REPAIR AND MAINT TO STREET LIGHT, SECURITY LIGHTS, PERIMETER LIGHTING, FLOOD LIGHTS, HIGH MAST LIGHT AT MIL STN SGNR
2026_MES_774452_1
GE SGNR/TOK-14 OF 2026-27
Open Tender
Electrical and Maintenance Works
270 days
Sri Ganganagar (Raj.)
E Class b(i) and for un-enlisted, refer NIT para 8.
7 documents required · 7 mandatory
₹500
GE Sri Ganganagar
₹36,000
Yes
24 Jun 2026
24 Jun 2026
17 Jul 2026
24 Jun 2026
15 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down existing unserviceable security / street light of any size & capacity from existing pole/building/wall for checking & replacement of unserviceable parts including checking of electric circuit complete all as specified & directed by Engineer in charge and refixing the same.
Note : (i) The contractor's or his authorised rep/supervisor will receive complaint on each working day from JE E/M & will rectify the total no of complaints given to him on the same day & feedback to JE E/M daily evening.
(ii) Penel recovery @ Rs 20 per / light complaint not rectified within 08 hrs will be recovered.
(iii) The contractor will deploy one electrician (ITI Pass with minimum 3 years experience and one helper daily to attend the compalints. They will report at 0830 hrs daily to JE/Engineer-in-Charge.
(iv) The contractor will ensure all safety measures of the workers incluiding insurance.
(v) Necessarty tools & T&P required to rectify complaints will be provided to the labour employed by the contractor without anty extra cost to the Govt.
(vi) Parts required for replacemwnt shall be measured as "Supply only" and paid seperately under respective items of BoQ. | 140 | Each Job | - | - |
| 2 | Supply only LED plate module capacity 40 to 50 watt and support to existing light with 01 years replacement warranty complete all specified and directed. | 20 | Each | - | - |
| 3 | Supply only LED plate module capacity 60 to 75 watt and support to existing light with 01 years replacement warranty complete all specified and directed. | 20 | Each | - | - |
| 4 | Supply only LED plate module capacity 120 to 180 watt and support to existing light with 01 years replacement warranty complete all specified and directed. | 20 | Each | - | - |
| 5 | Supply only LED street light driver capacity 40 to 50 watt and support to existing light with 01 years replacement warranty complete all specified and directed. | 30 | Each | - | - |
| 6 | Supply only LED street light driver capacity 60 to 75 watt and support to existing light with 01 years replacement warranty complete all specified and directed. | 30 | Each | - | - |
| 7 | Supply only LED street light driver capacity 120 to 180 watt and support to existing light a with 01 years replacement warranty complete all specified and directed. | 20 | Each | - | - |
| 8 | S & F in replacement, new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP67 rodway luminaire 60 watt with heat resistant clear toughened glass, better optics for uniform distribution street/ Rodway luminair, with driver complete fitting with all accesoories and following specifications complete complete all as specified and directed by Engineer-in-Charge. (Note : (a) Lumen system efficiency of luminaire should be minimum 120 lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp Operating range : Minus 10°C to Plus 50°C (d) Power Fector : Minimum 0.95 (e) THD : Max 10% (f) IP rating : Minimum IP 66 (g) IK rating minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens (o) BIS Approved fixtures and driver (p) Rated life time : 50000 buring hrs @L70 (Average 10 to 12 hrs daily), Bracket for fixing and cable for connection shall be measured and paid separately and existing light make to serviceable with 01 years replacement warranty complete all specified and directed. | 75 | Each | - | - |
| 9 | Supply and fixing in replacement new generation energy saving and environmental friendly long life versatile pressure die-cast aluminum IP-66 roadway luminair 72 watt with heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessoreis and followig specifications complete all as specified and directed.
(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt.
(b) Input voltage range : 140 to 270 volts
(c) Temp operating range : Minus 10°C to Plus 50°C
(d) Power factor : Minimum 0.95 (e) TDH : Max 10%
(f) IP rating : Minimum IP 66
(g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 KV (inbuilt + extended) (I) CCT : 5700K.
(m) CRI : Morethan 70 (n) Lens - High efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @ L70 (Average 10 to 12 hrs daily)
Note : Bracket for fixing and cable for connection shall be measured and paid separately. | 75 | Each | - | - |
| 10 | S & F in replacement energy saving & environmental friendly long life versatile pressure die cast aluminium IP66 LED fiood light cool/warm with high power LEDs as light source roadway luminaire 120 watt with heat resistant clear toughened glass,better optics for uniform distribution with driver complete fitting with all accessories and following specifications, complete all as specified and as directed :-
(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended)
(l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Note :- Bracket for fixing and cable for connection shall be measured and paid separately. | 10 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
GenPage1.pdf
Tender Documents • 1.04 MB
GenPage2.pdf
Additional Documents • 0.63 MB
BOQ_867199.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid