Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹18.7 L+₹2.0 L (12.1%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance being not lowest | |
| 3 | L3₹18.9 L+₹2.2 L (13.5%)Rejected-Finance | L3 | Rejected-Finance being not lowest | |
| 4 | L4₹19.9 L+₹3.2 L (19.4%)Rejected-Finance | L4 | Rejected-Finance being not lowest | |
| 5 | L5₹20.7 L+₹4.0 L (24.2%)Rejected-Finance | L5 | Rejected-Finance being not lowest |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
14 Nov 2022, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIR MAINTENANCE REWIRING IN MD ACCN INCLUDING REPAIR RE-WINDING MAINTENANCE OF CEILING FANS, PEDESTAL FANS, WALL MOUNTING FANS, VENTILATING FANS UNDER AGE EM OF GE(WEST) PATHANKOT
2022_MES_558016_1
GE/PKT-48/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹54,000
Yes
3 Jan 2023
15 Oct 2022
16 Nov 2022
15 Oct 2022
14 Nov 2022
31 Oct 2022
17 Oct 2022 - 27 Oct 2022
Amount
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators and sockets by unscrewing carefully from boards etc and making good disturbed surfaces of walls, as per existing finishes complete all as spd and directed.
M & L for point wiring for one light/one fan controlled by one switch with 1.5 PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC concealed conduit heavy duty 20 mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked for switches and sockets , including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green).
All as per Srl Item No 2 here-in-before but for call Bell point complete all as specified and directed.
All as per Srl item No 2 here-in-before but for 5 pin 5 amps socket outlet on independent board complete all as specified and directed.
All as per Srl item No 2 here-in-before but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
M & L for point wiring with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed. Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green).
M & L for point wiring for light / fan controlled by one switch with 1.50 sqmm PVC insulated unsheathed multistrand coper conductor FRLS cable in existing PVC concealed conduit terminated in new anodise pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed piping , including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green).
All as per Srl No 7 here-in-before but for call Bell point complete all as specified and directed .
All as per Srl item No 7 here-in-befor but for 5 pin 5 amps socket outlet or independent board complete all as specified and directed.
All as per Srl item No 7 here-in-befor but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
M & L for point wiring with 2.50 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable in existing PVC concealed conduit terminated in new anodised pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed piping ,including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green).
M & L for Modular point wiring for one light/one fan controlled by one switch with 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC concealed conduit ISI maked heavy duty for one light fan/bell point controlled by one switch including Modular cover plate and modular metallic flush boxes of suitable way modular boxes and cover plates including PVC green insulated unsheathed 1.5 sqmm multistrand copper conductor FRLS cable as continous earthwire and connecting to earth duly, complete all as specified and directed. Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
All as per srl item No 12 here-in-before but MODULAR call Bell point complete all as specified and directed.
All as per srl item No 12 here-in-before but MODULAR 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
All as per srl item No 12 here-in-before but MODULAR 3 pin 5 amps socket outlet on independent Board complete all as specified and directed.
All as per srl item No 12 here-in-before but MODULAR 15/16 Amps socket outlet on inependent board with 2.5 sqmm copper conducter FRLS cale and 2.5 sqmm PVC insulated unsheathed coper onductor cable FRLS (Green Colour) as earth lead complete all as specified and directed.
S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S & F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
S&F switch Bell push, flush type, 5 amp one way complete all as specified and directed by Engr-in-charge..
S&F of Bell Ding Dong, AC 230 Volts single Phase complete all as specified and directed by Engr-in-charge.
S & F Modular switch 1 way 6 A, 1 module complete all as specified and directed.
S & F Modular switch 1 way 16A, 1 module complete all as specified and directed.
S & F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S & F of Modular Bell push 6A 1 module , complete all as specified and directed.
S & F of Modular Fan regulator 6A 1 module , complete all as specified and directed.
S & F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
Supply and fixing ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed.
S & F in replacement of CFLs with LED Lamp, B22 type ,14 watt,complete all as specified and directed.
S & F in replacement energy saving decorative LED box type (4 Feet), frame , light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired without tube and making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as spd and directed by Engr -in -charge. Make of Fitting:- CROMPTON DMLN1LT8-16 or Technocommercially equivalent in any of the make mentioned in list of products.
S & F energy saving Led Rod 20 watt (4 Feet), 230 volts, 6500 K energy efficient tube light complete all as spd and directed. Make of LED Rod:- CROMPTON LTT8-20 or Technocommercially equivalent in any of the make mentioned in list of products.
Supply and Fixing in replacement LED Bulkhead fitting 10 watt all as specified and directed by Engr-in-charge. Make :- Crompton Cat Part No:- LBHP-10-CDL or equvalent in any of the make mentioned in list of products.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller PVC type AC ventilating fans, Single phase, 230 volts 250 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller PVC type AC ventilating fans, Single phase, 230 volts 300 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
S&F in replacement sleek LED Batten light fitting 4 feet long 1x22 W including LED tube 4 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed.
S & F in replacement of Decorative Gate Light Moon Opal made up of high Grade unbreakable polycarbonate material suitable for and including 12/20 Watt LED Bulb complete all as specified and directed. Make Havells :- Cat Part No:- LHFXBON1TN5Q020 or in any of the make mentioned in list of products.
S & F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed .
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 6 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed.
M & L for MCB SP 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
M & L for MCB SPN 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed.
All as per srl item No 47 here-in-before but submain wiring with 2 single core 4 sqmm and one 4 sqmm as eathing lead.above but 4.00 Sqmm
S & F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a)MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series as outgoing (Note :- (i)The DB shall be VTPN series of Schenieder Cat Part No:- A9HVD04L or equivalent in any of the make mentioned in list of product . (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(1v) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (vi)MCCB's and MCB's should have a same make as of DB.
S & F in replacement bldg secuirty light fitting energy saving high efficiency LED street light fitting 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length on less than 1.5 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. Make: CROMPTON CAT REF. LSTS-25-CDL or technocommercially equivalent in any of the make mentioned in list of products.
M & L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Supply & Fixing in replacement of Socket outlet 2 in 1, 3 pin, 5A complete in existing circuit complete as directed buy Engr-in-charge.
Supply & Fixing in replacement switch piano flush button single pole one way 5 Amp 230 volts in existing circuit as directed buy Engr-in-charge.
Supply and Fixing in replacement of socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
Supply and Fixing in replacement of switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
Supplying & Fixing in replacement of Switch Bell push, flush type, 5 amp one way complete all as specified and directed by Engr-in-charge..
S&F in replacement of Buzzer Ding Dong, AC 230 Volts single Phase complete all as specified and directed by Engr-in-charge.
S & F in replacement lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings in existing circuit complete all as specified and directed.
Supply and Fixing in replacement Gang Box 15 Amp Switch socket combined complete all as specified and directed by Engr-in-charge.
Supply and Fixing in replacement Gang Box 5 Amp Switch socket combined complete all as specified and directed by Engr-in-charge.
S&F in replacement Hylum sheet 4x4 to 4x6 inches for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by EIC
S & F in Repl of MCB SP 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
S & F in Repl of MCB SPN 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed.
S&F in replacement Hylum sheet 6x10 to 8x10 inches for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by EIC
S & F in replacement of Modular Metal flush box 3 module, complete all as specified and directed.
S & F in replacement of Modular Metal flush box 4 module, complete all as specified and directed.
S & F in replacement of Modular Metal flush box 6 module, complete all as specified and directed.
S & F in replacement of Modular Metal flush box 8 module, complete all as specified and directed.
S & F in replacement of Modular Metal flush box 12 module, complete all as specified and directed.
S & F in replacement of Modular White cover plate with frame, 3 module, complete all as specified and directed.
S & F in Replacement of Modular White cover plate with frame, 4 module, complete all as specified and directed.
S & F in replacement of Modular White cover plate with frame, 6 module, complete all as specified and directed.
S & F in replacement of Modular White cover plate with frame, 8 module, complete all as specified and directed.
S & F in replacement of Modular White cover plate with frame, 12 module, complete all as specified and directed.
Taking down carefully 1200/1400mm sweep ceiling fan any make from the hook of OTM/MD Accn carrying to the wksp including rehanging the same at existing position after cleaning, greasing and connecting up with PVC insulated copper flexible wire 3 x single core 1.0 Sqmm from ceiling rose to connector of fan complete all as specified and directed by Engr-in-Charge . NOTE :-1. PVC copper flexible wire 1.0 Sqmm single core( 3 runs each) shall be measured and paid separately under relevant item. 2. Total service time from taking down to rehanging must not exceed 3 Days . 3. T&P such as ladder and vechicle will be provided by contractor at their own expense .
Strip opening of ceiling fan 1200mm sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to deptt , tachometer will be provided by contractor at their own expense) and all insulating materials (spares will be used and measure in respective items) and reasembling etc complete all as specified and directed by Engr-in-Charge. (Note :- Under defect liability period, in case winding or any accessory i.e capacitor, regulator becomes non functional, it will be repaired without any extra cost within 10 days of complaints received.)
All as per srl item No.76 above but ceiling fan of 1400 mm sweep. (NOTE :- 1. Srl No 76 & 77 taking down, cleaning greassing and rehanging shall be measured and paid under item 75.00 above. 2. Under liability period, in case winding or any accessory i.e capacitor, regulator, becomes non functional, it will be repaired without any extra cost within 10 days of complaints received.)
Painting of ceiling fans 1200/1400 mm sweep including blades complete with white synthetic enamel paint by spray painting to achieve a smooth and uniform finish (one coat) including scrabbing existing paint, cleaning and filling up cavaties with suitable filler complete all as specified and directed by Engr-in-Charge. (Note :- Painting of fans must be done before delivery of fan (after item srl No 76 & 77 complete) by contractor to Deptt on same day.
Supply & fixing ball bearings of size 6201 suitable for ceiling fans/exhaust fans complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 79.00 here-in-before but of size 6202 complete.
All as per srl item No. 79.00 here-in-before but of size 6203 complete.
All as per srl item No. 79.00 here-in-before but of size 6204 complete.
Taking out existing worn out gun metal bush and material & labour for new gun-metal bush (of suitable size) to the ceiling fans of any size/make incl reassembling and testing etc complete all as specified and directed by Engr-in-Charge.
Taking out existing defective/worn out condenser any size/make and material and labour for condensor of capacity 2.5 mfd, 220 V including making connections etc complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 84.00 here-in-before but of capacity 3.15 mfd capacity.
All as per srl item No. 84.00 here-in-before but of capacity 4 mfd capacity.
Taking down carefully exhaust fan 225mm to 450mm sweep from the existing any make including re-fixing in existing position after cleaning and greassing complete all as directed by Engr-in-Charge. (NOTE :- Total service time from taking down to rehanging must not exceed 3 Days.)
Material and labour for rewinding of stator assembly of exhaust fan/bracket fans/wall mounting fans/pedestal fans 375 to 450mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring so as to achieve original specifications i.e current rating and RPM including all insulating materials, re-assembling and replacement of worn out nuts, bolts, rubber bushes, clamps etc complete all as specified and directed by Engr-in-Charge. (Note :- 1. Taking down cleaning, greasing and re-fixing in position shall be measured and paid under srl item No. 87.00 here-in-before. 2. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 3. No T&P will be provided by the Deppt. 4. Warranty period is 1 year,in case winding or any accessory i.e capacitor,regulator ,becomes non functional within 1 year , it will be repaired without any extra cost within 10 days of complaints received.)
All as per srl item No.88.00 above here-in-before but of 225 size to 300 mm sweep. (Note :- 1. RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer -in -Charge. 2. No T&P will be provided by the Deppt. 3. Under liability period ,in case winding or any accessory i.e capacitor, regulator, becomes non functional, it will be repaired without any extra cost within 10 days of complaints received.)
Painting to exhaust fans/bracket fans/wall mounting fans/pedestal fans up to 300 mm sweep of any make motor, body, blade and frame with one coat of synthetic enamel smoke grey paint by spray painting to achieve smooth and uniform finish incl removal of existing paint, filling up cavities with filler complete all as specified and directed by Engr-in-Charge . (Note :- Painting of fans must be done before delivery of fan (After item srl no 88.00 & 89.00) by contractor to Deptt on the same day.)
All as per ser item No 90.00 above but of size 375 to 450 mm sweep.
Taking out existing worn out rubber reel, clamp and supply & fixing of rubber reel with clamps, MS nuts, bolts heavy duty of suitable size for hanging of ceiling fan to hook etc complete all as directed.
Taking out rusted screws & S&F of screws for fixing to different type/make blades of ceiling fans complete.
Taking out worn out/defective adopter and M & L for MS adopter coupling suitable for universal joint of ceiling fan and down rod for different makes of ceiling fans complete all as directed.
Taking out worn out/cracked canopy and supply & fixing canopy (Set of 2 pieces) with screws to the celing fans of any size/make etc complete all as directed.
Taking out rusted/worn out threaded down rod and supply & fixing down rod made out of 15 mm dia medium grade GI pipe having one side thread and on other side hole or both side threaded/hole 2 feet long complete all as specified and directed.
Taking out rusted/worn out threaded down rod and supply & fixing down rod made out of 15 mm dia medium grade GI pipe having one side thread and on other side hole or both side threaded/hole 2.5 feet complete all as specified and directed.
Taking out rusted/worn out threaded down rod and supply & fixing down rod made out of 15 mm dia medium grade GI pipe having one side thread and on other side hole or both side threaded/hole 3 foot complete all as specified and directed.
Taking down defective fan regulator any type and make and supply & fix electronic step type fan regulator 5 stage speed variation ISI marked including making connection etc complete all as specified and directed.
Taking out existing defective flexible wire of any size and M&L for PVC copper cable flexible 3 core 1.0 Sqmm 1100 volts (FR) three core fixed to ceiling fan/exhaust fan (not more than 1.0 Mtrs to each fan) complete all as specified and directed.
Taking down worn out blades of exhaust fan/wall mounting/padestal fan off size 225 to 300mm sweep and supply and fixing new blades as per sample and make to the fan refixing in existing position etc complete all as specified and directed.
All as per srl item no 101.00 here-in-before but 375 to 450mm sweep.
Taking down worn out blades of ceiling fan off size 1200 to 1400 mm sweep and supply and fixing new blades as per sample and make to the fan refixing in existing position etc complete all as specified and directed.
Supply only plastic bottom cover of ceiling fans any size & any make of fan complete with all fixing arrangements complete all as specified and directed.
Supply and Fixing in replacement of switch socket combination 5 amps 230 volts complete all as specified and directed.
Supply and Fixing in replacement of switch socket combination 15 amps 230 volts complete all as specified and directed.
Supply and Fixing in replacement of LED batten fitting 4 feet long 22 watt complete all as specified and directed.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 4,28,316.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
M/S SHAKTI ELECTRIC WORKS
Om Sai Ram Builders
M/S NILESH ENTERPRISES
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .