| 1 | 1₹50.2 LAccepted-AOC MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | 1 | Accepted-AOC Acceptance OF Tender | |
| 2 | 2₹62.3 L+₹7.5 L (13.6%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹78.4 L+₹23.5 L (42.9%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹80.3 L+₹25.4 L (46.3%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹80.8 L+₹25.9 L (47.1%)Rejected-Finance 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | 5 | Rejected-Finance Not L1 |
Tender Value
₹80 L
EMD Value
₹1.6 L
Closing Date
16 Sept 2024, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
REPAIR/REPLACEMENT OF INTERNAL WIRING FITTINGS AND FIXTURES AND SOLAR WATER HEATER /CEILING FANS/ WALL FAN/ GEYSER AND CONNECTED WKS OF OTM AREA AMC CENTRE AND COLLEGE UNDER GE (EAST) LUCKNOW
2024_MES_668043_1
CWE/LKO/E/T-38 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1.6 L
Yes
10 Oct 2024
25 Jul 2024
18 Sept 2024
25 Jul 2024
16 Sept 2024
15 Aug 2024
25 Jul 2024 - 15 Aug 2024
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete except fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick Hylem laminated sheet top cover, steel screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 02 here-in-before but one bell point controlled by one bell push, 06 Amp.
All as per serial item No 02 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Serial Item No 02 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick modular type ( including metal flush box) etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
Taking down OLD U/S Switch/socket/Ceiling rose/calling bell/bell push/lamp holder/Regulator any type and size complete all as specified and directed.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Modular White cover plate with frame,18 module complete all as specified and as directed
S&F White cover plate with frame,12 module complete all as specified and as directed
S&F Modular White cover plate with frame,8 module complete all as specified and as directed
S&F Modular White cover plate with frame,6 module complete all as specified and as directed
S&F Modular White cover plate with frame,4 module complete all as specified and as directed
S&F Modular White cover plate with frame,3 module complete all as specified and as directed
S&F Modular White cover plate with frame,2 module complete all as specified and as directed
S&F Calling bell , AC, 230 Volts, single phase complete all as specified and as directed
S&F bell push , AC, 230 Volts, 2 module complete all as specified and as directed
Supply and fixing fan step regulator, 120W 2 module Modular type complete all as specified and as directed
Supply and fixing switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
Supply and fixing switch piano flush type, 06 Amp, single pole, two way, 230 volt complete all as specified & directed.
Supply and fixing bell push, flush type, 06 Amp, 230 volt complete all as specified & directed.
Supply and fixing socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
Supply and fixing switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
Supply and fixing electronic ceiling fan regulator piano type with rotary step, two module, piano type, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete all as specified & directed.
Supply and fixing lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
Supply and fixing replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
Supply and fix in replacement LED tube light fittings 1200 mm, 20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycabonate without powder coating enviromental friendly, energy efficient complete all as specified and directed.
M &L in replacement for batten suitable for replacement type LED TUBE LIGHT 4' feet long incl prewired complete all as specified and directed by Eng-in-charge.
S&F inreplacement LED tube rod 4' long and 20W complete all as specified and directed by Eng-in-charge.
Supply and fix in replacement LED tube light fittings 600 mm,10/12W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycabonate enviromental friendly, energy efficient complete all as specified and directed.
Supply & fix in replacement LED wall/surface mounted down lighter, 6 to 12 W including electrical connection with copper flexible wire & all necessary fixing accessories complete all as specified.
Supply and fix in replacement ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Supply and fixing in replacement of LED flameproof tube light fitting CMRI certified 1x20 Watt LED Tube light fixture complete with all accessories prewired and incl connecting up with twin core twisted copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing in replacement of LED flameproof tube light fitting CMRI certified 2x20 Watt LED Tube light fixture complete with all accessories prewired and incl connecting up with twin core twisted copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing 1X9 Watt square shaped integral decorative LED (warm white)Bollard polycarbonate diffuser and IP 65 protection and mounting of fitting with PCC foundation all as directed.
Supply and fixing in replacement sensor based integrated LED tube light LED tube light fittings 1200 mm, 20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycabonate without powder coating enviromental friendly, energy efficientall as directed.
Supply and fix in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply & fix in replacement LED Ceiling /surface mounted down lighter, 2'X2' , 36W including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified.
Supply and fix in replacement LED 40/36 watt light pureline slim suspended 50mm suspended (hanging type) aluminium extruded linear lighting luminaries with superior white powder coated finish, multiply option options of lights distrubution run length and luman packages for diffrent application to choose white colour higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminium housing enviromental friendly, energy efficient complete all as specified and directed.
Supply & fix in replacement LED Ceiling /surface mounted down lighter, 2'X2' , 36W sensor based including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified.
Supply & fix in replacement LED Ceiling /surface mounted down lighter warm white / white colour,12 to18 watt round/ squre profile,including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified.
Supply only LED bulb chargable type having backup time of 3 to 4 hours 18 Watts suitable for B22 white in colour all as specified and directed.
Supply and fixing in replacement only LED bulb 9 Watts suitable for B22 Warm white in colour all as specified and directed.
Supply in replacement only LED bulb 9/10 Watts suitable for B22 white in colour all as specified and directed.
S&F in replacement of LED flood light 100 Watts with aluminium die cast IP 66 with symmetric light distribution energy saving, environmental friendly suitable for high lighting archtechural faced all as specified and directed.
S & F in replacement PVC casing n caping ISI marked of size 20mm
S & F in replacement PVC casing n caping ISI marked of size 25mm
S & F in replacement rigid non-metallic PVC conduit of size 20mm
S & F in replacement rigid non-metallic PVC conduit of size 25 mm
S & F in replacement Flexible conduit of size 20mm
S & F in replacement Flexible conduit of size 25 mm
S & F in replacement PVC gang box suitable for 6 Amp Socket and 6 amp switch.
S & F in replacement PVC gang box suitable for 16 Amp Socket and 16 amp switch.
S & F in replacement Al cable 2 core armoured cable 6sqmm armoured cable complete all as specified and directed.
S & F in replacement Al cable 2 core armoured cable 10sqmm armoured cable complete all as specified and directed.
S & F in replacement decorative ,wall mounted bed side LED light fittings 09 Watt , brushed nikel finish fixture with opal glass diffuser suitable with 9 watt LED bulb B 22 base energy saving complete all as specified and directed.
S&F the insulation tape 10 Mtr complete all as specified and directed
S&F the insulation tape 15 Mtr complete all as specified and directed
S&F the insulation tape 25 Mtr complete all as specified and directed
S&F in replacement of unserviceable wire of size 1.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 2.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 4.0 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 1.5 Sqmm three core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
S&F in replacement of unserviceable wire of size 2.5 Sqmm three core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete all as specified and directed
Taking down recess mount light without disturbing false and disconnect electric connection & Supply and fix Driver of suitabe 2x2 ceiling light complete all as specified and directed
Taking down and refixing of the jhomer light of the specific location of with required electric connection including scaffolding etc complete all as specified and directed
Supply and fixing PVC trunking 54x105 mm size for cable tray riser to DB and DB to sub DB for sub main wiring including making good to disturbed wall surfaces complete all as specified and directed. (Note: Rate of Accessories such as elbow , bend tee , socket, junctions and flexible cover ,Coupling set/End cap/Internal corner/External corner/flat corner/T-Piece/3-D Internal corner is incl in the item rates and no extra payment will be done to the contractor.
S& F in replacement of in factory made Pantone 7541C shade powder coated distribution board SPN 4 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one SP MCB as a incomer and 3 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above DB.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 08 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 200 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 08 Nos.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 08 Nos.
M&L in factory made Pantone 7541C shade powder coated distribution board SP & N 12 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as a incomer and 10 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above DB
M&L in factory made Pantone 7541C shade powder coated distribution board SP & N 8 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as a incomer and 6 SP MCBs as outgoing complete all as specified and directed conforming to IS: 8623 along end box for above DB
M & L in factory made Pantone 7541C shade powder coated distribution board 4 way TPN DB Double door with metal double door (IP-43 protection) fabricated of CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, Neutral bar, Standard din rail,earth bar and cable ties for cable management, top and bottom removable gland plates with provn for MCB TPN and RCCB as incomer and 12 SP MCBs outgoing complete all as specified and conforming to IS :8623 along with cable end box for above DB
M & L for replacement TPN MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 .
M & L for replacement TPN MCB 100 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete conforming to IS 8828, IEC 60898.
M & L for replacement TPN MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete conforming to IS 8828, IEC 60898.
M&L in replacement of SP MCB 6 TO 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898.
M&L in replacement of MCB Single Pole & Neutral MCB 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 .
M&L in replacement of MCB Single Pole & Neutral MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898 .
M&L in replacement of MCB Single Pole & Neutral MCB 63 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828, IEC 60898.
Supply and fixing in replacement of MCCB current rating 100 Amps with thermal magnetic release, 4 pole, 415 volts AC 16 KA Ics = 50% Icu as per IEC 60947-2 ruputuring capacity all as specified and directed.
Supply and fixing in replacement of MCCB current rating 125 Amps with thermal magnetic release, 3 pole, 415 volts AC 36 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity all as specified and directed.
Supply and fixing in replacement of MCCB current rating 125 Amps with thermal magnetic release, 4 pole, 415 volts AC 36 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity all as specified and directed.
Supply and fixing in replacement of MCCB current rating 160 Amps with thermal magnetic release, 4 pole, 415 volts AC 36 KA Ics = 50% Icu as per IEC 60947-2ruputuring capacity all as specified and directed.
Taking down old U/S Bldg security/street lights/Gate lights/Bollard light/flood lights of any type any size retreived from existing site complete all as specified & directed.
Supply and fix LED gate light of 40/45W LED Postop luminaire with aluminium pressure die-cast mounting spigot & polyester powder coating in addition to a specific weathering resistance treatment, color RAL7011. Non-yellowing transparent Polycarbonate UV-protected round symmetrical diffuser with circular radial pattern for glare-free and even light distribution. High Efficiency long life LED module with efficacy of >100Lm/W, CCT 4000K, and CRI >70. Powered by built-in electronic driver with THD <10%, 4kV inbuilt surge protection, high cut-off at 325V & auto-restart, including 8hrs. protection from 440V (P2P). Incl GI Pipe 40mm dia 0.45mtr long fixed in gate pole with PCC 1:2:4 of 0.20 mtr height and size of existing gate pole. Fixture lumen efficacy >4500 Lm, IP66 (no glue), IK05, PF>0.95, Operating voltage range: 140- 277V, all as specified and directed by engineer in charge.
Supply and fixing LED building security light of 25W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed by the Engr-in-Charge.
Supply and fixing LED building security light of 35/36W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed by the Engr-in-Charge.
Supply and fixing LED building security light of 40W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed by the Engr-in-Charge.
Supply and fixing LED building security light of 60W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed by the Engr-in-Charge.
S & F in replacement street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm with nuts bolts & washers for fixing on wall complete necessary fixing arrangements on pole incl taking out old U/S bracket as directed.
Supply, install, test and commissioning in replacement factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of min size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Aluminium bus bar of 63amp----04 Nos and MCB SP 6amp-----01 No. complete fixed on wall all as specified and directed.
Material and labour for sub main wiring with 16 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 16 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, for single wire in each conduit medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
M & L for chemical Earthing complete with Copper plate 600 x 600 x 3 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.5 Mtr below the ground level connected to copper strip of 20 mm x 3 mm size by means of bolts, nuts and washers , returning & filling the pit with excavated soil mixing with charcoal 250 KG ,crystal salt 200 KG , magnesium sulphate of 100 KG and vegitable soil all around the plate up to 350 mm above from top edge of plate and balance portion filling with excavated soil in layers not exceeding 25mm thick, 25 mm galvanized iron medium grade watering pipe up to top of plate ,50 mm bore galvanized iron light grade pipe for earth strip protection , including all excavation earth work in any type of soil ,PCC 1:3:6 type C1 for chamber of internal size 300 mm X300X300mm with 120 mm thick wall and 700 mmX700mmX150 mm thick ,bed concreate,RCC 1:2:4,type B1 for precast chamber cover 50 mm thick ,reinforced with welded steel wire fabric of XPM jali (weight not less than 4.00 Kg/sqm),funnel,with wire mesh, complete al as specified and directed. Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and copper strip shall be deemed to be included in unit rate quoted by tenderer.
Taking down old U/S DB box of any size and type retreived from existing site complete all as specified & directed.
M&L for LT Panel factory made DB made out of 2mm thick MS CRCA sheet with powder coated finish complete with IP 43 protection and having 100amp MCCB 4Pole with 4 Nos copper bus bar having size 200Amp complete. Panel size 60 cm in height, 450mm in width and 250mm in depth comp-lete having 3 Nos of digital indicator lamp with 01 Nos of digital Amp meter with 3 Nos of CT of rating 100/5Amp and 01 Nos of digital voltmeter suitable for 415V, 100 Amp capacity complete complete fixed on wall with suitable fastner-04 Nos and angle iron frame incl connection of incoming and outgoing electric supply complete all as specified &directed.
M&L for disconnection of electric supply and water supply pipe line of solar water heater/ collector plates of any size from site for repair/ overhauling/ replacement of unserviceable parts incl nut and bolts with washers and refixing the same in serviceable condition after assembling , testing and re connecting the electrical and water supply line all as specified and directed by Engr-in-charge.
S&F in replacement of heating element 3 KW, suitable for solar water heater(ISI marked) all as per sample and directed by Engr-in-Charge.
Taking down old tank and M&L for replacement of old unserviceable 200 LPD hot water tank fully insulated all as specified and directed by Engr-in-Charge.
M&L for descaling of pipe line with chemical powder and liquid (4 Kg each) of solar collector plates, solar water heating tank all as directed.
M&L for replacement of old unserviceable collector glass panel with heating resistant glass panel of size 2.08 Mtr x 1.01 Mtr of thickness not less than 8 mm incl cleaning of broken glass.
M&L for replacement of old unserviceable collector panel used for solar water heater based on in directed transfer of heat of capacity 100 LPD of
M&L for welding work of rusted portion of complete set of collector panel including metal/ GI pipe where necessary.
Taking out old U/S insulated pipe and Supply & fix Hot water pipe duly insulated with glass wool and aluminium cladding galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 15 mm bore
All as above item No 114 but 20mm dia
Taking down the Geyser of any Size/Type/make from Site for repairs/overhauling/replacement of unserviceable parts including replacement of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the the Geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line all as specified and directed. Note:- Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers."
Supply and fix in replacement unserviceable heating element 2.0 KW of Geyser (ISI marked) for suitable any type/model/make all as specified and directed.
Supply and fix in replacement thermostat(ISI Marked) suitable for any type, and capacity of geyser all as specified and directed.
Supply and fix in replacement unserviceable indicating lamps red and green colour for suitable any Geysers any make all as specified and directed.
Supply and replacement of unserviceable door assembly ISI marked comprising of inlet and outlet thermostate, housing with gasket with bolts, nuts, washers, screws of packing suitable for any type and make of geyser all as specified and directed.
M & L, repairng of leakage of inner copper/steel tank of any type /capacity and make of Geyser by brazing including necessary denting, etc all as specified and directed.
Supply and replacement of unserviceable plug top 3 pin 5 Amp all as specified and directed.
Supply and replacement of unserviceable plug top 3 pin 15 Amp all as specified and directed.
Supply and replacement of unserviceable 3 core copper flexible round cable 4 Sqmm size all as specified and directed.
Supply and fix Stainless steel inner tank 25 Ltrs capacity as per existing gauge for Geysers all as specified and directed.
Supply and fix Stainless steel inner tank 35 to 50 Ltrs capacity as per existing gauge for Geysers all as specified and directed.
Supply and fix 450mm long steel connection complete & both side nut with rubber washer suitable for any capacity Geyser all as specified and directed .
Supply and fix 600mm long steel connection with both side nut & rubber washer suitable for any capacity Geyser all as specified and directed .
Taking out old U/S insulated pipe and Supply & fix Hot water pipe duly insulated with glass wool and aluminium cladding galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 15 mm bore
Taking out old U/S pipe and Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 20 mm bore
Supply and fix factory made Sheet metal enclosure for MCB 2 way all as specified and directed.
Supply and fix metallic top suitable for 20 Amp capacity plug & socket all as specified and directed.
Supply and fix metallic plug base suitable for 20 Amp capacity plug & socket all as specified and directed.
Material and labour painting of outer tank of Geyser with applying two coats of white synthetic enamel paint including writting MES No. with black paint all as specified and directed .
Supply and fix in replacement of brass Safety Valve heavy duty ISI marked of Geyser suitable for 15 mm bore of pipe all as specified and directed.
Supply and fix 450mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
Supply and fix 600mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser all as specified and directed.
Taking down Ceiling fan/Exhaust fan any size any make, sealing cable ends, dismantling blades in case of ceiling fan and removing fan and blades to E/M store yard II for repair & hanging / fixing of the same after repair and connecting up all as specified and directed.
Repair and overhauling of Ceiling fan/ Exhaust fan/ Cabin fan/ Wall mounting fan/ Table fan/ Pedastal fan of any size by oiling/ greasing and reassembling the fan with new split pin, check nut, locking nut, washer, holder clip & connector. Testing and refixing of same fan shall be made to the entire satisfaction of Engineer-in-charge. Note: Repair work will be carried out at MES workshop/at site/ Users Residence as directed. Material required (Ball bearing and Condenser) for replacement of items will be measured and paid separately.
Material and labour for replacement of ball bearing of size 6201/6202/6203 all as specified and directed.
Supply and fix Capacitor 2.5 MFd for ceiling fan of any size and exhaust fan of size 300/230mm cabin fan any Sweep all as specified and directed.
Supply and fix Capacitor 4 MFd for exhaust fan of size 450 mm/380 mm all as specified and directed.
Material and labour for replacement of unserviceable fan regulator electronic rotary step type 110 W (Switch in size 1 Module) suitable for 1200/1400 mm sweep ceiling fan all as specified and directed.
Rewinding of Ceiling fan of 1200 mm Sweep of followings: a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly. b) Replacement of defective worn out bush where required, (ball bearing, capacitor will be measured and paid separately). c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new twisted twin core flexible copper cable of size 23/0.0076 of 1 Mtr length. d) Testing of repaired fan shall be carried out in the yard of AGE E/M (East) to the entire satisfaction of the Engr-in-Charge. Note: Rewinding shall be carried out in Yard No II, Painting of Fans deemed to be include in respective Item.
All as above item no 144 but Ceiling fan of 1400 mm Sweep
All as above item no 144 but Exhaust fan 450 mm (18") to 600 mm (24") Sweep
All as above item no 144 but Exhaust fan 380 mm (15") Sweep
All as above item no144 but Exhaust fan 300 mm (12") Sweep
All as above item no 144 but Exhaust fan 230mm (9") Sweep
All as above item no 144 but Wall fan 400 mm Sweep
Supply and fixing blade set (set of three) for any type/make of ceiling fan 1200 mm Sweep all as specified and directed.
Supply and fixing blade set (set of three) for any type/make of ceiling fan 1400 mm Sweep all as Specified and directed
Supply and fixing Blade Set with frame & four legs of fan with coupling for 450 mm (18") sweep exhaust fan all as Specified and directed.
Supply and fixing Blade Set with frame & four legs of fan with coupling for 380 mm (15") Sweep exhaust fan all as Specified and directed.
Supply and fixing Blade Set with frame & four legs of fan with coupling for 300 mm (12") Sweep exhaust fan all as Specified and directed.
Supply and fixing Blade Set with frame & four legs of fan with coupling for 230 mm (9") Sweep exhaust fan all as Specified and directed.
Supply and fixing Blade set of cabin fan suitable for 400 mm sweep all as specified and directed.
Supply and fixing Twisted twin core flexible copper cable of size 23/0.0076 all as specified and directed.
M &L, Spray painting of fan with one coat of super enamel white paint after cleaning of body and blades, down rods, with detergent powder and writing MES Nos with black paint all as specified and directed.
M&L, replacement of unserviceable hanging clamp for ceiling fan of any type complete with rubber reel, split pin, bolts, nut and washer all as specified and directed.
M&L, replacement of worn out/defective roter shaft of ceiling fan, exhaust fan, cabin fan of any make and size all as specified and directed.
S&F, ceiling fan canopy set of two all as specified and directed.
Taking down U/S Ceiling fan/Exfan/wall fan of any Size/Type/Model and handover MES Store EM Yard-II for BER process.
Repair/Replacement of ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engr-in-Charge.
Repair/Replacement of ceiling fans complete with blades, down rods and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated all as specified and directed by Engr-in-Charge.
Repair/Replacement of exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM ISI marked, and making connection with twisted copper flexibelwire 23/0.076 mm all as specified and directed.
Repair/Replacement of exhaust fans single phase 230/240 Volts metalic body of size 225/230 mm sweep 1400 RPM ISI marked and making connection with twisted copper flexible wire 23/0.076 mm all as specified and directed.
Repair/Replacement of wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/min with all accessories complete all as directed by Engineer- in-charge.
Repair/Replacement of PVC air freshner 200 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed.
Repair/Replacement of PVC air freshner 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed.
Repair/Replacement of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 25 Litre to operate on 230 volt AC, vertical type, white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode, adjustable thermostat, enamel coated incology heating element 2 KW, ABS plastic body,Product warranty-2 Years, Heating element warranty-4 Years, Inner Tank warranty-7 Years, including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, complete all as specified and directed.
Repair/Replacement of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 50 Litre to operate on 230 volt AC, vertical type, white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode, adjustable thermostat, enamel coated incology heating element 2 KW, ABS plastic body,Product warranty-2 Years, Heating element warranty-4 Years, Inner Tank warranty-7 Years, including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, complete all as specified and directed.
Reapir/Replacement of Pressure pump motor, single phase, 230Volts, 50 Hz, of capacity 1.0 HP complete of pressure pumps & systems Model No-100B Pressurejet including making connections complete all as per specified and directed by the Engr-in-Charge.
Taking down/dismantling of Pressure pump of any capacity from site and Rewinding of Pressure pump and other minor repairs incl sensor etc, removing old wire & winding with copper wire and complete overhauiling of pump etc all as specified and directed.
Taking down U/S chimney and S&F of electric chimney single phase 230 Volt including push control, baffle filter, metal blower, min suction power 800 Cum/Hr, black powder coated with min size L-90 cm and S-60cm and all accessories complete all as specified and directed.
M/s A.K Construction (BID ID -3088619)
ms singh construction (BID ID -3089917)
M/s Vatsh Raj and co (BID ID -3089471)
Sanjay Traders (BID ID -3089853)
M/S S.B. Singh and Sons (BID ID -3090127)
M/S CLASSIC ENTERPRISES (BID ID -3089821)
M/s Singh enterprises (BID ID -3089806)
M/s J P Traders (BID ID -3090376)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .