Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.7 L+₹2.8 L (14.3%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹25.5 L+₹5.7 L (28.5%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹27.7 L+₹7.8 L (39.1%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
15 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF SUMMER AND COOLING APPLIANCES AT COD INSIDE UNDER GE (I) KANPUR
2024_MES_680170_1
GE(I)/KAN/T-59 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹60,000
Yes
26 Dec 2024
18 Oct 2024
22 Nov 2024
18 Oct 2024
15 Nov 2024
1 Nov 2024
Amount
Repair, maint and making the continuity of electric supply after rectifying the defects of the water cooler, refrigrator, ACs etc. including providioning of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any other accessories found unserviceable shall be replaced & paid seprately under respective items of this Sch. (ii) Contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectifing the defact on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor.
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening by using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately if required under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. (iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor
S&F in replacement of cooling coil of window type AC any cap up to 2 ton complete all as specified and directed.
S&F in replacement of front grill of window AC suitable for 1.5/2 ton cap as per sample complete all as specified and directed.
S&F in replacement of rotary type sealed compressor of window AC 1.5/2 Ton cap as per sample complete all as specified and directed.
S&F in replacement of Air blower moter as per sample suitable for window/split type AC of 1.5/2 Ton capacity single phase as per sample complete all as specified and directed.
S&F in replacement of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd as per sample complete all as specified and directed.
S&F in replacement of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton as per sample complete all as specified and directed.
S&F in replacement of thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity complete all as specified and directed.
S&F in replacement of condenser fan blade suitable for window/split type AC of any make & capacity complete all as specified and directed.
M&L for minor denting work to window type air conditioners of 1.5 / 2 Ton capacity including applying spary painting with a coat of synthetic enamel paint of requried shade complete all as specified and directed.
Disconnecting electrically and opening the cover of split AC 1.5/2 ton cap inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as specified and directed.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the Split type AC of 1.5 / 2 Ton capacity and fixing only new spares as per model / capacity including necessary welding with existing refrigerant pipe, charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.
S&F in replacement of sealed compressor, rotary type, of any make as per sample suitable for split type AC of 1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type complete all as specified and directed.
S&F in replacement of discharge grill of outdoor unit of any size and type for split AC’s complete all as specified and directed.
S&F in replacement of defective remote control hand set with "AAA" batteries for window/split type AC's, of any model / make complete all as specified and directed.
S&F in replacement of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed.
Supply and fixing of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed.
Supply and fixing of annealed copper tube as per existing and site requirement complete all as specified and directed.
Supply and fixing of condenser / cooling coil for air conditioner of suitable size complete as per site requirement and as directed.
Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remort complete all as specified and directed.
M&L for fixing/installation of split AC inner/outer or both unit as received from item No 59 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion all as spfd and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required complete all as specified and directed.
S&F in replacement of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed.
S&F in replacement of foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed.
S&F in replacement of Main control circuit (PCB) as per sample for window AC's, of any model / make complete all as specified and directed.
S&F in replacement of Main control circuit (PCB) for invertor type AC as per sample for split type AC's, of any model / make complete all as specified and directed.
S&F in replacement of Sensor as per sample for window/split type AC's, of any model / make complete all as specified and directed.
S&F in replacement of PVC flexible drain pipe 15mm to 25mm dia clamped with suitable PVC clamps fasten by SS nails on one end complete all as specified and directed.
M & L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR cap at site / contractor's workshop including any welding / repair work reqd at site complete all as specified and as directed.
Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit medium grade of size 20/25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends for drain of AC complete all as specified and directed.
Supply and filling refrigerant R-22/R134a/R410 environment friendly refrigerants as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and as directed. Note : Refrigerant gas shall be supplied and paid separately under item No 95 herein after
Disconnecting, dismantling and taking out old u/s voltage stabilizer of cap 2 to 5 kVA and refixing the same in same/other location after repair incl all minor parts i.e wire, nut, bolt and washers etc complete all as specified and directed. Note : Spare parts will be measured and paid seperately under respactive items.
S&F in replacement of Main relay of voltage stabilizer 3 to 5 kVA as per sample complete all as specified and directed.
S&F in replacement of Main control circuit (PCB) of voltage stabilizer 3 to 5 kVA as per sample complete all as specified and directed.
S&F in replacement of replacement of sensor transformer of voltage stabilizer 3 to 5 kVA as per sample complete all as specified and directed.
S&F in replacement of voltmeter of voltage stabilizer 3 to 5 kVA as per sample complete all as specified and directed.
S&F in replacement of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 kVA as per sample complete all as specified and directed.
S&F in replacement of transformer 3 to 5 kVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed.
Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.
Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrs for repair complete all as specified and directed.
M&L for fixing/installation of water cooler any type of cap 40/ 80/ 150 ltrs and making all electrical/water connection and testing after repair complete all as specified and directed.
S&F in replacement in replacement of sealed compressor as per sample suitable for water cooler of capacity up to 40 / 80/ 150 Ltrs as per sample complete all as specified and directed.
S&F in replacement in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd as per sample for water cooler complete all as specified and directed.
S&F in replacement in replacement of Running capacitor 10-30 Mfd as per sample for water coller/ window ac/ split ac/refrigerator complete all as specified and directed.
S&F in replacement in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs as per sample complete all as specified and directed.
S&F in replacement in replacement of Starting relay of water cooler as per compressor requirement complete all as specified and directed.
S&F in replacement in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement complete all as specified and directed.
S&F in replacement in replacement of Over load protector of water cooler as per sample suitable for water coolers complete all as specified and directed.
S&F in replacement of PVC flexible pipe transparent 15 / 20 mm dia (as per sample) for water cooler complete all as specified and directed.
S&F in replacement of Brass chromium plated Push cock heavy duty universal type, suitable for water cooler of capacity up to 150 ltrs complete all as specified and directed.
S&F in replacement of PVC float valve 15 / 20 mm dia with rod & ball for water cooler. Make: Prayag or equivalent complete all as specified and directed.
S&F in replacement of Liquid line filter one way / two way for water cooler complete all as specified and directed.
S&F in replacement of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed.
S & F in replacdment of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed.
S&F in replacement for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed.
S&F in replacement for minor denting work and applying a coat of spray painting to water cooler with synthetic enamel paint after proper scraping of old rusted painted surface complete all as specified and directed.
M&L for single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one MCB 20 Amps, 240 Volts complete all as specified and directed.
S&F in replacement of plug top 15 Amps complete all as specified and directed.
M & L in repair for filling up complete cavity nearby indoor unit through the wall completey vermin/rat proof from outside using PU foam spray all purpose cosmos MRO preferabbly off white in color & 750 mm bottle complete all as specified and directed.
S&F in replacement for water leakage tray from indoor unit any type & any make, height upto 15 ft complete all as specified and directed.
Repair, maint and making the continuity of electric supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, etc. including provisioning of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any other accessories found unserviceable shall be replaced & paid seprately under respective items of this Sch. (ii) Contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectifing the defact on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor.
Disconneting & taking down and strip opening of ceiling fan up to 1200/1400 mm sweep for servicing, strip opening of fan including servicing, cleaning, oiling and greasing amd replacing nuts, bots, rubber real and quarter pin complete at site. Re-assembling and refixing to the same/other location and testing complete after servicing and fixing for smooth and noise free operation of ceiling fans 48"/56" (1200mm / 1400mm) sweep complete all as specified and directed.
Assembling the fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired complete with all accessories complete all as specified and directed.
Rewinding of ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire complete all as specified and directed.
S&F in repair fan capacitor AC 440 volts 4 mfd 50HZ complete all as specified and directed.
All as per srl item No 67 above but 2.5 mfd and complete all as specified and directed.
All as per srl item No 67 above but 3.15 mfd and complete all as specified and directed.
S&F in repair of gun metal bush suitable for any size / model / type of fans complete all as specified & directed.
S&F in repair alignment grinding to shaft, remetalling & finishing complete all as specified and directed.
S&F in repair ceiling fan shaft of standard size including taking out old shaft, complete all as specified and directed.
Supply and fixing in replacement fan regulator electronic, 80 Watt 5 step hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed.
Disconneting & taking down exhaust fan any type/make and size for servicing, strip opening of exhaust fan including servicing, cleaning kerosen oil/thinner, oiling and greasing and complete at site. Re-assembling and refixing to the same/other location and testing complete after servicing and fixing for smooth and noise free operation of exhaust fan complete all as specified and directed.
Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair re-assembling, re-fixing after replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete all as specified and directed.
Disconnecting electrically, taking down existing exhaust fan any type and capacity with due care, dismantling blades and removing for repair with all accessories complete all as specified and directed.
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete all as specified and directed.
S&F in repair of ball bearing any No suitable for ceiling fan upto 1400mm sweep complete all as specified and directed.
S&F in repair of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete all as specified and directed.
S&F in repair of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep, complete all as specified and directed.
S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan complete all as specified and directed.
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long complete all as specified and directed.
All as per item No 82 above but of size 1 Mtrs long and complete all as specified and directed.
All as per item No 82 above but of size 1.5 Mtrs long and complete all as specified and directed.
All as per item No 82 above but of size 2 Mtrs long and complete all as specified and directed.
All as per item No 82 above but of size 3 Mtrs long and complete all as specified and directed.
Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site complete all as specified and directed.
S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers all as per sample complete all as specified & directed.
M & L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified and directed.
M&L for single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one MCB 20 Amps, 240 Volts complete all as specified and directed.
S&F repair of ceiling fan clamps for fixing with fan rod incd nut, bolt, lock pin, rubber real complete all as specified & directed.
Disconnecting, dismantling and taking out old u/s storage type water heater geyser of cap 25/35 Ltrs from wall for repair at site complete all as specified and directed.
S&F in repair of PVC flexible connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new as per sample with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply as per sample complete all as specified and directed.
M&L for disconnecting, dismantling old u/s heating element of cap 2 kW and replaced with new and testing on completion as per sample complete all as specified and directed.
All as per item No 95 above but heating element of size 1.5 kW complete all as specified and directed.
M&L for dismantling old u/s syphon assembly of geyser 25 to 50 ltrs ltr capacity and replaced with new stainless steel syphon assy complete with thermostate, heating element 2 KW and rubber gasket as per sample complete all as specified and directed.
S&F inreplacement of unsv stainless steel inner tank suitable for 25/35 Ltr storage water heater/geyser complete as per existing complete all as specified and directed.
S&F inreplacement of glass wool as existing suitable for 25/35 Ltr storage water heater/geyser complete as per existing complete all as specified and directed.
S&F in repair of pressure release valve with inlet coupling of superior quality as approved complete complete all as specified and directed.
S&F in repair of plug top 15 Amps complete all as specified and directed.
S&F in replacement stop valves, cromium plate cast copper alloy,screwed down,high pressure,with crutch or angular type, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F in replacement of PCB for BLDC fan any type or make as per sample all as specified and directed.
S & F in replacement of remote with battery of suitable cap for BLDC fan any type or make as per sample all as specified and directed.
M & L in repair for taking down/out desert cooler from exsting place and removing the old paint from the body of desert cooler and applying paint external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed.
M & L in repair of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler as per sample complete with jalli, wood wool pad , fastners painting with two coat of synthetic enamel paint over a coat of primer etc complete all as specified and directed.
Supply and fixing in repair of water lifting pump submersible type, 220 -240 Volts 50 HZ and head not less than 1.5 mtr as per sample complete all as specified and directed.
Supply & fixing in repair of kit fan motor of desert cooler as per sample, 230 volts complete with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed.
S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed.
M & L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto 450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed
S & F in repair of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed. Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint. Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work. Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.
M&L in repair for dimentling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as spfd and directed.
Disconnecting, dismantling old u/s indicator lamps and replaced with new complete all as specified and directed.
Dismantling old PVC Water distributor four way and refixing with new as per sample and complete all as specified and directed.
S&F in repair of existing UNSV desert cooler blade as per sample and fix in the desert cooler complete all as specified and directed.
M/S G S Gupta and Sons (BID ID -3165754)
S B ENTERPRISES (BID ID -3160471)
PAWAN COOL CORPORATION (BID ID -3162662)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .