| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.0 L+₹11.9 L (69.8%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
10 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS
GE 881 EWS C/o 56 APO
GE/PNH-22/2020-21
2020_MES_381497_1
GE/PNH-22/2020-21
Open Tender
Civil Works
Lump-sum
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹30,000
Yes
1 Jun 2021
28 Sept 2020
11 Nov 2020
28 Sept 2020
10 Nov 2020
21 Oct 2020
60 days
Amount
Schedule 'A' Part-I (Building Work) JOB NO. SHQ/POONCH/Minor-06/2020-21)(Toilet block)
Total amount of Sch 'A' Part-I (Building work) brought forward from srl page No-19.
Schedule 'A' Part-II (Internal Water Supply works) JOB NO. SHQ/POONCH/Minor-06/2020-21) (Toilet block)
Total amount of Sch 'A' Part-II(Internal Water Supply works) brought forward from srl page No-20
Schedule 'A' Part-III (Plumbing works) SHQ/POONCH/Minor-06/2020-21) (Toilet block)
Total amount of Sch 'A' Part-III(Plumbing works) brought forward from srl page No-21
Schedule 'A' Part-IV (Internal Electrification works) JOB NO. SHQ/POONCH/Minor-06/2020-21) (Toilet block)
Total amount of Sch 'A' Part-IV (Internal Electrification works) brought forward from srl page No-23
Schedule 'A'Part-V (Sewage Disposal Works) JOB NO. SHQ/POONCH/Minor-06/2020-21)
Total amount of Sch 'A' Part-V(Sewage Disposal WorKs) brought forward from srl page No-25
Schedule 'A'Part-VI(External water supply Works) JOB NO. SHQ/POONCH/Minor-06/2020-21) (Toilet block)
Total amount of Sch 'A' Part-VI(External water supply Works) brought forward from srl page No-26
Schedule 'A'Part-VII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.(JOB NO. SHQ/POONCH/REV-03/2020-21, SHQ/POONCH/REV-06/2020-21, SHQ/POONCH/SR/BLDG/ 02/2020-21 & SHQ/POONCH/MINOR/06/2020-21.
B&R Portion:- Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets all as specified & directed.
6mm thick plywood (05 No of Ply) grade BWR type BB fixed with nails to timber frame work as in ceiling, complete all as specified.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified.
Machine pressed chequered cement concrete tiles with chemical resistant coating of size 300x30x 25mm thick laid in floors / path etc. set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade of tiles over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
50mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Machine cut kota stone slab flooring 18-20mm thick as in floor laid over & including 20mm thick screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
Machine cut Kota stone 18-20mm thick as in riser of steps, skirting, dado and pillar fixed over & including cement plaster 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the kota stone including rubbing and mirror polishing, complete all as specified.
15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified.
0.63mm thick galvanised corrugated mild steel sheeting with grade of Zinc coating of 275 gms/Sqm with two corrugation side lap and at least 150 mm end lap , fixed with L or J type or cranked hook bolts, in roof, walls etc, complete, all as specified.
Description all as per item No. 10 above, but except sheeting, complete all as specified and directed.
0.80 mm thick plain galvanised mild steel sheeting with grade of Zinc coating of 275 gms/Sqm with two corrugation side lap and at least 150 mm end lap , fixed with L or J type or cranked hook bolts, in roof, walls etc, complete, all as specified.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
20mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
20mm thick rendering in CM 1:4 on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
Preparation of new plaster surface of wall including cornices pilaster etc, and applying two coats of oil bound distemper over and including chalk whiting primer, complete as specified and directed.
Preparation of old plastered or un plastered wall surfaces including washing, scrubbing down and stopping of distermperd surfaces and applying one coat of oil bound distemper, complete all as specified.
Preparation of newly plastered wall surfaces and applying two coats of cement base paint, complete all as specified.
Dismantling of timber scantling 40sqcm and over in section, as in any position, complete all as specified.
2nd class soft wood as in scantling, clean sawn fixed in framed work, complete all as specified.
All as per description of Ser itemNo.7.20 above but except wood.
Taking down shutters of any description not exceeding 1sqm each and refixing in the same opening, complete all as specified and directed.
Taking down shutters of any description exceeding 1sqm and not exceeding 2sqm each and refixing in the same opening, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each, complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5Sqm each, complete all as specified.
Factory made Pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x25x3mm thick angle iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and holdfasts complete all as specified & directed.
2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified.
35mm thick 2nd class hard wood plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and directed.
30mm thick 2nd class hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (divided into square with sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b) supplied and fitted to chowkats complete, all as specified.
Plain fillets, rectangular or triangular in section clean sawn, secured with nails or brads sectional area exc 3Sqcm & nexc 6Sqcm, second class soft wood (Kail) complete all as specified.
Hacking out old broken glass n.exc 0.5sqm area each (any thickness, size, quality or description) from metal / wooden frames or stone/ concrete, glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips, complete, all as specified and directed.
Sheet glass ordinary quality, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified.
Mild steel butt hinges, medium weight, cold rolled,75mm long, complete all as specified.
300mm long aluminium alloy anodized sliding door with haps, staple (bolt type) and fixing clips of sheets, cast or extrusted sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified.
Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section of size 75mm and fixed, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised of size 100mm and fixed, complete all as specified and directed.
140mm Foor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor, complete all as specified and directed.
Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of Ist quality over a coat of pink primer,complete, all as specified.
Preparation of old painted wooden or wood based surfaces of any description not otherwise described, over 10cm width or girth including knotting and stopping as required and applying one coat of synthetic enamel paint, complete all as specified.
Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Preparation of old painted steel surfaces of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
Cutting holes in stone walls exc half brick wall & nexc one brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, complete all as specified.
Mild steel FI as in hold fasts, wind tie for roof and similar small articles fixed, conforming Fe-290 Gde E-165, complete all as specified and directed.
Mild steel work in chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165, complete all as specified.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Walling of random rubble stone masonry uncoursed , well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified.
All as per ser Item No 7.48 above but except stone, complete all specified and directed.
Cement concrete (1:2:4) using 20mm graded stone aggregate as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforement cut as required to facilitate demolition), complete all as directed by Engineer-in-Charge.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
RCC 1:2:4 type B-I (Nominal mix) using 20mm graded crushed stone aggregate as in chajja and the like, complete all as specified and directed.
Keyed pointing to random or polygonal rubble, uncoursed or brought upto course in CM 1:3, complete all as specified and as directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc. not exceeding 10sqm on plan and not exceeding in depth and getting out in any type of soil, complete all as specified.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete, complete all as specified.
Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:6, complete all as specified.
Bricks, sub class B, laid on edge in floors; old size bricks bedded & jointed in cement mortar 1:6 and pointed in cement mortar 1:6, complete all as specified.
Plain cement Concrete 1:3:6 type-B1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts plinth band, bed blocks and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified.
Plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement complete all as specified.
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto all as per description of item No-7.62 above, complete all as specified.
25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in floor finishing surface even and fair to receive floor finishes, ,complete all as specified.
E&M Portion:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs of any type / description etc and making good disturbed surfaces of wall,ceiling, complete all as specifiecd and directed.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc. One light/fan point controlled by one, one way switch 6 Amp complete all as specified and as directed for the following :--
Description all as per item No-7.67 above but for One 3 pin socket outlet 6 amp on same board complete all as specified.
Description all as per srl item No 7.67 here in before but for One 3 pin socket outlet 6 amp independent complete all as specified.
Description all as per srl item No 7.67 here in before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 1.5 sqmm as in continuous earth wire.
Ceiling rose, 3 phase PVC/poly carbonate, insulated body, compete all as specified. Make:-Havells/Anchor/Cona
Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified. Make:-Havells/Anchor/Cona
Switch socket multipurpose combination 2 in 1, 5 pin, 5 Amp flush type universal,complete all as specifed.
Switch socket multipurpose combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal,complete all as specifed.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified. Make:-Havells/Anchor/Cona
Tube light fitting with universal batten suitable for T8 LED lamps LED 20W tube Rod with end cap complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 20LED tube rod 4 feet long (Double Side Connection) fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:-REGALBATTENT8UPTO1X22WSSBSWH for fittings & CRYSTAL 1213T8DSTL20WLED865SGLASS for LED tube rod or Equivalent cat part of make as specified in Appx 'F' here in after. Note :- The LED batten and LED tube rod shall be of same make.
LED street light fittings 30 Watt made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with hosing with all accessories pre wired and making connection with copper flexible cable of suitable size to light fitting fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:ENDURAPEARLSL30WLED757SASYTOPCMP or Equivalent cat part of make as specified in Appx 'F' here in after.
Sheet metal enclosure for DBs when MCB to be used TPN 415 volts AC 50Hz, double door built in bus bars, complete all as specified and directed, complete all as specified. Make Havells cat part No- DHDQTHCSRW04 or equivalent in make Legrand / Siemens / Schneider/ C&S
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning fixed in repairs, complete all as specified. Make:- Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make of Legrand / Indoasian / L&T
MCB triple pole & neutral 63 amps 415 volts 10 KA 'C' series fixed, complete all as specified. Make:-Havells cat part No-DHMGCTNF063 or equivalent cat part of make-Legrand / INDOASIAN / L&T
MCB single pole & neutral 40 amps 240 volts 10 KA 'C' series fixed, complete all as specified. Make:-Havells cat part No-DHMGCSNF040 or equivalent cat part of make-Legrand / INDOASIAN / L&T
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or equivalent cat part of make-Legrand / INDOASIAN / L&T
Wiring for circuit/submain wiring in casing caping along with earth wire with 2x2.5Sqmm+1x1.5Sqmm of FR PVC insulated copper conductor single core cable (ISI marked) including taking down old wiring, complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 8mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion, complete all as specified and directed.
LED lamp ADORE 10 watt with holder base (B22) type & 5star rating, 1200mm lumen outputcomplete all as specified. Make of LED lamp:- Havells cat part No-LHLDEUEBML8Z010 or Equivalent cat part of make:-Wipro / Crompton / Bajaj / cropmpton
M/S BONA CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .