contractor and measured and paid separately under respective items.
S&F in replacement of unserviceable PVC connection of any make with (ISI Mark) having 10mm dia, 45 cm long steel reinforcement suitable for hot water geyser outlet supply with 02 Nos of Unions/ cup shaped PVC cover with washers all as directed by Engr-in-charge.
S&F in replacement of unserviceable PVC connection of any make with (ISI Mark) having 10mm dia, 45 cm long suitable for cold water geyser inlet with 02 Nos of Unions/ cup shaped PVC cover with washers all as directed by Engr-in-charge.
S&F in replacement of unserviceable inner tank of 25 litres capacity water heater storage type, tank made out of copper sheet of size 22SWG, MS collar with six/seven/eight/ nine holes for fitting the flange assembly with vent pipe of brass, 3 “ long, 15 mm dia, threaded, including MS sheet ring all as directed by Engr-in-Charge.
All as per srl item 4 above but of 50 litres capacity.
S&F in replacement of unserviceable inlet /outlet assembly of any make of geyser having six/seven/eight /nine hole suitable for Bathwell/ Bajaj / pearl water heater of capacity 25/50 litre all as directed by Engr-in Charge.
S&F in replacement of unserviceable inlet /outlet assembly of any make of geyser having six/seven/eight /nine hole suitable for Bathwell/ Bajaj / pearl water heater of capacity 10 litre all as directed by Engr-in Charge.
S&F in replacement of unserviceble rubber gasket suitable for six/seven/eight/ nine hole assembly of suitable size of water heater of capacity 50/25/10 ltr.
S&F in replacement of unserviceble 4'' long and 1/2'' dia Chrome plated bolt with suitable washers all as directed by Engr-in-Charge.
S&F in replacement of insulating material (glass wool) suitable for 25/50 litres capacity water heater, all as directed by Engr-in-Charge.
S&F in replacement of unserviceble split bottom cover (two pieces) suitable for water heater of any capacity duly painted, all as directed by Engr-in-Charge
S&F in replacement of unserviceble neon indicating lamp, rectangular /round as required at site, all as directed by Engr-in-Charge.
S&F in replacement of unserviceble heating element 1.5 KW, single phase, 230 volt with triangular base suitable for 25/50 Ltr water heater complete all as specified and directed.
S&F in replacement of unserviceble heating element 2.0 KW, single phase, 230 volt with triangular base suitable for 25/50 Ltr water heater complete all as specified and directed.
S&F in replacement of unserviceble heating element 1.5 KW, single phase, 230 volt with round base suitable for 25/50 Ltr water heater complete all as specified and directed.
S&F in replacement of unserviceble heating element 1.5 KW, single phase, 230 volt with round base suitable for 10 Ltr water heater complete all as specified and directed.
S&F in replacement of thermostat switch range upto 80”C suitable for 25/50 ltrs cap water heater complete all as specified and directed.
S&F in replacement of thermostat switch range upto 80”C suitable for 10 ltrs cap water heater complete all as specified and directed.
S&F in replacement of steel outer body 50 Ltrs capacity, any make complete all as specified and directed
S&F in replacement of steel outer body 25 Ltrs capacity, any make complete all as specified and directed
S&F in replacement unserviceable electric cable copper conductor, 3 core 2.5 Sqmm with PVC insulation complete all as specified and directed.
S&F in replacement of unserviceable plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement of unserviceable safety nut for geyser of capacity 25/50 ltrs complete all as specified and directed.
S & F in replacement of unserviceable sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20Amp complete all as specified and directed.
Painting to outer body of geyser of capacity 25 ltr with white synthetic enamel paint of approved make after preparation of surface including filling cavities with filler of all as directed by Engr-in-Charge.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 11255.00 during AOC Note:- Tenderers shall not quote for this Schedule
Nitika electricals and engineers works
J S ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .