Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹8,600
Closing Date
12 Oct 2026, 2:30 pm3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Chief Engineer NCTPP3
Athi pattu, Chennai -120.
Carrying out Annual overhaul works related to BOP-I areas (Subdivision III) in C and I division
2026_EB_708832_1
CE/ES/CI/01/2026-2027
Open Tender
Maintenance Works
Works
NCTPS-III
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8,600
Yes
28 Sept 2026
28 Sept 2026
13 Oct 2026
28 Sept 2026
12 Oct 2026
28 Sept 2026
28 Sept 2026 - 10 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for removal of instrument air lines, volume booster, air lock relays, sov, etc of ON/OFF valves and checking/servicing the healthiness of above, checking tightness of power and signal supply lines, restoration of the same for smooth operation of pneumatic control valves in BOP-I areas. | 26 | NOS | - | - |
| 2 | Charges for removal of instrument air lines, volume booster, air lock relays, smart positioner etc of control valves and checking/servicing the healthiness of above, calibrating the smart positioner, refixing, checking tightness of power and signal supply lines, restoration of the same for smooth operation of pneumatic control valves in BOP-I areas. | 20 | NOS | - | - |
| 3 | Charges for checking, dismantling, refixing the temperature elements of ID/FD/PA FANs, APH, & other areas in BOP-I, also checking terminal tightness in transmitters/JB, Control cable loop checking, restoration of healthier value and Dressing of temperature elements cables. | 150 | NOS | - | - |
| 4 | Charges for dismantling vibrations of ID/FD/PA Fans calibration of vibration sensor, refixing, sensor alignment, terminal tightness in JB, Control cable loop checking, restoration of healthier value and Dressing of vibration cables. | 36 | NOS | - | - |
| 5 | Charges for dismantling of pressure/DPT, Level, Flow and temperature transmitters,gauges, switches & its impulse lines of BOP-I areas, transmitter healthiness checking, cable loop checking, refixing of transmitter and restoration of healthier value of pressure/DPT, Level, Flow and temperature transmitters, gauges, switches. | 150 | NOS | - | - |
| 6 | Charges for cutting, choke clearing, welding, servicing of damaged root valves, impulse lines, manifolds of Pressure/DPT/Flow transmitters in MS,HRH,SH/RH,Min ECO Flow & other BOP-I areas. | 80 | NOS | - | - |
| 7 | Charges for complete dismantling, calibration of Hopper Level switch & its RF type transmitters, refixing, tightness checking, dressing and restoration of the same for smooth operation of Hopper level switches in Eco and APH duct hoppers. | 32 | NOS | - | - |
| 8 | Charges for removing, servicing of HWL 1, HWL 2 and MEFCV SOVs, its feedback transmitter, controller, refixing, tightness checking of supply & signal lines, dressing of cables, restoration of smooth operation of the valves. | 3 | NOS | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
01SPEC.pdf
Tender Documents • 1.26 MB
BOQ_851824.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .