Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 CrAdmitted-Finance 3 4 520 TO 526 FLAT NO 303 PRAGATHI PRIDE APARTMENT BARKATHPURA HYDERABAD 500027 | HYDERABAD | TELANGANA | 500027 | ₹11.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹11.5 CrAdmitted-Finance | ₹11.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹11.8 CrAdmitted-Finance H NO 13 186 1 B D L COLONY BADANG PET BALAPUR MDL HYDERABAD 500112 | HYDERABAD | TELANGANA | 500112 | ₹11.8 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SAI CONSTRUCTIONS L1 | QUICK BUILDERS L2 | TRINETRA CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|
| 1.00SUBHEAD-I :EARTH WORK & EXCAVATION | ||||||
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | ||||||
| 1.00 | All kinds of soil | 63 | Cum | - | - | - |
| 1.00 | Ordinary rock | 11 | Cum | - | - | - |
| 1.00 | Hard rock (Blasting prohibited) | 3 | Cum | - | - | - |
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. | ||||||
| 1.01 | All kinds of soil. | 588 | Cum | - | - | - |
| 1.01 | Ordinary rock | 37 | Cum | - | - | - |
| 1.01 | Hard rock (blasting prohibited) | 9 | Cum | - | - | - |
| 1.01Extra for every Additional Lift of 1.5 m or part there of in excavation / banking excavated or stacked materials. | ||||||
Tender Value
₹12 Cr
EMD Value
₹22 L
Closing Date
24 Feb 2020, 2:00 pmClosed
V Ravisundara Kumar
CCE RnD Estates Chandraynagutta Hyderabad - 05
PROVISION OF CIVIL WORKS AND ALLIED SERVICES TO HOUSE 2MEV AND 3MEV LINAC MACHINES AT DAINDE, DRDL, HYDERABAD
2020_DRDO_534325_1
CCEESTENQCIVHYD/DRDL/118/19-20
Limited
Civil Works
548 days
Kanchanbagh
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Yes
CCE RnD Estates
₹22 L
Yes
3 Mar 2020
8 Jan 2020
25 Feb 2020
8 Jan 2020
24 Feb 2020
8 Jan 2020
Amount
SUBHEAD-I :EARTH WORK & EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Ordinary rock
Hard rock (Blasting prohibited)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil.
Ordinary rock
Hard rock (blasting prohibited)
Extra for every Additional Lift of 1.5 m or part there of in excavation / banking excavated or stacked materials.
All kinds of soil
Ordinary or hard rock
Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter
Supplying & Stacking Good Earth brought from outside MoD land
Credit for Hard rock Obtained from above items
SUBHEAD-II :ANTI TERMITE TREATMENT
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
SUBHEAD - III : PLAIN AND REINFORCED CEMENT CONCRETE WORK
Providing and laying in position Cement Concrete of specified grade including the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
Making Plinth Protection 50mm thick of Cement Concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and laying in position machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)
a)All works upto plinth level.
b)All works above plinth level upto floor V level.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum of concrete)
All works upto plinth level.
All works above plinth level upto floor V level.
Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Supplying fabricating and fixing in position Reinforcement Steel for RCC work at all levels and locations including the cost of steel, straightening, cutting , bending , binding and placing in position etc.,as per drawings and specifications including the cost of binding wire labour etc., complete for reinforced concrete.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and Shuttering including strutting, propping etc and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform.
Weather shade, Chajjas, corbels etc., including edges.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.using wall form shuttering at all heights using Paschal/Doka /approved equivalent
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured).
(a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
SUBHEAD-IV : STONE & BRICK MASONRY
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :1:6 (1 cement : 4 coarse sand) : With Modular bricks
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. Cement mortar 1:6 (1 cement :6 coarse sand) wit providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
SUBHEAD-V : MOTORISED RCC DOOR ,LEAD DOOR,STEEL, WOOD , UPVC & ALUMINIUM WORKS
Design, Manufacture, and Supply of RCC Door to site for Clear Opening Size 5000mm (w) x 5000mm (h) made in two panels with 800mm thickness and an overlap of 500mm on all sides of the door.
Design, manufacture and supply of motorized concrete door-1No as per details Given below :-
a)Wheel assembly –2 Nos suitable for 80 Tonne carrying capacity with self aligned mechanism consisting of: EN-9 forged wheels-8 Nos, “L” brackets –16 Nos, Shafts – 8 Nos, Bearings –16 Nos, Covers –16 Nos, Wheel connecting Shaft – 1No, Fasteners, geared coupling etc.
b)Top wheel assembly – 4 Nos Eccentric roller assembly with bearings, Shaft and covers to resist toppling of the Door.
c)Control panel consisting of MCBs, 16A Contactors – 3 Nos, overload relay – 1 No., push button station, limit switches 2 Nos,cabling etc.,
d)Bus bar arrangement (spring action Cable releasing drum system / Festooning system / shrouded bus bar System
e) Drive assembly including high Torque Output gearbox, Crane duty sq.cage Motor, brake coupling, rail cleaners etc.,
f) Wheel bogie to carry 80 Tonne load With uniform load distribution system For wheel assembly including Fabrication and machining
g) Limit switch 2 Nos at open and close positions of the door and over travel Limit switches
h)Rail CR-80 with fixing plates and bolts With ISMC 100 @ 2000mm c/c Stiffeners.
i)Top guide rail with ISMC 200 stiffeners @1000mm c/c
j)Two coats of epoxy paint over a Suitable coat of primer for all exposed Steel surfaces.
Providing and casting RCC M25 cement concrete for doors including providing of reinforcement, shuttering, curing etc., at site complete as per enclosed Drawing.
Erection, testing and commissioning of the motorized concrete door as mentioned above.
Design, Manufacture and Supply of RCC Door to site for Clear Opening Size 5000mm (w) x 5000mm (h) made in two panels with 750mm thickness and an overlap of 500mm on all sides of the door.
Design, manufacture and supply of motorized concrete door-1No as per details Given below
a)Wheel assembly –2 Nos suitable for 92Tonne carrying capacity with self aligned mechanism consisting of:EN-9 forged wheels-8 Nos, “L” brackets –16 Nos, Shafts – 8 Nos, Bearings –16 Nos, Covers –16 Nos, Wheel connecting Shaft – 1 No, Fasteners, geared coupling etc
b)Top wheel assembly – 4 Nos Eccentric roller assembly with bearings, Shaft and covers to resist toppling of the Door.
c)Control panel consisting of MCBs, 16A Contactors – 3 Nos, overload relay – 1 No., push button station, limit switches 2 Nos,cabling etc.,
d)Bus bar arrangement (spring action Cable releasing drum system / Festooning system / shrouded bus bar System).
e)Drive assembly including high Torque Output gearbox, Crane duty sq.cage Motor, brake coupling, rail cleaners etc.,
f)Wheel bogie to carry 80 Tonne load With uniform load distribution system For wheel assembly including Fabrication and machining.
g)Limit switch 2 Nos at open and close positions of the door and over travel Limit switches.
h)Rail CR-80 with fixing plates and bolts With ISMC 100 @ 2000mm c/c Stiffeners
i)Top guide rail with ISMC 200 stiffeners @ 1000mm c/c
j)Two coats of epoxy paint over a Suitable coat of primer for all exposed Steel surfaces.
Providing and casting RCC M25 cement concrete for doors including providing of reinforcement, shuttering, curing etc., at site completes per enclosed Drawing.
Erection, testing and commissioning of the motorized concrete door as mentioned above.
Design, Manufacture, Supply and fixing of Radiation Shielding MS Sandwich Hinged Door of Size 1.2mtr (w) x 2.2mtr (h) (Door Opening 1.1(w) x 2.1mtr (h) with 10mm Lead. The Door will be fixed to the concrete wall with two Heavy Duty point suspended hinges and locking arrangements.
Supplying and fixing of Unplasticised Poly Vinyl Chloride (uPVC) Casement windows (Openable) uPVC profiles of 60 mm x 58 mm x 40 mm X 2.20 mm (+ / - 0.05mm) for outer frames, 60 mm x 78 mm x 2.4 mm ( + / - 0.05mm) for casement shutter (sash) frames.The profiles shall be extruded with properties of impact resistance, UV Stability, corrosion resistance, colour fastness, chemical resistance, low thermal expansion, fire retarding, aging resistant, and sea water resistant of aparna venster or equivalent, outer frame and sash frame should be structurally reinforced with hot dip galvanized steel with a resistance up to 50 microns, 1.2mm thick ‘C’ type for outer frame & 1.5mm thick ‘C’ type for sash frame and should be suitable passivated for corrosion resistance for tropical deployment and should not be exposed to any drainage routing. The outer frame and the sash frame shall be prefabricated & welded through fusion welding and assembled in factory. The sash should be capable of mounting single (4/5 mm thickness) / double glazing (23 mm thickness).
The window sash shall be fitted with 5 mm thick float glass of reputed make (Saint Gobain / Ashahi / Modi) duly fixed with ethylene propylene di-monomer (EPDM) weathering seal resistant to tear & decay and exposure to ozone, ultra violet radiation and tropical climates.Accessories like friction stay hinges of stainless steel grade 304 shall be provided - 2 Nos. per sash, handle with mazak alloy casting - 1 No. per sash, multipoint locking system suitably concealed 1 No. per sash, provided with raiser wedges and cavity block for smooth operation.The window is to be installed at the site using anchor fasteners, packers & silicon rubber sealant of approved make alround the outer frame from inside and outside to absorb and buffer expansion of wall.The construction of casement window system shall have a suitable water drainage facility and shall be easy to glaze / deglaze at site etc., Casement cum fixed panel window having both end single casement panel,middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm).Providing and fixing stainless steel of 200 x 19 x 1.9 mm (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc including casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface with including screws etc. complect, as directed by Engineer-in-charge:
(Profile C) Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing 35mm thick Flush Door Shutters, with commercial ply with teak veneering on the both sides or approved equivalent make, core of block board construction with frame of first class hard wood including providing and fixing internal lipping with second class teak wood battens 25mm minimum depth on all edges of shutter, including ISI marked Stainless Steel butt hinges with necessary screws etc.,complete all as per drawings and as directed.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
i) 100mm long, 10mm dia
ii) 200mm long, 10mm dia
Al. Rubber Cleats :
i) 50mm size
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
i)Twin rubber stopper
Aluminum Aldrop 300mm long with 16mm dia rod
MS Aldrop 300mm long with 16mm dia rod
Providing and fixing of Godrej ELCO6, 6 level zince alloy door handle with body mortice lock with necessary screws etc complete as per direction of Engineer- in-charge.Make Godrej or equivalent.
Providing and fixing Heavy Duty aluminium alloy door closer extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.make-Godrej or equivalent.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856,complete as per direction of Engineer-in-charge.
Supplying, fabricating and fixing of M.S. Grills to windows & ventilators frames using MS flats, square rods all as per design etc., complete with a shop coat of primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) for fixed portion
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc to be paid separately).
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.(Mode:H Type -OGH-55-E-32x457MM,SS 202 Grade)
SUBHEAD-VI : FLOORING
Supply and laying vacuum dewatered concrete floor of 100mm thickness with R.C.C 1:2:4 (1cement : 2coars sand : 4graded aggreagate of 20mm nominal size ) laid in panels of size not more than 3M X 4M complete excluding reinforcement but including shuttering etc., all complete as per standard specifications and as directed.
Cutting grooves of size:- 4mm x 20mm deep in vacuum dewatered flooring with diamond saw cutting machine before the concrete is 7days old including providing & filling the grooves with poly sulphide of approved make (modified semi - rigid epoxy joint filler) all complete as per standard specifications and as directed.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate all as per standard specifications and as directed.
Providing and laying 2mm thick self levelling epoxy flooring using approved make and colour of M/s Fosroc make or approved equivalent by preparing the surface of floor by vacuum cleaning etc. to receive the flooring and laying the floor having the following specifications and as directed by Engineer in charge (i) Compressive strength shall not be less than 500 Kg/Sqcm in 28 days. (ii) Abrassion resistance in terms of wearing property as per IS 9162-1979 shall be 0.03mm (30 micron) or less. (iii) Surface resistivity in case of static dissipative type is between 106 and 109 ohms when mesured for surface resistance in accordance with BS2050: 1978 (A-1984) and DIN/EN 1081 (The minimum value shall not be less than 106 ohms) all complete as per manufacturers specifications and as directed.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying double charged Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete..
Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Makes : Johanson , sandex Series or equivalent
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles of size 300x400mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing Decorative pressed cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Light shade pigment using white cement
SUBHEAD-VII : PLASTERING & SURFACE TREATMENT
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including Water proofing Compound.
White washing with lime to give an even shade New work (three or more coats) :complete all as directed by Engineer - in - Charge.
Providing and fixing Chicken wire Mesh 22 Guage of approved make with all necessary hard ware at the junction of RCC and brick work with required overlapping as directed by Engineer-in Charge etc., complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shadeNew work (two or more coats) over and including water thinnable priming coat with cement primer :complete all as directed by Engineer - in - Charge.
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm as directed by Engineer - in - Charge.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including Synthetic Enamel Paint
SUBHEAD-VIII : FALSE CEILING
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,
including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with including all neccssary fittings liks fastners,screw,nuts,bolts,tee rod ect complectly :(Make : Gproc , L Strong , Armstrong)
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS Certification marks)(Make : Gproc , L Strong , Armstrong)
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameterfully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6
SUBHEAD - IX : ROOF WORK
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge . With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with polymer based water proofing cement compound of approved make @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
SUBHEAD- X: STRUCTURAL STEEL WORK
Supplying and fixing Rolling Shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing and fixing stainless steel (Grade 304) Railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Structural steel work riveted, grantry,girders, gutter, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing bolts including nuts and washers complete.
Providing and fixing MS hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. MS Tube
Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
SUBHEAD- XI: MISCELLANEOUS
RAIN WATER PIPE
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
Single socketed pipes of 110mm diameter
Single socketed pipes of 150mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler
110mm Bend 87.5°
150mm Bend 87.5°
110mm Shoe (Plain)
150mm Shoe (Plain)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
SUBHEAD-XII : ROADS & STORM WATER DRAINS
Supplying & Stacking Good Earth brought from outside MoD land including compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).(Deduction shall be made for 5% voids)
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler,transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
25 mm compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity
Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.
On W.B.M / W.M.M. @ 0.4kg/sqm
On bituminous surface @ 0.25kg/sqm
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
600 mm dia. R.C.C. pipe
Providing and laying plain cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) including shuttering if required in leveling courses under foundations, pipelines, pits, under floors etc., complete at all levels and locations as directed by Engineer - in - Charge.
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand).
Banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden of steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50m and lift upto 1.5 m in all kinds of soils
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed, in Hard Rock (Blasting Prohibited) a) Lift Upto 1.5m
SUBHEAD-XIII : SANITARY SERVICES
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid. (Make : Jaquar or equivalent)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : (Make : Jaquar or equivalent)
Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing soil, waste and vent pipes, Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
100mm dia.
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
100mm dia.
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
For 100mm dia. pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for Sand cast iron S&S as per IS - 3989
100mm dia.
Providing and fixing plain bend of required degree, for Sand cast iron S&S as per IS - 3989
100mm dia.
Providing and fixing heel rest sanitary bend, Sand cast iron S&S as per IS - 3989
100mm dia.
Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989
100 mm inlet and 75 mm outlet
Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :
100mm dia.
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
100 mm diameter pipe
Supply and fixing in position best quality and approved make Stainless steel double coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. Model No. AKP-35761P of M/s Jaguar make or equivalent
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 455x610 mm and 45 cm deep for single pipe line, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets.
SUBHEAD-XIV : WATER SUPPLY SERVICES
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. Brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps of M/s jaquar make or of approved equivalent make as directed by engineer in charge
Providing and fixing beveled edge mirror of size:- 600x450 mm superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Supply and fixing of Two way Bib cock with wall flange including all necessary fittings of approved make etc., complete Two way Bib cock Model No. FON-40041 of M/s Jaquar make or approved equivalent make.
Supply and fixing of 1.00 mts long easy flex tube with end nuts and hook and Health Faucet all complete. Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete Health Faucet (ABS Body) with 1m long easy flex tube in chromo finish and wall hooks Model No. ALD-CHR-585 of M/s Jaguar make or approved equivalent make.
Providing and fixing Stainless steel Towel ring Square with round flange with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour. Towel Ring Model No. ACN-11121N of M/s Jaguar make or approved equivalent make.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc., for Internal work - Exposed on wall
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
500 Litres Capacity
1000 Litres Capacity
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore jaquar make modal no:opp-chr-15037pm
Providing and fixing brass stop cock of approved quality : 15 mm nominal bore
Providing and fixing CP liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc.,including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge
Granite/ Marble work
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required
Kitchen sink with drain board 510x1040 mm and bowl depth 250 mm
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
Providing and fixing PVC 75mm size Nahani Trap of approved make (Supreme) conforming to ISI Specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot)
SUBHEAD-XV : SEWAGE DISPOSAL
Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
100 mm diameter
150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
100 mm diameter S.W. pipe
150 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
100 mm diameter S.W. pipe
150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
100x100 mm size P type With Sewer bricks conforming to IS : 4885
Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
RAIN WATER HARVESTING
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.
All kinds of soil
Ordinary rock
Hard rock (Blasting prohibited)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation :
Cement mortar 1:6 (1 cement : 6 coarse sand).
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including Water proofing
Supplying, assembling, lowering and fixing in vertical position in unplasticized PVC pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
uPVC blind pipe 200 mm dia as per IS: 12818
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the of 300mm depth required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of 200mm depth size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately)
All works upto plinth level.
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.
a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for:
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
Suspended floors, roofs, landings, balconies and access platform.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
SUBHEAD-XVI : EXTERNAL WATER SUPLY
Surveying the area by specialist agencies to locate points with electro Location resistive method for drilling 150mm Dia bore well
Drilling of borewell 150mm dia in any type of soil including rock granites up to the following depths at one specified point including all Labour material and equipment.
(a) Upto 30m
(b) 31m to 60m
(c) 61m to 100m
( e ) 131m to 160m
(f) 161m to 200m
Providing PVC blue casing pipe (10 kg/sq.cm) of 150 mm dia. in borewell conforming to IS:12818 .
Supply, erection, testing and commissioning of submersible Pump Set 7.5 HP 10stage with ISI mark.
Supply, erection, testing and commissioning of 2.5Sq.mm 3 core copper cable flat water proof inside borewell and laid over ground suitable for submersible pump along with PVC conduit where required all complete.
Supply and laying of 3 core 16 Sqmm and PVC underground cable with end terminating including excavation of soil with protection back filling etc.,complete as per IS specification.
Supply , fixing , testing and commissioning of suitable size MS weather proof enamel paint coated outdoor type box with locking arrangement , provision of fixing item at SL.NO.(viii) above complete pedestal and all accessories etc., as approved and specified by the engineer/ Site incharge.
Providing HDPE pipe PE-63 grade (12.5 kg/ sq. cm) of 63 mm OD mm dia.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
a) All kinds of soil
Providing and laying plain cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) including shuttering if required in leveling courses under foundations, pipelines, pits, under floors etc., complete at all levels and locations as directed by Engineer - in - Charge.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete.
i)Thermo-Mechanically Treated bars (Fe 500 Grade)
Centering and shuttering including strutting, propping etc. and removal of form for :
a) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
6 mm cement plaster of mix
1:3 (1 cement : 3 fine sand)
Providing,laying & fixing of CI cover with frame of size 600x600mm including all necessary fittings etc as per direction of the Engineer-in-charge.
Providing,laying & fixing of rungs including all necessary fittings etc as per direction of the Engineer-in-charge.
SUBHEAD-XVII: FURNITURE
Supply of Model Companion Range of Computer Tables Colours: Cherry Brown, Honey, Bavarian Beech C2 120 cm 60 cm 75 cm. Make:- Godrej /Wipro/Featherlite or equivalent
Supply of computer table of Model Companion C13 Computer Table Walnut. All these models made of particle board feature keyboard pull out trays and lockable castors of Diamension (101.5Wx59.4Dx75H)cm. Make:- Godrej /Wipro/Featherlite or equivalent
Supply of computer table of Model STYLO Computer Table having features of Aesthetic appeal that comes with its all-wood construction,Ample storage with 2 box and 1 file drawers , CPU and keyboard space provided of Diamension (120Wx60Dx75H)cm. Make:- Godrej /Wipro/Featherlite or equivalent
Supply of Computer chairs of Model Diva 7042R containing the features of Permanent Contact Mechanism, Plastic Seat/Back Cover,Pronged Base,Ergonomic Back,Moulded Foam & Pneumatic height adjustment.the chair Diamenion are (71Wx71Dx80.10-91.10H)cm with seat height 43-53cm. Make:- Godrej /Wipro/Featherlite or equivalent
Supplying of Executive Chairs of Model PRIMER 7102R having the features of like Center Tilt Mechanism,Tilt Locking,Moulded Foam,Pneumatic height adjustment,Swivel Mechanism,Twin wheel castors & chair Diamenion are (70Wx70Dx79.9-90.9)cm with seat height 42.4-53.4cm. Make:- Godrej /Wipro/Featherlite or equivalent
Supply of working table INSIGHT 1800W of overall length of the dining table for 6 persons 1500mm x 900mm,height of the table 750mm.wooden legs of size 75mmx75mm all around 18mm ply with 1mm lamination on the top fitted with screws to the frame from the bottom.Two side stiffeners and one centre stiffener shall be provided complete with spirit polish. Make Godrej /Wipro/Featherlite or equivalent.
Supplying of working chair Motion High Back - Charcoal Grey With Grey Body including fixed Arm rests,Choice of fixed or adjustable armrest is available Diamenion are (76Wx 76Dx99.50-108.80H)cm with seat height 44.50-53.80cm.Make Godrej /Wipro/Featherlite or equivalent.
Supplying of Storwel plain shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Make:- Godrej/Wipro/Featherlite or equivalent.
Supplying & placing of Glass Door Storwel shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The glass door storwel shall have a brass handle and a 2 way locking mechanism with shooting bolt . It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Make:- Godrej/Wipro/Featherlite or equivalent
Supplying of Special Documents storage Steel almirah with 40 Drawer Filling Cabinets storwell to keep films & Accessories of storwell plain 16 gauge G.I sheet with apporived paint over primer Dimensions: Length 507 mm, Width 900mm Height 1500 mm .Make Godrej /Wipro/Featherlite or equivalent
Supplying of Model Senate Conference Table (10 Seater) with Wire Manager size shall be Single seater 760 Width mm x 600 Depth mm , Two seater 1360 Width mm x 600 Depth mm , Half Round (2 Seater ) R 713 + Quarter Round ( 1 Seater ) R 713 . The top shall be 31.6 mm thick (18 mm + 12 mm + 0.6 mm DL ( both sides ) + 0.4 mm Membrane ) Edge Profile shall be waterfall edge 10 mm radius on top edge and 5 mm at bottom . In Understructure the Legs shall be made from 25 mm PPB having a straight profile with half round edges and clad with 0.6 mm thick post Forming laminate. Overall thickness of leg shall be 26.2 mm. The modesty panel in understructure shall be made from PLT ( Pre laminated twin) boards of 18 mm thickness. There shall be Wire Management wire carrier shall be made from 0.6 mm thick CRCA painted and carrier cover shall be made of 12 mm thick MDF painted all over. Make Godrej /Wipro/Featherlite or equivalent
Supplying of chair for technical discussion table of Model - OXBO Mid Back. It contains the features of High Back, Full Back ,thicker Seat Cushion for solidity in Style,Unique tubular frame back – Designer touch,Mesh upholstery on back – Trendy and light,Complimenting slim but wide Loop Armrests. Make:- Godrej/Wipro/Featherlite or equivalent.
Supplying of Shoe rack in inspection area of Model Alpha shoe cabinet walnut of the Dimensions:Width 18.9inch ,Depth 9.4inch , Height 48.8 inch. Make:- Godrej/Wipro/ Featherlite or equivalent.
Supplying of step in shoe cabinet tex moonlit of the Dimensions: Length (14 cm), Width (50 cm), Height (110.8 cm) & Primary Material: CRCA Steel of Color: Purple, Finish: Glossy, Style: Contemporary. Make:- Godrej/Wipro/ Featherlite or equivalent.
SUBHEAD-XVIII : AREA DEVELOPMENT
Supply and filling good earth brought from out side MOD land filling in layer not exceeding 20 cm thickness at all height and depth including levelling, watering compaction etc. inside building including compacting to OMC etc. complete (deduction will be made for 5% voids)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand).
SUBHEAD-XIX : CHAIN LINK FENCING
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m
Hard rock (blasting prohibited)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Raised and cut pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Providing and applying With ready mixed ` oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel worksat all levels and locations etc., complete all as directed by Engineer - in - Charge:a) Steel surfaces with zinc chromate primer
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
SUBHEAD-XX : ARBORICULTURE
Supply of Grass and planting by dibbling the area including watering & Maintenance of Lawn for 30 days or more till grass forms a thick lawn cushion free from weeds. With Doob Grass (15 cm x 15 cm apart) including one year maintenance after completion of work
Trees:- Digging of pits of size 1x1x1m and refilling with good agriculture soil and well decomposed cattle manure in 4:1 ratio. Supply and planting of approved Tree species of healthy grownup saplings with good root system. Saplings should be of minimum 4 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide, including one year maintenance after completion of work
Shrubs: Digging of pits of size 0.60x0.60x0.60m and refilling with good agriculture soil and well decomposed cattle manure in 3:1 ratio. Supply and planting of approved Shurbs species of healthy grownup saplings with good root system. Saplings should be of minimum 2 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide,including one year maintenance after completion of work
Hedges: Digging of trenches of size 0.30 x 0.30m (width & depth) and refilling with good agriculture soil and cattle manure in 4:1 ratio. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, pruning, shaping and spraying of insecticide and fungicide,including one year maintenance after completion of work
Flower Beds: Digging upto 0.10m refilling with good soil and cattle manure in 3:1 ratio. Preparation of beds supply and planting of healthy grown up plant material. Maintenance includes regular watering, de-weeding, manuring with manure and fertilizer.pruning, shaping and spraying of insecticide and fungicide,including one year maintenance after completion of work
Potted Plants: Supply and maintaining the Indoor and Outdoor potted plants in a good healthy and disease free condition of various varieties and in 300 mm Dia.PVC Plastic Pot.
Pipe Line:- Supply, fixing, testing and commissioning of HDPE pipes with spray nozzles ISI mark with all required accessories, outlet points etc., (excluding excavation in hard rock if any will be measured separetly) in all kind of soil, back filling and ramming as required and disposal of surplus earth within the site, as directed by Engineer - in - charge.
50mm dia
63mm dia
SUBHEAD-XXI : EOT CRANE
PART I :- SUPPLY OF EOT CRANES
Design,manufacture and supply of following double girder Flame proof EOT Crane with all speed VVVF Drive control and micro speed arrngement for Hoist CT & LT as per the specifications and conforming to IS 807/ IS 3177 and other relevent IS standards of the latest revisions as shown below complete with the cost of paint as required.
5 Ton Capacity double girder crab type EOT Crane with Hoist long travel and cross travel movements as per technical specification and as per IS 807 & 3177 and other relevant IS standards of the latest revision. All the drives shall be provided with alternative parallel with DOL starter for main speeds only.
Building :RADIATION ROOM -II Span : 12Mtr(+/- 0.5 Mtr) Lift :9 Mtr Bay Length :15 Mtr
Building :RADIATIION ROOM-I Span : 12Mtr(+/- 0.5 Mtr) Lift :6Mtr Bay Length :15 Mtr
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures.
Supply of material for Gantry Rails section 40 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder all complete as per the directions of Engineer-in-charge.
PART-II:- ERECTION TESTING AND COMMISSIONING
Erection, testing and commissioning of EOT crane and other allied items mentioned in Part-I as per the relevant IS standards comprising the following
a) Erection, testing and commissioning of 5 Ton capacity crab type EOT crane mentioned in Part-I as per the relevant IS standards inclusive of installation of complete Crane completion of all electrical and mechanical works including performance tests with No load, Full load and over load testing all as per the directions of Engineer-in-charge.
b) Erection testing and commissioning of shrouded type current collection system complete as per the Part I over the crane bay including tapping of supply for electrical panel all as per the directions of Engineer-in-charge.
c) Erection, testing & commissioning of Gantry rail section 40 Square bar mentioned in Part -I with mounting arrangement and fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation all as per the directions of Engineer-in-charge.
SUBHEAD - XXII : WATER COOLER
Supply , installation testing and commissioning of storage water cooler with storage capacity of 80 liters and cooling capacity of 40 liters suitable for operation on 230V, 50 HZ, full stainless steel body including RO Purification system , 2 KVA voltage stabilizer etc complete
SUBHEAD XXIII : AIR CONDITIONING
VRF SYSTEM:
Supply, Installation, Testing and Commissioning of following capacities of Vairable Refrigerant Flow (VRF / VRV) Outdoor condensing unit comprising of Invertor SCROLL compressor's, Heat Exchanger, propeller / axial fans, refrigerant Circuit, Safety Devices & Oil Recovery System, operating on R410a refrigerant gas. Necessary Refrigerant Gas and oil charge. Compressor shall be equipped with inverter controller of Insulated Gate Bipolar Transistor (IGBT) type to be efficient & quiet. The outdoor unit shall have the multi-step of capacity control to meet load fluctuation and indoor unit individual control. Heat Exchanger shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. Refrigerant Circuit shall include an accumulator, liquid and gas shutoff valves and a solenoid valves. The Outdoor unit shall include the following safety devices : High pressure switch, Low pressure switch, Fan motor safety thermostat, Inverter overload protector, Over Current relay, Fusible plugs, Fuses etc .
Unit shall be equipped with an oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be prewired in factory for necessary power and control wiring. All outdoors units shall be mounted with necessary vibration isolators ,Complete clamping and saddling of cabling work and refrigerant piping; as per the specifications and approved drawingsNominal Cooling Capacity at ARI conditions
40 HP OUT DOOR UNIT (20+20)
30 HP OUT DOOR UNIT (14+16)
18 HP OUT DOOR UNIT
CEILING SUSPENDED UNIT (CSU)
Supply, Installation,Testing and Commissioning of High Static Ducted type Indoor unit with pre-filter (EU - 4),fan section with low noise level, multispeed fan motor, coil section with DX coil, outer cabient, condensate drain pump, insulation, pipe connections, including necessary control wiring, required Fire retardant canvass connections with GI . powdercoated finish angle flanges on both sides,etc. as necessary. Unit to be provided with microprocessor with Corded remote controller as per the specifications and approved drawings.
AIR HANDLING UNITS (AHU):
32 TR/13000 CFM @ 50MM TSP
REF. PIPE JOINTS
Supply, Installation, Testing and Commissioning of Refrigerant Piping Joint For Suction Line.
Supply, Installation, Testing and Commissioning of Refrigerant Piping Joint For Liquid Line.
AHU KITS
Supply, Installation, Testing, & Commissioning of AHU kits, with all necessary equipment to control the flow of refrigerent as per the load conditions, etc, as per the specifications
CENTRAL CONTROLLER
Supply, Installation, Testing and Commissioning of CENTRALISED Remote Controller advanced I Touch Controller
REFRIGERANT PIPING:
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING of 16swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering and covered with 24G AL cladding for exposed Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING of 16swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering for inside Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
DRAIN PIPE:
Supply, Installation, Testing and Commissioning of CPVC (Chlorinated Poly Vinyl Chloride) pipes condensate drain piping insulated using 9 mm thick nitrile rubber tubes including fitting and supports as per the specifications and approved drawings.
AIR DISTRIBUTION SYSTEM
Supply, Installation, Testing and Commissioning of factory fabricated GSS Ducting as per SMACNA/DW standards with splitters,bends, elbows, vanes, supports,neoprene of minimum 6mm thick gasket, nuts, bolts angle iron flanges, soildered longitudinal joints ,GI full threaded rods hung to minimum 12 mm dia HILTI make anchor fastner as required and epoxy painted slotted rail supports ,as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of factory fabricated 25 MM thick Pre Insulated(FRP-Fibre Glass Reinforced Plastic) Box type Ducting with factory laminated aluminium foil finish on both sides, with Aluminium joint fixtures, with proper sealent on edges; having density 75-80 kg/m3 (at edges of panels should have 150 kg/m3), thermal conductivity 0.033 W/m-K at 10°C, with Euroclass C-s1 & d0; as per EN 13403 & SMACNA/DW standards with splitters,bends, elbows, vanes, supports, gasket, nuts, male/female edges, Aluminium full threaded rods and slotted rail supports, etc. as scheduled as per the specifications and approved drawings.. (Note: Aluminium suppoers & joints, etc. to be used for installation)
INSULATION
Supply, Installation, Testing and Commissioning Thermal Insulation of Supply air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives and finished with 0.05mm thick 3" wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning Thermal Insulation of Return air ducting with 13mm thick closed cell elastrometric Nitrile rubber with factory laminated Aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives and finished with 0.05mm thick 3" wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawings
Supply, Installation, Testing and Commissioning Thermal Insulation of EXPOSED Supply air ducting with 25mm thick closed cell elastrometric Nitrile rubber with of density minimum 43Kg/m3, and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and covered with 7 mil thick chemically treated woven glass cloth having density 205+/- 10 g/sqm and affixed using synthetic contact adhesive of approved make , further finished with 24G Aluminium cladding as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning Thermal Insulation of EXPOSED Return air ducting with 19mm thick closed cell elastrometric Nitrile rubber with of density minimum 43Kg/m3, and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and covered with 7 mil thick chemically treated woven glass cloth having density 205+/- 10 g/sqm and affixed using synthetic contact adhesive of approved make further finished with 24G Aluminium cladding as per the specifications and approved drawings.
Supply & Installation of Duct Accoustic Insulation with microban applied inside of the duct work with 10MM thick Nitrile Rubber fixed using sticker pins and adhesive. Material density minimum of 140 kg/m3 & conform to Class 1 surface spread of flame as per BS 476 Part7 and in accordance with UL 94, 1996 and tested as per ISO354 for sound absorption coefficient.
DAMPERS,GRILLES & DIFFUSERS
Supply, Installation, Testing and Commissioning of Opposed type GI Volume Control dampers with matching flanges of sizes as per the approved drawings
Supply and Installation of Fire dampers with fusible links&Eletronic actuators connected to FA system with frame etc. (Dampers should be of wall / duct mounted) as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated ceiling square diffusers for Supply & Return as per the specifications and approved drawings.(Colour to be aproved by dept)
Supply, Installation, Testing and Commissioning of Extruded Al. continuous/ discontinuous grills for Supply & Return as per the specifications and approved drawings.(Without powder coating)
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Al. Collar Dampers as per the specifications and approved drawings.(Colour to be aproved by dept)
Supply, Installation, Testing and Commissioning of weather proof extruded aluminium powder coated fresh air louver of non vision type of Perforated Al net, VCD etc as per the specifications and approved drawings.
ELECTRICAL
Supply, Installation, Testing and Commissioning of Outdoor type panel with 400A 4-pole MCCB incomer,Aluminum busbars with 0.8A/Sqmm rating for Outdoor Units (equipment) enclosed in a weather proof box suitable for out door application with class protection not less than IP - 65 with - Outgoing: OUTGOING: 4-pole 63Amps, 16KA MCB - 3 Nos. 4-pole 40Amps, 16KA MCB - 2 Nos. 4-pole 32Amps, 16KA MCB - 1 Nos. 4-pole 16Amps, 16KA MCB - 2 Nos. (1working + 1Spare) Voltmeter, Ammeters, Indication lamps shall be provided as required.
Supply, Installation, Testing and Commissioning of POWER CABLING of Copper cable for indoor / outdoor units to be suitably laid in PVC conduit as per site requirement.
4C x 16 sq.mm. (Copper)
4C x 10 sq.mm. (Copper)
4C x 6 sq.mm. (Copper)
3C x 2.5 sq.mm. (Copper)
Supply, Installation, Testing and Commissioning of CONTROL CABLING of 3C x 1.5 sq.mm. copper cable for communication between indoor and outdoor units to be suitably laid in PVC conduit as per site requirement.
Supply, Installation, Testing and Commissioning of REMOTE CABLING of 4C x 1.0 sq.mm. copper cable for communication between indoor and outdoor units to be suitably laid in PVC conduit as per site requirement.
EARTHING SYSTEM:
Supply, Installation, Testing and Commissioning of GI flat 25 mm x 3 mm.
Supply, Installation, Testing and Commissioning of Single core Green PVC insulated 2.5 sq mm. wire.
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type 300mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type 150mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.
FRESH AIR FANS
Supply, Installation, Testing and Commissioning of Inline Ducted Fresh Air Fan complete with TEFC Motor with suitable supports and other accessories complete of following capacities .
200 cfm @15mm TSP
FRESH AIR DUCT
Supply, Installation, Testing and Commissioning of PVC (Poly Vinyl Chloride) pipes for supplying the fresh air including using 9 mm thick nitrile rubber tubes including fitting and supports as per the specifications and approved drawings.
160 mm dia (6Kg/sq.cm)
110 mm dia (6Kg/sq.cm)
75 mm dia (6Kg/sq.cm)
SUBHEAD XXIV : INTERNAL ELECTRIFICATION
Point Wiring for Light/ Fan/ exhaust fan with 2runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm FRLS , PVC insulated Copper wires, run in 25 mm dia 2 mm thick PVC conduits concealed in wall / on wall / concealed in ceiling / on surface conforming to IS 732 including all accessories such as junction boxes, conduit bends elbows and ceiling rose, anodised GI Switch box with modular switch and the box covered with front plate.
One light point controlled by one 6A switch
Two light point controlled by one 6A switch
Three light point controlled by one 6A switch
Fan Point controlled by one 6A switch with modular type Electronic regulator of 100 Watts step type and concealed M.S.Fan hook and box.
Exhaust fan point controlled by one 6A switch.
Supply and fixing of 6A, 5Pin Socket outlet with switch of 6A rating on switchboards (Dependant).
Supply,Installation,Testing and commissioning of the following Luminaires with LED tube Lights with reflectors and with Drivers and Electrical accessories including the supply of Drivers and also including the supply of fixing brackets ,fixing chain fixing clamps etc complete.
11 W , Recess Mounted Down lighter of LED Fixture with Initial luminous flux (system flux) 1200 lm ( Philips Cat No : DN198B led 3s-6500 PSU WH MB)
11 W , Surface Mounted Down lighter of LED Fixture with Initial luminous flux (system flux) 1200 lm ( Philips Cat No : DN198B led 3s-6500 PSU WH MB)
20 W , 4 Feet length Sleek Surface mounted LED Light Fixture with Lumen Output (lm) 2000 (Philips Cat :BN021C LED20S PSU NW GR )
Supply and fixing of 1400 mm sweep ceiling fan with standrad down rod , all accessories electrical connections including fixing materials required (without regulator)
Supply and Installation of heavy duty Exhaust fans with Metallic blades following size sweep with gravity louvres shutters including all fixing accessories.
Supply and Wiring with the following size 1100V grade FRLS PVC insulated multistrand Copper conductor wires in suitable size 2 mm thick PVC conduit concealed in wall / on wall / concealed in ceiling / on ceiling including junction boxes, bends, elbows including with suitable lugs for connections
2 runs of 1.5Sq.mm with 1run of 1.5 Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
2 runs of 2.5Sq.mm with 1run of 1.5 Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
3 runs of 4Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
3 runs of 6Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
Supply and fixing of 6A, 5Pin Socket outlet with1 No of 6A rating switch (Independant) with all internal connections.
SUBHEAD XXV : POWER WIRING
Supply and fixing of modular type 6/16A 5pin shuttered type Socket with 16A switch , front plate and anodised GI box, complete including all fixing accessories.
Supply, Installation, Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB/ ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS: 8828 and ELCB /RCCB shall conform to IS : 12640
6Way TPN MCB LDB (Horizontal type Non flame Proof) with 40A, 4Pole MCB with as incomer and 18 nos 6-25A SPMCBs as outgoings (LDB).
6Way TPN MCB PDB (Horizontal type Non flame Proof) with 63A, 4Pole MCB with as incomer and 18 nos 6-25A SPMCBs as outgoings (PDB).
Supply, fixing, Testing and Comissioning of factory made 25A, 1Ph Metalclad socket with 25A SPMCB in MS box including all fixing accessories ( from RPDB) for AC Points
Supply, fixing, Testing and Comissioning of factory made 32A, 1Ph Metalclad socket with 32A SPMCB in MS box including all fixing accessories (from RPDB)
Supply, fixing, Testing and Comissioning of factory made 63A, 1Ph Metalclad socket with 63A SPMCB in MS box including all fixing accessories (from RPDB)
Supply and Wiring with the following size 1100V grade FRLS PVC insulated multistrand Copper conductor wires in suitable size 2 mm thick PVC conduit concealed in wall / on wall / concealed in ceiling / on ceiling including junction boxes, bends, elbows including with suitable lugs for connections
2 runs of 1.5Sq.mm with 1run of 1.5 Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
2 runs of 2.5Sq.mm with 1run of 1.5 Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
3 runs of 4Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
3 runs of 6Sq.mm wires in 25mm Dia , 2 mm thick PVC conduit .
SUBHEAD XXVI : SHOP ELECTRICS
LT Panel
The switchboard shall be indoor construction, free standing, cubicle type modular construction, dust & vermin protected.The switchboard shall complies to latest edition of IEC 61439-1&2, Test certificate shall be issued by a reputed authority.The equipment shall be suitably constructed for safe, proper and reliable operation without undue wear, corrosion, heating or other operating trouble.The weatherproof housing shall be manufactured from Hot Galvanized Iron confirming to international specification and suitable for mounting on a flat concrete base or pier 300 mm above ground level. The enclosure frame shall be from OEM. The frame shall be of bolted design made of Galvanized iron with 9 fold structure for better rigidity and strength with 275GSM. No welding frame to be considered.
All the load bearing members shall be made of 2mm thick CRCA sheet steel and it shall be of a totally enclosed design with cables entering from the Top/bottom and secured by cable cleats or glands and maintains equipotentiality of the switchgear. The housing shall be arranged for front access/Rear access by means of hinged doors which shall be screwed to secure them. The rated impulse withstand voltage of the system shall be 8kV for ACB & MCCB feeders.The Electrical Panel shall have a rated short time withstand current of 50 kA for 1 second.The busbar will be designed for mounting on insulated supports that are sufficient in number to accept the flow of peak short circuit current upto 254kA. The switchboard Main distribution panel shall restrict the internal arcs faults within the compartment to ensure maximum safety to the operating personnel and also to minimize the downtime for replacement and repairs.
Type test certificate shall be carried out to verify the arc containment within the compartment for 50kA, 0.3sec as per IEC 61641. The Switchboard shall have Seismic withstand of Zone –IV. Even under extreme condition of short circuit or Mal-operation there will be no danger in the vicinity of the assembly.The switchboard shall be with Outer glass door with gasket to prevent from accidental / unauthorized operation of switchgears.The glass should be of minimum 4mm thick which should comply Mechanical impact of IK-09. The doors should be with pre-assembled handle (reversible) with 4 closing points must be used, double tongue standard type with locking system must be chosen. No hylam sheets to be used for segregation, GI sheet is preferable.
LT Cable
Supply, laying, Testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/Part II.
3.5C X 95 Sq.mm
3.5C X 50 Sq.mm
3.5C X 35 Sq.mm
4C X 16 Sq.mm
4C X 10 Sq.mm
LT Cable Terminations
Providing Indoor ordinary end terminations for the cable specified below with compression type steel gland, Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc.,including end termination and Earthing of Gland.
3.5C X 95 Sq.mm
3.5C X 50 Sq.mm
3.5C X 35 Sq.mm
4C X 16 Sq.mm
4C X 10 Sq.mm
Cable Tray
Supply and installation of cable tray of ladder type for armored cables or perforated GI cable tray for PVC conduits of the following sizes with all necessary supports and accessories etc., complete.
750x50mm Ladder Type Cable Tray
450x50mm Ladder Type Cable Tray
Earthing
Providing maintenance free Earth station with consisting of 40mm dia pipe standard length(as per equipment supplier)electrode capsule,filled with earth enhancing compound ,sealed at both ends and brazed lead for connection at one end.suitable for direct installation at side ,at a depth of 2.5mts.Earth enhancement compound up to a depth of 2mts around the electrode capsule ,brick chambers and CI cover complete.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
32 X 5mm Aluminium strip with DMC Insulated Supports
50 X5mm GI strip laid in ground
SUBHEAD XXVII : UPS WIRING
Point Wiring for Light/ Fan/ exhaust fan with 2runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm FRLS , PVC insulated Copper wires, run in 25 mm dia 2 mm thick PVC conduits concealed in wall / on wall / concealed in ceiling / on surface conforming to IS 732 including all accessories such as junction boxes, conduit bends elbows and ceiling rose, anodised GI Switch box with modular switch and the box covered with front plate.
One light point controlled by one 6A switch
Two light point controlled by one 6A switch
Three light point controlled by one 6A switch
Supply and fixing of 2nos of 6A, 5Pin Socket outlet with1 No of 6A rating switch on Seperate switchboards (Independant) with all internal connections.
Supply and fixing of modular type 6/16A 5pin shuttered type Socket with 16A switch , front plate and anodised GI box, complete including all fixing accessories.
Supply and fixing of factory made 32A, 1Ph Metalclad socket with 32A SPMCB in MS box including all fixing accessories ( from UPDB)
Supply and fixing of factory made 63A, 1Ph Metalclad socket with 63A SPMCB in MS box including all fixing accessories (from UPDB)
Supply, Installation, Testing and commissioning of TPN/SPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB/ ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS: 8828 and ELCB /RCCB shall conform to IS : 12640
6Way TPN MCB LDB (Horizontal type Non flame Proof) with 40A, 4Pole MCB with as incomer and 18 nos 6-25A SPMCBs as outgoings (ULDB).
6Way TPN MCB LDB (Horizontal type Non flame Proof) with 63A, 4Pole MCB with as incomer and 18 nos 6-25A SPMCBs as outgoings (UPDB-1).
12Way TPN MCB PDB (Horizontal type Non flame Proof) with 63A, 4Pole MCB as incomer and 36 nos 6-25A SPMCBs as outgoings (UPDB-2).
Earthing
Providing maintenance free Earth station with consisting of 40mm dia pipe standard length(as per equipment supplier)electrode capsule,filled with earth enhancing compound ,sealed at both ends and brazed lead for connection at one end.suitable for direct installation at side ,at a depth of 2.5mts.Earth enhancement compound up to a depth of 2mts around the electrode capsule ,brick chambers and CI cover complete.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
32 X 5mm Aluminium strip with DMC Insulated Supports
50 X5mm GI strip laid in ground
UPS Panel
The switchboard shall be indoor construction, free standing, cubicle type modular construction, dust & vermin protected.The switchboard shall complies to latest edition of IEC 61439-1&2, Test certificate shall be issued by a reputed authority.The equipment shall be suitably constructed for safe, proper and reliable operation without undue wear, corrosion, heating or other operating trouble. Panel builder shall produce valid licensed agreement made with original manufacturer.The weatherproof housing shall be manufactured from Hot Galvanized Iron confirming to international specification and suitable for mounting on a flat concrete base or pier 300 mm above ground level. The enclosure frame shall be from OEM. The frame shall be of bolted design made of Galvanized iron with 9 fold structure for better rigidity and strength with 275GSM. No welding frame to be considered.
The switchboard Main distribution panel shall restrict the internal arcs faults within the compartment to ensure maximum safety to the operating personnel and also to minimize the downtime for replacement and repairs. Type test certificate shall be carried out to verify the arc containment within the compartment for 50kA, 0.3sec as per IEC 61641. The Switchboard shall have Seismic withstand of Zone –IV. Even under extreme condition of short circuit or Mal-operation there will be no danger in the vicinity of the assembly.The switchboard shall be with Outer glass door with gasket to prevent from accidental / unauthorized operation of switchgears.The glass should be of minimum 4mm thick which should comply Mechanical impact of IK-09. The doors should be with pre-assembled handle (reversible) with 4 closing points must be used, double tongue standard type with locking system must be chosen. No hylam sheets to be used for segregation, GI sheet is preferable.
All the load bearing members shall be made of GI sheet steel and it shall be of a totally enclosed design with cables entering from the Top/bottom and secured by cable cleats or glands and maintains equipotentiality of the switchgear. The housing shall be arranged for front access/Rear access by means of hinged doors which shall be screwed to secure them. The rated impulse withstand voltage of the system shall be 8kV for ACB & MCCB feeders.The Electrical Panel shall have a rated short time withstand current of 50 kA for 1 second.The busbar will be designed for mounting on insulated supports that are sufficient in number to accept the flow of peak short circuit current upto 254kA.
SUBHEAD XXVIII : LIGHTENING PROTECTION
Supply, Installation, Testing and Comissioning of Lighting Arrestor with all below accessories as per IS-IEC-62305
Supply of 10 mm dia and 600 mm length solid aluminum blunt tip Air termination with Base plate (Vertical air terminal with accessories: Providing of Air terminals as per IS-IEC -62305).
Supply of standing seam clamp for fixing conductor holder fixing of AT on metallic roof.
Supply of 8 mm dia solid Aluminum Conductor for roof top mesh grid meets the requirement of IS IEC 62305 (As specified in Drawing) and tested as per IEC 62561.
Supply of 8 mm dia solid Aluminum Conductor for DOWN CONDUCTOR meets the requirement of IS IEC 62305 (As specified in Drawing) and tested as per IEC 62561.
Supply of Al conductor holding clamp suitable for mesh grid conductor ,.Conductor holder @ 1 meter distance as per IS IEC 62305.
Supply of Al conductor holding clamp suitable for Down conductor with special arrangement ,.Conductor holder @ 1 meter distance as per IS IEC 62305.
Supply of standing seam clamp for fixing conductor holder fixing of Conductor on metallic roof.
Supply of Straight Splicers for Aluminium Conductor tested as per IS IEC 62305 and tested as per IEC 62561 Standard.
Providing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation meets the requirements of IS / IEC 62305 tested as per IEC 62561.
Supply of Expansion Piece connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters with Expansion Piece Straight Splicers for expansion piece with Connector for to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305.
Suply of 25 X 6 mm GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding.
Supply of conductor holding clamp suitabe for 25 X 6 mm GI strip(JEF Make of Type JICL08)
Each down-conductor should be provided with a test link in order to disconnect the earth termination system for enabling measurements. Test link- SS for Round to Flat conductor for 8-10mm OD & 25 x6 mm S S Test Link without Enclosure for conductor to Strip (JEF Make of Type TL06)
Supply of "Jef Ecosafe" Maintenance Free Earthing system comprising of 17.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding & 1 bag of Carbon based JEF Carbon Based environment friendly backfill and suitable clamp Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).
Supply of Model- DMD3-65MAG with potential free contact . Rating Iimp-12.5KA (L-N)& 50 KA (N-PE), Imax- 65 KA -3 Phase - Without Enclosure (Class I+ II)
SUBHEAD XXIX : SPECIAL EARTHING
Providing maintenance free Earth station with consisting of 40mm dia pipe standard length(as per equipment supplier)electrode capsule,filled with earth enhancing compound ,sealed at both ends and brazed lead for connection at one end.suitable for direct installation at side ,at a depth of 2.5mts.Earth enhancement compound up to a depth of 2mts around the electrode capsule ,brick chambers and CI cover complete.
Supply and Fixing of Static Discharge Handles made of Cu. Rod of 20mm dia 600mm Length fixed on wall with brass spacers and connected to Cu. earth strip
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
6 X 25mm Cu strip with SMC Single Pole Insulated Busbar Support. And Holes to be provided as per the direction of officer incharge
SUBHEAD XXX : FLAME PROOF FIXTURES
Supply, Installation, Testing and Comissioning of 50W Flame proof lighting with Cast aluminium housing with epoxy finish, Heat resistant. Saparate flame proof control gear box of suitable rating to be used for lamps. (Fortune Art, Model: FAFLPWG0250)
Supply, installation, testing and commissioning of 16A Single Phase 250V Grade FLP Socket with FLP Switch Fuse unit with HRC Fuses in FLP suitable size enclosures on angle iron frame work/ FLP Single Phase Sockets complete with all fixing accessories with suitable FLP cable chambers
Supply, fixing, Testing and Commissioning of factory made 63A, 3Ph Flame Proof Power Socket with all necessary fixing accessories.
Supply, fixing, Testing and Commissioning of factory made 100A, 3Ph Flame Proof Power Socket with all necessary fixing accessories.
Supply, Installation, Testing and commissioning of TPN/SPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB/ ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS: 8828 and ELCB /RCCB shall conform to IS : 12640
4Way TPN MCB LDB (Horizontal type Non flame Proof) with 40A, 4Pole MCB with as incomer and 12 nos 6-25A SPMCBs as outgoings (LDB&PDB).
6Way TPN MCB LDB (Horizontal type Non flame Proof) with 40A, 4Pole MCB with as incomer and 18 nos 6-25A SPMCBs as outgoings (LDB).
8Way TPN MCB LDB (Horizontal type Non flame Proof) with 63A, 4Pole MCB with as incomer and 24 nos 6-25A SPMCBs as outgoings (LDB).
Supply, laying, Testing and commissioning of following size 1.1KV grade XLPE insulated armoured Copper conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. The cable shall conform to IS 7098/Part I.
3Cx2.5 Sq.mm Cu.Ar. Cable (for Light Fixture's)
3Cx4.0 Sq.mm Cu.Ar. Cable (for 16A, 1-Ph Socket's)
4Cx10.0 Sq.mm Cu.Ar. Cable (for 63A, 3-Ph Socket's)
4Cx25.0 Sq.mm Cu.Ar. Cable (for 100A, 3-Ph Socket's)
Supply, Installation, Testing and commissioning of Providing end terminations for the cable specified below with compression type steel gland, Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc.,including end termination and Earthing of Gland.
3Cx2.5 Sq.mm Cu.Ar. Cable
3Cx4.0 Sq.mm Cu.Ar. Cable
4Cx10.0 Sq.mm Cu.Ar. Cable
4Cx25.0 Sq.mm Cu.Ar. Cable
Supply, laying, Testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/Part II.
4C X 16 Sq.mm
4C X 10 Sq.mm
Providing Indoor ordinary end terminations for the cable specified below with compression type steel gland, Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc.,including end termination and Earthing of Gland.
4C X 16 Sq.mm
4C X 10 Sq.mm
SUBHEAD XXXI : LAN/TELEPHONE
Supply and laying of 2 mm thick PVC conduit pipe of 25 mm dia for Laying of telephone cable.The pipe is to be supplied with required Junction boxes, bends etc complete.The pipe is to be laid in ceiling/on ceiling /in wall/ on wall with necessary base clamps etc complete.
Supply,Installation,Testing and commissioning of Telephone RJ 11 socket with flush mounting G.I. box, with front plate and fixing screws etc complete,
Supply and laying of 2 pair 0.5mm dia PVC insulated Copper conductor Telephone wire conforming to DOT specifications.
Supply and installation of 20 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement.
Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed.
Supply and laying of 2 mm thick PVC conduit pipe of 25 mm dia for Laying of Data cable.The pipe is to be supplied with required Junction boxes, bends etc complete.The pipe is to be laid in ceiling/on ceiling /in wall/ on wall with necessary base clamps etc complete.
Supply,Installation,Testing and commissioning of RJ-45 socket with flush mounting G.I. box, with front plate and fixing screws etc complete,
SUBHEAD XXXII : EXTERNAL ELECTRIC SUPPLY
HT Cable
Supply, laying, Testing and commissioning of following size 11KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/Part II.
3C X 240 Sq.mm
HT Cable Terminations
Providing weather proof end terminations for the cable specified below with compression type steel gland, Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc.,including end termination and Earthing of Gland.
3C X 240 Sq.mm (Outdoor)
3C X 240 Sq.mm (Indoor)
240Sq.mm Straight through Jointing Kit
HT Panel
Supply,erection,testing and comissioning of compact outdoor cubicle type 11kV HT Panel comprising of 1 No of 11kV, 26kA, 630A VCB with E/F,O/V,S/C releases.
Transformer
Supply and installation of approved make, 3 Phase, 50 C/s, Oils immersed and naturally cooled Out door type OCTC(Off Circuit tap change) Type copper wound transformer with delta connection on HV side and Star connection on LV side with additional neutral brought out on secondary side, Voltage rating 11/0.433kV with HV tapping of +/- 2.5% - 5% continuously rated for full load with standard accessories complete with test certificate with losses below 750 watts at no load,5800 watts at full load as per( IS : 2026 ) as per specifications.
11/0.433kV, 630kVA transformer
Bus Duct
Supply of the following Bus Duct with all nessary accorries including labour charges.
1200A, 50kA, 4Wire, Bus Duct (AIR INSULATED) sutiable for out door with Double earthing. Having 90 Deg Bend's, Flange Ends, tin coated copper flexible terminations, and all necessary accessories.
LT Kiosk
The switchboard shall be indoor construction, free standing, cubicle type modular construction, dust & vermin protected.The switchboard shall complies to latest edition of IEC 61439-1&2, Test certificate shall be issued by a reputed authority.The equipment shall be suitably constructed for safe, proper and reliable operation without undue wear, corrosion, heating or other operating trouble. Panel builder shall produce valid licensed agreement made with original manufacturer.The weatherproof housing shall be manufactured from Hot Galvanized Iron confirming to international specification and suitable for mounting on a flat concrete base or pier 300 mm above ground level. The enclosure frame shall be from OEM. The frame shall be of bolted design made of Galvanized iron with 9 fold structure for better rigidity and strength with 275GSM. No welding frame to be considered. All the load bearing members shall be made of GI sheet steel and it shall be of a totally enclosed design with cables entering from the Top/bottom and secured by cable cleats or glands and maintains equipotentiality of the switchgear.
The housing shall be arranged for front access/Rear access by means of hinged doors which shall be screwed to secure them. The rated impulse withstand voltage of the system shall be 8kV for ACB & MCCB feeders.The Electrical Panel shall have a rated short time withstand current of 50 kA for 1 second.The busbar will be designed for mounting on insulated supports that are sufficient in number to accept the flow of peak short circuit current upto 254kA. The switchboard Main distribution panel shall restrict the internal arcs faults within the compartment to ensure maximum safety to the operating personnel and also to minimize the downtime for replacement and repairs. Type test certificate shall be carried out to verify the arc containment within the compartment for 50kA, 0.3sec as per IEC 61641.
The Switchboard shall have Seismic withstand of Zone –IV. Even under extreme condition of short circuit or Mal-operation there will be no danger in the vicinity of the assembly.The switchboard shall be with Outer glass door with gasket to prevent from accidental / unauthorized operation of switchgears.The glass should be of minimum 4mm thick which should comply Mechanical impact of IK-09. The doors should be with pre-assembled handle (reversible) with 4 closing points must be used, double tongue standard type with locking system must be chosen. No hylam sheets to be used for segregation, GI sheet is preferable.
APFCR Panel
LT Cable
Supply, laying, Testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/Part II.
3.5C X 300 Sq.mm
(a) Laid in ground
(b) Laid in duct
3.5C X 240 Sq.mm
(a) Laid in ground
(b) Laid in duct
3.5C X 95 Sq.mm
(a) Laid in ground
(b) Laid in duct
4C X 10 Sq.mm
(a) Laid in ground
(b) Laid in duct
LT Cable Terminations
Providing Indoor ordinary end terminations for the cable specified below with compression type steel gland, Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc.,including end termination and Earthing of Gland.
3.5C X 300 Sq.mm
3.5C X 240 Sq.mm
3.5C X 95 Sq.mm
4C X 10 Sq.mm
Earthing
Providing maintenance free Earth station with consisting of 40mm dia pipe standard length(as per equipment supplier)electrode capsule,filled with earth enhancing compound ,sealed at both ends and brazed lead for connection at one end.suitable for direct installation at side ,at a depth of 2.5mts.Earth enhancement compound up to a depth of 2mts around the electrode capsule ,brick chambers and CI cover complete.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
32 X 5mm Aluminium strip with DMC Insulated Supports
50 X5mm GI strip laid in ground
SUBHEAD XXXIII : LIGHTING
Supply and erection of 65 Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 : 2 : 4 PCC Pedestal etc complete. The pole shall be with Junction box consisting of MCB, Terminal box. The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper cable. The Pole shall be fixed with 40W LED Light Fixture including supply of driver and fixing accessories etc complete..
Supply, laying, testing & commisioning of following size 1.1KVgrade XLPE insulated armoured aluminium conductor underground cable, including excavation of earth, providing protection with sand and bricks on top & sides and providing cable route markers at every 50m interval.
4Core 6sq.mm
Providing End terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductor cable with compression type steel gland, alluminum lugs using crimping tool, Insulation tape, Identification tags etc., including end termination.
4Core 6 sq.mm
Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.
Supply and laying of following dia NP 2 grade RCC hume pipes with collars for road crossings,laid 750 mm below ground level including excavation , backfilling and other civil engineering works.
150 mm dia.
Street Light Panel
SUBHEAD XXXIV : FIRE ALARM SYSTEM
Supply,Testing and commissioning of the following number of Loops Microprocessor based addressable type (EN / UL approved) Fire alarm control panel with Zonal Indications, supervised inputs, supervised and non-supervised outputs,Zener barriers, two way media converter / Signal booster for in / out network connectivity with OF cableand with battery Power pack as per specifications.
a) 2 - Loop
Supply installation, testing and commissioning of analog addressable type multi sensor (smoke / heat) photo electric detectors with base and LED indication lamp along with all fixing accessories.
Supply installation, testing and commissioning of reponse indicators with LED indication lamp along with all fixing accessories.
Supply, Installation, Testing and commissioning of anologue addressable loop sounders along with all fixing accessories.
Supply, Installation, Testing and commissioning of fault isolators along with all fixing accessories.
Supply,Installation,Testing and commissioning of anologue addressable type monitor module along with all fixing accessories.
Supply,Installation,Testing and commissioning of addressable control module along with all fixing accessories.
Supply, Installation,Testing and commissioning of anologue addressable ordinary Manual call point with push type along with all fixing accessories.
Supply and laying of 25mm dia medium class FRLS PVC conduit concealed in wall /ceiling / above false ceiling including bends,elbows, junction boxes, saddles, spacers etc., and other material required for fixing complete as per requirement.
Supply,laying,testing of twisted pair 1.5sq mm shielded FR insulated copper conductor flexible wire in existing PVC conduit.
Supply, fixing and installation of fire exit signage's self illuminating light fixtures displaying exit with an arrow towards the exit door.
Supply and installation of 2.5 KM range siren with weatherproof motor with 220V 50 Hz AC Supply operation with required power contactor, MPCB for control all in a weatherproof enclosure near motor including all installation materials as required for completion of work.
Supply and laying of 3 core 2.5 sq mm copper conductor PVC insulated armoured cable including all fixing accessories for connectivity of the siren with all required fixing accessories etc., complete
Supply, installation, testing and commissioning of 8 way Wago/ Phoenix terminal connector in weatherproof MS junction box including painting and all installation materials etc complete as required
Supply, installation, testing and commissioning of weather proof analogue addressable break glass type manual call point with 1500mm long 50X50X6 channel fixed on ground with PCC coping with all required accessories etc., complete.
Supply, installation, testing and commissioning of Single ended reflector type addressable Beam smoke detector with all required accessories etc., complete.
QUICK BUILDERS
TRINETRA CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Elec_Tech_Specs_3.pdf
Additional Documents • 0.32 MB
ELEVATION.pdf
Additional Documents • 0.26 MB
Civil_Tech_Specs.pdf
Additional Documents • 0.36 MB
PLAN.pdf
Additional Documents • 0.34 MB
ROOF_PLAN.pdf
Additional Documents • 0.27 MB
BOQ_559654.xls
BOQ • 0.96 MB
Elec_Tech_Specs_1.pdf
Additional Documents • 0.56 MB
Elec_Tech_Specs_2.pdf
Additional Documents • 0.96 MB
SECTION.pdf
Additional Documents • 0.36 MB
SUB_STATION.pdf
Additional Documents • 0.24 MB
Annexure_I_NIT.pdf
Additional Documents • 0.24 MB
Tender_Enquiry.pdf
Tender Documents • 0.57 MB
Approved_Makes.pdf
Additional Documents • 0.33 MB
Download all tender documents and submit your bid