Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L1 | Accepted-AOC Being a lowest bidder and reasonable. | |
| 2 | L2₹50.4 L+₹8.3 L (19.8%)Rejected-Finance 121004 | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹50.9 L+₹8.8 L (21.0%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹52.1 L+₹10.1 L (23.9%)Rejected-Finance 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L4 | Rejected-Finance Other than lowest. | |
| 5 | L5₹55.8 L+₹13.7 L (32.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
24 Sept 2024, 6:00 pmClosed
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/MAINT OF DG SETS, AMF PANEL OF ELECTRIC SUPPLY INSTALLATION AND REPAIR / MAINT OF MCB, DB, FEEDER PILLAR BOX, SECURITY LIGHT IN SYSTEM AND OTHER CONNECTED WORKS INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_671154_1
8299/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹79,000
18 Nov 2024
3 Sept 2024
25 Sept 2024
3 Sept 2024
24 Sept 2024
17 Sept 2024
Amount
Day to Day routine/periodical preventive maintenance of DG set capacity 4 x 500 KVA and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleaner elements & top-Up of Coolant as per Manufacturer`s recommended maintenance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 500 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified here-in-after:- NEW OTM POWER HOUSE : Nos of DG Set - 04 Nos (Make: GREAVES COTTON) Note :- (i) Spares required will be measured and paid separately. (ii) Engine Oil, Engine Oil (Lub Oil) Filter & Fuel Filter of above mentioned DG Set will be replaced twice in a year and will be measured and paid under respective schedule.
Day to Day routine/periodical preventive maintenance of DG set capacity 2x250 KVA and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleaner elements & top-Up of Coolant as per Manufacturer`s recommended maintenance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 250 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified here-in-after:- NEW MAP PHASE II: No of DG- 01(Make: Greave Cotton) Note :- (i)Spares required will be measured and paid separately. (ii) Engine Oil, Engine Oil (Lub Oil) Filter & Fuel Filter of above mentioned DG Set will be replaced twice in a year and will be measured and paid under respective schedule.
Day to Day routine/periodical preventive maintenance of DG set capacity 125 KVA and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleaner elements & top-Up of Coolant as per Manufacturer`s recommended maintenance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 125 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified here-in-after WATER GATE -02 No`s (Make : Greaves Cotton) Note :- (i) Spares required will be measured and paid separately (ii) Engine Oil, Engine Oil (Lub Oil) Filter & Fuel Filter of above mentioned DG Set will be replaced twice in a year and will be measured and paid under respective schedule.
Day to Day routine/periodical preventive maintenance of DG set capacity 62.5 KVA and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleaner elements & top-Up of Coolant as per Manufacturer`s recommended maintenance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 62.5 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified here-in-after:- Power House -01No (Make : Greaves Cotton) & Kalyani-01 (Make: Koel Green) 2x11 =22 Months Note :- (i) Spares required will be measured and paid separately. (ii) Engine Oil, Engine Oil (Lub Oil) Filter & Fuel Filter of above mentioned DG Set will be replaced twice in a year and will be measured and paid under respective schedule.
Notes for Item No 1 to 4 . During each visit under this contract, the following should be carried out by the Service Representative: 1. Drain the Lub Oil from the Sump, Lub oil Cooler etc. and clean the Sump Strainers as per the recommendation in the Operating Instruction Manual. Renew Lub Oil and Filter Elements are required. 2. Refill the sump with new Lub Oil and prime the lubricating system 3. Check and tighten as required, any external bolts. 4. Replace the Fuel Filter Elements as per the recommended procedure. 5. Check and adjust belt tension or replace the belts as required. 6. Check and correct the tightening of all Hoses and Clamps. 7. Check and correct the tightening of terminals at Engine Control Panel and EPU. 8. Check and adjust tappet clearance as required. 9. Check and tighten engine bearer cap screws. 10 Carryout Air Cleaner maintenance as required. 11 Check and record Engine performance parameters. 11. Check and correct external leakages. 12. Check EPU for proper functioning. 13. Checking of Alternator as per check list. 14. Spare parts required will be measured and paid Separately under respective item of schedule.
Supply only spare parts for DG set 500 KVA - 04 Nos Make : Greaves Cotton located at MES NEW OTM Power House. Labour Cost for the items mentioned below will be paid under item no.1
Engine Oil 15W40
Engine Oil (Lub Oil) Filter
Air Filter (Outer)
Air Filter (Inner)
Fuel filter
V - Belt
Supply only spare parts for DG set 250 KVA - 01 Nos Make : Greaves Cotton located at MAP Phase - II. Labour Cost for the items mentioned below will be paid under item No.2
Engine Oil 15W40
Engine Oil (Lub Oil) Filter
Air Filter (Outer)
Air Filter (Inner)
Fuel filter
V - Belt
Supply only spare parts for DG set 125 KVA - 02 Nos Make : Greaves Cotton located at Water Gate Pump House. Labour Cost for the items mentioned below will be paid under item No.3
Engine Oil 15W40
Engine Oil (Lub Oil) Filter
Air Filter (outer)
Air Filter (Inner)
Fuel filter
V - Belt
Supply only spare parts for DG set 62.5 KVA - 02 Nos Make : Greaves Cotton located at Queens Bk Pump House & Kalyani. Labour Cost for the items mentioned below will be paid under item no.4
Engine Oil 15W40
Engine Oil (Lub Oil) Filter
Air Filter (Outer)
Air Filter (Inner)
Fuel filter
V - Belt
M&L for Servicing radiator assembly from its existing position and opening of the radiator, overhauling, cleaning with chemical and mechanical process reassembling with replacement of gaskets and cleaning of fins also and soldering on required leaked galleries for 500 KVA DG Sets.
M&L for Servicing radiator assembly from its existing position and opening of the radiator , overhauling, cleaning with chemical and mechanical process reassembling with replacement of gaskets and cleaning of fins also and soldering on required leaked galleries for 250 KVA DG Sets.
M&L for Servicing radiator assembly from its existing position and opening of the radiator , overhauling, cleaning with chemical and mechanical process reassembling with replacement of gaskets and cleaning of fins also and soldering on required leaked galleries for 125/62.5 KVA DG Sets.
M&L for dismantling carefully Fuel Injection Pump (FIP) of 500 KVA DG Set Opening, cleaning of FIP and nozzles, recalibration with replacement of element, delivery valve and repair kit and refitting to the engine after repair/replacement and making DG SET proper functional.
M&L for dismantling carefully Fuel Injection Pump (FIP) of 250/125 KVA DG Set Opening, cleaning of FIP and nozzles recalibration with replacement of element, Delivery valve and repair kit and refitting to the engine after repair/replacement and making DG SET proper functional.
M&L for dismantling carefully Fuel Injection Pump (FIP) of 62.5 KVA DG Set Opening, cleaning of FIP and nozzles recalibration with replacement of element, Delivery valve and repair kit and refitting to the engine after repair/replacement and making DG SET proper functional.
M&L for dismantling Water Pump Assembly from the 500KVA DG Set from its existing position ,Opening into parts Overhauling the same, repairing and refixing complete to make the DG Set Functional complete all as specified.
M&L for dismantling Water Pump Assembly from the 250/125KVA DG Set, from its existing position, Opening into parts Overhauling the same, repairing and refixing complete to make the DG Set Functional complete all as specified.
M&L for dismantling Water Pump Assembly from the 62.5 KVA DG Set, from its existing position, Opening into parts Overhauling the same, repairing and refixing complete to make the DG Set Functional complete all as specified.
M&L for taking down unserviceable self starter including solenoid switch repairing unserviceable parts like Carbon bush, Pinion, armature, Carbon Brush Holder etc and refixing self starter 24 volt suitable for DG Set 500 KVA all as specified and directed.
M&L for taking down unserviceable self starter including Solenoid Switch and repairing unserviceable parts like Carbon bush, Pinion, armature, Carbon Brush Holder etc and refixing self starter 24 volt suitable for DG Set 250/125 KVA all as specified and directed.
M&L for taking down unserviceable self starter including Solenoid Switch and repairing unserviceable parts like Carbon bush, Pinion , armature ,Carbon Brush Holder etc and refixing self starter 12 volt suitable for DG Set 62.5 KVA all as specified and directed.
M&L for taking down unserviceable 24 Volts Dynamo and repairing by rewinding and Varnishing, heating of coil and refixing suitable for DG Set 500/250/125 KVA all as specified and directed.
M&L for taking down unserviceable 12 Volts Dynamo and repairing by rewinding and Varnishing, heating of coil and refixing suitable for DG Set 62.5 KVA all as specified and directed.
S&F in replacement of Diesel tank cap as per existing type complete all as specified and directed.
S&F in replacement of LED indicator lamp (R,Y,B,G) including taking down old Unserviceable indicator lamps complete all as specified and directed.
S&F in replacement Standard Push Button for ON/OFF/TRIP as per existing at site complete all as specified and directed.
S&F in replacement of Battery Charger 12/24 Volts complete all as specified and directed.
Supply and top up distilled water all as specified and directed.
Supply and top up Pre mixed heavy duty Coolant all as specified and directed.
S&F in replacement of MCB, TPN, 32 Amp, C - Curve 415 Volts Complete all as specified and directed.
M&L for servicing of AMF Panel and Repair and replacement of following spare parts of AMF Panel of capacity 250/125 KVA diesel generating set as per existing complete all as specified and directed by Engineer - in -charge.
AMF Panel Controller for 250 KVA
AMF Panel Controller for 125 KVA
AMF Panel relay for 250 KVA
AMF Panel Contactor for 250 KVA
AMF Panel relay for 125 KVA
AMF Panel Contactor for 125 KVA
M&L for servicing of AMF Panel and and Repair and replacement of following spare parts of AMF Panel of capacity 62.5 KVA diesel generating set as per existing at site complete all as specified and directed by Engineer - in -charge.
AMF Panel Controller for 62.5 KVA
AMF Panel relay for 62.5 KVA
AMF Panel Contactor for 62.5 KVA
Taking Out Automatic Voltage Regulator of Alternator and replacing the same after testing complete for 500 KVA DG Set all as specified and directed.
Taking Out Automatic Voltage Regulator of Alternator and replacing the same after testing complete for 250/125 KVA DG Set all as specified and directed.
Taking Out Automatic Voltage Regulator of Alternator and replacing the same after testing complete for 62.5 KVA DG Set all as specified and directed.
S&F of Battery 12 volt, 180 AH of Make EXIDE/AMORON including taking down old Battery and deposit the Store of AGE E/M Store complete all as per direction of Engr - in - Charge.
S&F in repairs of MCCB 4 Pole, 415 V, 630 Amps with Microprocessor based release breaking capacity 50 KA, Ics=100% of Icu with copper spreader incl taking down existing MCCB complete all as specified and directed.
S&F in replacement motorised change over switch 630 Amps , 4 Pole with inbuilt time delay Cat No CK90167BOOO Make : L&T including taking down old unserviceable Change Over Switch complete all as specified and directed.
S&F in replacement of Power Contactor 400 Amp rating, 4 Pole, 415 Volts, 50 Hz Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 Model MCX 43 2 No + 2 NC Cat No CS97025 Make - L&T including taking down old unserviceable ATC complete all as specified and directed (As per sample).
M&L for opening, cleaning and refixing of diesel tank of 500 KVA DG Set twice during the contract. Cleaning of diesel tank involves draining out of diesel collecting in a vessal and refueling the diesel including repair the minor leakage (if required) complete all as specified and directed by Engr - in- Charge. Note :- (i) Necessary T&P required for opening and refixing should be arranged by the contractor. (ii) Necessary Gas Welding required for repair of leakage of Diesel Tank deemed to quoted rates.
M&L for opening, cleaning and refixing of diesel tank of 250 KVA DG Set twice during the contract. Cleaning of diesel tank involves draining out of diesel collecting in a vessal and refueling the diesel including repair the minor leakage (if required) complete all as specified and directed by Engr - in- Charge. Note :- (i) Necessary T&P required for opening and refixing should be arranged by the contractor. (ii) Necessary Gas Welding required for repair of leakage of Diesel Tank deemed to quoted rates.
M&L for opening, cleaning and refixing of diesel tank of 125KVA DG Set twice during the contract. Cleaning of diesel tank involves draining out of diesel collecting in a vessal and refueling the diesel including repair the minor leakage (if required) complete all as specified and directed by Engr - in- Charge. Note :- (i) Necessary T&P required for opening and refixing should be arranged by the contractor. (ii) Necessary Gas Welding required for repair of leakage of Diesel Tank deemed to quoted rates.
M&L for opening, cleaning and refixing of diesel tank of 62.5KVA DG Set twice during the contract. Cleaning of diesel tank involves draining out of diesel collecting in a vessal and refueling the diesel including repair the minor leakage (if required) complete all as specified and directed by Engr - in- Charge. Note :- (i) Necessary T&P required for opening and refixing should be arranged by the contractor. (ii) Necessary Gas Welding required for repair of leakage of Diesel Tank deemed to Quoted rates.
M&L for taking down unserviceable turbo charger including replacing of existing size & type and refixing turbocharger suitable for DG Set 500 KVA to make DG Set Functional complete all as specified and directed.
Material & labour for taking down unserviceable turbo charger including replacing of existing size & type and refixing turbocharger suitable for DG Set 250 KVA to make DG Set Functional complete all as specified and directed.
Material & labour for taking down unserviceable turbo charger including replacing of existing size & type and refixing turbocharger suitable for DG Set125 KVA to make DG Set Functional complete all as specified and directed.
(a) The contractor shall provide of high skilled mechanic/operator joint during currency of contract period, if required. The cost of the same shall be deem to be included above quoted rate. (b) Comprehensive maintenance include day to day routine/periodical maintenance with replacement of defective equipments/parts as specified shall deem to be include in above quoted rate. (c) Contractor shall rectify the fault within 24 hours as per the direction of AGE E/M or his rep within design limit as specified in PS otherwise shall be recovery as specified in here-in-after. (d) Make and model of part to be replaced shall be as existing at site or as per OEM. (e) The cost of transportation and other necessary equipments shall be arranged/brought by contractor in this effect.
M&L for replacement of sub main wiring with 2 run of 2.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/capping (25mm dia) including size 2.5 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 4 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing capping/ PVC conduit will be measured as one unit.
M&L for replacement of sub main wiring with 2 run of 4 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/capping (25mm dia) including size 4.0 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 4 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing capping/ PVC conduit will be measured as one unit.
M&L for replacement of sub main wiring with 2 run of 6 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/capping (25mm dia) including size 6 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 6 Sqmm pvc wire, one run of 10 Sqmm pvc wire and one run of pvc casing capping/ PVC conduit will be measured as one unit)
M&L for replacement of 3 phase sub main wiring with 2 run of 16 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core multi stranded copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC conduit not less then 25 mm dia ,connected to main switches/DB"S complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface. ( NOTE :- Two runs of 16 Sqmm pvc wire, and one run of 10 sq mm with PVC conduit/PVC flexible pipe will be measured as one unit).
S & F metal clad box enclosure with socket plug top and MCB SP 20 Amps flush mounting enclosure with 2 pin and earth plug socket including taking down old US DB box any size complete all as specified and directed. Make - Havells or Equivalent to Legrand/Schnieder/Hager
Taking down unserviceable point wiring of any size, any type and PVC conduit/ casing capping and removing materials from site and making good the disturbed surface of wall etc complete all as specified and directed.
M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLS copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC casing capping 25/20 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC/wooden switch board on existing wall surface with 3mm thick plastic hylum sheet cover fixed with MS screws and cap washers for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as specified and directed.
All as per Item No 52 here-in-before but for one 5 pin socket outlet 5 Amps on independent board with 1.5 Sqmm complete all as specified and as directed.
All as per item No 52 here-in-before but for one 5 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
All as per Item No 52 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 4 Sqmm copper cable FRLS & 2.5 Sqmm FRLS copper cable for earth continuity wire complete all as specified and as directed.
S&F for switch piano flush type 5 Amp single pole one way complete all as specified and as directed.
S&F for socket flush type 5 Amp 5 Pin complete all as specified and as directed.
S&F for switch socket combination 5 Pin 5 Amp universal complete all as specified and as directed.
S&F for switch socket combination 5 Pin, 5/15 Amp universal complete all as specified and as directed.
S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed.
S&F for sheet metal enclosures for DB’s single door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 2 way without bus bar complete after taking down old unserviceable DB's and including making good the disturbed surface and matching with existing colour complete all as specified and as directed.
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the disturbed surface and matching with existing colour complete all as specified and as directed.
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 6 way with built in bus bar complete after taking down old unserviceable DB's and including making good the disturbed surface and matching with existing colour complete all as specified and directed.
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the disturbed surface and matching with existing colour complete all as specified and directed.
S&F for sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 12 way with built in bus bar complete after taking down old unserviceable DB's and including making good the disturbed surface and matching with existing colour complete all as specified and as directed.
Taking down carefully DB with MCB of any description complete all as directed by Engr-in-charge.
S&F in replacement of sheet metal enclosures for DB’s double door suitable for mounting of TPN/MCB'S/Isolators, 415 Volt, Vertical TPN DB's 8way with built in160A rated bus bar and without TPN complete including making good the disturbed surface and matching with existing colour complete all as specified and directed.
S&F in replacement of sheet metal enclosures for DB’s double door suitable for mounting of TPN/MCB'S/Isolators, 415 Volt, Vertical TPN DB's 6way with built in160A rated bus bar and without TPN complete including making good the disturbed surface and matching with existing colour complete all as specified and directed.
M & L for MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M & L for MCB, SP, 240V, 40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M & L for MCB, SPN, 240 V, 40 Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed.
M&L for MCB, SPN, 240V, 63 Amps and ' C ' series/curve breaking capacity 10 KA complete all as specified and directed .
M&L for MCB, TPN,63 Amps,240 V, and ‘C’ series breaking capacity 15 KA complete all as specified and directed .
Supply and fix ceiling fan regulator electronic Step type, solid state, 100W, 240 volts, complete all as specified and as directed.
S & F call bell, ding dong AC 230 volts, single pole complete all as specified and directed.
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 25KA complete all as specified and directed.
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8 -1 x in short circuit fixed 100 Amps breaking capacity 25KA complete all as specified and directed.
S&F in repair picture LED lights with color temperature 3000 K suitable for 10 W metal and synthetic material lumen 500 lm complete all as specified and directed .Model: 48043/30/86 Make: Philips or equivalent model in other make specified in tender.
S & F in repair LED wall mounted spot focusing light fitting 9 above watt, colour temperature 2700K, mounted on wall / ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed. Make: Philips Cat No 56240/31 or equivalent model in other make specified in tender.
Supply & fixing in repair wall mounted fans 230 volts single phase oscillating 400 mm sweep with white/Black Color with following technical specification Box Dimension 48x24.5x47.5cm wattage 35W ,Air Delivery (CMM)76 Blade Length 40CM,Speed 1500RPM, Item Weight 4.2Kg Voltage 165-285V, Blade Material ABS Plastic including all Fixing accessories for fixing at Wall complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Vento Jet Horizontal Auto Exhaust fan AC single Phase 230 V / 240V 50 Hz of size 150 mm Sweep brushed steel finish / Off White, Automatic front shutter High suction capacity, silent operation, wall, ceiling and glass mounting, Removable & Screw less front for easy cleaning and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
S & F LED decorative Wall lights fitting 4 W x 2, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable E-14 LED 4w X2 complete all as specified and directed. Make: PHILIPS 32033/11/66 Aquafit wall light(Chrome and Metal,12W)-DC or equivalent model in other make specified in tender.
Supply and fixing in repair PVC casing/capping of size 25 mm with all accessories all as directed by Engr-in- charge.
Supply and fixing in repair PVC casing/capping of size 20 mm with all accessories all as directed by Engr-in- charge .
S&F GI in repair tubing medium grade of size 15 mm dia incl painting and making hole for extension of fan hook in high roof ceiling complete all as specified.
S & F in repair clamp with buckle for hanging ceiling fan including nut and bolts complete set all as specified and directed.
M&L for earthling complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI strip protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessary testing on completion all as shown in electrical plate No 3 MES schedule part-I complete all as specified and as directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
GHOSH ENTERPRISE (BID ID -3110200)
PRABIR TRADERS (BID ID -3110479)
JAGATMATA ENTERPRISE (BID ID -3105702)
CHOWDHURY SMALL INDUSTRIES (BID ID -3107158)
DUTTA & DUTTA (BID ID -3109836)
SILKTONE (BID ID -3109935)
R R ENTERPRISE (BID ID -3101621)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .