Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.1 L+₹3.5 L (12.6%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹31.7 L+₹4.1 L (14.9%)Rejected-Finance 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹33.3 L+₹5.6 L (20.5%)Rejected-Finance 548 C 259 CHANDRODAYA NAGAR DEOPUR PARA LUCKNOW 226017 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226017 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹34.7 L+₹7.0 L (25.5%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
4 Apr 2022, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
SPL REPAIR/ REPLACEMENT OF OLD ALUMINIUM WIRING TO COPPER WITH FITTINGS FIXTURE SUBMAIN WIRING, DBs OF BLDG. NO P-77 TO P-97 (74 QTR) AT DEFENCE COLONY UNDER GE (EAST) LUCKNOW
2022_MES_512344_1
GE/E/LKO/T-86 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE EAST LUCKNOW
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹79,000
Yes
23 May 2022
7 Mar 2022
6 Apr 2022
7 Mar 2022
4 Apr 2022
22 Mar 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures and making good disturbed surfaces of wall, floor etc and matching with original colour of wall complete all as specified & directed.
Taking down carefully copper/aluminium sub main wiring from existing concealed PVC conduit complete and making good disturbed surfaces of wall, floor etc and matching with original colour of wall complete all as specified & directed.
Taking down carefully electric meter by disconnecting all electric connection and kept at site and refixing the same after completion of wiring including suitable connecting of electric connection complete all as specified & directed.
M&L for one light/fan/exhaust fan point wiring controlled by one witch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including surface /concealed PVC conduit medium grade, ISI marked not less than 19.5 mm / 20 mm dia along with conduit fixing accessories and with pressed steel terminal box for mounting of Hylem sheet plates of thickness 6mm thick terminal boxes concealed on wall/floor/ceiling, with 3 mm thick laminated sheet top cover ISI marked. Make: Hylum for fixing of switches/socket/regulator with brass screws cup washer complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing one and white wash/colour wash complete all as specified & directed.
All as per item No 4 above but 5 Amp socket outlet, independent.
All as per item No 4 above but on the same board.
All as per item No 4 above but for one light point controlled by two, 2- way switch.
All as per item No 4 above but 2.5 sqmm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sqmm connected to common earth dolly.
S&F switch piano flush type 5 Amp one way, single pole, 240 volts complete all as specified & directed.
S&F switch piano type 5 Amp, 2 way, 240 volts complete all as specified & directed.
S&F in repair socket outlet 5 Amp, 5 Pin, 240 volt, flush type, complete all as specified & directed.
S&F in repair switch socket outlet, two in one 5 & 15 Amp, 6 pin, multipurpose combination, complete all as specified & directed.
S&F in replacement ceiling rose two or three terminals surfaces bakelite 65 x 50mm size complete all as specified & directed.
S&F in replacement lamp holder bakelite with back plate suitable for batten fittings complete all as specified & directed.
S&F lamp 9 watt (bulb ) complete all as specified & directed.
S&F ceiling fan regulator electronic stepped type for 1200/1400 mm sweep complete all as specified & directed.
S&F in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC or philips cat no TMC 100 1xT LED /MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen as approved by GE.
S&F the 10 watt LED Mirror light fitting complete all as specified & directed. Make CG cat pat No-LDL-10-WW or equivalent of Bajaj/philips as approved by GE.
S&F LED building security light 36W IP 65 including one number MS clamps made of 25X3 mm flat iron with bracket of GI pipe light grade 25mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting, connecting with three core copper flexible wire 23/0.0076 complete all as specified and directed.
S&F energy saving 10W LED bulk head fitting with opal diffuser including one LED bulb 10W complete all as specified & directed.
Taking down unserviceable DBs including MCBs, supply and fix MCB DB TPN 4 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works complete all as specified & directed.
Taking down unserviceable DBs including MCCB and MCBs, supply and fix MCCB DB VTPN 8 way double door type suitable for TP/FP including necessary dummy plate and necessary civil works all as specified and directed.
S&F in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified & directed.
S&F in replacement MCB, single pole, 240 Volts, of capacity (6-32 Amps) as ordered breaking capacity 10 KA complete all as specified & directed.
S&F in repair MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as specified & directed.
M&L for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces complete all as specified & directed.
M&L for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
M&L for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
S&F ABS junction box for electric meter for five meter universal project enclosure with transparent cover with water and fire proof as per sample complete all as specified & directed
S&F ABS junction box for electric meter for three meter universal project enclosure with transparent cover with water and fire proof as per sample complete all as specified & directed.
Cutting chases in concrete wall/stone for laying PVC conduit and making good to facings where required and pointing in CM 1:3, and making good, cutting not exc 20 cm girth complete all as specified & directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, earth plate connected with GI wire 4mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm including bore provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
M/s PS Associates
HS ASSOCIATES
M/S National Electrical and Electronics Services
rajan construction
m/s raghubar dayal
M/S Nav Jyoti Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .