Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹31.3 L+₹3.3 L (11.9%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹34.0 L
EMD Value
₹67,900
Closing Date
19 Feb 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
MAINTOFWATER SPLY SYS INCL REP TO PUMP SET MOTOR CONTROL PANELSTARTER PUMPING MAINS DI GI CI PIPES VALVES PAINTING ETC AND MAINT RENEWAL AND REP OF INTL ACCS SUBMAIN WIRING FANGEYSER ETC OF CERTAIN MD OTM ACCN AT DUNKIRK LINE UNDER AGEEMI IN GE CKKE
2021_MES_414975_1
8442/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹67,900
Yes
22 Mar 2021
22 Jan 2021
20 Feb 2021
22 Jan 2021
19 Feb 2021
5 Feb 2021
22 Jan 2021 - 4 Feb 2021
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for lying of pipes etc and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for lying of pipes etc and getting out in road cuttings/Hard dense soil complete all as specified and directed.
Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers n . Exc 25 cm complete all as specified and directed.
M & L forTaking up cast iron water mains (incl all fitting) 80mm bore dia of pipe with spigot and socket ends from trenches complete all as psecified and directed.
All as item no.5 above but 100 mm bore pipes.
All as item no.5 above but 150 mm bore pipes.
All as item no.5 above but 200 mm bore pipes.
M & L for Cutting cast iron pipes in position for insertion of fittings, mechanical joints etc for bore of pipe 80mm (each cut shall be measured )
All as item no.9 above but 100 mm bore pipes.
All as item no.9 above but 150 mm bore pipes.
All as item no.9 above but 200 mm bore pipes.
M & L for Laying only 80 mm bore CI pipes with spigot and socket ends laid in trenches including thorough cleaning of old CI pipe by descaling internally with steel brushes equal to bore of pipe, scraping washing properly complete all as specified and directed. ( serviceable pipes received from item No 5).
All as item no.13 above but 100 mm bore pipes.( serviceable pipes received against item no.6)
All as item no.13 above but 150 mm bore pipes.( serviceable pipes received against item no.7)
All as item no.13 above but 200 mm bore pipes.( serviceable pipes received against item no.8)
M & L for Ductile iron fittings such as bends (any type, radius and angle), tapers any type (straight, bend, incresing, decreasing or double socket etc.), Tee piece, single branch 'Y'junction double branch, collar etc., caps and plugs etc. as per IS: 9523-2000 of class K-7, with internal cement mortor lining, and external zinc and black bitumen coated of dia upto 200 mm complete all as specified and directed
M&L for laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wall/ on floor locations for 80 mm bore dia pipe complete all as specified and directed. Make: Electro steel/Electro cast.
All as item no. 19 above but 100 mm bore pipes.
All as item no. 19 above but 150 mm bore pipes.
All as item no. 19 above but 200 mm bore pipes.
M&L for taking up worn out GI steel tubing incl all fitings fron trenches of 15 mm bore complete all as specified and directed.
All as item no.22 above but 20 mm bore pipes.
All as item no.22 above but 25 mm bore pipes.
All as item no.22 above but 40 mm to 50 mm bore pipes.
All as item no.22 above but 80 mm bore pipes.
All as item no.22 above but 100 mm bore pipes.
All as item no.22 above but 150 mm bore pipes.
M & L for Laying only GI pipes of size 20 mm bore in trenches including thorough cleaning and descaling internally complete all as specified and directed. ( serviceable pipes received against item No-23).
All as item no.29 above but 25 mm bore pipes (servicable pipes received against item no.24 )
All as item no.29 above but 40 mm bore pipes (servicable pipes received against item no.25 )
All as item no.29 above but 50 mm bore pipes (servicable pipes received against item no.25 )
All as item no.29 above but 80 mm bore pipes (servicable pipes received against item no.26 )
All as item no.29 above but 100 mm bore pipes (servicable pipes received against item no.27 )
All as item no.29 above but 150 mm bore pipes (servicable pipes received against item no.28 )
M&L for Laying in trenches/fixed to wall galvanised steel water tubing 15 mm bore, medium grade with and including all medium grade fittings complete all as specified.Make: Tata/Jindal
All as item no.36 above but 20 mm bore pipe.
All as item no.36 above but 25 mm bore pipe.
All as item no.36 above but 40 mm bore pipe.
All as item no.36 above but 50 mm bore pipe.
All as item no.36 above but 80 mm bore pipe.
All as item no.36 above but 100 mm bore pipe.
All as item no.36 above but 150 mm bore pipe.
M&L for taking appart and reassembling stuffing box of sluice valve S.S. Spindle of size 80 mm to 200 mm in position for any type of sluice valve and replacement of gland packing. Note: (i) Nuts, bolts & washers whenever require new shall be measured and paid separately as supply only.
S&F in repairs CI body non raising spindle sluice valve with cast iron wheel, of size 80 mm bore, class PN-1.6 with SS spindle with brass nut, both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc complete in position of pipe line all as specified and directed. Make Kirloskar,Bir,Upadhyaya,BVI. Note: (i) Nuts, bolts & washers wherever required new shall be measured and paid under respective item. (ii) Rubber gasket shall be inclusive of the quoted rate of this item.
All as item no.45 above but 100 mm bore
All as item no.45 above but 150 mm bore
All as item no.45 above but 200 mm bore
M & L for dismentling & taking out carefully sluice valve head with gate, spindle and stuffing box of size 80 mm to 200 mm bore in position, replacement of worn out SS/GM spindle & GM nut with new SS/GM spindle or GM nut for sluice valve class PN 1.0, and refixing gate, spindle, nut, valve head with stuffing box incl necessary PTFE gland packing, nuts, bolts, washers, gland bolts, rubbers gaskets etc complete all as specified and as directed. Note: (i) SS/GM spindle, GM nuts shall be measured and paid separately as supply only. (ii) Nuts, bolts & washers whenever require new shall be measured and paid under respective item. (iii) PTFE gland packing and Rubber gasket shall be inclusive of the quoted rate of this item.
M &L For GM/ SS spindle for sluice valve class PN 1.6/ 1.0, 80 mm bore
M & L for GM / S S spindle for sluice valve class PN1.6/ 1.0, 100 mm bore
M L for GM / S S spindle for sluice valve class PN 1.6/ 1.0, 150 mm bore
M & L for GM / S S spindle for sluice valve class PN 1.6/ 1.0, 200 mm bore
M & L GM/ S S nut suitably threaded internally as per spindle thread and to the size of wedge of valve gate for sluice valve 80 mm bore class PN 1.6/ 1.0 complete all as directed.
All as item no.54 above but 100 mm sluice valve.
All as item no.54 above but 150 mm sluice valve.
All as item no.54 above but 200 mm sluice valve.
S&F in repair gun metal gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore complete all as specified and directed. Make: Zoloto or equivqlant.
All as item no.58 above but 20 mm bore.
All as item no.58 above but 25 mm bore.
All as item no.58 above but 40 mm bore.
All as item no.58 above but 50 mm bore.
Supply & fixing in repairs cast Iron swing check non return valve confirming to IS : 5312 (Part I) of 1969, both end flanged with rubber gasket & Nuts, bolts & washersof sizes 80 mm bore. (Note:- Nuts, bolts & washers wherever required new shall be measured and paid in respective item )
Supply & fixing in repairs cast Iron foot valve confirming to IS : 4038 flanged end with rubber gasket, Nuts, bolts & washers of sizes 80 mm bore. (Note:- Nuts, bolts & washers wherever required new shall be measured and paid in respective item )
Supply only Mild steel screw bolts (machine made) with hexagonal heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal nut, n exc 10 cm long , 10 to 20 mm dia of neck.
M&L for MS mechanical joint with rubber washer, mild steel screw bolts (machine made) with screwed both ends of dia as per flange hole and required length each screwed end to be fitted with washers and one hexagonal nut suitable for bore of pipe 80mm complete all as specified.
All as item no.66 above but for 100 mm bore pipes.
All as item no.66 above but for 150 mm bore pipes.
All as item no.66 above but for 200 mm bore pipes.
M&L for M & L for PCC (1:3:6) type C1 block masonry over 10 cm in width built in cement mortar (1:6) complete all as specified incl Demolition of unsv precast concrete block walling built in cement morter all as specified and directed.
M&L for cement plaster 10mm thick in CM1:4 on fair faces of brick work or concrete surfaces finished even and fair incl taking down plaster any description, racking out joints, hacking for key, scrubbing down with water complete all as specified.
M&L for PCC 1:3:6 type-C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete incl necessary form work werever required and incl demolition of Cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, all as specified and directed at site.
M&L for mild steel framed work with ends of bars souldered, welded or reveted or forced into spikes, framed guard bars, ladders, framed balusters, walk ways, railings, gates, frame work of water tank, valvepit and similar work confirming to Fe.290.Gde-E-165 incl painting with one coat of red oxide primer and one coats of anticorrosive black bituminous paint incl dismantling mild steel work of any description not otherwise specially provided for all as specified and directed.
M&L for one coat of synthetic enamel paint to old steel surfaces of any description, incl preparation of surfaces, for area over 10cm in width or girth,not otherwise described as per specified colour code all as specified and directed.
M&L for preparation of plastered or unplastered surfaces of wall and applying one coat of cement based paint of approved tint complete all as specified and directed.
M&L for preparation of plastered or unplastered surfaces of wall and applying two coats of cement based paint of approved tint complete all as specified and directed.
M&L for preparation of plastered or unplastered surfaces of wall and applying one coat of dry distemper of approved tint complete all as specified and directed.
Supply and fix Hot Dipped Galvanized Chain Link Fencing with Zinc Coating, nominal height-2400mm, Pitch-50mm and wire dia 3.15 mm. (approx weight-2.55 Kg /Sqm) including taking out defective fencing any type and size.
M&L for mild steel work of angle fixed independently for fencing post and others confirming to Gde Fe 410-A incl cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts incl dismentling taking down unsv one complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securingwith clips complete for support of chain link fencing incl dismentling taking down unsv one all as specified and directed.
M&L Cement concrete type B-2,1:2;4 ( 40 mm graded stone aggregate ) in sub base 75 mm thick
S&F in repair 80 mm thick machine pressed precast concrete rubber moulded coloured interlocking paver block with coloured cement and pigment any shape and size confirming to IS-15658-2006 M-40 grade laid over 50 mm thick sand cushionining all as directed including surface excavation up to 30 cm depth and levelling etc complete.
Dismantling taking out complete pump of any type, capacity 25 HP to 30 HP from foundation including dismentling suction and delivery pipe connection from pump , carrying to wksp & back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete including testing, commissioning all as specified and directed.
Ball Bearing, (DE).
Ball Bearing (NDE).
Impeller.
Pump Shaft.
Lantern Ring.
Mechanical Seal.
Water Deflector.
Sleeve.
Key Impeller.
Gland Packing.
Dismantling taking out complete pump of any type, capacity 5 HP to 10 HP of different models from foundation including dismentling suction and delivery pipe connection from pump , carrying to wksp & back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete including testing, commissioning all as specified and directed.
Ball Bearing, (DE).
Ball Bearing (NDE).
Impeller.
Pump Shaft.
Lantern Ring.
Mechanical Seal.
Water Deflector.
Sleeve.
Key Impeller.
Gland Packing.
Dismantling taking out Induction motor 25 Hp to 30 Hp from foundation by removing electric connection, coupling carefully and carrying to wksp & back for repair complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning, proper alignment all as specified and directed.
Dismantling taking out Induction motor 5 Hp to 10 Hp from foundation by removing electric connection, coupling carefully and carrying to wksp & back for repair complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning, proper alignment all as specified and directed.
M&L for complete rewinding of motor any type after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in the slots, rewinding with existing size of super enamelled coper wire, required binding, bonding, insulation, varnishing and drying and proper testing after rewinding for motor capacity 25 HP to 30 HP
M&L for complete rewinding of motor any type after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in the slots, rewinding with existing size of super enamelled coper wire, required binding, bonding, insulation, varnishing and drying and proper testing after rewinding for the following sizes of motor capacity 5 HP to 10 HP
Repair/maintenance/overhauling in situ of Pump starter panel of capacity from 5 HP to 30 HP by dismantling taking out old damaged panel wiring, replacement of Contactor, relays, Timer, Push buttion, single phase preventor, voltmeter, ammeter, LED indicator and other miscellenious items as required and testing complete after completion of work. Note: spares required for the starter panel is measured and paid under respective item.
M&L for AC Contactor, 3 pole, 3 ph, 415V, AC, 50Hz, Type- ML-2 to ML-5 , Make- L&T, or equivelent of equivelent of Schneider/ABB/C&S
M&L for AC side mounting add on aux contact block for contactor Make- L&T, or equivelent of Schneider/ABB/C&S
M&L for AC front add on aux contact block Make- L&T, or equivelent of Schneider/ABB/C&S
M&L for Thermal overload relays, relay range 9 amp to 15 amps as applicable, Make-L&T or equivelent of Schneider/ABB/Crompton/C&S
M&L for Electronic Timer, 3 - 30 Sec 415V Make- L&T, or equivelent of Schneider/C&S/Minilac
M&L for Motor protection relay, O/L range 1.2 amps, Make-L&T or equivelent of Schneider/ABB/Crompton/C&S
M&L for Single phase preventor relay, Make- L&T or equivelent of Schneider/ABB/C&S /Minilac
M&L for LED indication Lamps as per existing size R-Y-B
M&L for Starter Push button Red/green as per existing size.
Fabrication ,supply,install Installation boards( Sign Boards ) of size 3.50 met X1.00X0.50 met with angle iron frame duly welded of size30X30X3.00 mm thick pasted with flex board duly printed letters in white colour on dark blue background pre wired with LED Lighting,connecting cable weather proof 4.00 sq mm 2 core from switch board including taking out perished sign boards as per samples at Pump House all as directed.
Chemical testing of water sample at 3 month interval at PMC or at any govt recognised water testing lab for the following parameters: Turbidity, pH, Total Hardness, Alkalinity, Chloride, Nitrate, TDS, Iron, Flourides, calcium, Magnesium, Aluminium, Sulphide, Lead, Arsenic, Manganese, Copper, Mercury, residual chlorine. (Note: (i) Sample of water to be collected from each pump house at Dunkirk Line in sterilised bottle provided by the lab (ii) Sample of water to be deposited to lab and report to be collected duly signed by authorised person of Lab, (iii) Cost of transportation of water sample and collection of report shall be inclusive of quoted rate, (iv) Cost of Testing as specified shall be paid to Lab directly by the Contractor and the cost shall be inclusive of quoted rate, (v) Test shall be carried out in scheduled time, otherwise recovery shall be effected thrice the quoted rate, (vi) Complete parameter testing shall be considered as one job)
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSHCopper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith two single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth leads and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Four run of cable with two run of earth wire and one run of casing capping/conduit will be measured as one length.
S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed.
S&F 5 Amp switch piano type two way incl dismentling taking down unsv one all as specified and as directed.
S&F bell push piano type one way 240 volt incl dismentling taking down unsv one . all as specified and as directed.
S&F socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1, 5 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1,3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed.
S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed.
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL.
S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one all as specified and as directed.
S&F call bell electric, ding dong, AC 240 volt, 50 HZ. incl dismentling taking down unsv one all as specified and as directed.
S&F flush type electronic fan regulator with 5 step type,100 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed.
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed.
S&F MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed.
S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed.
S&F Sheet metal enclosure two way, incl dismentling taking down unsv one all as specified and directed.
S&F MCB distribution board,Double door, metal enclosure, SPN, 230 Volts, 4 way incl dismentling taking down unsv one all as specified and directed.
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed.
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way incl dismentling taking down unsv one all as specified and directed.
S&F MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed.
S&F Vertical MCB distribution board, as MCB incomer, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed.
S&F Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed.
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismentling taking down unsv one all as specified and directed.
S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed.
S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed.
S&F PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed.
S&F PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed.
S&F Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismentling taking down unsv one
S&F Round shaped surface/ recess mounted LED Flat panel,PDC Aluminium housing and PMMA difuser 12 watt suitable for surface/ POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed.
S&F square shaped surface/ recess mounted LED Flat panel,PDC Aluminium housing and PMMA difuser 12 watt suitable for surface/ POP celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed.
S&F Square shaped recess mounted LED slim Flat panel suitable for fixing in aluminium framed ceilling, 36 watt, 2'x2'size, complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type all as specified and directed.
S&F LED tube 20 watt retro LED T8 ( PC ) to existing fluorescent FTL fitting surface mounted after dismentling electronic ballast, internal wiring and complete rewiring with 0.5 sqmm copper flexible conductor FRLSHom connector block to one end of Bipi holder and including connecting up to ceiling rose with 0.5 sqmm two core flexible copper conductor cable all as specified and directed.
S&F LED batten tube type, 2'long, 09 watt,CDL 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed.
S&F LED Tube light fitting, 36 watt, CDL, integrated LED batten, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed.
S&F LED Tube light fitting, 18 watt, CDL, durable LED batten with decorative end caps, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed.
S&F LED building security light 25 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 25/32 mm dia bracket of total length 60 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK :- M&L for Rewinding of Ceiling fan 1200 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor will collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & Fixing only. 3. Cost of Connector bock and capacitor holder shall be inclusive of the quoted rate.
All as per item No- 45 here-in-above but for Exhaust fan 250/300 mm sweep industrial type.
All as per item No- 45 here-in-above but for Exhaust fan 450 mm sweep industrial type.
All as per item No- 45 here-in-above but for Air circulator fan 450 mm sweep.
S&F ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC.
S&F G.M. Bush bearing for ceiling fan as per existing pattern.
S&F capacitor AC for 230 volts 50 Hz of capacity 1.8 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd.
Painting of ceiling fan 1200/1400 mm including scrapping, cleaning and removing dust from the blade an body and applying two coat of enamel paint over & one coat of primer all as directed by engr-in-chage
S& F in repair of exhaust fan225 mm PVC body with louvres, 230 volt incl dismentling taking down unsv fan any type all as specified and directed.
S& F in repair of exhaust fan 300 mm PVC body, 230 vol incl dismentling taking down unsv fitting any type all as specified and directed.
S&F PVC insulated PVC sheathed copper flexiable wire multistrand 4sqmm 3 core, ISI marked
S&F in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity.
S&F in repair fusible plug marked suitable for 25 and 50 ltrs capacity Geysers all as specified and directed.
S&F in repair heating elementMarked round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and directed.
S&F in repair innner water container made of SS, vertical or horizontal type for 25/50 ltr capacity gyser all as specified and directed.
S&F in repair of aparatus plate suitable for vertical/horizintal type Geyser 25 or 50 ltr cap all as specified and directed.
S&F in repair heavy duty copper connections pipe with brass hexagonal adopters at both side 15mm dia and 450mm long for hot water all as specified and directed.
S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water all as specified and directed.
Serving/Repair and maintenance of solar water heator 100/200 ltrs capacity including flushing out solar tank and pipes with chemicals installed at roof top of bldg up to 15 met height
S&F in repair EDPM hose pipe including kit suitable for 100/200 Ltrs solar water heator
S&F in repair solar water heator element 3.00 Kw round base as per existing size and shape for 100/200 Ltrs solar water heator
S&F in repair Pvc flexible copper conductor cable multi stranded of size 6.00 sq mm for 100/200 Ltrs solar water heator
S&F in repair Thermostat 40 -100 degree range as per existing size and shape for 100/200 Ltrs solar water heator
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 6 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 6.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised earthing lead of 4 mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with pit cover, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI earthing lead 4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
SKS Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .