Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹36.6 L Quoted ₹39.5 L | L1 | Accepted-AOC 1ST LOWEST |
| 2 | L2₹41.0 L+₹1.6 L (3.94%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹41.0 L+₹1.6 L (3.94%) | L2 | Rejected-Finance 2ND LOWEST |
| 3 | L3₹44.3 L+₹4.8 L (12.1%)Rejected-Finance | ₹44.3 L+₹4.8 L (12.1%) | L3 | Rejected-Finance 3RD LOWEST |
| 4 | L4₹45.3 L+₹5.8 L (14.6%)Rejected-Finance | ₹45.3 L+₹5.8 L (14.6%) | L4 | Rejected-Finance 4TH LOWEST |
| 5 | L5₹46.1 L+₹6.6 L (16.7%)Rejected-Finance | ₹46.1 L+₹6.6 L (16.7%) | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
11 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR MAINT OF CEILING FAN EXHAUST FAN GEYSERS CONNECTED ACCESSORIES AT MD AND OTM ACCNS AT GMS UNDER GE I GOS
2021_MES_444113_1
8000/09/21-22/0908/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹72,000
Yes
6 Aug 2021
19 May 2021
14 Jun 2021
19 May 2021
11 Jun 2021
4 Jun 2021
Amount
S & F in replacement of deshaped fan blades with Fan blade of ceiling fan any make, 1200mm sweep, including nuts, bolts and fixing complete all as specified and directed. Make: Ganesh or equvalant of USHA/Havells
S & F in replacement of rusted out louvers with MS finned louvers complete all as specified and directed. of the following sizes of exhaust fans Note : (Rates quoted to be included of necessary sky folding/ladders to work upto the ht of 15mtrs) (a) 300 to 380 mm sweep
All as per Item No. 02 above but 400 to 600 mm sweep
Taking down of geyser of any capacity any make and type for repairs overhauling after disconnecting of water and electric connection for denting & painting and fixing the same at site duly anchor fastned by grouting the wall and testing complete all as specified & directed. (Note:- Thermostat Heating elements base plate, Safety valve, Indicator lamps etc, to be measured and paid separately under the individual relevant items)
S & F in replacement of geyser element 1.5/2.0 kw capacity existing make at site complete all as specified and directed .
S & F in repalcement of thermostat suitable for geyser 25/50Ltrs Capacity as per existing make at site complete all as specifed and directed.
S & F in repair to copper cable flexible 3 core of size 1.5sq mm complete all as specified and directed. Make: - RR Kabel/ Finolex/ Anchor or Equivalent.
S & F in replacement of resin bounded extra thick glass wool complete all as specified and directed.
S & F in replacement of gasket for apparatus plate capacity 25/50 ltrs complete all as specified and directed.
S & F in repair to indicator lamp (Red / Green) as per existing at site complete all as specified and directed.
S &F in repair to Prismatic cold water inlet pipe 15mm dia 450mm long with brass union and rubber washers complete all as specified & directed.
S & F in repair to hot water outlet pipe 14 mm dia PVC wire coated with CP brass nut, bolts and rubber washers complete all as specified & directed.
M & L for brazing of copper tank inner vessel at leakage point and making good to the tank surface complete all as specified & directed.
S&F single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 30 Amp complete all as specified and directed. Make: L&T/standard/CG/ C&S / Havells or Equivalent
Removing the exhaust fans above 300 mm to 450 mm sweep from location and servicing including 2 coats of paint over a coat of primer after preparing the outer surface, writing MES No and fixing with flexible cord complete all as specified and directed.
Removing the Ceiling fan above 1200 mm sweep from location and servicing including 2 coats of paint over a coat of primer after preparing the outer surface, writing MES No and fixing with flexible cord complete all as specified and directed.
M & L for complete removal of existing treatment and applying one coat of synthetic enamel paint to geyser of 25 ltrs capacity complete all as specified and directed. (Note: - Taking down & refixing shall be measured & paid separetely under relavent items .)
M & L for complete removal of existing treatment and applying one coat of synthetic enamel paint to geyser of 50 ltrs capacity complete all as specified and directed. (Note: - Taking down & refixing shall be measured & paid separetely under relavent items .)
Removing the ceiling fan from position(at any ht) and making provision to fix in the existing ceiling / truss and providing MS hooks made out of 6 mm MS rod bend to shape and connecting up complete and 23/0.0076 flexible 2 core copper wire from connector to fan complete all as specified and directed.
M & L for ceiling fan down rod made out of 15 mm GI tubing medium grade including making necessary threads / holes etc suitable for hanging ceiling fan up to 3 m long after removing the u/s down rods complete all as specified and directed.
Disconnecting Electrically and dismantling of AC ceiling fans of any size of any make, washing thoroughly of bearing/bush by petrol, washing/cleaning fan blades, body etc. thoroughly, provision new greasing, replacement of wornout/defective/ unserviceable parts (wherever necessary), reassembling the same including provision of twin core flexible (copper) wire upto 1.0M long, reconnection, taking down and re-hanging the same after provision new safety pins and lock nuts at the same building and satisfactory test run on load complete all as specified and directed. (Note : Replacement of worn out/defective/unserviceable parts by providing new parts and rewinding shall be measured and paid separeately under relavent items).
All as per Item No. 21 above but exhaust fans of any size and make.
Rewinding the rotor of AC ceiling fans of any make1200 mm sweep with super enamelled copper wire of adequate size (i.e. gauge/dia) including all insulation materials, varnishing and baking heating providing connector etc. complete all as specified and directed.
All as per Item No. 23 above but for ceiling fan 1400 mm sweep
All as per Item No.23 above but for Exhaust fan upto 380 mm sweep complete all as specified and directed.
All as per Item No.25 above but for Exhaust fan upto 480 mm sweep complete all as specified and directed.
Remove the unserviceable ceiling fan 1200 mm sweep from position transporting to a reputed workshop, open the covers remove the burntout unserviceable winding wire and rewind with insulated copper winding wire after preparing the slots etc including proper insulation and remove the unserviceable bearing and brass bushes and Supply and fix new suitable bearing and bushes including setting for smooth operation complete all as specified and directed.
All as per Item No.27 above but for exhaust fans
S & F Ball bearing of suitable size for ceiling fans including fixing complete all as specified and directed. (Make : SFK/TATA/NEC or Equivalent)
Remove the unserviceable capacitor and supply and fix new condenser 2/3.15/4 mfd for fans complete all as specified and directed. (Make : Havells/Universal/SFK or Equivalent)
Remove the unserviceable capacitor and supply and fix new condenser 6/8 mfd for fans complete all as specified and directed. (Make : Havells/Universal/SFK or Equivalent)
S & F Bush made out of copper of size suitable for any type/make ceiling fans including fixing complete all as specified and directed.
S & F steped type electronics fan regulator flush type only existing complete all as specified and directed. (Make : Anchor/SSR/Crompton or Equivalent)
S & F of ceiling fan clamps nut & bolt and rubber bush of suitable size complete specified & directed.
S & F PVC conduit pipe 20mm dia (ISI Marked) complete alongwith necessary fixing arrngment complete all as specified & directed.
S & F PVC casing capping 25 mm complete (ISI Marked) alongwith necessary fixing arrangment complete all as specified & directed.
S & F PVC flexible pipe 25 mm dia complete all as specified & directed.
S & F in replacement of 3 pin 15 Amps plug top complete all as specified & directed. Make: Anchor/ SSK/Indo-Asian or Equivalent
S&F in replacment of 200 mm sweep PVC Body , exhaust fan of 300mm sweep 40 watts cap with fixed fram louvers complete all as specified & directed. (Make : Smart-Air of Anchor/Fresh air DX 200 of Standard or equivalent in Crompton)
All as per Item No. 39 above but of 250 mm sweep complete all as specifed and directed.
S & F of 25 ltrs capacity Geyser of Metal/PVC body including nut bolt grouting with its clamp set & PVC connection pipe complete all as specified & directed. Make : cat part No: Senzo GHWASESWH025 colour white-Grey of Havells/Crompton or Equivalent
S & F of plastic canopy white colour suitable for ceiling fan 48"/56" sweep complete all as specified & directed.
S & F in replacment of ceiling fan 1200 mm sweep with blade and down rod complete fittings 5 star rated 70 watts cap complete all as specified and directed. Make : crompton greaves /usha/ Standard or equivalent
S & F in replacment of 250 mm sweep , exhaust fan with fixed fram louvers complete all as specified and directed. Make : CG/Anchor/Standard or equivalent
S & F in replacment of 300 mm sweep , exhaust fan with fixed fram louvers complete all as specified and directed. Make : CG/Anchor/Standard or equivalent
the bhimani group of companies
M/S. KISHAN ENGINEERING
M/s Ats Electricals
MM ENGINEERING SYSTEMS
M/s MAA BHAIRABI ENTERPRISES
NANGIA AND CO
HARAGOURI SUPPLIERS
S K ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .