| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹18.3 L Quoted ₹18.9 L | L1 | Accepted-AOC Being Lowest L1 |
| 2 | L2₹19.6 L+₹74,605 (3.95%)Rejected-Finance NEAR NATRAJ MANDIR NEW INDIA COLONY PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹19.6 L+₹74,605 (3.95%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹22.1 L+₹3.2 L (16.9%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | ₹22.1 L+₹3.2 L (16.9%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹22.5 L+₹3.6 L (19.3%)Rejected-Finance | ₹22.5 L+₹3.6 L (19.3%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹23.2 L+₹4.4 L (23.2%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | ₹23.2 L+₹4.4 L (23.2%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Jul 2021, 6:00 pmClosed
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR/ MAINT OF EXTERNAL ELECTRIFICATION, INTERNAL ELECTRIFICATION, COOLING PPLIANCES, WATER SUPPLY, PUMP AND DISTRIBUTION NETWORK AND MISC EM WORKS AT JANDWAL UNDER GE (AF) PATHANKOT
2021_MES_455000_1
8420/GE/PAF-22
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) PATHANKOT
As Per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹60,000
Yes
13 Oct 2021
26 Jun 2021
26 Jul 2021
26 Jun 2021
24 Jul 2021
10 Jul 2021
Amount
Carrying out comprehensive maintenance of Internal/External electrification work on day to day complaint basis as directed like replacement of internal wiring accessories, switches, switch socket, holders, light fittings, burnt wires, MCB's, DB's, lugs etc, repairing of geysers, cooling appliances, stabilizers, checking and joining of cables to OH conductors, repair to street/ perimeter lights and all other connected electrical work including collection of complaints from complaint cell on daily basis and resubmitting back to SBA after completion of job. (All defective parts shall be paid & measured separately as supply only) Note:i) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type. (ii) Penalty for not rectifying the defect in time(within 24 hrs) will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract. (iii) Manpower requirement for attending and completing day to day complaints will be depending upon the number of complaints which may vary day to day and cost of same is deemed to be included in quoted rate. Contractor is advised to quote accordingly. (iv) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M/Rep of MES. (v) Old material obtained from replaced items under this item shall be contractor's property and will be measured as per Schedule of credit. (vi) Cost of minor spares i.e, insulation tape, lugs, thimbles etc are deemed to be included in the quoted rate. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor.Items replaced shall be measured and paid seperately under Srl Item No. 2 (vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates.
Supply only following parts/items to 2.00 to 2.42 be fixed under item No. 1 above complete all as specified and directed: Switch Piano/Bell Push flush type 5/6 Amps 230 volts.
Switch Sockets combination outlet multipurpose 5/15 Amps, 240 volts complete all as specified
Socket Outlet 5 Amps, 5 Pin, 240 volts complete all as specified.
Batten/ Pendant Holder with B-22 base as per requirement complete all as specified
Geyser Element as per existing sample i.e tikona/round number of mounting holes etc.
Geyser Thermostat valve for any capacity
Geyser Inner tank suitable for 25 ltr capacity geyser
Geyser Syphon Assembly suitable for 25 Ltr capacity geyser
Electronic ballast suitable for FTL lamp 36/40W in ABS housing with lead in wires complete all as specified and directed.
Electromagnetic choke suitable for 9/11/13W Non retrofit CFL lamps, 230 volts
Non retrofit CFL lamp 9 W, 2/4 pin as required.
Retrofit LED Tube rod of minimum 18W with polycarbonate cover having lumen efficacy not less than 100 Lumen/Watt and suitable for replacement of T8 36 Watt tube rod
PVC insulated multistranded single core FRLS copper cable 1.5 sqmm
PVC insulated multistranded single core FRLS copper cable 2.5 sqmm.
PVC insulated multistranded single core FRLS copper cable 4.0 sqmm
PVC insulated multistranded single core FRLS copper cable 6.0 sqmm
PVC insulated multistranded aluminum conductor 1100 volts grade twin core 16 sqmm complete all as specified and directed by Engr-In-Charge.
MCB SP 5-32 Amps,240 volts, 9kA complete all as specifed and as required.
MCB SPN 32-63 Amps,240 volts, 9kA complete all as specifed and as required.
MCB TPN 32-63 Amps,415 volts, 9kA complete all as specifed and as required.
Call bell ding dong type 230 volts complete all as specified and as required.
Thermostat switch for Air conditioners/deep freezers/water coolers as per sample
Starting relay for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Overload relay for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Starting capacitor for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Running capacitor for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Blower motor for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Condensor motor for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Swing motor for Air conditioners as per sample
Blower/condensor fan blade for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Condensing Coil for Air conditioners/deep freezers/water coolers/refrigerators as per sample
Cooling Coil for Air conditioners/deep freezers/water coolers/refrigerators as per sample
PCB controller board for Air conditioners/refrigerators as per existing sample
Special annealed double wound copper tubing of dia 3/16'' to 5/8" size including brazing at end connections duly covered with suitable thermal resistant nitrile insulation complete all as specified and directed by Engr-In-Charge
Special annealed double wound copper tubing of dia 1/4'' to 1/2" size including brazing at end connections duly covered with suitable thermal resistant nitrile insulation complete all as specified and directed by Engr-In-Charge
Submersible tullu pump 230 volts for desert coolers as per existing sample
Blower motor 230 volts for Desert coolers as per existing sample
Wood wool pads for desert cooler as per existing sample
Push cock for water coolers chrome plated as per existing sample
Float valve for water coolers/desert coolers as per existing sample
Fan regulator step type as per existing sample complete all as specified.
Capacitor 2.5 to 3.15 microfarad suitable for ceiling fans
Capacitor 4.0 MFD suitable for ceiling fans
Supply and fixing of LED light fittings, 230 Volts,indoor type wall mounting type made up of polycarbonate with lamp holder, LED Lamp 7W, with B-22 base, connector block etc complete with all accessories, pre-wired complete all as speciifed and directed by Engr-In-Charge.
Supply and fixing of weather proof Bulk Head LED light fittings not less than 10 Watt, 230 Volts,made up of polycarbonate connector block, LED driver etc complete with all accessories, pre-wired complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of street light fitting LED type 72Watt with pressure die casted aluminium housing with flat glass optical cover with lens to ensure uniform distribution with minimum 100 lumen/watt efficacy, IP 66 protection including LED Driver and housing of same make as of fitting as per BIS standards including connecting terminals, mounting clamp and all other accessories reqd for fixing and making fitting operational complete as directed by Engr-In-Charge
Supply and fixing in replacement Tube light fitting box type, including LED tube rod of minimum 18W including connector blocks, bipin holders prewired including LED driver complete all as specified and directed.
Lowering of High Mast lights mounting arrangement using suitable T&P as required and refixing after repair to the height of minimum 16mtr including refixing chain assly with spigot etc all as required for smooth function of hoisting and lowering movement of High mast light complete all as specified and directed by Engr-In-Charge.
Dismantling, opening and cleaning of complete radiator assembly of DG Set upto 125 KVA of any make and checking of water leakage, cleaning of slots including welding/brazing where required and chekcing/cleaning of radiator fans including refixing in position complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of AVR unit for upto 125 KVA DG Set (automatic voltage regulator controller card) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of new battery 12 V, 180 AH complete all as specified and directed by Engineer-in-Charge.
Opening and Dismantling of self starter of upto 125 KVA and repairing with replacement of defective parts and refitting and testing complete (Note:- defective parts will measured and paid separately)
(a) Supply only following items 12.00 to 32.05 to be fixed under item No 11 above: Armature 01 No.
(b) Supply only Field coil copper 01 Set.
(c) Supply only Carbon Brush 01 Set.
(d) Supply only Bearing 02 Set.
(e) Supply only Pinion 01 Nos
(f) Supply only clutch assly
Supply and fixing stop solenoid switch complete including plunger and mounting arrangements for upto 125 KVA DG Set matching with existing sample complete all as specified and directed by Engineer-in-Charge.
Servicing of Solar water heating system complete including removing the sediment and descaling the complete circulation tubes with the helps of recommended chemical/acid and brazing/welding the drilling portion and broken or leaking part of tubes to make the tube leak proof and serviceable, replacement of gasket, nut bolts washers, hose pipes, flanges etc all as required for proper functioning complete all as specified and directed by Engr-In-Charge.
Dismantling of solar water heating system of any capacity by removing all parts and reassebling the same after replacement of unserviceable items, including replacement of minor items/plumbing work as required including gasket, nut bolts washer ,hose pipe , flanges, chipping of roof floor , grouting of base plate and , making pedestal of all the grouted legs and minor plumbing work complete all as specified and directed by Engineer -in-Charge .
Replacement of collector plate of size as per sample complete all as per site requirment and directed by Engineer -in-Charge .
Replacement of collector glass as per sample all as per site requirment and directed by Engineer -in-Charge .
Supply and fixing in replacement of solar panel cirunation copper tubing set copmlete (including welding strip/sheet of standard size and Flanged joints ) all as per site requirement and as directed by Engg-in -Charge.
S&F stainless steel water makeup tank of suitable cap connected with main stainless steel tank complete all as specified and directed.
Supply and fixing in replacement PVC insulated multistranded twin core aluminum cable 6 sqmm complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement LED street light surge protection device matching with existing sample complete all as specified and directed by Engr-In-Charge
Exc in trenches not exc. 1.5 m wide and not exc. 1.5 for laying of cables or other items and getting out in soft/loose soil complete all as specifed.
Supply and laying dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : only punned thickness shall be measured).
Material and labour for well burnt sub class 'B' bricks of nominal size 230X115X075 mm abutting each other for cable protection all as specified and directed by Engr in Charge.
Relaying of old serviceable bricks retrieved, in trenches as cable protection cover all as specified and directed by Engr-In-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified.
Removing excavated material not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified
Taking out old Underground cable of any type and size and keeping aside serviceable cable and bricks for relaying.
Labour only for Re-Laying fixing or passing through pipe only LT 1100 Volts grade Underground cable of any size incl connections from LT panel board all as specified and directed by Engr-in-Charge.
Supply Laying fixing or passing through pipe only U/G cable XLPE insulated armoured and PVC sheathed LT 1100 volts, grade with aluminum conductor of size 185 Sq mm 3.5 core incl connections at both ends using thimbles complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 30 above but for size 150 sqmm 3.5 core
All as per Srl item No 30 above but for size 95 sqmm 3.5 core
All as per Srl item No 30 above but for size 50 sqmm 3.5 core
All as per Srl item No 30 above but for size 35 sqmm 3.5 core
All as per Srl item No 30 above but for size 16 sqmm 2 core.
Material and labour for straight through joints suitable for armoured cable 1.1 KV rating heat shrinkable of following sizes complete all as specified and directed by Engr-in-Charge. (a) 240 sqmm to 185 sqmm 3.5 core
(b) 150 sqmm to 120 sqmm 3.5 core
(c) 95 sqmm to 50 sqmm 3.5 core
(d) 35 sqmm to 10 sqmm 3.5/4/2 core
Material and labour for end termination joints suitable for armoured cable 1.1 KV rating heat shrinkable of following sizes complete all as specified and directed by Engr-in-Charge. (a) 240 sqmm to 185 sqmm 3.5 core
(b) 150 sqmm to 120 sqmm 3.5 core
(c) 95 sqmm to 50 sqmm 3.5 core
(d) 35 sqmm to 10 sqmm 3.5/4/2 core
Preparaton of old surfaces for painting of existing LT/HT Poles by applying two coats of synthetic enamelled paint over one coat of primer red oxide complete all as specifed and directed by Engrs-in-Charge.
Preparaton of old surfaces for painting on existing LT/HT Poles alternate black and yellow straps of synthetic enamel paint 30 cm each up to 1.5 mtr from GL including writing Pole No. with Black paint over a round base of yellow paint complete all as specifed and directed by Engrs-in-Charge.
Fixing of broken LT Panel gates by providing proper hinge arragnement by welding/brazing or fixing with nut bolts, including making provision for locking including hinges of appropriate size complete all as specifed and directed by Engrs-in-Charge.
Supply and fixing in replacement junction box outdoor type of appropriate size made of steel sheet 1.6 mm thick painted with two coat of synthetic enamel paint over a coat of red oxide primer having aluminium bus bar 2 Nos of capacity 100 amps mounted on porcelain/PVC insulator suitable for connection of minimum 2 nos LT cables of size 25/35 sqmm 3.5 core including clamps, nuts and bolts etc, complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Bus bar chamber outdoor type made of steel sheet painted with two coat of synthetic enamel paint over a coat of red oxide primer having aluminium bus bar 4 Nos of capacity 200 amps mounted on porcelain /PVC insulator suitable for connection of minimum 4 nos cables of size upto 95 sqmm including clamps, nuts and bolts etc, complete all as specified and directed by Engr-In-Charge.
Tightning of OH line including dismantling of Existing ACSR conductor on poles (upto 6 conductors) and re-fixing of the same by tightning at various unit location by using suitable T&P as required for work complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement for ACSR conductor for OH line securing as poles complete with including binding wire jointing material stringing of capacity as per site requirement complete all as specified and directed by Engr-in-Charge
Cross arms bracing support clamps and back plates fabricated iron structural steel section incl nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat and one under coat and one finishing coat of alluminium paint complete all as specified and directed by Engr-In-Charge.
PVC line spacer for LT OH line on 9.0 mtrs pole suitable for 4/5/6 conductors complete all as specified and directed by Engr-in-charge
S&F in replacement Power pack suitable with input voltage 230 volts AC and output as required for control circuit including wiring with existing Circuit breaker complete all as specifed and directed by Engrs-in-Charge.
Disconnecting all the electrical connections from incoming and outgoing side, earthing, opening of top cover and hoisting of core and winding for checking/servicing/repair of three phase servo voltage stabilizer of capacity upto 200 KVA , 415 Volts oil cooled unbalance/ balanced type including replacement of unserviceable items, refitting complete stabilizer, connecting all connections including earthing including testing complete all as specifed and directed by Engrs-in-Charge. Note: (i)All the spares will be measured & paid separately as supply only under respective items of Sch'A',. (ii) Transportation to work shop for repair if required is deemed to be included in the quoted rates
Supply only following items No 50.00 to 50.06 to be fixed under item No 50 above: Servo control motor capacity 10 Kg with base plate, condenser, gear etc.
Auto controller card
Gear assembly matching with existing for fitting
Carbon bushes
Copper wire/strip winding for unbalanced type voltage stabilizer
Low/High Voltage Cut off Switch with controlling card
Voltmeter digital/analog type with range 0-500 volts
Earthing complete with copper Plate of size 600 x 600 x 3 mm thick electrode burried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to copper Strip of size 25 x 3mm . by means of nuts , bolts and washers of GI, protected by GI Pipe medium grade of 40 mm dia and with GI watering pipe medium grade 20 mm dia with funnel and wire mesh, including excavation and earth work in any type of soil including providing salt ,charcoal etc all around the plate including replacement of soil retrieved from exc with hygroscopic soil having good conductivity including.Earth Pit of PCC (1:2:4) type B-1 with earth pit CI cover with suitable handle complete all as shown in electrical plate No 3 of SSR-2009(Part-I) including testing on completion all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement copper strip of size 25x3mm secured on saddles, insulators as required complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Aluminum strip of size 25x3mm secured on saddles, insulators as required complete all as specified and directed by Engr-In-Charge.
Supply, heating and topping up/replacement Voltage transformer insulating oil HV grade having dielectric strength not less than 25 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified and directed by Engr-In-Charge.
Taking out burnt winding from the stator of the ceiling fan any make and sweep and M&L for rewinding with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing the windings complete all as specified and directed.
All as per item No 55 above but for exhaust fans complete all as specified and directed
Supply and fixing in replacement MCCB 3/4 pole 100 Amps, 16kA complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement MCCB 3/4 pole 160 Amps, 16kA complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement MCCB 3/4 pole 250 Amps, 25kA complete all as specified and directed by Engr-In-Charge
Taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including reassembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed.
Supply and charging of gas R407 to Package type AC Plants to maintain adequate gas pressure and seal the leakage of the unit if found leakage before charging the gas complete all as specified and directed by Engr-in-Charge.
Servicing of Package type AC plant unit of capacity 11 TR at site including, cleaning/descaling of cooling coil, insulation of suction and discharge line, oiling, greasing of blower motor, checking of electrical circuit supply and writing date of servicing with synthetic enamel paint of size not less than 50mm complete all as specified and directed by Engr-in-Charge
Cleaning of condensor coils of Package type AC plant of cap 11 TR with Acid/Scale removal compound for removal of scales deposited in condenser coils using suitable size iron rods/brush/water circulating pump etc. during the non functioning/shutdown period of the plant complete all as specified and directed by Engr-in-charge. Note: Acid/Scale removal compound and required T&P should be provided by contractor without any extra cost.
Supply and fixing in replacement strip heaters 3.0 kilowatt suitable for mounting in AC Plant ducts complete all as specified and directed.
Supply and charging of refrigerant gas R22 to Window/split type AC to maintain adequate gas pressure and seal the leakage of the unit if found leakage before charging the gas complete all as specified and directed by Engr-in-Charge.
All as per item No 65 above but for refrigerant gas R-134A, for water cooler/deep freezer/refrigerators complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement controller card suitable for package type AC Plant having two compressors each of 5.5 TR in one unit including internal control wiring complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement display cum operation unit for package type AC Plant of capacity 11 TR complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement single phase Kilowatt hour meter of range 5 to 30 Amps with mounting enclosure complete all as specified and directed by Engr-In-Charge.
Repair to broken gates of deep freezer/water cooler/Refrigerators by providing proper hinges at ends and to ensure complete compactness of the equipment to arrest cooling inside complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Metal clad Plug 2 pin and earth 20/32 Amps single phase as required complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Metal clad Socket for 2 pin and earth 20/32 Amps single phase as required complete all as specified and directed by Engr-In-Charge.
Supply and fixing in Replacement of electrical lead from main connection 3 core PVC insulated copper conductor of size 2.5 Sqmm complete all as specified and directed by Engr-In-Charge.
Removing the old unserviceable hermatically sealed compressor unit from Water cooler/refrigerator/Deep freezer of any capacity and fixing new sealed unit reciprocating type hermatically sealed compressor unit including charging of gas and oil to at adequate level complete all as specified and directed by Engr-in-Charge.
All as per item No 74 above but for 1.5/2.0 TR split/window type AC complete all as specified and directed by Engr-In-Charge
Taking up or down unserviceable GI/CI/DI/MS tubing of any grade any size bore including all cleaning for re fixing or removal to store complete all as specifed and directed by Engrs-in-Charge.
Laying only CI/DI pipe Spigot & Socketof any grade and any size in trenches (Obtained from Taking up/down) after cleaning complete all as specifed and directed by Engrs-in-Charge.
Laying only GI tubing of any grade and any bore with all new fitting in trenches (Obtained from Taking up/down) after cleaning complete all as specifed and directed by Engrs-in-Charge.
Supply and fixing 50 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specifed and directed by Engrs-in-Charge.
Supply and fixing 40 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specifed and directed by Engrs-in-Charge.
Supply and fixing 25 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specifed and directed by Engrs-in-Charge.
Supply and fixing 80 mm bore Mild steel tube medium grade galvanised with all fitting laid in trenches complete all as specifed and directed by Engrs-in-Charge.
Supply and replace of 50 mm bore gate valve Gun metal screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specifed and directed by Engrs-in-Charge.
Supply and replace of 40 mm bore gate valve Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specifed and directed by Engrs-in-Charge.
Supply and replace of 25 mm bore gate Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specifed and directed by Engrs-in-Charge.
Supply and replace of 20 mm bore gate Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specifed and directed by Engrs-in-Charge.
Supply and replace of 15 mm bore gate Gun metal alloy screwed down high pressure with crutch with or butter fly handle screwed booth ends for pipe complete all as specifed and directed by Engrs-in-Charge.
Supply and filling in Calcium based granular (65 to 70% chlorine content) disinfectant chlorination chemical with no sodium/iron/ murcury heavy metal containers for water treatment in chlorine dosing/contact tank, stability projected shelf life of chlorination of chemical must be one year with minimum loss of chlorine complete all as specified and directed by Engr-In-Charge.
Construction of valve pit of size 60 x 60 x 60 cm internal dimensions with 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded broken stone aggregate sub base of floor, 50 mm PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregae) in floor finished even and fair without using extra cement one brick work in CM 1:4 rending 15 mm thick plaster in CM 1:4 including 3 mm thick MS sheet pit frame 40x40x6 mm thick complete with locking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface and excavation in soft/loose soil, returning filling and removal of surplus soil up to 500 mtr distance complete all as specifed and directed by Engrs-in-Charge.
GI/CI fittings fittings any type radius and angle, taper any type, Straight, bend increasing ,decreasing or double socket etc Tee peces, single branch 'Y' junction double branch, coller, Kg capacity and plugs for any mm bore pipe line complete and all as specified and directed by Engr-In-Charge
Supply and fixing in replacement of 150 mm bore sluice valve type PN-1 double Flanged cost iron type with brass spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete and all as specified and directed by Engr-In-Charge
All as per Srl item No 91 above but of Size 100 mm bore complete all as specifed and directed by Engrs-in-Charge.
All as per Srl item No 91 above but of Size 80 mm bore complete all as specifed and directed by Engrs-in-Charge.
Material and labour for run lead joint to 150 mm bore complete and all as specified and directed by Engr-in - Charge
Material and labour for run lead joint to 100 mm bore complete and all as specified and directed by Engr-in - Charge
Material and labour for run lead joint to 80 mm bore complete and all as specified and directed by Engr-in - Charge
Replacement of 150 mm bore Non returen valve double Flanged cost iron type and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete and all as specified and directed by Engr-In-Charge
S&F ASD starter oil immersed of capacity 40 HP built in over load relay, incl taking down the existing unserviceable starter incuding oil complete all as specified by Engr-in-charge.
Supply and fixing in replacement LED Flood light luminaire with pressure die cast aluminum housing with glass cover and flood optics with LEDs of rating minimum 150W including LED Driver with IP-65 Protection including mounting arrangements complete as specified and directed by Engr-in-Charge.
Scrapping removing and cleaning of interior surface of overhead reservior of capacity 100000 gallon maximum at maximum 15 Mtr hight from ground level cleaning with alum water and brush to entire satisfaction of Engr in Charge including writing date of cleraning and capacity of tank with synthetic enamel paint of size 10 cm hight of tank complete all as specifed and directed by Engrs-in-Charge.
Supply and fixing Electromagnetic type choke suitable for 250W HPSV/MH HID Lamps complete all as specified and directed.
Supply and fixing Electromagentic type choke suitable for 150W HPSV/MH HID lamps complete all as specified and directed.
Supply and fixing Electromagentic type choke suitable for 70W HPSV/MH HID lamps complete all as specified and directed.
Supply and fixing Electromagentic type choke suitable for 400W HPSV/MH HID lamps complete all as specified and directed.
LED driver suitable for LED Streel light fittings matching with existing with 230 volts as input voltage complete al as specified.
LED lamp suitable for 18Watt LED Solar light fitting complete all as specified.
Supply and fixing HPSV/MH lamp as required, tubular type with E-40 base 250 W complete all as specified and directed.
Supply and fixing HPSV/MH lamp as required, tubular type with E-40 base 150W complete all as specified and directed.
Supply and fixing HPSV/MH lamp as required, tubular type with E-40 base 400W complete all as specified and directed.
Supply and fixing HPSV/MH lamp as required, tubular type with E-27 base 70W complete all as specified and directed.
Supply and fixing Ignitor three wire type suitable for HID Lamps upto 400 watt complete all as specified and directed.
Supply and fixing Lamp holder with E-40 Base screw type complete all as specified and directed by Engr-In-Charge.
Supply and fixing Lamp holder with E-27 Base screw type complete all as specified and directed by Engr-In-Charge.
Periodical maintenance of DG Set of capacity upto 125 KVA by replacing all filters, air cleaners, water seperators, engine oil, cleaning of diesel tank, cleaning of radiator assembly with air pressure including complete servicing of DG Set complte all as specified and directed by Engr-In-Charge.(Note: Items replaced will be measured and paid seperately under respective item of schedule)
Supply only following items 115.00 to 115.04 to be fixed under item No 114 above: Fuel filter suitable for DG Set of capacity upto 125 KVA
Air cleaner element suitable for DG Set of capacity upto 125 KVA
Lub oil filter suitable for DG Set of capacity upto 125 KVA
Lub oil 20w40 for DG Set of capacity upto 125 KVA
Coolant for topup/replacement
Fixing/laying only the following itmes complete all as specified and directed by Engineer In Charge. (Item shall be issued under Sch ,B,) (a) Voltage relay/Alternator voltage relay
(b) Ammeter
(c) Lighting Arrestor
(d) Cable gland any size.
(e) Spare contact kit for contractor
(f) CT any size
(g) Volt meter
(h) Self starter for DG Set
(j) Shut down valve
(k) Contractor / MCCB any size any capacity
(l) HT Cable jointing Kit
(m) LED Tube rod / fitting of any wattage
D R CONTRACTORS
M/S SHRI RAM BUILDERS
RK CONSTRUCTION ENGINEERS
Vijay Kumar Contractor and Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .