| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAccepted-AOC 2ND FLOOR KAMARHATI 1 GRAHAM ROAD KAMARHATI KAMARHATI KOLKATTA WEST BENGAL 700058 | 24 PARAGANAS NORTH | WEST BENGAL | 700058 | ₹5.5 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹5.7 CrRejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹5.7 Cr | L2 | Rejected-Finance Higher Bid |
| 3 | L3₹5.7 CrRejected-Finance | ₹5.7 Cr | L3 | Rejected-Finance Higher Bid |
| 4 | L4₹6.3 CrRejected-Finance MIA GARAGE BUILDING 1ST FLOOR HILLCART ROAD DIST SILIGURI PIN 734401 | SILIGURI | SILIGURI | WEST BENGAL | 734401 | ₹6.3 Cr | L4 | Rejected-Finance Higher Bid |
| 5 | Rejected-Technical | - | - | Rejected-Technical due to (1) non-submission of appropriate credential, justifying the amount as per Clause 6-(iii)/(iv)/(v) of page-2 of NIT and (2) non-submission of original file of e-NIT and Form-2911, as per Clause-5-A-1(i) of NIT Page-7. |
| Sl No | Description | Qty | Unit | CHAKRABORTY ENTERPRISE L1 | JAYBEECO L3 | RASH ELECTRICAL WORKS L2 | M/S. N.C. HORE L4 |
|---|---|---|---|---|---|---|---|
| 1.00SUB-HEAD I : SITC OF VCB PANEL, TRANSFORMER & LT PANEL | |||||||
| 1.01 | Supply & Delivery of Indoor-type, floor mounted,metal clad,single tier, totally enclosed and fully interlocked, fully compartmentalized, free standing, 11 kV VCB Panel with 3 Nos 800 A VCBs (1 Incomer + 2 Outgoing) as per IS 13188, as ammended upto date and as per detail specification and approved make attached ( uploaded in the specification section) , suitable for use on 11 KV, 3 Phase,50 Hz AC supply to energise 2 nos 1600 KVA Mineral oil filled Type Transformers . | 1 | Set | 21,30,500 ₹21.3 L | 17,75,000 ₹17.8 L | 20,70,000 ₹20.7 L | 20,73,732 ₹20.7 L |
| 2.00 | Installation, Testing & Commissioning of the above 11 kV VCB Panel with PT & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement. | 1 | Item | 22,000 ₹22,000 | 15,000 ₹15,000 | 33,120 ₹33,120 | 28,603 ₹28,603 |
| 3.00 | Supply & Delivery 1600 KVA, 3 Phase , Cast Resin Mineral oil filled Type Transfirmer suitable for operation in 11KV/415V, 50Hz power supply, having cable end box in the HV side & provision for bus truncking at LV side and all accessories and conforming to IS 11171-1985 & IS - 2026 with latest modification (if any) & CBIP Specification and as per detail specification and approved make attached ( uploaded in the specification section) | 2 | Set | 48,90,000 ₹97.8 L | 51,25,225 ₹1.0 Cr | 49,68,000 ₹99.4 L | 52,42,966 ₹1.0 Cr |
| 4.00 | Installation, Testing & commissioning of above 11 KV/ 415 volt, 1600 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc. | 2 | no. | 22,000 ₹44,000 | 12,000 ₹24,000 | 24,840 ₹49,680 | 21,452 ₹42,904 |
| 5.00 | MAIN LT PANEL IN THE SUBSTATION : -
SITC of floor mounted Indoor type extensible cubical type LT Panel,fabricated by CPRI approved panel maker as per size, design & drawing to be approved by EIC and conforming to relevant IS with latest modification and as per detail specification and approve make attached ( uploaded in the specification section) (To be installed at Sub-Station bldg)
[I/C 2500A 4P ACB - 2 Nos & Buscoupler 2500A 4P ACB - 1 No with electrical-mechanical Interlock, BBC 3200A 4 Bars- 02 Set, O/G : 1600A 4P ACB - 02 nos + 400A 4P MCCB - 02 NOS+ 320A 4P MCCB - 05 NOS + 250A 4P MCCB - 04 NOS + 200A 4P MCCB - 03 nos] | 1 | Set | 58,70,000 ₹58.7 L | 63,43,837 ₹63.4 L | 68,49,216 ₹68.5 L | 76,08,451 ₹76.1 L |
| 6.00 | EMERGENCY (DG) POWER PANEL AT SUBSTATION:
SITC of floor mounted indoor type expandable cubical MV Switchboard with ACB/MCCBs in suitable enclosure having Short Circuit withstand capacity of 31 MVA (i.e, 45 KA) for one second, fabricated by CPRI Approved panel builder as per detail specification and approved make attached ( uploaded in the specification section) (To be installed at Sub-Station bldg)
[I/C 1600A 4P ACB - 2 Nos & Buscoupler 1600A 4P ACB-1 No with electromechanical Interlock, BBC 1600A 4 Bars- 2 Set, O/G : 1250A 4P ACB - 1 nos, 1000A 4P ACB - 2 nos. + 800A 4P ACB-1 NO+160A 4P MCCB - 2 nos, 250A 4P MCCB - 2 nos. & 100A 4P MCCB - 2 nos.] | 1 | Set | 45,16,500 ₹45.2 L | 46,20,026 ₹46.2 L | 52,25,122 ₹52.3 L | 58,10,740 ₹58.1 L |
| 7.00 | SUB PANEL AT GROUND (PANEL NO -2 &3 ): SITC of floor mounted indoor type expandable cubical MV Switchboard with ACB/MCCBs in suitable enclosure having Short Circuit withstand capacity of 31 MVA (i.e, 45 KA) for one second, fabricated by CPRI Approved panel builder as per detail specification and approved make attached ( uploaded in the specification section) (To be installed at Building)
[I/C 1000A 4P ACB - 1 Nos, BBC 1200A 4 Bars- 1 Set, O/G : 320A 4P MCCB - 1 nos. + 250A 4P MCCB - 3 nos+ 100A 4P MCCB-4 Nos] | 2 | Set | 15,82,000 ₹31.6 L | 18,70,913 ₹37.4 L | 18,78,346 ₹37.6 L | 20,99,474 ₹42.0 L |
| 8.00 | SUB PANEL AT GROUND FLOOR (PANEL NO-4): SITC of floor mounted indoor type expandable cubical MV Switchboard with ACB/MCCBs in suitable enclosure having Short Circuit withstand capacity of 31 MVA (i.e, 45 KA) for one second, fabricated by CPRI Approved panel builder as per detail specification and approved make attached ( uploaded in the specification section) (To be installed at Building)
[I/C 1000A 4P ACB - 1 Nos, BBC 1200A 4 Bars- 1 Set, O/G : 250A 4P MCCB - 4 nos+ 100A 4P MCCB-4 Nos] | 1 | Set | 15,70,000 ₹15.7 L | 18,64,325 ₹18.6 L | 18,81,285 ₹18.8 L | 20,80,882 ₹20.8 L |
| 9.00 | SUB PANEL AT GROUND FLOOR ( PANEL NO-1): SITC of floor mounted indoor type expandable cubical MV Switchboard with ACB/MCCBs in suitable enclosure having Short Circuit withstand capacity of 31 MVA (i.e, 45 KA) for one second, fabricated by CPRI Approved panel builder as per detail specification and approved make attached ( uploaded in the specification section) (To be installed at Building)
[I/C 250A 4P MCCB - 1 Nos, BBC 315A 4 Bars- 1 Set, O/G : 100A 4P MCCB - 4 nos] | 1 | Set | 4,90,000 ₹4.9 L | 5,50,927 ₹5.5 L | 5,99,306 ₹6.0 L | 6,82,186 ₹6.8 L |
Tender Value
₹4.8 Cr
EMD Value
₹9.5 L
Closing Date
29 Oct 2025, 1:00 pmClosed
SE, NBEC, PWD
Office of the SE, NBEC, PWD, Venusmore, Siliguri
Construction of Cancer Care Centre at North Bengal Medical College and Hospital, Siliguri under North Bengal Construction Division_External electrical installations works
2025_WBPWD_900311_1
WBPWD/SENBEC/eNIT-03/2025-2026
Open Tender
ELECTRICAL WORKS ORG
120 days
Siliguri
Please refer Tender documents.
8 documents required · 8 mandatory
₹9.5 L
Siliguri
18 May 2026
11 Sept 2025
31 Oct 2025
11 Sept 2025
29 Oct 2025
23 Sept 2025
18 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.25 MB
Tendernotice_2.pdf
PDF • 1.30 MB
Tendernotice_3.pdf
PDF • 2.33 MB
BOQ_2034282.xls
BOQ • 0.66 MB
Download all tender documents and submit your bid