Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹31.3 L+₹37,572.60 (1.22%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹31.3 L+₹41,506.50 (1.34%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹31.9 L+₹94,115.60 (3.04%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹38.3 L+₹7.4 L (23.8%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹41.0 L
EMD Value
₹81,920
Closing Date
20 Feb 2020, 6:00 pmClosed
GARRISON ENGINEER EAST JALANDHAR CANTT
GARRISON ENGINEER EAST JALANDHAR CANTT
SPECIAL REPAIR TO ROOF TREATMENT OF DAD RESIDENTIAL COLONY AND DAD OFFICE COMPLEX AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2020_MES_314878_1
GE/JULL/ET-58/2019-20
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
as per tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER EAST JALANDHAR CANTT
₹81,920
Yes
12 Mar 2020
23 Jan 2020
21 Feb 2020
23 Jan 2020
20 Feb 2020
8 Feb 2020
Amount
Surface excavation in soft/ loose soil n. exc. 30cm deep and averaging 15cm deep and getting out all as directed and specified.
Rough excavation n.exc 1.5m deep and getting out in soft/ loose soil complete all as specified and directed
Excavation over areas n.exc. 1.5m in depth for foundation of manholes and getting out in soft/ loose soil complete all as specified and directed
Excavation in trenches in soft/ loose soil, not exceeding 1.5 m wide and not exceeding 1.5m in depth for foundations etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 sqm on plan and getting out complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in roof pedding, foundation filling, mass concrete etc complete all as specified and directed.
M&L cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in concrete bed to 150mm and 200mm borereinforced concrete pipes,, class NP2 drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25 cm thick each layer complete all as specified and directed.
Removing excavated material (soils) to a distance n. exc. 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Removing excavted soil exc 50m but n.exc 250m and depositing where complete all as specified and directed
M&L for rendering 15mm thick cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L preparation of newly plastered or un-plastered surface of walls including cornices, pilasters etc. and applying two coats of cement base paint complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate), as in sub floors, sub base, hard standing, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified & directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate), as in sub floors, sub base, hard standing, concrete surfaces finished fair & even to receive topping floor finish/layer complete all as specified & directed.
M&L 150mm bore reinforced concrete pipe, class NP2, laid and jointed with collars complete all as specified and directed.
M&L hard core of broken stone or boulder of gauge n. exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and well rammed to a true surface complete all as specified and directed.
M&L 15mm bore galvanised steel tubes, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc complete all as specified and directed.
S&F PVC connection fiber, reinforced 45cm long 15mm in size with brass check nut and PVC washers at both ends complete all as specified and directed.
S&F 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 210 gms) complete all as specified and directed.
S&F stop valves 15mm bore, cast copper alloy, screwed down with high pressure with crutch or butterfly handles, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
M&L rendering 10mm thick cement plaster on brick or concrete surfaces in cement mortar (1:3) mixed with integral water proofing compound in the proportion recommended by manufacturer, surfaces finished fair and even complete all as specified and directed. Note : WPC shall be measured and paid separately.
M&L for applying a coat of hot blown paving industrial bitumen 85/25 at the rate of 1.20 kg/ sqm over the roof suface including cleaning surfaces complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3kg/ sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/ sqm) laid on primed surface by forced application complete all as specified complete all as specified and directed.
Dismantling of brick tiles single layer as in roof covering all as specified and directed.
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3) complete all as specified and directed.
Wire brushing and cleaning top surface of cement concrete, including flashing and junction of parapets etc complete all as specified and directed
M&L for brushing neat cement slurry with 2.75 kg of cement per sqm complete all as specified and directed.
M&L coloured reflective type 60mm thick machine pressed precast concrete inter-locking paver blocks any shape and size conforming to IS 15658-2006, M-35 grade laid in floor/ path/ hardstandings in any pattern as approved, laid over and including 25mm thick sand cushion and interstices filled with sand using plate vibrator complete all as specified and directed.
M&L 80mm thick machine pressed precast concrete inter-locking paver blocks any shape and size conforming to IS 15658-2006, M-40 grade, with grey cement and pigment, laid in floor/ path/ hardstandings in any pattern as approved, laid over and including 30mm thick sand cushion and interstices filled with sand using plate vibrator complete all as specified and directed.
M&L sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands plinth cources, roof kerbs or mud stops, benching, coping, bed plates, parapets, water throughs and the like etc including weathering, slightly rounded or chamfered angles throating, edges of interlocking/ chequered tiles etc complete including necessary form work complete all as specified and directed.
M&L MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note: Unexposed surface shall be given one coat of primer only.
Taking down cross arms, channels, angle iron, clamps, nuts, bolts, stay wire, stay assembly, GI wire etc. complete all as specified and directed.
M&L for PCC tiles 250X250X22mm laid over 15mm thick screed bed, set jointed and pointed in neat cement slurry as in roof with grey and pigment complete all as specified and directed.
Boring hole under the road/pavement / hard standing with the help of trenchless technology and necssary machine for inserting GI pipe of suitable dia at a depth not less than one metre below ground level complete all as specified & directed by Engineer-in-Charge.
S&F evaporative air cooler (Desert Cooler) of capacity 5000 Cum/Hr discharge in steel body made out of sheet 18 SWG for main body and 22 SWG for side covers duly painted with two coats of hammer tone paint 1st quality over a coat of red oxide primer complete inner and outer sides with front grill made out steel (heavy duty), propeller cooler fan (aluminium blades) 500mm sweep dia with heavy duty motor, AC single phase, 230 volts, 50 C/s copper wound with submersible pumps complete.
M&L submain wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through PVC rigid nonmetallic concealed/ surface conduit including earth continuity FRLS copper conductor 2.5 Sqmm PVC insulated with green insulation all as specified and directed. Note : Two runs of cable 4.0 Sqmm, one run of cable 2.5 Sqmm and one Run of PVC conduit will be measured as one unit RM.
M&L submain wiring with PVC insulated cable copper conductor FRLS two single core 2.5 Sqmm drawn through PVC rigid nonmetallic concealed/ surface conduit including earth continuity FRLS copper conductor 1.5 Sqmm PVC insulated with green insulation including taking down complete and directed. Note : Two runs of cable 2.5 Sqmm, one run of cable 1.5 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Dismantling insulators any type and size from existing LT poles all as specified and directed.
Dismantling ACSR conductors from existing feeders all as specified and directed.
Taking down old LT cable fo any size 95 Sqmm 3½ Core complete all as specified and directed
Taking down old LT cable fo any size 10 Sqmm 2 Core complete all as specified and directed
Taking down old LT cable fo any size 25/35 Sqmm 3½ Core complete all as specified and directed
Supplying, Laying, jointing and testing LT underground XLPE insulated, armoured, heavy duty electric cable PVC sheathed with strandard aluminium conductor, 1100 volts grade of size 150 Sqmm 3½ core, laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed. Note: Excavation & earthwork, sand cushioning, brick protection cover, GI protection pipe and clamps shall be measured and paid for separately.
All as per Srl Item No. 47.00 here-in-before but of size 120 Sqmm 3½ core
All as per Srl Item No. 47.00 here-in-before but of size 95 Sqmm 3½ core
All as per Srl Item No. 47.00 here-in-before but of size 35 Sqmm 3½ core
All as per Srl Item No. 47.00 here-in-before but of size 25 Sqmm 3½ core
All as per Srl Item No. 47.00 here-in-before but of size 16 Sqmm 4 core
All as per Srl Item No. 47.00 here-in-before but of size 10 Sqmm 2 core
M&L sand for cushioning with 8cm thick layer before laying of cable and 15cm thick layer after laying of cable in trenches complete all as specified and directed.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
S&F 40mm bore galvanised pipe light grade for passing of cable fixed to poles/ walls/ laying under floor complete with and including fittings and clamps as required complete all as specified and directed.
All as per Srl item No. 56.00 here-in-before but 50mm bore
M&L preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and numbering of poles including painting of street light brackets, clamps etc complete all as specified and directed.
Earthing complete for LT poles with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate to a depth not less than 1.50 metre below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore medium grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and 20mm bore of GI pipe medium grade watering pipe with funnel and wire mesh, PCC chamber of size 300 x 300mm (top of chamber minimum 15 cm above the normal ground level in PCC (1:3:6) using 20mm graded stone aggregate with and including 50mm thick RCC cover in (1:2:4) type B-1 using 20mm graded crushed stone aggregate with 2 nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account.
All as per srl item No. 59.00 here-in-before but earthing using 4mm GI wire as earth lead in 15mm bore protection pipe and galvanised earth plate of size 60cm x 60cm x 6mm as earth electrode.
Supply, installing, testing and commissioning feeder pillar, outdoor cubicle type weather and vermin proof totally enclosed made out of 3.15mm thick CRCA sheet machine pressed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement including inner independent enclosures for all switches/ MCCBs/ metering equipments with hinged (bottle type) shutters, bottom gland plate with sufficient numbers of circular cable entry holes with cable glands of suitable size of cable & with suitable cable glands as per number of outgoings, prewired complete duly powder coated with 7 tank process with base frame made of angle iron 50 mm x 50 mm x 6 mm, legs 100 cm long having openable apron on all three sides of panel 30 cm wide and grouted 45 cm in PCC (1:3:6) type C-1 including brick masonary platform 45cm above ground level all as specified and directedby Engr-in-charge, comprising with following complete:- (i) Bus bar suitable for 3 phase, 415 volts, 50 Hz, 4 wire system of rating 350 Amps made out copper strip of suitable size (strip size be based on 1.5 Amps per sqmm), with coloured heat shrinkable sleaves in four colours (Red, yellow, blue and black) fixed on resin cast insulators including galvanised nuts, bolts and washers etc fitted with and including the following :-
(ii) INCOMING : - (a) MCCB 160 Amp, 415 V, 25 KA, 4 pole with fixed thermal magnetic release ICS=ICU=100%-01 No. (b) Energy meter with LCD display , accuracy class 1.0, having parameters KW, KWh, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete. (c) Phase Indicator LED type in red, yellow and blue colours protected with and including MCB SP of suitable rating - 01 sets (iii) OUTGOING:- (a) MCCB 100 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release, ICS=ICU=100%-01 No. (b) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release, ICS=ICU=100%-03 Nos. (c) MCCB 40 Amp, 415 V, 16 KA, 4 pole with e thermal magnetic release, ICS=ICU=100%-01 No. (d) MCB SPN 40 Amp -03 Nos (e) Phase indicator LeD type in red, yellow and blue colours protected with and including MCb SP of suitable rating-05 sets.
All as per Srl Item No. 61.00 here-in-before but consisting with the following :- (i) Bus bar suitable for 3 phase, 415 volts, 50 Hz, 4 wire system of rating 250 Amps made out copper strip of suitable size (strip size be based on 1.5 Amps per sqmm), with coloured heat shrinkable sleaves in four colours (Red, yellow, blue and black) fixed on resin cast insulators including galvanised nuts, bolts and washers etc fitted with and including the following :- (ii) INCOMING : - (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release ICS=ICU=100%-01 No. (b) Three phase digital volt meter, CI 0.5- 01 No. (c) Three phase digital ammeter, CI 0.5 with suitable CTs-01 No. (d) Phase Indicator LED type in red, yellow and blue colours protected with and including MCB SP of suitable rating - 01 set (iii) OUTGOING:- (a) MCCB 63 Amp, 415 V, 16 KA, 4 pole with e thermal magnetic release, ICS=ICU=100%-04 No. (c) MCB SPN 40 Amp - 03 Nos (d) Onload change over switch open execution type 4 pole 100A 415 Volt-01 No. (e) Phase indicator LeD type in red, yellow and blue colours protected with and including MCb SP of suitable rating-07 sets.
Supply, installing, testing and commissioning in-replacement Busbar box with factory fabricated prewired bus bar, cubical type of appropriate size out door dust vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.15mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high , embedded in accommodate the following accessories :- (A) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release ICS=ICU=100% with spreader links , . (B) Copper bus bar 150 A for three phase and neutral duly insulated with sleeves of different colour RYB (C) Volt meter-01 No Note for Srl No. 61.00 to 63.00 : (a) For MCCB's in all LT panels ultimate breaking capacity should be equal to service breaking capacity. (b) Drawing of LT panels shall be got approved from GE before placement of order.
S&F 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 6 Sqmm flat twin core cable in service connection all as specified and directed.
S&F and connecting MCCB Enclosures, 4 pole with single door of suitable size for fixing of MCCB of size 63 Amp all as specified and directed.
S&F MCCB 63 Amps, 4 pole, with thermal magnetic release, ICS=ICU=100%, 415 volts, 50 HZ, 16 KA with spreader links complete all as specified and directed
S&F SPN DB single door 2 way with and including MCB SPN 40A all as per specified and directed.
S&F rigid PVC conduit of size 20mm exclusive of boxes (Junction/ terminal) but inclusive of fittings such as bend, junction boxes, tee etc complete all as specified
All as per Srl item No. 68.00 here-in-before but of size 25mm
Supply & fixing factory made junction box of size 250 x 300 x 125mm suitable for street light fixed on pole, made out of CRCA sheet 2mm thick having front hinged shutter with lockable arrangements, outdoor type, weather proof duly painted with two coats of synthetic enameled paint over a coat of red oxide primer, having the provision to connect incoming and outgoing cable of size 25 sqmm 4 core and one number MCB SPN, 10 KA, C-curve, 6 Amps, 240 volts and earthing plug complete all as specified and directed. Note : MS Clamps, nuts, bolts required to fixing on pole shall be measured and paid separately.
M&L for point wiring with 1.5 Sqmm, PVC insulated unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit fire proof ISI marked 20mm dia or higher complete with all conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel terminal switch box 1.6mm thick with 3 mm thick plastic laminated sheet top cover, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in color as continous earth conductor connected to common earth and earth dolly with all accessories for one light point controlled by one switch complete all as specified and directed
Supply & Fixing switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified.
S&F socket outlet 3 pin, 5 Amp flush type complete all as specified and directed.
S&F of fabricated MS angle iron stand for desert coolers made out of angle iron of size 40mm x 40mm x 4 mm of frame of size 68cm x 68cm at top at 10 cms above ground level and 90 cms height provided with 2 Nos supported on top frame made out of MS strip of size 25mm x 4mm including welding grinding finishing and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M/s Pardeep Kumar
M/S Vinod Kumar
PAUL CONSTRUCTION CO.
BHARAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .