| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹27.2 L Quoted ₹27.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹30.9 LRejected-AOC 303 GHS 88 SECTOR 20 PANCHKULA 134113 HARYANA | PANCHKULA | HARYANA | 134113 | ₹30.9 L | L2 | Rejected-AOC Not being L1 |
| 3 | L3₹31.6 LRejected-AOC | ₹31.6 L | L3 | Rejected-AOC Not being L1 |
| 4 | L4₹32.6 LRejected-AOC | ₹32.6 L | L4 | Rejected-AOC Not being L1 |
| 5 | L5₹33.9 LRejected-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹33.9 L | L5 | Rejected-AOC Not being L1 |
| Sl No | Description | Qty | Unit | Raman Electric Trading Co L5 | BHARAT ENGINEERS L3 | R D Bansal L2 | Bharat Builder L4 | kailu construction co L1 | UNITED ENGINEERING CORPORATION L7 | KHAJURIA ENGINEERS L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply,laying & testing of HT underground cable XLPE insulated PVC bedded, screened,galvanised steel flat strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts Earthed, grade cross sectional area 95 sqmm 3 core, laid in duct / trench/along pole etc including making connection complete all as specified and directed.
Note : HT cable test certificate produced by contractor & NABL Lab. test report also produced by Contractor without any extra cost. Exavation, Returning filing, Removal, Steel tubing, sand cushioning and cable cover will be measured and paid separately. | 2,200 | RM | 1,050 ₹23.1 L | 1,000 ₹22 L | 1,039 ₹22.9 L | 995 ₹21.9 L | 830 ₹18.3 L | 1,035 ₹22.8 L | 1,020 ₹22.4 L |
| 2.00 | Material and labour for Pre stressed concerete pole 11 m long of cross section of 152mm x 152mm at top and 152mm x 260 mm at bottom class 09 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic paint in black & white strip of 30cm width upto 1.5 mtr high from coping over a coat of primer including numbering of poles complete all as specified and directed.
Note:- Exavation and foundation will be paid and measure separately. | 12 | EACH | 12,500 ₹1.5 L | 7,500 ₹90,000 | 8,500 ₹1.0 L | 6,500 ₹78,000 | 9,300 ₹1.1 L | 26,500 ₹3.2 L | 7,500 ₹90,000 |
| 3.00 | Supply and fixing of HT End termination joint heat shrink type joint, Indoor/outdoor type suitable for 3 core 11000 volts grade XLPE UG cable of size 95 Sq mm complete all as specified and directed. | 16 | EACH | 2,200 ₹35,200 | 2,000 ₹32,000 | 1,500 ₹24,000 | 4,000 ₹64,000 | 2,300 ₹36,800 | 6,000 ₹96,000 | 3,000 ₹48,000 |
| 4.00 | Material and labour for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface complete all as specified and directed. | 1 | CUM | 2,500 ₹2,500 | 2,800 ₹2,800 | 2,000 ₹2,000 | 3,500 ₹3,500 | 1,500 ₹1,500 | 3,125 ₹3,125 | 4,500 ₹4,500 |
| 5.00 | Material and labour for PCC 1:3:6 type C-1 using 20mm graded broken stone aggregate as in columns, piers, stays and poles etc.complete all as specified and directed. | 6.5 | CUM | 1,700 ₹11,050 | 2,500 ₹16,250 | 2,000 ₹13,000 | 3,500 ₹22,750 | 1,000 ₹6,500 | 3,450 ₹22,425 | 4,500 ₹29,250 |
| 6.00 | Material and labour for PCC 1:3:6 type C-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as specified and directed. | 1 | CUM | 1,700 ₹1,700 | 2,400 ₹2,400 | 2,000 ₹2,000 | 3,500 ₹3,500 | 1,500 ₹1,500 | 3,850 ₹3,850 | 4,500 ₹4,500 |
| 7.00 | Material and labour for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specified and directed. | 5 | QUINTAL | 8,000 ₹40,000 | 8,500 ₹42,500 | 6,700 ₹33,500 | 10,000 ₹50,000 | 8,800 ₹44,000 | 9,900 ₹49,500 | 12,000 ₹60,000 |
| 8.00 | Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion.
Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted & including taking down/dismantling of existing earthing pits. | 28 | EACH SET | 3,300 ₹92,400 | 4,000 ₹1.1 L | 3,000 ₹84,000 | 3,000 ₹84,000 | 3,800 ₹1.1 L | 4,000 ₹1.1 L | 4,200 ₹1.2 L |
| 9.00 | Supply and fixing out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch (GOD + DO), mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 200 amps and all accessories ie pipe clamp etc complete all as specified and directed. | 10 | EACH | 18,000 ₹1.8 L | 13,000 ₹1.3 L | 12,550 ₹1.3 L | 14,500 ₹1.4 L | 13,800 ₹1.4 L | 17,500 ₹1.8 L | 19,500 ₹1.9 L |
| 10.00 | Supply and fixing out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch (GOD + DO), mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 400 amps and all accessories ie pipe clamp etccomplete all as specified and directed. | 4 | EACH | 18,500 ₹74,000 | 13,500 ₹54,000 | 13,450 ₹53,800 | 16,000 ₹64,000 | 13,800 ₹55,200 | 19,500 ₹78,000 | 19,500 ₹78,000 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
12 Dec 2025, 6:00 pmClosed
CWE Amritsar
HQ CWE Amritsar
SPL REPAIR REPLACEMENT OF OH HT CONDUCTOR TO UG HT XLPE CABLES WITH CONNECTED WORKS AT ARMD BDE FEEDER AT NAMS
2025_MES_741016_1
83073/E8
Open Tender
Civil Works
180 days
GE NAMS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAMS
₹95,000
Yes
5 Feb 2026
21 Nov 2025
19 Dec 2025
21 Nov 2025
12 Dec 2025
5 Dec 2025
Amount
Supply,laying & testing of HT underground cable XLPE insulated PVC bedded, screened,galvanised steel flat strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts Earthed, grade cross sectional area 95 sqmm 3 core, laid in duct / trench/along pole etc including making connection complete all as specified and directed. Note : HT cable test certificate produced by contractor & NABL Lab. test report also produced by Contractor without any extra cost. Exavation, Returning filing, Removal, Steel tubing, sand cushioning and cable cover will be measured and paid separately.
Material and labour for Pre stressed concerete pole 11 m long of cross section of 152mm x 152mm at top and 152mm x 260 mm at bottom class 09 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic paint in black & white strip of 30cm width upto 1.5 mtr high from coping over a coat of primer including numbering of poles complete all as specified and directed. Note:- Exavation and foundation will be paid and measure separately.
Supply and fixing of HT End termination joint heat shrink type joint, Indoor/outdoor type suitable for 3 core 11000 volts grade XLPE UG cable of size 95 Sq mm complete all as specified and directed.
Material and labour for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-1 using 20mm graded broken stone aggregate as in columns, piers, stays and poles etc.complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as specified and directed.
Material and labour for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted & including taking down/dismantling of existing earthing pits.
Supply and fixing out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch (GOD + DO), mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 200 amps and all accessories ie pipe clamp etc complete all as specified and directed.
Supply and fixing out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch (GOD + DO), mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 400 amps and all accessories ie pipe clamp etccomplete all as specified and directed.
Excavation in trenches n .exc 1.5 m wide and not exec 1.5 m in depth for foundation etc or for laying pipe lines and cables and getting out as in looses/soft soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and laying in replacement for un-reinforced precast concrete cable cover factory made, class HV, type I, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Material and labour for Sand cushioning to underground cable 8cm before laying the cable and 15cm after laying punned down to 18 cm and stretching the cable complete all as specified and directed. Note:- Punned down thickness shall be used for measurement.
Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall etc.for protection of Cable / GI wire / GI strip etc complete all as specified and directed.
Supply and fixing pin type polymer type insulators including galvanised mild steel spindle, two galvanised iron washers, and one galvanised iron nuts, 150mm height 150 mm dia including section of straps of 38x5mm size 20mm dia of bolts, nuts & washers for 11000 volts grade, complete all as specified and directed.
Material and labour for cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.60m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x 20cm x 30cm block complete all as specified and directed.
Material and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white , with numeric, letters in Hindi ,English and including local language and conventional skull and bones in signal red and fixed with MS Clamps , bolts and nuts of approved size (25x20cm) for EHV for 11000 Volt ,of suitable size complete all as specified and directed.
Material and labour for replacement of HT lightening arrestor for outdoor use, expulsion type, POLYMER complete with all fittings, transmission class, discharge capacity 65kilo amps, minimum working pressure 11000volts grade conforming to IS complete all as specified and directed.
R D Bansal (BID ID -3496267)
BHARAT ENGINEERS (BID ID -3496264)
Bharat Builder (BID ID -3496285)
Raman Electric Trading Co (BID ID -3496001)
KHAJURIA ENGINEERS (BID ID -3496519)
UNITED ENGINEERING CORPORATION (BID ID -3496485)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_829757.xls
BOQ • 0.29 MB
83073Tender.pdf
Tender Documents • 0.99 MB
Download all tender documents and submit your bid