Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹47.8 L+₹2.6 L (5.86%)Rejected-Finance 403 NARSINGH NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | JABALPUR | MP | 482005 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹47.8 L+₹2.7 L (5.96%)Rejected-Finance 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹48.0 L+₹2.9 L (6.32%)Rejected-Finance 292 GROUND FLOOR D BLOCK SAI DHAM RAJ CITY LONI BANTHLA GHAZIABAD GHAZIABAD UTTAR PRADESH 201102 | GHAZIABAD | UTTAR PRADESH | 201102 | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹48.9 L+₹3.8 L (8.34%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
31 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2021_MES_458083_1
8331/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (East) Jabalpur
D a(i)
6 documents required · 6 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹99,000
Yes
17 Aug 2021
8 Jul 2021
3 Aug 2021
8 Jul 2021
31 Jul 2021
24 Jul 2021
8 Jul 2021 - 20 Jul 2021
60 days
Amount
Dismantling of wall and ceiling boards( fibre pulp insulation etc) any thickness including cover fillets all as specified and directed.
M&L for PVC prelam printed 250mm x 6 mm multi wall false ceiling including moulded corner having size of 35 mm along perimeter of ceiling, screws fixed to brick wall/ partition, with help of nylon sleeves and screws at 610 mm centre to centre. Suspending the MS tubes section of size (19mm x 19mm x 0.32mm) with the help of level adjuster made of GI wire 4 mm dia with butterfly clips. 1220mm centre to centre with "Tube" section with the help of connecting angle and in direction perpendicular to the main section at 750 mm centre to centre fixed to PVC ceiling section with screws. Fixing shall be done mechanically either with screws driver or drilling machine with suitable attachments. Finally the PVC ceiling section jointed and finished so as to have a flush look which includes U clip and I patti ( as per recommended manufacturers specification) make : Sintex/doorplast, complete all as specified and directed by Engr-in-Charge
Excavation in trenches n.exc . 1.5m wide and n.exc 1.5m in depth for foundation etc and getting out in hard /dense soil upto distance of 50m out side the area under clearance complete all as specified and directed.
Demolition of RCC in any description and any position (reinforcement cut as required to facilitate demolition ) complete all as specified directed
Returning filling in including , spreading ,levelling watering and well ramming in layers n. exc 25 cm thick soft/ disintegrated rock.
Removal of surplus excavated Soil to a distance n. exc100 mtr from the starting point and at level of 1.5 mtr complete all as specified directed
M & L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling mass concrete.complete all as specified directed
M&L RCC M- 25 (Design Mix) (20mm graded aggregates) as in foundation and rafts, footing, foundation beam, plinth beam and base for column in mass concrete all as specified and directed.
M&L RCC M- 25 (Design Mix) (20mm graded aggregates) as in columns, pillars, posts, struts all as specified and directed.
M&L RCC M- 25 (Design Mix) (20mm graded aggregates) as in beams all as specified and directed.
M&L Brick work with sub class 'B' old size bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M & L rendering 15 mm thick or fair faces of brick/concrete surfaces in CM 1:4 finished surfaces even and fair all as specified and directed.
M & L rendering 5 mm thick or fair faces of brick/concrete surfaces in CM 1:4 finished surfaces even and fair all as specified and directed.
M&L PCC (1:2:4) type B-1 (20mm graded stone aggtt) as in coping including form work all as specified and directed.
S & F tor steel or TMT bar 10 mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including M.S wire ( annealed) not less than 0.9 mm dia all as specified and directed.
S & F TMT mild steel reinforcement as in stirrups 6 mm to 8 mm cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including M.S wire ( annealed) not less than 0.9 mm dia as in stirrups,spacer and binder
M&L for form work to sides of concrete foundations, footings, bases of columns raft and raft beams, sides and soffits if any of foundations and plinth beams and similar work, etc,rough finished surfaces of concrete etc all as specified and directed
M&L for form work to sides of pillars , posts struts, piers colums and stanchions,square, rectangular or polygonalrough finished surfaces of concrete etc all as specified and directed
M&L for form work to sides and soffits of floor or roof beam hunchings,girders bresummers, lintels,cantilevers,shelves,including supports overhangs etc also splays between floors and beams etc,rough finished surfaces of concrete etc all as specified and directed
M&L two coats of cement based paint including preparation of new plastered surfaces on wall
M & L in repair for 75mm bore UPVC Pipes (SCH-40) laid in weep holes complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description.
Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed by Engineer in-Charge.
Dismantling of brick work built in cement mortar including all quoins, arches etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc 15cm thickness (below or above ground level) and removing rubbish to a distance n. exc 100 m at low laying area complete all as specified and directed.
M&L machine cut kota stone slab flooring 20-25 mm thick over and including cement screed bed or bedding layer of cement mortar 15 mm thick in CM 1:6 for laying floor finishes laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all specified and directed.
All as per item No 26 but in skirting and daddo including rendering 10 mm thick Cement mortar (1:4)
M & L 75 mm thick PCC 1:4:8 Type D2 ( 40 mm graded aggregate) as in sub base to floors
M & L 75 mm Thick PCC 1:2:4 Type B-2 (using 40 mm graded aggregate ).without using extra cement finishing cement concrete surface even and smooth as specified and directed.
M&L for 75 mm thick PCC1:3:6 type C 2, using 40 mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement as specified.
S&F in repairs automation urinal sensor with complete Kit including all fitting and function for senso sensor urinal complete all as specified and directed by Engineer in Charge. Make : CERA (Make of existing senso sensor urinal is CERA)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish to a distance nexc 100 mtr at low lying area complete all as specified and directed
M&L non skid ceramic coloured tiles 7 to 8 mm thick joint free (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors laid over & including 15 mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to matchwith the shade of tiles all as specified and directed.
All as per Item above but skirting dado including rendering 10 mm thick Cement mortar (1:4)
M & L 25 mm Thick PCC 1:2:4 Type B-1 (using 20 mm graded aggregate ).without using extra cement finishing cement concrete surface even and rough and as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thick ness, M-35 Grade with Grey cement and using coloured pigment laid over and including 50 mm thick sand cushioning complete all as specified
M&L 75mm thick PCC (1:3:6) type C-2 (40mm graded stone aggregate) as in sub base under paver block complete all as specified and directed
M & L Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and as specified and directed by Engineer in-Charge.
M & L preparation of old decorated surfaces of walls including complete removal of existing treatment and applying two coats of distemper oil-emulsion over a coat of 2 mm thick average wall putty complete as specified and directed.
M&L for Preparing old decorated surfaces of wall and applying 2 coats of acrylic Emulsion paint over and incl 2 mm thick averaging wall care putty complete all as specified and directed.
M&L for frame work as in doors or gates of angle or other section with gusset plates, rails braces etc complete drilled for fixing of steel sheeting or other coverings, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete as specified and directed by Engineer in-Charge
Dismantling of mangalore pattern tiles of any type complete all as specified and directed
M&L for Roof tiles, Mangalore pattern,interlocking at side joints, laid dry including 15 mm thick screed bed in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles all as specified and directed.
M & L Precast RCC 1 : 2 : 4 Type B1 ( 20 MM graded stone aggregate) as in cover slab (for manholes etc), chajjas, mangers, shelves etc. set in cm 1 : 4 complete with joints to match complete including demolition of old RCC cover slab and removing the rubbish to a distance nexc 100m.complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5.Sqm & not exc 4 Sqm each
S & F aluminium door/window made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame and necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, Star lock, hooks & eyes peg stays, rubber beading and handles including connected items with and including, complete all as specified and directed. NOTE :(i) Minimum thickness of powder coating shall be 50 microns. Make:- Jindal, Hindalco, Nalco.
M&L for preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over and include a coat of red oxide primer complete all as specified and directed.
M&L for moorum/ red bajri, spread, rolled and consolidated to gradient and camber as required complete all specified and directed.
Taking down existing treatment including loose surface scraping with scraper chiseling scarping of surface with wire brush or any other method and removing the scrapped materials debris to a distance n.exc 50m depositing where directed complete all as specified.
M & L for 15mm thick rendering in CM 1:4 finished even and smooth as in roof mixed with water proofing compound as per manufacturer instruction by wt of cement brick or concrete all as specified and directed.
M&L for preparation of surface including cleaning, drying and removing all oil, grease, dust etc and priming the surface with a coat of Dr. Fixit primeseal apply at the rate of 8-10 Sqm/Ltr and applying two coats of Dr. Fixit Hydroshield PUD plus by brush or roller to achieve a total depth of 0.8 - 1mm with coverage of approximately 0.60Litre/Sqm per coat. Note : (i) The contents of Dr. Fixit Hydroshield PUD plus shall be thoroughly stirred for at least 2 - 3 minutes using a slow speed (300-400 RPM) drill machine attached with a mixing paddle. Do not dilute with water. Keep on stirring during application. (ii) All joints corners/drainage outlets and penetration points shall be treated prior to all application of Dr. Fixit Hydroshield PUD plus. All corners, gaps, joints, protrusions and outlets should be coated with an extra coat incorporating reinforcing fabric. (iii) Allow complete drying between coats with a minimum 3 to 4 hours depending on the weather conditions.
Supply only integral water proofing compound complete all as directed. Make- Pedilite/Impermo
M&L for preparation of new surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint in zebra pattern complete all specified and directed
Taking down cement plaster on brick or stone wall etc. including raking out joint, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L 15mm thick rendering on fair faces of brick work or concrete surface in cm 1:4 mixed with WPC as per manufacturer’s instructions, @ 3% by weight of cement finished even and fair without using extra cement complete all as specified and directed. NOTE: WPC shall be measured and paid separately
M&L for preparation of old decorated or unplastered surfaces and complete removal of existing treatment from walls aplying priming coat based coat providing Heritage finish (texture finish with metallic coloured in any design) in any shade to colours as aproved by Engr-in-Charge and as per manufacturer's instructions complete all as specified.
Schedule of credit amount of Rs. 99,980.00 to be deducted during AOC
LAL SINGH & SONS
M/S CHETAN PRAKASH GOYAL
Goodluck Enterprises
RAVINDRA ELECTRICAL
GHANI CONSTRUCTION
MAHAVIR TRADERS
M/S BHARTI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .