Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAdmitted-Finance | ₹13.3 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically not qualified bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not qualified bidder |
| Sl No | Description | Qty | Unit | Aircon Sales and Services L1 |
|---|---|---|---|---|
| 1.00 | Supplying, installing, testing & commissioning split type variable speed inverter technology with DC Rotory Inverter Compressor, room air conditioning unit 1.5 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 45dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.12 for 1.5 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote. | 4 | Nos. | 46,500 ₹1,86,000 Lowest |
| 2.00 | Supplying, installing, testing & commissioning split type variable speed inverter technology with with DC Rotory Inverter Compressor. room air conditioning unit 2 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 47dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.05 for 2 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote. | 16 | Nos. | 54,500 ₹8,72,000 Lowest |
| 3.00 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete. | 85 | Meter | 800 ₹68,000 Lowest |
| 4.00 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete. | 85 | Meter | 750 ₹63,750 Lowest |
| 5.00 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete | 32 | Meter | 700 ₹22,400 Lowest |
| 6.00 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete. | 32 | Meter | 690 ₹22,080 Lowest |
| 7.00 | Drain piping in UPVC with all fittings, supports and clamps upto 20/25 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe. | 92 | Rmt | 100 ₹9,200 Lowest |
| 8.00 | Set of Power & Control Cabling complete for all circuits of machine with insulation and conduiting complete with supporting arrangement etc. for Hiwall Split AC. | 145 | Rmt | 150 ₹21,750 Lowest |
| 9.00 | MS structural work structure for condensing units, Powder Coated | 20 | Nos. | 1,500 ₹30,000 Lowest |
| 10.00 | Core cutting in wall/slab/Beam for AC piping | 150 | Inches | 140 ₹21,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹34,600
Closing Date
4 Nov 2025, 11:00 amClosed
Estate Manager
IUCAA, Pune
Tender for SITC of 5 Star Inverter Split AC At IUCAA, Pune
2025_IUCAA_880204_1
M24-0779
Open Tender
Electrical Works
Works
21 days
IUCAA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Payable To IUCAA
₹34,600
IUCAA, Pune
19 Dec 2025
6 Oct 2025
5 Nov 2025
6 Oct 2025
4 Nov 2025
6 Oct 2025
6 Oct 2025 - 13 Oct 2025
16 Oct 2025
Amount
Supplying, installing, testing & commissioning split type variable speed inverter technology with DC Rotory Inverter Compressor, room air conditioning unit 1.5 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 45dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.12 for 1.5 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper Tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote.
Supplying, installing, testing & commissioning split type variable speed inverter technology with with DC Rotory Inverter Compressor. room air conditioning unit 2 TR capacity suitable to operate on 220-240 V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall type complete with refrigerant R32/R410 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 47dBA at position. The minimum acceptable value of ISEER Value of the offered Split AC model shall be not less than 5.05 for 2 TR on 100% laod. The ISEER value confirmation should be done by the OEM on their authentic letter head. Condensing unit with reputed make hermetically sealed rotary inverter compressor, air cooled condenser with copper tubes, extended aluminum fins and condenser fan with adequate air flow capacity suitable for operation at ambient temp. of 45 deg C. Indoor unit consisting of 3/4 row-cooling coil blower with motor, filters, drain pan & casing. The evaporator shall be complete with expansion valve & distributor. The outdoor unit shall be factory tested and filled with first charge of refrigerant R-32/R-410A before delivering at site. The units shall be with individual cordless remote.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line/suction line supply and return piping of 18 gauge (copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of refrigerant piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of refrigerant air conditioning system complete.
Drain piping in UPVC with all fittings, supports and clamps upto 20/25 mm dia. including drilling hole in wall chipping wall etc to conceal and to route drain pipe.
Set of Power & Control Cabling complete for all circuits of machine with insulation and conduiting complete with supporting arrangement etc. for Hiwall Split AC.
MS structural work structure for condensing units, Powder Coated
Core cutting in wall/slab/Beam for AC piping
Dismantling of existing split A/cs and refrigerant piping
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_925213.xls
BOQ • 0.34 MB
TechnicalBid.pdf
Tender Documents • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .