Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹23.4 L+₹3.8 L (19.1%)Rejected-Finance | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹26.6 L+₹6.9 L (35.1%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹27.0 L+₹7.4 L (37.5%)Rejected-Finance | L4 | Rejected-Finance Not being L1 bidder |
| Sl No | Description | Qty | Unit | verma enterprises L1 | M/s S.G. BUILDERS L2 | MOHIT ENTERPRISES L3 | SABHARWAL CONSTRUCTION CO. L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Attending complaints for checking and replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repair(s) such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/ internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed.
Notes :- 1. Contractor shall provide adequate numbers of tradesmen (electrician) alongwith helper to attend the complaints all the above areas in all working days including holiday and sunday.
2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints.
3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints.
4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due.
5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost.
6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill.
7. This item is applicable only where no store is required. | 9,000 | Per Complaint | 29 ₹2,61,000 | 27 ₹2,43,000 Lowest | 49.99 ₹4,49,910 | 57 ₹5,13,000 |
| 2.00 | S&F in repair of switch piano flush type 6 Amps SP one way complete all as specified and as directed. | 650 | Each | 19 ₹12,350 Lowest | 22 ₹14,300 | 44 ₹28,600 | 30 ₹19,500 |
| 3.00 | S&F in repair of switch piano flush type 6 Amps SP 2-way complete all as specified and as directed. | 20 | Each | 29 ₹580 | 25 ₹500 Lowest | 44 ₹880 | 45 ₹900 |
| 4.00 | S&F in repair bell push, flush type 6 Amps complete all as specified and as directed. | 25 | Each | 29 ₹725 | 25 ₹625 Lowest | 44 ₹1,100 | 35 ₹875 |
| 5.00 | S&F in repair of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and as directed. | 500 | Each | 39 ₹19,500 | 34 ₹17,000 Lowest | 55 ₹27,500 | 45 ₹22,500 |
| 6.00 | S&F in repair of switch piano type 16 Amps SP one way complete all as specified and as directed. | 300 | Each | 89 ₹26,700 | 75 ₹22,500 | 66 ₹19,800 | 55 ₹16,500 Lowest |
| 7.00 | S&F in repair of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed. | 200 | Each | 89 ₹17,800 | 75 ₹15,000 | 55 ₹11,000 Lowest | 55 ₹11,000 Lowest |
| 8.00 | S&F in repair of lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed. | 250 | Each | 29 ₹7,250 Lowest | 29 ₹7,250 Lowest | 33 ₹8,250 | 70 ₹17,500 |
| 9.00 | S&F in repair of bell Ding dong type 230 volts single phase complete all as specified and as directed. | 25 | Each | 119 ₹2,975 | 125 ₹3,125 | 99 ₹2,475 Lowest | 121 ₹3,025 |
| 10.00 | S&F in repair ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and as directed. | 150 | Each | 29 ₹4,350 | 15 ₹2,250 Lowest | 33 ₹4,950 | 35 ₹5,250 |
Tender Value
₹47.8 L
EMD Value
₹95,600
Closing Date
11 Dec 2025, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIR/REPLACEMENT OF UNSERVICEABLE WIRING, MCBs, MCCBs, DBs, LIGHTs, SUMMER AND WINTER APPLIANCES INCLUDING ATTENDING DAY TO DAY PETTY COMPLAINTS AT KHANPUR TRANSIT CAMP, DUNDAHERA MIL STN, MANESAR ARMY CAMP, INDUBINOLA UNDER AGE E/M
2025_MES_740711_1
GE/TOKEN-81/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹95,600
Yes
17 Jan 2026
20 Nov 2025
13 Dec 2025
20 Nov 2025
11 Dec 2025
4 Dec 2025
Amount
Attending complaints for checking and replacing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repair(s) such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/ internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed. Notes :- 1. Contractor shall provide adequate numbers of tradesmen (electrician) alongwith helper to attend the complaints all the above areas in all working days including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. This item is applicable only where no store is required.
S&F in repair of switch piano flush type 6 Amps SP one way complete all as specified and as directed.
S&F in repair of switch piano flush type 6 Amps SP 2-way complete all as specified and as directed.
S&F in repair bell push, flush type 6 Amps complete all as specified and as directed.
S&F in repair of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and as directed.
S&F in repair of switch piano type 16 Amps SP one way complete all as specified and as directed.
S&F in repair of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed.
S&F in repair of lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repair of bell Ding dong type 230 volts single phase complete all as specified and as directed.
S&F in repair ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and as directed.
S&F in repair of fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
S&F in repair of fan condenser 2.5 Mfd complete all as specified and as directed.
S&F in repair of fan condenser 3.15 Mfd complete all as specified and as directed.
S&F in repair LED Bulb 9 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings complete all as specified and as directed.
S&F in repair decorative wall-mounted light fitting, body made of high-grade engineering plastic, suitable for holding LED lamp up to 9 Watt (B22 base), with IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. The fitting shall be connected with 1.5 sqmm FRLS, PVC insulated, copper conductor single-core cable including earthing as required from ceiling rose/DB, complete all as specified and directed.
S&F in repair LED bulkhead light fitting, 10 Watt, white colour, housing made of high-grade flame-retardant engineering plastic with clear prismatic diffuser, suitable for wall or ceiling surface mounting. The fitting will be provided with replaceable LED lamp (cool white) and include all required mounting accessories.Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose, complete all as specified and directed.
Supply and fix in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. ≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). complete all as specified and as directed.
Supply and fix in repair of LED surface mounted Batten light 10 W 2 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed.
S&F in repair 45 Watt street light (Building security light) LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90C), complete all as specified and as directed.
S&F in repair Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer complete all as specified and as directed.
S&F in repair of PVC casing caping of size 25 mm with suitable size of nails for fixing PVC casing caping, in repairs of batten/surface wiring complete, complete all as specified and as directed.
M&L for submain wiring of two runs of 4 Sqmm size for main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and as directed. Note (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and as directed. Note (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for submain wiring of two runs of 10 Sqmm size for main cable and one run of 10 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and as directed. Note (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Taking down of ceiling fan/ exhaust fan/ wall fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete. Note:- Rewinding will be measured and paid under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, shaft and ball bearing where ever required complete all as specified and as directed. Note: Ball bearing and shaft will be measured and paid separately in respective items.
All as per srl item No 26.00 here-in-before but exhaust fan/wall fan upto 450 mm sweep.
S&F in replacement Gun metal bush for fans complete all as specified and as directed.
S&F in replacement Ball bearing of suitable size & model for ceiling/Exhaust fan complete all as specified and as directed.
S&F in replacement of exhaust fan iron blades for size 225/300/450 mm sweep complete all as specified and as directed.
S&F in replacement motor of exhaust/fresh air fans of 225/300 mm swipe size, heavy duty, duly painted with one coat of paint of suitable colour complete all as specified and as directed.
S&F in replacement motor of exhaust/fresh air fans of 450 mm swipe size, heavy duty, duly painted with one coat of paint of suitable colour complete all as specified and as directed.
S&F in replacement metal frame of exhaust/fresh air fans of 225/300/450 mm swipe size, heavy duty duly painted with one coat of synthetic enamel paint of suitable colour complete all as specified and as directed.
S&F in replacement Exhaust fan Louvers 225/300/450 mm Size, MS, including taking out old louvers complete all as specified and as directed.
S&F in replacement ceiling fan holder hook with rubber real suitable for size 1200/1400 mm ceiling fan as per sample complete all as specified and as directed.
S&F in repair PVC canopy for ceiling fan of size 1200/1400 mm as per sample complete all as specified and as directed.
S&F in repair plug top 20 Amps complete all as specified and as directed.
S&F in repair single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 20 Amps as per site requirement of existing type complete all as specified and as directed.
S&F in replacement MCB Distribution Board (DB), SPN, 4 Way, double door type, IP43 protection, flush mounting, factory-fabricated sheet steel enclosure duly powder coated, complete with busbar, neutral link, earth bar and provision for MCBs and conforming to IS:13032/IEC 61439, including necessary fixing arrangements, complete all as specified and directed.
S&F in replacement MCB Distribution Board (DB), SPN, 8 Way, double door type, IP43 protection, flush mounting, factory-fabricated sheet steel enclosure duly powder coated, complete with busbar, neutral link, earth bar and provision for MCBs and conforming to IS:13032/IEC 61439, including necessary fixing arrangements, complete all as specified and directed.
S&F in replacement MCCB, 3 Pole, 415 Volts, adjustable type, rated current 100 Amps, breaking capacity 16 kA (Ics/Icu), thermal-magnetic release, suitable for mounting in existing panel/DB and conforming to IS/IEC 60947-2, complete all as specified and directed.
S&F in replacement MCCB, 3 Pole, 415 Volts, adjustable type, rated current 125 Amps, breaking capacity 16 kA (Ics/Icu), thermal-magnetic release, suitable for mounting in existing panel/DB and conforming to IS/IEC 60947-2, complete all as specified and directed.
S&F in replacement MCCB, 3 Pole, 250 Amps, 415 Volts, with breaking capacity 36 kA (Ics/Icu), thermal-magnetic release, suitable for mounting in existing panel/DB and conforming to IS/IEC 60947-2, complete all as specified and directed
S&F in repair Panel light 2x2 ft. 36 Watt of Powder coated die cast / Extruded aluminium Body (Thickness >1.20 mm) and constructionas per IS : 10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should bebelow 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). complete all as specified and as directed.
S&F in repair for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
S&F in repair for MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
S&F in repair for MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
S&F in repair MCB TPN/ Isolator 4P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and as directed.
S&F in repair MCB TP 3 Pole from 40 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring with multi stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through suitable existing PVC conduit including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm multi stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good the disturbed surfaces of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour wash/white wash as the existing finishes etc. complete all as specified and as directed. Note :- 1. New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates. 2. At roof slab, where there is burnt/blockage in the existing conduit, wiring will be done through new PVC conduit and rates are inclusive in above quoted item. 3. The rate is inclusive for if old wiring is normal wiring, then new wiring for modular point wiring to be done.
All as per Srl item No. 51 here-in-before, but for One light / fan/bell point controlled by one switch SP, one way, 230 volts.
All as per Srl item No. 51 here-in-before, but for One 3 pin socket outlet 5/6 Amps on same board.
All as per Srl item No. 51 here-in-before, but for One socket outlet 5/6 Amps on independent board.
All as per Srl item No. 51 here-in-before, but for One power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
S&F Switch modular type, 1 Module, 6 Amps one way complete all as specified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 6 Amp complete all as specified and as directed.
S&F Switch modular type 1M, 16 Amp with red indication light complete all as specified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 16 Amp complete all as specified and as directed.
S&F in replacement Distribution Board, vertical type, Triple Pole and Neutral (TPN), 4 Way, double door, suitable for fixing MCCB up to 125 Amps as incomer and MCBs as outgoing feeders, factory-fabricated sheet steel enclosure with metal door, duly powder coated, IP43 protection, complete with busbar, neutral link, earth bar and necessary connections and conforming to IS:13032/IEC 61439, complete all as specified and directed.
S&F in repair MS fastner bolt 8mm dia and 100 mm (Min.) for fixing Exhaust fan/Bldg security light etc with nut and washer complete all as specified and as directed.
Taking down geyser 25/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and as directed.
S&F in repair heating element 1.5 KW for any make of geyser of 25 litres capacity as per sample complete all as specified and as directed.
S&F in repair heating element 2 KW for any make of geyser of 50 litres capacity as per sample complete all as specified and as directed.
S&F in repair thermostat for 25/50 ltrs capacity geysers complete all as specified and as directed.
S&F in repair indicating lamp round / flat type as required in replacement for geyser 25/ 50 litres capacity as per sample complete all as specified and as directed.
S&F in repair safety valve ISI marked for geyser 25/50 litres capacity in replacement as per sample complete all as specified and as directed.
S&F in repair safety plug for geyser 25/50 litres capacity in replacement as per sample complete all as specified and as directed.
S&F in repair PVC connection with brass nipple 15 mm x 450 mm long in replacement for geyser 25/50 ltrs capacity as per sample complete all as specified and directed.
S&F in repair base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket in replacement for any make of geyser of 25 litres cap as per sample complete all as specified and as directed.
S&F in repair base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket in replacement for any make of geyser of 50 litres cap as per sample complete all as specified and as directed.
S&F in repair 25 Ltr inner stainless steel tank suitable for 25 Ltr storage water heater complete all as specified and as directed.
S&F in repair 50 Ltr inner stainless steel tank suitable for 50 Ltr storage water heater complete all as specified and as directed.
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25/50 ltrs capacity of any make and make the shell water tight including testing complete all as specified and as directed. Note:-Taking down, de-scaling, replacement of rubber gasket and any minior repair involved will be mesured and paid seperatly.
S&F in repair Rubber gasket for water heater storage type of any capacity fixed and suitable as per the existing, complete all as specified and as directed.
M&L for Top & Bottom cover body suitable for 25 Ltrs storage water storage heater made of MS sheet complete as per site requirement complete all as specified and as directed.
M&L for Top & Bottom cover body suitable for 50 Ltrs storage water storage heater made of MS sheet complete as per site requirement complete all as specified and as directed.
Comprehensive maintenance of desert cooler of any type and any make, fixed at different location at Dundahera mil stn and manesar army camp including taking down, cleaning all dirt, dust, oiling of motor and pump, checking of parts, including replacement of nuts bolt, screw etc and preparation of the desert cooler body and tank by scrubbing the old paint and spray painting with two coats of synthetic enamel paint complete all as specified and as directed. Note : Supply and replacement of parts shall be measured and paid separately.
S&F in repair 18 inch mounting frame including 3 sets of side Panels made with 2mm thick MS sheet as per existing size/Model and as per sample for desert cooler complete all as specified and as directed.
S&F in repair blade of 18 inch sweep suitable for desert coolers complete all as specified and as directed.
S&F in repair operating kit for 18 inch desert cooler complete all as specified and as directed.
S&F in repair fan mounting bracket set as required for desert cooler complete all as specified and as directed.
S&F in repair water lifting pump, single phase suitable for desert coolers complete all as specified and as directed.
S&F in repair cooler fan motor 1/7 HP or any Hp as per site requirement 230 volt,50Hz cycles AC complete all as specified and as directed.
S&F in repair capacitor, 4 mfd rating complete all as specified and as directed.
S&F in repair wood wool pad (set of 3) suitable for 18 inch sweep desert cooler of good quality complete all as specified and as directed.
M&L for refilling of refrigerant gas (R-22 type) in Air Conditioner/Refrigerator/Water Cooler, including necessary arrangements for gas charging, leak testing, pressure testing and ensuring proper cooling performance, complete all as specified and directed.
M&L for refilling of refrigerant gas (R-134a type) in 320 Ltr capacity Deep Freezer, including necessary arrangements for gas charging, leak detection, pressure testing and ensuring proper cooling performance, complete all as specified and directed.
S&F in repair compressor suitable for Deep Freezer of 320 Ltr capacity, hermetically sealed type, including necessary connections, dehydration, gas charging and testing for proper functioning, complete all as specified and directed.
M/s S.G. BUILDERS (BID ID -3493013)
MOHIT ENTERPRISES (BID ID -3495335)
SABHARWAL CONSTRUCTION CO. (BID ID -3495570)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.76 MB
TenderpagesT81.pdf
Tender Documents • 0.81 MB
BOQ_829422.xls
BOQ • 2.72 MB
SCHOFCREDITT81.pdf
Additional Documents • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .