| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAdmitted-Finance ADHYARU INDUSTRIAL EST STORE NO 3 1ST FLOOR SUN MILL COMPOUND LOWER PAREL MUMBAI 400013 | MUMBAI | MUMBAI | MAHARASHTRA | 400013 | ₹17.0 L | L1 | Admitted-Finance |
| 2 | L2₹17.9 LAdmitted-Finance DHARAVI MAIN ROAD GROUND FLOOR ROOM NO 130 NEW SIDDHARTH CHAWL BAGICHA MUMBAI 400017 | MUMBAI | MUMBAI | MAHARASHTRA | 400017 | ₹17.9 L | L2 | Admitted-Finance |
| 3 | L3₹18.2 LAdmitted-Finance ROOM NO 2 BUILDING NO 1 ROMA BANJARA TANDA CHS LTD NEW CHIKUWADI MANKHURD MANKHURD MUMBAI MAHARASHTRA 400043 UDYAM MH 19 0049421 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | ₹18.2 L | L3 | Admitted-Finance |
| 4 | L4₹21.7 LAdmitted-Finance 102 R RESIDENCY PLOT 39 SEC 19 BEHIND HOTEL MALWAN ULWE NODE NAVI MUMBAI | NAVI MUMBAI | MAHARASHTRA | ₹21.7 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical APOORVA CHITARI EXECUTIVE II EFD ENGINEERING FACILITIES DIVISION AI ENGINEERING SERVICES LIMITED OLD AIRPORT KALINA SANTACRUZ EAST MUMBAI 400029 TELEPHONE 022 20752600 EXTENSION 240 | MUMBAI SUBURBAN | MAHARASHTRA | 400029 | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | s.pol enterprises L2 | Ramesh Electrical and Mechanical Works L1 | OM POWER SYSTEMS L4 | MEGHA ELECTRICAL ENGINEERING L3 |
|---|---|---|---|---|---|---|---|
| 1.00Providing Point wiring for Light point/ Ceiling Fan Point/ Bell Point/ 6A Socket Outlet /16 A Socket Outlet/ Water Heater/Air conditioner etc. with 1100 grade FRLS , PVC insulated multistrand copper wire in Casing Capping on wall /Ceiling including Crossing of Wall / slab with Controlling Switches/Socket Outlet /ceiling fan regulator on PVC white plate with Metal frame mounted on surface mounted rigid sturdy plastic white surface Box , PVC square Box , angle/Batten Lamp Holder, 3 plate ceiling rose terminal connector Block, ferrule number of both side, PVC insulated copper conductor wires for earthing of said specification and labelling etc all as per specification of tender document. Scope shall Include providing the tags of wires inside casing capping for bunching to avoid hanging of wire at the interval of 600 mm and as directed by Engineer-In-Charge. Note: Supply of all required material in contractor scope. | |||||||
| 1.10 | Light point with 1.5 sq. FRLS 1.1 kV grade copper stranded wires complete with 6A, SP, 240V controlling switch, Lamp Holder, Square Box, Surface Mounted switch Board with white plate with frame, Casing Capping, and necessary accessories/ hardware etc. | 90 | No | 76,500 ₹90,270 | 1,61,550 ₹1.9 L | 1,48,050 ₹1.7 L | 2,52,000 ₹3.0 L |
| 1.20 | Ceiling fan point with 1.5 sq.mm FRLS 1.1 kV grade copper stranded wires complete with 6A, SP, 240V switch & capacitor type 5-step regulator, Square Box, Surface Mounted switch Board with white plate with frame, Casing Capping, and necessary accessories/ hardware etc | 39 | No | 33,150 ₹39,117 | 71,565 ₹84,446.70 | 74,100 ₹87,438 | 97,500 ₹1.2 L |
| 1.30 | 16A, 6-Pin socket outlet point with 2.5 sq.mm. FRLS 1.1 kV grade copper stranded wires complete with 6/16A, 240V, 6-Pin socket outlet with 16A, SP, 240V controlling switch, surface Mounted switch Board with white plate with frame , Casing Capping, and necessary accessories/ hardware etc | 59 | No | 50,150 ₹59,177 | 2,48,685 ₹2.9 L | 1,20,950 ₹1.4 L | 2,24,200 ₹2.6 L |
| 2.00Supply, Installation, Testing and commissioning of ceiling fan including wiring the down rods of length 300 mm with 1.5 sq.mm. copper stranded twisted wire, including providing and fixing phenolic laminated sheet cover on the fan box etc. as per Tender document & as instructed by Engineer-In-Charge. | |||||||
| 2.10 | Ceiling Fan size 1200mm | 40 | Each | 83,760 ₹98,836.80 | 1,16,000 ₹1.4 L | 2,00,000 ₹2.4 L | 1,00,000 ₹1.2 L |
| 3.00Supply & Installation of end termination of following size of cables including compressed type brass glands, crimping type copper lugs,etc as 'required complete with earthing of glands as per tender document & as instructed by Engineer-incharge. | |||||||
| 3.10 | 4 C x 16.0 sq.mm. copper Armoured cable | 5 | Each | 1,300 ₹1,534 | 1,625 ₹1,917.50 | 4,500 ₹5,310 | 3,000 ₹3,540 |
| 3.20 | 4 C x 10.0 sq.mm. copper Armoured cable | 6 | Each | 1,176 ₹1,387.68 | 1,920 ₹2,265.60 | 5,100 ₹6,018 | 3,000 ₹3,540 |
| 3.30 | 4 C x 4.0 sq.mm. copper Armoured cable | 20 | Each | 3,200 ₹3,776 | 5,300 ₹6,254 | 15,000 ₹17,700 | 6,000 ₹7,080 |
Tender Value
₹21.0 L
EMD Value
₹41,920
Closing Date
27 Sept 2025, 3:00 pmClosed
Director TIFR
TIFR, Mumbai
Electrical Re-wiring work for common area, basement of Bhaskara Building at TIFR Housing complex, Homi Bhabha Road, Colaba, Mumbai 400005
2025_DAE_872558_2
TIFR/PD/CF25-23/250759
Open Tender
Electrical Works
365 days
TIFR Mumbai
As per attached document
5 documents required · 5 mandatory
₹0
₹41,920
15 Dec 2025
11 Sept 2025
29 Sept 2025
12 Sept 2025
27 Sept 2025
12 Sept 2025
Providing Point wiring for Light point/ Ceiling Fan Point/ Bell Point/ 6A Socket Outlet /16 A Socket Outlet/ Water Heater/Air conditioner etc. with 1100 grade FRLS , PVC insulated multistrand copper wire in Casing Capping on wall /Ceiling including Crossing of Wall / slab with Controlling Switches/Socket Outlet /ceiling fan regulator on PVC white plate with Metal frame mounted on surface mounted rigid sturdy plastic white surface Box , PVC square Box , angle/Batten Lamp Holder, 3 plate ceiling rose terminal connector Block, ferrule number of both side, PVC insulated copper conductor wires for earthing of said specification and labelling etc all as per specification of tender document. Scope shall Include providing the tags of wires inside casing capping for bunching to avoid hanging of wire at the interval of 600 mm and as directed by Engineer-In-Charge. Note: Supply of all required material in contractor scope.
Light point with 1.5 sq. FRLS 1.1 kV grade copper stranded wires complete with 6A, SP, 240V controlling switch, Lamp Holder, Square Box, Surface Mounted switch Board with white plate with frame, Casing Capping, and necessary accessories/ hardware etc.
Ceiling fan point with 1.5 sq.mm FRLS 1.1 kV grade copper stranded wires complete with 6A, SP, 240V switch & capacitor type 5-step regulator, Square Box, Surface Mounted switch Board with white plate with frame, Casing Capping, and necessary accessories/ hardware etc
16A, 6-Pin socket outlet point with 2.5 sq.mm. FRLS 1.1 kV grade copper stranded wires complete with 6/16A, 240V, 6-Pin socket outlet with 16A, SP, 240V controlling switch, surface Mounted switch Board with white plate with frame , Casing Capping, and necessary accessories/ hardware etc
Supply, Installation, Testing and commissioning of ceiling fan including wiring the down rods of length 300 mm with 1.5 sq.mm. copper stranded twisted wire, including providing and fixing phenolic laminated sheet cover on the fan box etc. as per Tender document & as instructed by Engineer-In-Charge.
Ceiling Fan size 1200mm
Supply & Installation of end termination of following size of cables including compressed type brass glands, crimping type copper lugs,etc as 'required complete with earthing of glands as per tender document & as instructed by Engineer-incharge.
4 C x 16.0 sq.mm. copper Armoured cable
4 C x 10.0 sq.mm. copper Armoured cable
4 C x 4.0 sq.mm. copper Armoured cable
4 C x 2.5 sq.mm. copper Armoured cable
4 C x 1.5 sq.mm. copper Armoured cable
Complete Dismantling of existing concealed wiring, switches, sockets, ceiling roses, holders, cut-outs, Switch boards, at every floor corridor/common area/ stair case, DB at stilt area/common area of Building Wing ( Each Jobs per wing- total 5 wing of 10 floor including basement ans stilt area) and segregation of accessories etc including providing temporary power supply arrangement from existing flat DB / common area DB as necessary during rewiring as required and necessary civil work to fill unused switch board/DB box on wall/ Ceiling as per Tender document & as instructed by Engineer-In-Charge.(Please refer tender document)
Supply of 1100 V grade XLPE insulated armoured cable , stranded copper conductor as per tender document & instructed by the engineer-in-charge of following size.
4.0 sq.mm., 4 core
2.5 sq.mm., 4 core
1.5 sq.mm., 4 core
Supply of Electrolytic Bare copper conductor, 14 SWG suitable for earthing for Electrical installation as per tender document & instructed by engineer-in-charge
Laying and fixing of following armoured, XLPE power cable of 1.1 KV grade on wall / surface/ Ceiling/ beam/ External Wall/ Floor Crossing/ Wall Crossing/Shaft along with Earthing Wire through route shown using GI Saddle & Spacer of suitable size as per tender document & as directed by engineer-in-charge
4 C X 10.0 Sq.mm. Copper armoured Cable.
4 C X 4.0 Sq.mm. Copper armoured Cable.
4 C X 2.5 Sq.mm. Copper armoured Cable.
4 C X 1.5 Sq.mm. Copper armoured Cable.
Supply, installation, Testing and commissioning of TPN DB - 4-way DB ( 8+12) , Cat No- 5076 70, three pole and neutral, MCB distribution Board suitable for 415 V, 50 Hz, with provision for FP MCB/Isolator/RCCB/RCBO as incomer and provision for SP MCB supply shall be installed on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections complete with all accessories, hardware and following MCBs as per Tender document & instructed by Engineer-In-Charge. (i) TP , MCB, 40 A - 1 No (ii) SP, MCB,16 A - 2 Nos (iii) SP, MCB,20 A - 2 Nos (iv) SP, MCB,25 A - 2 Nos
Supply, installation, Testing and commissioning of SPN DB - 8-way DB ) , Cat No- 5076 11, three pole and neutral, MCB distribution Board suitable for 415 V, 50 Hz, with provision for FP MCB/Isolator/RCCB/RCBO as incomer and provision for SP MCB supply shall be installed on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections complete with all accessories, hardware and following MCBs as per Tender document & instructed by Engineer-In-Charge. (i) DP , MCB, 32 A - 1 No (ii) SP, MCB,20 A - 1 Nos (iv) SP, MCB,16 A - 2 Nos
Supply, Installation, Testing and commissioning of DP Enclosure , cat No – 5077 91, Legrand make with DP MCB, 20 A
Supply & installation of GRP Junction Box of size 120 X 120 X 100 mm with DIN rail mounted Terminal connector for Loop in – Loop Out suitable for connection of 4 core 1/5/ 2.5 sq.mm. armoured cable as per tender document & as instructed by engineer-in charge.
s.pol enterprises (BID ID -3288274)
MEGHA ELECTRICAL ENGINEERING (BID ID -3289643)
OM POWER SYSTEMS (BID ID -3289827)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid