Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 CrAccepted-AOC WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹18.7 Cr | L1 | Accepted-AOC Being lowest and reasonable tender |
| 2 | L2₹19.1 CrRejected-Finance THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹19.1 Cr | L2 | Rejected-Finance Not being the lowest |
| 3 | L3₹22.0 CrRejected-Finance | ₹22.0 Cr | L3 | Rejected-Finance Not being the lowest |
| 4 | L4₹22.6 CrRejected-Finance | ₹22.6 Cr | L4 | Rejected-Finance Not being the lowest |
| 5 | Rejected-Technical NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | - | - | Rejected-Technical Residual work in hand is more than twice the present tendering limit. |
Tender Value
₹17 Cr
EMD Value
₹11.8 L
Closing Date
22 Jul 2021, 6:00 pmClosed
CHEIEF ENGINEER
26, ASSAYE BUILDING, COLABA, NEW DELHI
PROVISION OF AUDITORIUM AT INS KADAMBA KARWAR
2020_MES_382470_3
87870/E8
Open Tender
Civil Works
660 days
kARWAR
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (SB) KARWAR
₹11.8 L
Yes
1 Sept 2021
8 Jun 2021
24 Jul 2021
8 Jun 2021
22 Jul 2021
8 Jul 2021
9 Jun 2021 - 25 Jun 2021
Amount
SCH 'A' PART-I "BUILDINGS & STRUCTURES" Total of Sch-'A' Part-I B/F from Serial Page No.35
SCH 'A' PART- II "SITE CLEARANCE, EXCAVATION & EARTH WORK. Total of Sch "A" Part-II B/F from Sl page No 37
SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Sch "A" Part-III B/F from Sl page No 38
SCH 'A' PART-IV "INTERNAL ELECTRIFICATION" Total of Sch "A" Part-IV B/F from Serial Page No 42
SCH 'A' PART-V "ROAD/ PATH / CULVERTS" Total of Sch "A" Part-V B/F from Serial Page No 43
SCH 'A' PART-VI "AREA DRAINAGE " Total of Sch "A" Part-VI B/F from Serial Page No 46
SCH 'A' PART-VII "COMPOUND WALL , FENCING AND GATE " Total of Sch "A" Part-VII B/F from Serial Page No 48
SCH 'A' PART- VIII "FIRE DETECTION & FIRE ALARM SYSTEM" Total of Sch "A" Part-VIlI B/F from Serial Page No 53
SCH 'A' PART-IX ""LIGHTIENING PROTECTION"" Total of Sch "A" Part-IX B/F from Serial Page No 54
SCH 'A' PART-X "SEWAGE DISPOSAL" Total of Sch "A" Part -X B/F from on Serial Page No 56
SCH 'A' PART-XI "EXTERNAL WATER SUPPLY" Total of Sch "A" Part-XI B/F from Serial Page No 57
SCH 'A' PART-XII "EXTERNAL ELECTRIFICATION" Total of Sch "A" Part-XII B/F from Serial Page No 60
SCH 'A' PART-XIII "AIR CONDITIONING" Total of Sch "A" Part-XVI B/F from Serial Page No 62
SCH 'A' PART-XIV "ARBORICULTURE" Total of Sch "A" Part-XVI B/F from Serial Page No 63
SCH 'A' PART-XV "PILE FOUNDATION" Total of Sch "A" Part-XVI B/F from Serial Page No 64
SCH 'A' PART- XVII" MISCELLANEOUS ITEMS"
"PILE FOUNDATION"
M&L for boring / drilling in to any strata other than hard rock for 500mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed.
M&L for boring / drilling in hard rock for 500mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed.
M&L for boring / drilling in to any strata other than hard rock for 600mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed.
M&L for boring / drilling in Hard rock for 600mm dia under-reamed piles by DMC method using bentonite slurry wherever required or by providing 6mm thick MS temporary liners for stabilization of pile using drilling by any other method as required, in any type of soil / soft disintegrated rock including flushing of pile bore, cleaning complete all as specified and directed.
M&L for RMC M-30 design mix concrete as in piles using tremie pipe concrete method for 500/600mm dia piles with minimum 400 Kg cement per Cum complete all as specified and directed.
M & L for testing of piles (Initial Test) as per IS 2911 Part 4 up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for 500 mm dia piles complete all as specified and directed through NABL / Goverment approved accredited laboratory.
M & L for testing of piles (Initial Test) as per IS 2911 Part 4 up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for 600 mm dia piles complete all as specified and directed through NABL / Goverment approved accredited laboratory.
M&L for testing of piles (Routine Test) as per IS 2911, Part 4, up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for the 500 mm dia piles complete all as specified and directed through NABL / Government approved accredited laboratory.
M&L for testing of piles (Routine Test) as per IS 2911, Part 4, up to 2 times the safe bearing capacity all as specified and indicated on drawings including bringing at site all testing material complete and removing of the same after completion of satisfactory testing for the 600 mm dia piles complete all as specified and directed through NABL / Government approved accredited laboratory.
M&L for carrying out integrity test on job piles of 500/600mm dia piles including bringing at site all testing material complete and removing of the same after completion of satisfactory testing of piles complete all as specified and as directed through NABL/Government approved accredited laboratory.
"INTERNAL ELECTRIFICATION"
Supply and Fix Lamp holder insulated body with back plate and including LED Lamp 9 Watt for angle holder all as specified. Make: Havells/LEGRAND/Anchor/Leader
S & F LED light fittings decorative 36/34 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Supply and fixing LED Step light strip of 1 meter long embeded in aluminium extrusion wth acrylic cover and fixed on floor emitting a low light to outline a specific area or used for guideline for step,5 watt per meter including driver in duly powder coated aluminium die cast housing. IP65. Halonix/Crompton/HPL/Philips.
Supply and fixing recess mounting accent lighting luminaire with dia cast aluminium heat sink and sand grain finishing refletor with DALI dimmable driver round LED down lighter ,20 watt wide beam , 4000 k ,100 lm/w system .IP 20. havells/ Halonix / HPL/Philips.cat no RS271B LED 20/840 PSD WB WH ( for Main Hall & Stage )
Supply and fixing recess mounting accent lighting luminaire with dia cast aluminium heat sink and sand grain finishing refletor with DALI dimmable driver round LED down lighter ,40 watt wide beam , 4000 k ,100 lm/w system .IP 20. havells/ Halonix / HPL/Philips.cat no RS271B LED 40/840 PSD WB WH ( for Main Hall )
Supply and fixing Track mounted spot accent lighting luminaire with no external gear box and magnetic hinge arrangement for easy aiming and perfect punch in the beam.,20 watt wide beam , 4000 k ,100 lm/w system .IP 20. havells/ Halonix / HPL/Philips.cat no ST916T LED20/940 PSU 1C WB BK IN ( for Stage )
Supply and fixing Surface Mounting Up-Downlight Luminaires wall mounting outdoor type 1x 50 watts made out of Black epoxy powder coated aluminium housing with wall mounting bracket Par light fitting. Bajaj/Crompton/Havells/HPL/Philips.
Supply and fixing Flood light fitting LED 200 Watts, energy saving environmental friendly, long life exclusive innovatiive die cast aluminium IP 66 flood light with high power LED as light source suitable for high lighting architectural features or retail spaces FloodTune is easy to use, reliable and cost effective color changing outdoor flood light for creating dynamic lighting effects by just using your smart phone to control lights. ( For stage lighting) Make : Bajaj cat n0- BARFEG 200W LED/HAVELLS cat no- JETA PROPLUSFL200WLED757LT G /Cropton Cat no -LSFO-200-CDL/60
Supply and fixing Gong Bell 225 mm dia , 230 volts
S & F MCB DB VERTICAL TYPE , suitable for RCBO / MCB as incommer,,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door , L&T / LEGRAND / Schneider/ ABB
S & F MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incomer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ Schneider/ ABB ( for stage lighting & projection room )
S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps
S & F MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
NOTE FOR ITEM NOS. 19.10 TO 19.13 - MAKE OF MCCB & MCB - LEGRAND/HAGER/SCHNEIDER/l&T
S&F Exhaust fan heavy duty of size 225 mm sweep PVC body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make:- Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. ( for Tech Building & Adm Building ) -Make:- Crompton Greaves/ Bajaj/Orient
Supply & fixing wall mounted fan 450 mm sweep high speed, thermally protected motor, heavy duty gear box, 90 degree oscillation for wide coverage conforming to IS-2997-1964 all as specified and directed by Engineer-in-Charge. Make:- Havells/Crompton Greaves/Bajaj/Orient
Supply and lay 2 pair Telephone Cable copper 0.5 mm dia ATC drawn through conduit.
S & F RJ 11 Telephone socket
Supply, Installation, test and Commissioning CPRI approved factory fabricated, Indoor type, LT Pannel Board made out of 2.00 mm thick CRCA Sheet dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - Metre room )
(a) MCCB 250 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No. (incoming)
MCCB 125 A 25 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -02 No. (outgoing for stage lighting & projector room)
(b) MCCB 63 A 25 KA, 3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -02 Nos. (outgoing)
(c) MCCB 40 A 25 KA, 2 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -11 Nos. (outgoing)
(e) Aluminum TPN bus bar 250 Amps - 01 Set
(h) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(j) Electronic energy trivactor meter- 01 No,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240v AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection (in case of wrong electric connection),capability to display & communicate ( in case of absence of main supply), with optical port, deficiency metering with either phase/neutral current, IP 51 protection, as per IS13779 including CT,make of meter -L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalent of secure
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromental friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect with all assoceries intenally prewired & including connecting up with 2 core flexible copper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc. make-WIPRO /HAVELLS /JAQUAR /PHILLIPS (for green room & other rooms)
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromental friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block etc with all assoceries intenally prewired & including connecting up with 2 core flexible copper conductor cable with suitable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS ( for Toilets)
S & F MCB DB VERTICAL TYPE , suitable for RCBO / MCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door.
S & F ISI marked RCBO 40 A, 30 mA, 415 V four pole for AC applications, conforming to IS 12640 (Part-2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed.
S & F ISI marked RCBO 40 A, 30 mA, 415 V four pole for AC applications, conforming to IS 12640 (Part-2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed.
MCCB TPN 125 Amps , 415Volts, 25KA ,4 POLE , Icu=Ics=100% L&T / LEGRAND / hager / schneider/ ABB
Supply & fix PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial 3 core 2.5 sqmm cable, 1100 Volt, conforming to IS 694 complete ( for stage lighting )
S & F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
S & F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 40Amps
SITC of 12 Channel Signal Dimmer Controller which can support for DALI Broadcas with Instant visual feedback on channel status for all 12 channels. Device should have override option on the control itself. Supply Voltage: 100-240AC, system Output DC current 200mA which can support 10 button panels without any additional power supply. Device should also have dry contact Aux input.Similar to Dynalite DDBC1200 of Philiphs or equivalant of Havells /Crompton/Bajaj
SITC of 12-channel controller supports switched loads of up to 20 A per channel, up to a maximum device load of 180 A. DIN-rail mountable device, designed to be installed into the distribution board supplying power to the controlled circuit. Supply Voltage: 100-240AC, system Output DC current 200mA which can support 10 button panels without any additional power supply. Device should also have dry contact Aux input.Similar to Dynalite DDRC1220FR-GL-V3 of Philiphs or equivalant of Havells /Crompton/Bajaj
Supply, installation, testing and commissioning of Antumbra Push type 6 key User Interface White with White Rim for workstations, break out areas, training rooms etc with Fully programmable options for individual control / group control / Scene control / Tasks etc. Wall mounted on 2M (3 X 3 size) modular box. Front cover black with Backlight, built in proximity and Loaded icons like presentation scenario, meeting scenario, master On/ Off, Power saving mode etc along with a LED indicator for each operations. Custom engraving facility. Operating on 12V DC @ 40-50mA from Dynet network. Philliphs (Item Code: PA6BPE-WW-X + DACM-V2) or equivalant of havells /crompten/Bajaj
Supply, installation, testing and commissioning of Philips Dynalite DDNP1501 is a 15 V DC 1.5 A regulated power supply designed to supplement the DyNet network DC supply.The DyNet network is self-powered via built-in DC supplies integrated within all mains powered devices. Use of high consumption devices, such as edge-lit touch screens, can necessitate a requirement for additional power. Make philliphs (Item code: DDNP1501) orequivalant of havells /crompten/Bajaj
S&F LED recess mount down light fitting of 18w having System Efficacy of 110 lm/W, system output 2000 lumens, THD <10%, PF >0.95, CRI >80, Body made of piece die cast aluminium housing having PC diffuser, Life L70B50 @ 50k hrs. Cat no: DN296B LED20S 4000K PSD WH of Philliphs or equivalant of Havells/Crompten/Bajaj ( For Front passege & Side passege)
"FIRE DETECTION AND FIRE ALARM SYSTEM"
"FIRE DETECTION SYSTEM"
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 2280LPM discharge at 90 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main FF)
Supply install test and commissiong of centrifugal pump set ,diesel driven complete with all accessories suitable for pumping water 2280LPM discharge at 90 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head reservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main FF)
Supply install test and commissiong of centrifugal Jockey pump set ,Electric driven complete with all accessories suitable for pumping water 180LPM discharge at 90 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head reservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items (jockey pump)
Supply install test and commissiong of centrifugal Booster pump set ,Electric driven complete with all accessories suitable for pumping water 450LPM discharge at 36 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head reservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items (Booster pump)
Supply and laying Ductile iron pipes with spigot and socket ends centrifugally cast, Class K-9, in any length laid in trenches of size 80mm dia Including rubbur Tytan joint complete all as specified and as directed.
Supply and laid spigot/flanged/ socketed DI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 80mm to 300 mm dia.
Supply and Fixing of CI foot valve of size 150 mm dia with stainer conforming to IS :4038 with gun metal seat (flapper) nuts bolts, gaskets, washers etc. only for negative suction (Normex Make 0 % leakage)
Supply and Fixing of CI foot valve of size 100 mm dia with stainer conforming to IS :4038 with gun metal seat (flapper) nuts bolts, gaskets, washers etc only for negative suction (Normex Make 0 % leakage)
Supply and fixing of one no brass orifice plate having 6 mm thickness, outer dia is of 160 mm and inner dia suitable to reduce the pressure between 3.2 Kg / cm v square to 5.5 Kg /cm square at every single outlet hydrant valve DANFOS make pressure switch with 12/15 mm dia isolation valve GI nipple elbow etc.
Supply and fixing of MS priming tank for negative suction only, fabricated from 3 mm MS sheet having capacity 1000 Ltrs with manhole cover float valve 20/25 mm inlet valve and 50 mm outlet valve with necessary GI piping up to delivery of pump, tank should be painted with two coat of red oxdide and two coat of red enamel paint, including MS structure supports.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 2mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main FF Pump)
INCOMING:-
(a) Incoming MCCB 160 A 35 KA, 4 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no- CM92109OOM1OG / Legrand cat no-420247/ Schneider cat no-LV516343-01 No
(b) Bus bar made out of Aluminium flat of capacity 200 Amps- 4 Nos ( 3 nos for phase and 1 no for neutral)
OUTGOINGS:-
(a) MCCB TP 125 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For main pump)
(b) MCCB TP 32 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For Booster Pump & Jocky Pump & Light Load)
(c)Automatic Starter delta starter for 75 HP pump -01 No (For main pump)
(d) BLANK
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(h) Single phasing preventer -02 Nos
Providing and applying one coat of 4mm thick 'PYPKOTE' or COATEK anti rust pipe protection conforming to IS : 10221 including approved primer as per manufactures specificatons and lap of 25mm to made an impermeable layer on M.S.Pipe of size 80mm dia running underground / burried / in trenches complete including surface preparation.
Providing and applying one coat of 4mm thick 'PYPKOTE' or COATEK anti rust pipe protection conforming to IS : 10221 including approved primer as per manufactures specificatons and lap of 25mm to made an impermeable layer on M.S.Pipe of size 150mm dia running underground / burried / in trenches complete including surface preparation.
"FIRE ALARM SYSTEM"
SITC of Intelligent Addressable Fire Alarm Panel, 2 Loop capacity expandable up to 5 loop with minimum 250 addresses on every loop . minumum 160 characters LCD Display, Battery Charger and Power Supply. Complete with all mounting accessories. Furnished with SMF type Lead Acid Battery in above panel for 24 hours backup in case of power failure, and 30 minutes in Alarm Condition.
SITC of Intelligent Addressable Fire Alarm Repeter Panel, Double Loop capacity expandable up to 5 loop with minimum 250 addresses on every loop . minumum 160 characters LCD Display, Battery Charger and Power Supply. Complete with all mounting accessories. Furnished with SMF type Lead Acid Battery in above panel for 24 hours backup in case of power failure, and 30 minutes in Alarm Condition.
Supply and erecting of " Fire Ray 2000" Optival Beam Complete with Transmitter, Receiver, Controller & Apolo XP95 Addressable Zone Monitor unit for Addressing.
M & L for Fire Extinguisher Dry Chemical powder (ABC) type 5 Kg capacity. Ceasefire 9 Kg fire extinguisher mono Ammonium phosphate powder 50, stored pressure type, pressure Guage, Gross weight 8 Kg, empty weight 3 KG, can height 449 mm, Diameter 150 mm, discharge time less than 15 secs, controllable discharge mechanism, Range minimum 4 mtrs, applicable on class A,B,C, & electrically started fire A rating 13A, B rating 34B, can construction deep down and CO2 mig welded valve construction : Forging & Machining internal coating of can : Epoxy powder coating external coating of Can : Epoxy polyster powder coating Sheet metal thickness : 1.80 MM, ISI and EN approved, 5 years warranty. Make cease Fire ABC Powder Map 50 5 Kg – 1AB04CF
Fire Extinguisher Carbon Dioxide type of 4.5Kg capacity.Ceasefire 4.5kg CO2 Gas typre fire Extinguisher, Trolly mounted, Easy weight management Used Unused Mechanism Squeeze Grip, Gross weight 9.1kg empty weight 14.6kg, Can height 857MM, Diameter 140MM, Discharge timeless than 10secs controllable discharge mechanism Applicable on class B&C fire, B rating 21B, Can Construction : Hot Spinning/ Forging, Valve Construction : Forging & Machining, Internal coating of Can : Not Applicable, External Coating of Can : Spray painting sheet metal thickness 4.5MM, ISI Approved 1 year warranty. Make Cease Fire CO2-4.5Kg - Squeeze Grip - 1CO11CF
Fire Extinguisher water type 9 Ltr capacity. Ceasefire 9Ltr Water type Fire Extinguisher, Stored pressure Type, Pressure Gauge,Gross Weight 14.6 Kg, empty Weight 5.6 Kg, Can Height 611MM, Diameter 175MM, Discharge Time less than 120 Secs, Controllable discharge mechanisum, Range minimum 6 mtrs applicable on class a fire a rating 13A, can construction : deep drawn & CO2 Mig welded, valve construction : Forging & machining internal coating of Can : Epoxy powder coating, External coating of Can : Epoxy polyster powder coating sheet metal thickness : 2.0MM, ISI and EN Approved, Helium Leak Detection tested, 1 year warranty. Make Cease Fire Water-9 Ltr Stored Pressure - 1CO02CF.
Supply and Fixing of Buckets ( 9 Ltrs Capacity ) round bottom painted in red and lettered fire with bracket to hang on wall of pillar as directed.
Construction of brick masonary valve chamber of size 1200x 1200x1200 mm (internal dia) suitable for 150 mm dia sluice valve with necessary earth work excavation plain cement concrete 1:4:8 using 40 mm graded stone aggregate 75 mm thick in cement mortar 1:6 15 mm thick plastering 1:6 internally including flooring and externally rep to 15 mm below ground level plain cement concrete 1:4:8 type B1 using 20 mm graded stone aggregate in coping MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement applying two coat of synthetic enamel paint including dismantling removing the existing damage chamber completely removal of debris to a distance not exceeding 50 mtr distance depositing where as directed by Engr-In-Charge.
Providing, fixing, testing and commissioning of 150 mm dia cast iron installation control valve assembly (test pressure should not be less than 15.0 Kg/Sq.cm) with flanges, nut, bolts & gasket complete with pad locking arrangement, vertical wet alarm valve with hydroulic alarm motor & gong, 2 nos pressure gauges as per manufacturer recommendation with ball valves, 15mm dia test valves, 50mm dia drain valve with all necessary accessories.
Providing & fixing cast iron single acting air valve with screwed inlet 25mm dia including ball valve and all fittings complete all as specified and as directed.
Providing and fixing inspection & testing assembly/drain assembly consist of following :-
a) 25mm dia Inspection Test Valve (Ball Valve)
b) Gun Metal Sight Glass
c) Union
d) 50mm dia drain valve with piping
M & L for Low smoke Zero helogen flame retardent fire alaram cable 2 core, 1.5 mm² copper conductor confirming to BS7629-I , BS6387 & rated for 500 v grade having plain stranded copper coductutor with priming insulation of glass mica fire resistance tape & secondary insulation of high performance silicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheathed confirming to BS 7655 , red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet Dust and Vermin Proof , single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (FF booster pump )
(a) Incoming MCCB 32 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No
OUTGOINGS:-
(a) MCB TPN 25 Amps - 1 Nos
(b) DOL Starter for 10 HP Pump set-1 Nos
(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(f ) Single phasing preventer -01 No
Supply and fixing of 15 mm ( 1/2 ")dia NBCM body chrome finished quartzoid bulb sprinkler having 57 deg C fixed temperature rating with defletor disc of conventional construction including MS ERW GI pipe conforming to IS: 1259 including fitting and fixture up to & including 50 mm dia pipe ( As shown in drg) cost of pipe including /below 50 mm is included).
Cutting the existing CI pipe line 200 mm dia bore and inserting one Tee 250mm x 250mmx 80 mm including connecting pipes, collars etc. complete including necessary excavation and earthwork complete all as specified and directed.
"External Water Supply"
Supply install test and commissiong of centrifugal Mono block pump set , electric driven complete with all accessories suitable for pumping water 330 LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head reservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
M&L for construction of valve pit chamber 60 cm x 60 cm x 60 cm internal dimension with 10 cm thick foundation using PCC 1:4:8 type D-2 over 10 cm thick hardcore, 20 cm thick PCC block wall built in cement and sand motor 1:4,15 mm thick internal plaster including top of floor in cement and sand motor 1:5, finished even and smooth, with out using extra cement, 1.4 mm thick MS sheet cover with 20x20x4 mm flat iron hold fast, hinges, handle, locking arrangement and applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface including disposal of surplus soil of to a distance of n.exc 50 m complete all as specified and directed.
Cutting the existing CI pipe line 200 mm dia bore and inserting one Tee 200mm x 200mmx 50 mm including connecting pipes, collars etc. complete including necessary excavation and earthwork complete all as specified and directed.
Supply and fix Brass foot valve, flanged end and drilled of size 50 mm dia ISI MARKED
Supply and fix Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete of size 50 mm dia
Supply and fix brass double end flanged and drilled non return valve of size 50 mm dia ISI MARKED
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 2 mm thick CRCA Sheet , single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( main water supply pump )
(a) Incoming MCB TPN 32 A, 10 KA, 4 POLE , L&T /Legrand /schneider -01 No
(b) Aluminum TPN bus bar 50 Amps - 01 Set
OUTGOINGS:-
(a) MCB SPN 16 Amps - 2 Nos
(b) DOL Starter for 3 HP Pump set-2 Nos
(f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
"DG SET"
(a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.
(b)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: Kirloskar/ashok leyland/cummins
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator.
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery- 2 Nos (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(02x12V Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(c) Alternator: Suitable rated 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof, insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: Stamford/Crompton/Kirloskar
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 10 watt LED fitting of Make Phillips/ Bajaj/ Crompton.
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(f) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(g) Digital load manager : Three phase 4 wire indicating V, I, PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (ii) Bottom gland plate for incoming and outgoing cables. (iii) Circuit diagram plate.
(h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
"EXTERNAL ELECTRIFICATION"
Supply, install, testing and commisioning of Distribution transformer mounted on massoniry platform step down , 11 KV/0.433 KV, Three Phase complying with IS: 1180(Part-1) 2014 with all latest amendments till date, Outdoor type double copper wound suitable for 50 Hz system of capacity 500 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn 11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %. Losses should be confined to the limits specified as follows : maximum allowable losses at full load (100 %) & Half Load (50 %) shall not be exceeded 1.35 % & 0.93 % respectivly as per GRAHA RATING, Percentage Impedance : 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/technical specifications : -
(a) Lifting lug for transformer and tank.
(b) Earthing terminal rating and diagram plate.
(c ) Air release device.
(d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve.
(f) Conservator tank with oil level indicator
(g) Silica jel breather
(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.
(k) Type of connection Delta/Star
(l) Type of cooling: Oil and Natural Air.
(m) Vector group:DYN 11.
(n) Temperature rise over an ambient of 50 °C maximum.
(o) Cable end box on both side for HT/LT cables of suitable size.
(p) Provision of thermometer with pocket.
(q) Provision of oil and winding temperature gauge.
Supply & Fix Battery chargers of sufficient capacity to suit battery sets of 50V, 200 AH Capacity. The battery chargers suitable for 110V-100AH battery sets shall be operative from single phase, 50 Hz, 230 Volts AC supply.The battery charger shall be operative on Thyristor based Silicon Controlled Rectifier (SCR) both for float & boost section.
Supply,Installation,Testing and commissionbing `11 KV indoor, 630 Amps, 18.1 KA for 3 Sec HT Vaccum Circuit Breaker for Incommer confirming to the IEC 62271-200,IAC-AFLR-25KA for 3 Sec PM KLSC -2B comprising of the following equipment :-
800 Amps continous Bus Bar material shall be of high condiuctiveity electrolytic copper only.All Bus bars shall be insulated with heat shrinkable PVC sleeves and joints shall be covered with bitumen compound followed by HT tape. Phase identification shall be made at the end by coloured tape. Bus bars shall be mounted on integral seal off bushings all inter connection shall be of electrolytic grade copper only with joints silver plated.
Circuit breaker shall be mounted on a with drawable truck which shall roll out horizontally from service position to isolated position with ease and .MAKE: ANDREWYULE/AREVA/SIEMENS/ABB
Motorised Spring charged Mechanism
Separate eartyhing truck shall be provided for bus earthing and cable earthing.
Cast Resin Current Transformer, 11 KV, 50/25/5 A, 15 VA, CI 5P 10, CIO 5 Core II PS Class-03 Nos
Cast Resin Three phase Potentail Transformer 11 KV/ 3/110V/ 3, 200VA, CI 1.0 – 03 Nos with desired capacity PT Fuses.
Multifunction meter, Digital type (Displaying A,V,PF,Hz,KVA,KW,KVAR,KWh,KVARh etc) Class 0.5 with RS 485 port for commuinication of Modbus protocol Make : : L&T, Conzerve.
SCADA compatible NUMERICAL NON-DIRECTIONAL IDMT four pole 3 O/C + 1 E/F WITH iNSTANTENEOUS OVER CURRENT AND EARTH FAULT PROTECTION Feeder Protection Relay -01 NOS . Make: ASHIDA Model No: ADR241A/equivalent in ABB /areva/ Siemens.
High Speed Master Trip Relay – 1 No . Make ASHIDA Model No : AVAJH 33/ equivalent in ABB or Siemens.
Trip Circuit Supervision Relay (VAX) – 1 No Make ASHIDA Model No : ATSR31A/ equivalent in ABB or Siemens.
Air Insulated rear end Bottom Entry Cable Box suitable for termination of XLPE Cables.
Panel Must Have additional features
(i) Continous rated closing/tripping coils
(ii) Sprimg Charging Handle
(iii) Fully internal Arc tested for 25 KV for 3 Sec
(iv) Manual closing /tripping of the CB with compartment door closed
(v) Short time rating for 3 seconds as per IEC 62271-100
(vi) Mechanical endurance test-M2
Breaker shall be provided with following features
(i) Auxillaty Switch 6 NO + 1 NC Contacts mounted on the draw out portion of the switchgear
(ii) Position Cell Switch with 3 NO + 1 NC Contact on each for test position and Service Position.
Digital independent Volt meter and ammeter of suitable ratings- 01 each
Inbuild Power pack battery bank OF 30 volt DC (15 nos + 1 nos Spare) Lead acid VRLA MAINTANANCE FREE battery of 2 volts 100 AH) INCL necessary internal connection , wooden/steel racks suitable for kept at powerhouse including Automatic Floatt cum boost ( 20AMPS) Battery charging equipment SCR controlled suitable for 30Volts 100 AH VRLA batteries
Note- (i) Auxiliary Supply Voltage for the Relay/Close/Trip coil 30 Volt DC. (ii)-proposed VCB shall be fixed with exsisting VCB panel with all necessary extension of busbar chamber . Rate is inclusive of extention of busbar chamber
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Panel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :– Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (Location - Main Panel near Transformer)
a) Bus bar made out of Aluminium flat of capacity 1200 Amps- 3 nos for phase and 1200 Amps 1 no for neutral - 01 Set
(c)MCCB 630 A 35 KA, 3 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no-CM94104OOT1OG /Legrand cat no-025540/Schneider cat no-LV540310- 2 nos (AMF Panel (1) & spare)
(d) MCCB 400 A 35 KA, 4 POLE ,thermal magnetic release, Ics=100% Icu & L&T cat no-CM98401OOROOG /Legrand cat no-4220 60/Schneider Cat No-LV540309 -01 No. (APFC Panel)
(g) Indicator lamp LED (RYB) Cat Part No 1SFA611400R1001 of ABB or equivalent in L&T/Indo Asian/Legrand - 3 Nos
(h) Electronic energy trivactor meter,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240V AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), with optical port,deficiency metering with either phase/netral current, IP 51 protection, as per IS13779,, L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalent of secure - 01 No each.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, outdoor type, LT Pannel Board outdoor type made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and testing after installation including complete all as specified and comprising of the following :– (utility DG Panel )
(a) Bus bar made out of Aluminium flat of capacity 1000 Amps- 3 nos for phase and 1000 Amps 1 no for netural - 01 Set
(b) MCCB 630 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94104OOT1OG /Legrand cat no-025540/schneider cat no-LV540310 I- No Incoming
(c) MCCB 400 A 35 KA, 3 POLE ,thermal magnetic release, Ics=100% Icu & L&T /Legrand /Schneider- 2 no (AC Plant & spare)
(d) (i) MCCB TP 250 Amps , 415Volts, 35KA ,3 POLE L&T CAT NO-CM92008OOM1OG/ LEGRAND CAT NO-420087 / equivalent of ABB -01 No. (auditorium buliding Panel) (ii ) MCCB TP 160 Amps , 415Volts, 35KA ,3 POLE L&T CAT NO-CM92008OOM1OG/ LEGRAND CAT NO-420087 / equivalent of ABB -01 No. ( Fire Fighting Panel)
(e) MCCB 32A 415V TP, 10 KA - 03 Nos ( street light , water supply & FF Booster panel)
(h) Indicator lamp LED (RYB) Cat Part No 1SFA611400R1001 of ABB or equivalent in L&T/Indo Asian/Legrand - 3 Nos
(j) Astronomical, Multifunctional digital time swithces Cat Part No 2CSM204365R1341 of ABB or equivalent in L&T/Indo Asian/Legrand 1 No
(k) Power contactor ML-3 , 3 pole rating not less than 40 A with 230 coil make L&T/SEIMENS- 1 No.
Supply, installation, testing and commissioning of outdoor type 1200 A sandwich type silver flashed, bi-metal copper contact, aluminium busway (3L + N + PE), with original Mylar insulation from Dupont, 100% neutral, 50 kA for 1 second, 50% integral earth, dual housing complete all as specified and directed. Make: Schneider, ABB, Siemens
The busbar trunking system shall conform to the following technical specifications:
[A] General:
[i] The busbar trunking system (BTS), both feeder and plug-in, shall be of sandwich construction. All components and fittings (straight length, elbow, tees, flanged ends, cable tap box and circuit breaker, etc.) shall be in accordance with IEC 61439 Part 6 (2012) or UL857 and from the same manufacturer as the busbar trunking system. degree of protection BTS shall be IP 66 for outdoor application in accordance with IEC 60529.
[ii] Rated operation voltage of the BTS shall be 1 kV. The neutral conductor shall have the same cross-sectional area as the phase conductor. The earth busbar must be one continuous piece without bolting on housing.
[B] Certificate:
[i] The busbar, of full range and each rating, shall pass full type tests specified in IEC 61439-6. The certificate shall be issued by an international independent testing authority (e.g. ASTA, KEMA, UL).
[ii] A product safety mark (e.g. KEMA-KEUR, ASTA DIAMOND, UL) shall be on the product offering a visible assurance to all of full product safety testing, factory inspection and ongoing surveillance under independent authority to ensure the ongoing safety of product.
[iii] The BTS shall pass seismic tests with actual physical product and being certified complying with UBC seismic Zone 4 condition by an international recognized earthquake research body, e.g. Asian Pacific Network of Centers for Earthquake Engineering Research (ANCER).
[C] Short-Circuit Ratings & Tests:
[i] The whole BTS shall be capable of withstanding the short circuit of the electrical installation without undergoing any electrical, mechanical and thermal stress under fault condition at a service voltage of 1 kV at 50 Hz frequency. The minimum rated insulation voltage shall be 1 kV.
[ii] Minimum certified short circuit ratings shall be 198 kA peak and 90 kA for 1 s for 3200 A BTS.
[D] Housing:
[i] The busbar trunking housing shall be constructed of electro galvanized steel and aluminum to reduce hysteresis and eddy current loses and shall be provided with a suitable protective finish of ANSI 49 grey epoxy paint.
[ii] The busbar trunking housing shall be totally enclosed non-ventilated for protection against mechanical damage and dust accumulation. And it shall pass at least 2000 hr salt spray test to ensure the anticorrosion ability.
[iii] The totally enclosed housing shall be manufactured by the busbar trunking manufacturer. Modifications of busbar trunking to make it totally enclosed by housing other than the busbar trunking manufacturer voids the manufacturer’s warranty. Busbar trunking so modified is unacceptable without the written consent of the manufacturer.
[E] Busbars:
[i] Busbars shall be of aluminum with copper cladding utilized Molecular Fusion technology.
[ii] There shall be no bolts passing through the busbars of the busway.
[iii] Each busbar shall be insulated with Class B (130 ℃) DuPont Mylar insulation. Epoxy insulation is unacceptable.
[iv] The temperature rise at any point of the busbar trunking enclosure shall not exceed 55° C above the ambient temperature of 40° C when operated at rated current.
[F] Joints:
[i] The busbar trunking joint shall be of the one-bolt type which utilizes a high strength steel bolt(s) and Belleville washers to maintain proper pressure over a large contact surface area.
[ii] The bolt shall be torque indicating and at earth potential.
[iii] The bolt shall be two-headed design to indicate when proper torque has been applied and require only a standard long handle wrench to be properly activated.
[iv] Access shall be required to only one side of the busbar trunking for tightening joint bolts.
[v] It shall be possible to remove any joint connection assembly to allow electrical isolation or physical removal of a busbar trunking length without disturbing adjacent busbar trunking lengths.
[G] Plug-in Openings:
[i] The connecting jaw of the plug-in unit shall plug directly on to the busbar and have full contact with busbar itself. Welded tab at plug-in busbar is unacceptable.
[ii] All contact on joint and plug-in opening should be silver plated copper.
[iii] On plug-in busbar trunking there shall be three dead front, hinged cover type plug-in openings on each side.
[iv] All openings shall be usable simultaneously.
[v] Busbar trunking shall be installed so that plugs are side mounted to permit practical use of all plug-in openings.
[vi] It shall be possible to inspect the plug-in opening and busbars prior to the installation of the plug-in units.
[H] Plug-in Units:
[i] The plug-in jaw shall be spring design composed of different metal to ensure the firm and tight contact with the busbar.
[ii] Plug-in Units shall be type tested in accordance with IEC 61439-6 (Annex D: Part 1-5 and 9-13).
[iii] The earthing contact of the plug-in unit shall always be made before that of the live conductors and the last to break during removal. And it must connect to the earth bar of busway to ensure the safety.
[iv] Covers of all plug-in units must have interlocks to prevent the cover from being opened when the switch is in the ON position.
[v] Plug-in units (circuit breaker type or fusible switch type) shall be operated with visible blade quick-make and quick-break mechanism.
[vi] Presence of transparent shield shall be inside to avoid direct contact of human.
[vii] The plug-in units shall be equipped with internal barriers to prevent accidental contact of fish tape and conductors with live parts on the line side of the protective device during time of wire pulling.
[J] Supporting Structure:
Indoor feeder and plug-in busbar trunking shall be approved for hanger spacing of up to 3 meters for horizontally mounted run and 4.88 meters for vertically mounted runs. Outdoor feeder busbar trunking shall be approved for spacing of up to 1.5 meters for horizontally or vertically mounted runs.
[K] Voltage Drop:
[i] The 3-phase line to line voltage drop 40% power factor concentrated load shall not exceed 3.4 V per hundred ft.
[ii] The line-to line voltage drop at the load power factor shall not exceed 4.1 V per hundred feet.
Straight feeder
90º elbow
Flange end
Copper flexible (braided)
Adopter box (local item)
Edge-wise hangers
Straight feeder
90º elbow
Flange end
Copper flexible (braided)
Adopter box (local item)
Edge-wise hangers
Supply and fixing 60 watt LED roadway luminarie, made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection with high power LEDs as light source and HF electronic driver of 90W capacity including making necessary connection complete all as specified and directed. Make : Bajaj cat No. BRTFG 60W LED I/Havells cat no-ENDURAPEARLPLUSSL60WLED757SASYTOPC/Crompten cat no-LSTP-60-CDL
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, outdoor type , double door, APFC capacitor bank Panel Board of size as recommended by manufactrer 120 KVAR with 8 steps (25+25+25+12.5+12.5+10+5+5) WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 3.15 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprosing of following. Make of pannel L&T/ SCHNEIDER/ABB
Particulars
INCOMER
MCCB 400 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM94105OOR1OG /Legrand cat no-025538/schneider cat no-LV540309 -01no
ROM+SPDR - 1 no
Auxiliary 1 c/o +TAC 1 c/o- 1 no
OUTGOING CAPACITOR FEEDERS : -
25 KVAr Capacitor feeder comprising of:- ( 3 Nos. )
80A, BUSSMANN FUSE 80ET,-9 nos
Thyristor switching module 25kVAR, 440V , TSM,LTTSM-3 nos
7% Detuned Aluminium Reactor 25KVAr 440V-3 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 30 kVAr,sutable for 480V , LTXL - 3 NOS
Push Button ON/OFF -6nos
Indicating lamps 6 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 3 NOS
12.5 KVAr Capacitor feeder comprising of:- ( 2 Nos. )
40A, BUSSMANN FUSE- 6 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM - 2 NOS
7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 15 kVAr,sutable for 480V - 2 NOS
Push Button ON/OFF -4nos
Indicating lamps 4 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
10 KVAr Capacitor feeder comprising of:- ( 1 No. )
40A, BUSSMANN FUSE- 3 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM -1 NOS
7% Detuned Aluminium Reactor 10 KVAr 440V LTAL,CAT NO-0712B2- 1 NO
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 12.5 kVAr,sutable for 480V - 1 NO
Push Button ON/OFF -2nos
Indicating lamps 2 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 1
6A DP MCB , C CURVE 1NOS
5 KVAr Capacitor feeder comprising of:- (2 Nos. )
16A, BUSSMANN FUSE 6 nos
Thyristor switching module 10kVAR, 440V,TSM,LTTSM - 2nos
7% Detuned Aluminium Reactor 5 KVAr 440V,LTAL,CAT NO-0712B2-2 no
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 7.5 kVAr,sutable for 480V ,LTXL- 2nos
Push Button ON/OFF -4nos
Indicating lamps 2 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
Incomer Metering
APFC relay 8 stage {BLR CM – 06T MB } -1 NO [230/ 110 V, 1/5A, 50 Hz] [Transistor output + Single CT sensing + RS 485 MODBUS]
Digital Voltmeter (3Ph, Class 1) -1 NO
Digital Ameter (3Ph, Class 1, 5A) -1 NO
Metering CT --/5A, Class-1- 3 NOS
SMPS 5A, Input 230V AC Output 24V DC -1 NO
ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
Auxiliary Contactor {4NO} with 24V DC}-3 NOS
Indicating Lamp(R,Y,B)-3 NOS
6A SP MCB-3 NOS
6A DP MCB
6A FP MCB -1 NO
8" {EBM NADI} Fan -1 NO
S&F decorative type 35/40W LED Post Top Lantern luminaire made of cast aluminium spigot housing with decorative clear opal acrylic diffuser Light fitting IP 65 protection complete includung GI pipe light grade for mounting the fitting all as per directed by Engr-in-Charge Make : Bajaj cat No. -BGCT W4 LED WW / Crompton cat no-LTPO-40CDL / Havells cat no- RUBYPT35WLED757PSYMTOPC/or equivant of Philips.
S & F LED Bolard light fittings 8/9/10 Watt integral decorative with opal acrylic cone series ip 65 protection, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size & PCC foundation 30cmx30cmx45cm height etc. Make : Bajaj cat No. -BGBOM6509WLEDW/Crompton cat no-LBLTW10WW/ Havells cat no- CONEBL8WLED757PSYMTOPC/or equivant of Philips.
S&F in repairs FRP cable looping boxes of size 300 mm x 200 mm x 105 mm with TPN aluminium busbar and MCB SP 6 Amp- 01 No, 10 KA breaking capacity, C curve series, factory made with PVC sheet including heavy duty connector for connection of 4 core cable & fixed to pole with suitable size flat iron clamp, nuts & bolts complete all as specified and directed by Engr-in-Charge. Make :Sintex or as approved by GE
Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified and directed by Engr-in-Charge.
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified and directed by Engr-in-Charge.
Supply and fixing 60/65 watt LED roadway luminarie, made up of spun aluminium housing for lamp and reflector assembly with clear polycarbonate cover and IP65 protection with high power LEDs as light source and HF electronic driver of 60/65W capacity including decorative hot deeped galvanised mild steel pole 7 meter long with black powder finised making necessary connection complete all as specified and directed. Make : Bajaj cat No. -BNRRL 65 LED /Crompton cat no- LPTE-60-CDL and equivant of Havells/ Philips.
S&F decorative type 45/35W LED Post Top Lantern luminaire made of diacast aluminium housing with decorative clear toughned glass difuser Light fitting IP 65 protection complete includung including decorative hot deeped galvanised mild steel pole 3 meter long with black powder finised all as per directed by Engr-in-Charge Make : Bajaj cat No. -BRIL 45 LED NW/Crompton cat no-LPTOI-45CDL/ Havells cat no- ENDURASPRING6PT35LED757PSYMTOTG/or equivant of Philips.
Supply and fix M & L Hot dip galvanised Iron octagonal pole of height 6 mtrs minimum galavnising of 70 microns, top 70 mm , bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm foundation bolts, single arm GI bracket of 900x1000 mm for mounting the light fitting at an angle of 120 degree,backelite sheet with one 6 A SP MCB and 16 mm stud type connectors -04 nos inside the pole at the door opening for cable connections,common template s minimum 01 for each 15 poles all fixed and bolted on and incl suitable PCC pedestal as per manufacturers recommendations and specifications all as directed Mast and pole shaft shall be be as per BSEN 10025,IS 5986, ASTM A572 , Foundation as per IS-2062 Galvanization as per IS-4759/2629 Make of pole- Bajaj / Jindal /Crompton/Shubham-
ACOUSTIC SYSTEM
Material and labour for Accoustic wall panelling at auditorium hall upto 2.1 m height shall be channelled works perforated panels of width 128mm, thickness 15 mm and length 2440 mm or as directed by GE made of a high density fibre board with minimum 830 Kg/M3 density substrate with a laminated facing/wood veneer as per the approved shade/species & finish and a melamine balancing layer on the reverse side. The boards shall have a G14/G28 perforation pattern where the visible surface has a “Helmhoitz” fluted perforation of 2 mm/4 mm width and 14 mm/28 mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of not less than 0.70. The panel shall be mounted on special aluminium splines using clips provided by and approved by the GE. This type of wall panelling shall be provdied upto 2.1 m height towards stage.
Material and labour for Accoustic wall panelling at auditorium hall above 2.1 m height over wall profie shall be acoustical wall panelling with square edges made of fibre glass substrate 25 mm thick and wrapped on the front side an acoustically transparent and classified for the fire reaction class A as per ASTM E-84 fabric with an option of colours - Husk Copper, Sangeria, Seasame, Coffee, Charcoal, Titanium, Flame, Peanut as approved by GE of size 600 x 1200 mm providing a minimum sound absorbtion level of not less than 0.85 NRC to be affixed to wall using wall panel impellers and construction adhesives as per the instructions laid down by the manufacturers” Note for item No 24.01 & 24.02 : (i ) Installation : 4 Nos wall panel impellers shall be fixed to the wall surface using self tapping scews. Silica based construction adhesive to be dabbed on to the projecting elements (Spikes) of the impellers. (ii) Before incorporating the above items in work, the contractor shall get accoustic design of the auditorium through an expert in the relevant field having experience/ Govt. Engineering College and will get approval of GE. The rates quoted shall be deemed to be inclusive of above factors and no extra charges will be admisible (iii) Makes : Anutone, Armstrong, Ramco Hilux and Himalayan Asociates
Material and labour for Providing false ceiling ( Absorptive Type ) work at all heights comprising as under : (a) Framework of GI Sections roll formed from Galvanised sheet consisting of sofit cleat, at 1200mm c/c, once flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50 mm which is fixed with intermediate GI chanels 45 x 15 x 0.90 mm running at the spacing of 1200 mm c/c, to which ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm, at 450 mm c/c, shall be fixed in a direction perpendicular to GI intermediate channel with connecting clip made out of 2.64 mm dia x 230 mm long GI wire at every junction, including fixing perimeter channels 0.50 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partitions with the help of Rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval. (b) Acoustic Tiles : Providing and fixing of 8 mm fully perforated Calcium Silicate Board to ceiling Section and perimeter channels with the help of dry wall screws of size 25 X 6 mm at 230 mm c/c, including jointing & finishing to get flush finish to tapered and square edges of the board with joining compounds, joining tapes, and two coats of primer suitable for boards, also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting. Make : Anutone, Armstrong, Ramco, Hilux, Saint Gobain, Samceil (c) Backing : The system shall also include a backing of 50 mm thick rockwool of 48 kg/M3 density as backing on framework.
Material and labour for Providing false ceiling (Reflective Type) work at all heights comprising as under : (a) Framework of GI Sections roll formed from Galvanised sheet consisting of sofit cleat, at 1200mm c/c, once flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50 mm which is fixed with intermediate GI chanels 45 x 15 x 0.90 mm running at the spacing of 1200 mm c/c, to which ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm, at 450 mm c/c, shall be fixed in a direction perpendicular to GI intermediate channel with connecting clip made out of 2.64 mm dia x 230 mm long GI wire at every junction, including fixing perimeter channels 0.50 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partitions with the help of Rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval. (b) False ceiling board : Supply and fixing of 12.5 mm fully thick gypsum board in ceiling suitably placed in false ceiling grid including two coats of primer suitable for boards complete all as specified and as directed. Make for gypsum board: Armstrong, Ramco, Hilux, Saint Gobain , Samceil
"AIR CONDITIONING SYSYEM"
Supply, Installation, Testing & Commissioning DX type Air Cooled Scroll Chillers/ condensing Unit with Single / Multiple Compressor of Open Type Motor, Starter Panel machine mounted, Air cooled condensor with anti corrosion coating on condensor coil, Insulated Chiller, vibration isolators, integral Refrigerent piping & wiring, accessories Microprocessor Based Control Panel & all mounted on a steel frame complete as per specification capacity as below :-
(a) Motor shall be sutiable for 415V +/- 15%, 50 C/S, 3 Phase, AC supply.
(b) Refrigerent used shall be R134a/ R407c/ R22 as mentioned in specifictions.
(c) Chiller
(d) Chilled Water Inlet Temp. 12o C
(e) Chilled Water Outlet Temp. 7o C
(f) Fouling Factor 0.0005 FPS.
(g) Condenser
(h) Inlet Air Temp to the Condensor. 38o C
(j) Capacity upto 74 TR Each. (2 working+ 1 stand by )
Make : Blue Star Model No XAC2YS-080AR2 Or equivalent model of make : Daikin / Carrier
M & L for Centrifugal back pull out end suction pump set Energy Efficient having cast iron body, bronze impeller, shaft seals, with driven by squirrel cage induction motor suitable for 3 Phase, 415V +/- 10%, 50 Hz power supply mounted on common base frame with required insulation.
(a) Water quantity - 13 LPS @ 24 Mtrs Static Head , Motor rating 7.5 HP
(b) (2 Working + 1 Stand by) Make : Kirloskar Model No. KDI 830 or equivalent in CG/ Groundfos
Supply, Installation, Testing and Commissioning of Double Skin Type Floor mounted Air Handling Unit as per specification mentioned below :-
(a) Floor mounting, Cabinet PUF insulated, Sanwich panel of 40mm thick, 40Kg/cum Density, SS drain tray, 6 Row Deep Chilled water Cooling Coil having Coil face velocity which should not exceed more than 500 FPM with coil section, DIDW forward / Backward curved centrifugal fan, door limit switch, non flammable Pre filter of 10 micron as a single stage filter, supply air Damper, vibration isolator, Fan Drive motor, TEFC suitable for 3 Phase, 415 V, 50 c/s, AC supply, Belt Drive package, Flexible Connection etc complete as specified & directed.
(b) Outer skin - 0.63mm thick plain GSS.
(c) Inner skin - 0.63mm thick pre-coated GSS.
(d) 30000 CFM, 50mm TSP Model No. ZDS300 Make ZECO or equivalent of make BlueStar / Carrier.
Supply, Fabrication, Erection, Testing & commissioning of M.S.ERW 'C' Class pipe of 100mm dia conforming to IS : 1239/3589 Heavy Class Including all fittings like Bends, Elbows, tees, anchors fasteners, Pipe Supporting, supported by rigid PUF block / Wooden Gatti etc. The entire chilled water piping shall be insulated with 50mm Thick TF quality Thermocol applied by hbot bitumen and covered by polythene sheet as vapour barier. This Insulation should be Finally covered with Aluminium Cladding of 26 guages Sheet with Self Tapping Screws etc complete as specified & directed. Make : Zindal / Tata Steel
Supply, Fabrication, Erection, Testing & commissioning of M.S.ERW 'C' Class pipe of 80mm dia conforming to IS : 1239/3589 Heavy Class Including all fittings like Bends, Elbows, tees, anchors fasteners, Pipe Supporting, supported by rigid PUF block / Wooden Gatti etc. The entire chilled water piping shall be insulated with 50mm Thick TF quality Thermocol applied by hbot bitumen and covered by polythene sheet as vapour barier. This Insulation should be Finally covered with Aluminium Cladding of 26 guages Sheet with Self Tapping Screws etc complete as specified & directed. Make : Zindal / Tata Steel
Supply, Fabrication, Erection, Testing & commissioning of M.S.ERW 'C' Class pipe of 25 mm dia conforming to IS : 1239/3589 Heavy Class Including all fittings like Bends, Elbows, tees, anchors fasteners, Pipe Supporting, supported by rigid PUF block / Wooden Gatti etc. The entire chilled water piping shall be insulated with 50mm Thick TF quality Thermocol applied by hbot bitumen and covered by polythene sheet as vapour barier. This Insulation should be Finally covered with Aluminium Cladding of 26 guages Sheet with Self Tapping Screws etc complete as specified & directed. Make : Zindal / Tata Steel
Supply and fixing of C-1 Non return Valves 80mm dia with matching flanges gasket hardware etc. duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 26SWG Aluminium sheet cover should be divided into protions etc complete as specified & directed. Make : Danfos / Castle / Keystone/Zoloto
Supply and fixing of Balancing valves 80mm dia with matching flanges gasket hardware etc. duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 26SWG Aluminium sheet cover should be divided into protions. Make : Danfos / Castle / Keystone/Zoloto
Supply and fixing of 3-Way Mixing valve 65mm dia alongwith modulating actuator, Thermostat, matching flanges gasket hardware etc. duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 26SWG Aluminium sheet cover should be divided into protions. Make : Siemens / Sauter
Supply and fixing of CI Y strainers of size 80mm dia with matching flanges gasket hardware duly insulated with performed pipe section fabricated to shape and bonded with Adhesive / Bitumen. Removable cover is required for valves and flanges in 20SWG Aluminium sheet cover should be divided into protions. Make : Danfos / Castle / Keystone/ Zoloto
Supply and fixing of Expansion Bellow size 80mm dia with matching flanges gasket hardware.
C.I.Ball Valves for Drain Valve of size 32mm Dia. Make : Danfos / Castle / Keystone/ Zoloto
C.I.Ball Valves for Drain Valve of size 25mm Dia. Make : Danfos / Castle / Keystone/ Zoloto
Supply, Installation, Testing and Commissioning of G.I.B drain piping of size 32mm dia with elbows, bends, tees, cleanouts etc. With elbows, bends, tees, cleanouts etc. with 25mm Thick TF quality Thermocol insulation and covered with 26G Aluminium Cladding. Make : Jindal / Tata / Zenith
M&L PVC Rigid Drain water piping of size 40mm dia.
M&L Auto Air Purge valve 20mm dia. Make : Anergy / Rapid Control
M&L Pressure Gauge 4" Dia Dial Type with shut off valve 0 to 10 Kg / Sqcm. Make : Waree / H.Guru
M&L Stem type vertical Thermometer Type 0o C to 50o C. Make : Emerald / H.Guru / Taylor
Supply and installation of flow Switch at chiller outlet. Make : Kele
M&L for HDPE TANK 500 liters, with all accessories, float valve, drain etc. and covered with 50mm Thick TF quality Thermocol and finished with 26G aluminium cladding. Make : Sintex / Polycon
Supply and installation of Accoustic insulation on supply air ducts with 25mm glaswool rigid board of 48 kg/cum density, RP tissue paper covered with 0.63mm thick perforated aluminium sheet.
Supply and Installtion Aluminium powder coated supply and return Linear grille. Make : Air Master / Air Product / Dynacraft
Supply, Fix and Installatin of Aluminium Box Type Collar Dampers. Make : Air Master / Air Product / Dynacraft
Supply and Installation Volume Control Dampers in GSS construction. Make : Air Master / Air Product / Dynacraft
Supply and Installation Fire damper with necessary arrangement for Fusible Link. Make : Air Master / Air Product / Dynacraft
M&L Fresh air arrangement comprising volume control damper, cowl piece and with bird screen. Make : Air Master / Air Product / Dynacraft
M&L powder coated Electrical panel of size 1900x1900x400mm made of 2 mm CRCA Sheet metal, Cubical type, dust/vermin proof, Floor mounted Shaded IS-7032, powder coated, Protectin IP-5X.
(A) Incoming
(i) 315 A TP MCCB 25KA Type D-Sine, Make L&T-01 No
(ii) 500A TPN copper Busbar-01 No
(iii) 0-500V Volmeter, Type-Digital-01 No
(iv) 200/5A Ammeter, Type-Digital-01 No
(v) 200/5A C.T.'s, Type-Digital-10VA, Qty-3 Nos
(vii) Controller MCB, Type-SP 2A, Qty-3 Nos
(viii) Indicating Lamps R Y B, Type LED -3 Nos
(B) Outgoing
(i) 60 KW Chiller - 03 Nos (2W + 1 S By)
(ii) 160A TP MCCB 25KA -03 Nos
(iii) Spreader Terminal Link - 03 Nos
(iv) 5.5 KW DOL Pumps - 03 Nos (2W + 1 S By)
(v) 32 A TP MCB, class 'C', 10KA - 03 Nos
(vi) 2 A Control MCB, Type SP - 03 Nos
(vii) 18 A Contractors, Type-MNX 18 - 03 Nos
(viii) Add On Block, Type-MX, Qty - 03 Nos
(ix) Overload Relay (9-15A), Type-MN-2, Qty - 03 Nos
(x) Push button with Elements, Type-22.5D, Qty - 06 Nos
(xi) Indicating Lamps, Type LED, Qty - 06 Nos
(xii) Terminals, Type-Clipon, Qty - 03 Nos
Supplying & Fixing Starter panels for AHUs Size 800x600x200 mm made of 14SWG CRCA Sheet metal, cubical type, dust / vermin proof, Floor mounted shaded IS-7032, Powder coated, Protection IP-5X
(i) 7.5 KW AHU Panel
(ii) 160 A TP MCCB - 01 No
(iii) 2 A Control MCB, Type SP - 01 No
(iv) 22 A Contractors, Type-MNX 80 - 03 Nos
(v) Add On Block, Type-MX, Qty - 03 Nos
(vi) Overload Relay (12-18), Type-MN-1 No
(vii) Timer, Type-800S-1 No
(viii) Control Transformer 30VA, Type-230/24V-1 No
(ix) Push button with Elements, Type-22.5D, Qty - 02 Nos
(x) Indicating Lamps, Type LED, Qty - 03 Nos
(xi) Terminals, Type-Clipon, Qty - 01 No
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) [ Air Conditioning 6 nos + 8 nos Lightning protection +18 Ext Elect NOTE-: GI earth strip shell be measured and paid for separately under relevant item of schedule .
Supply & Laying cable from each AHU panel in AHU room to main AC plant panel 3 core x 1.5 sq.mm.
S&F welded steel wire cable tray in 50x100mm mesh configuration produced from lateral and longitudinal side walls, steel wire with minimum diameters as specified, with all standard fittings / fixtures / couplers as recommended by the manufacturer and fixed to walls / ceillings as per site requirements of size 150mm wide & 54mm high. Make : Asian / Profab Engineers / Indian
Supplying & Fixing Thermal insulation on False celling / wall panelling with 50mm thick, 24Kgs/M3 density Glass Wool in roll form, sealed in polythene bags etc complete as directed. Make : Twiga
Supplying & Fixing Under decl Insulation in 20mm thick pre insulated polyisocyanurate sandwhich panels with density of foam 38kg/M3 & embossed with 60 micron aluminium foil including necessary fittings fixtures etc complete as directed.
"AUDITORIUM CHAIR LIGHTS (SPECIAL LIGHTS)"
12V LED power supply for the LED booster amplifier. Make Custom Brand
Supply and fixing LED Step light in white powder coated cast aluminium body with IP-65 protection,3/4 watt in duly powder coated aluminium die cast housing. IP65. Bajaj/Halonix / HPL/Philips.
Supply and fixing Single sided LED signage with built in battery back-up for 2 hrs. LED Entry/ Exit sign light ,3 watt in CRCA powder coated with clear acrylic, screen printed/ etching /deep engraving display. Bajaj/Halonix/havells/HPL/Philips.
LED controller with Remote. Make "Illumax" Brand
Supply and fixing chair LED light , suitable for 12v supply with .IP 20. Crompton/Havells/HPL/Philips.
"STAGE LIGHTING"
MODULAR WIRED FIXED HEAVY-DUTY STAGE LIGHTING BAR SYSTEM MAKES RIGGING LIGHTS QUICK AND EASY WITH POWER OUTLETS BUILT INTO THE BAR FOR LIGHTING APPLICATIONS.: Over Head Light Bar fabricated with Steel Rectangular Tube 4" x 4" x 16 Gauge dia pipe of full length interlocked with 2"inch square pipe lincked with 2"inch round pipe for trussing with adequate clamps, bars can be linked together side by side to form a single rigid bar, bar can be hung from wire ropes, chains or hung from an existing grid this lighting bar painted in side, outside with zinc chromate primer finally coated with black quick drying enamel paint to mounting for stage lighting, which is suspended from bars above the stage to focus/Wash the stage. Make -Canara/ Stage Works/ Illumitex/ Effectron
Truss FOH “FRONT OF HOUSE” LIGHT BAR: 40NB dia pipe of full length trussing with adequate clamps, this lighting bar painted in side, outside with zinc chromate primer finally coated with black quick drying enamel paint required which is suspended from ceiling in front of stage to focus stage. 36ft Length.Make -Canara/ Stage Works/ Illumitex/ Effectron
Side Ladder: S&f of the side ladders made out of 50x25mm MS tube pipe size: 4x2 ft.
350w17R super beam moving head light double prisms(rainbow effects), glass gobos. oltage, AC100-240V 50/60Hz Power consumption: 500W Light Source: PHILIPS 350W lamp Ballast: Electronic Ballast Channels: OMX 18/22 Channels Color wheel: One color wheel, 13 colors + open Gobo wheel: One static gobo wheel, 13 gobos+ open Prism: Two rotating prism, One 16-facet prism and one 32-facet prism Frost: Gradually frost, wash angle 5-30 degree Strobe: 0.5-14/c variable strobe effect Lens: Glass optic lens, linear zoom 0-20 degree Movement: Pan 540 degree, 8/16 bit resolution Tilt 270 degree, 8/16 bit resolution Pan/Tilt movement auto repositioning function. Auto reset when mis-positioned. Three motor makes movement quicker, smoother and more mute. IP Grade: IP20 Make -Canara/ Stage Works/ Illumitex/ Effectron
19x15W LED Zoom Moving Head Wash Light Zoom: 12-60degree Voltage / frequency: AC100-240V, 50-60Hz. Rated power: 230W. Light source: 19 high brightness and high power 15W LED lamp beads. Lamp life: about 60,000 hours. Color: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216 color changes. Focusing angle: 12-60 degrees. Control channel: 16CH. Operating mode: voice control, self-propelled, masterslave, DMX512 Display interface: LCD display in Chinese and English. Dimming: 0-100% linear dimming. Strobe: 1-20 times/second ultra-high speed strobe effect. Horizontal scanning 540 degrees (16bit), vertical scanning 270 degrees (16bit), fast, no jitter, no noise, accurate positioning. Protection level: IP20. Performance characteristics: a variety of built-in program effects Make -Canara/ Stage Works/ Illumitex/ Effectron
54X3W Indoor RGBW slim LED Par, Aluminum Die Cast Make -Canara/ Stage Works/ Illumitex/ Effectron
54X3W Indoor Warn White Slim LED Par Aluminum Die Cast Make -Canara/ Stage Works/ Illumitex/ Effectron
54X3W Indoor UV slim LED Par Aluminum Die Cast Make -Canara/ Stage Works/ Illumitex/ Effectron
200w COB Par LED with barndoor 1x200W warm white+white 2in1/warm white/white Voltage: AC110- 220V, 50-60HZ Power: 100W/200W Light source: 100W COB/200W COB Color: warm white, white Dimming: 0- 100% Control mode: voice, master and slave, self-propelled, DMX512 Channels: 4 / SCH Working temperature: -30 "C -40 "C +RGB Make -Canara/ Stage Works/ Illumitex/ Effectron
200W cob led studio par light with zoom Input Voltage: AC100-240V, 50-60Hz Power Consumption: 250W LED Quantity: 1 PCS 200W cool white or warm white LEDs Color Rendering Index: (CRI) Ra>90 Zoom angle:10 ° to 90 ° Control Signal: DMX512, master-slave, sound, auto mode Control Channels Make -Canara/ Stage Works/ Illumitex/ Effectron
4 eyes cob led blinder light 100W Voltage / frequency: AC100V-240V/50-60Hz. Rated power: 430W. Light source: 4 ultra-high brightness COB 1 DOW two-in-one LED. Lamp life: about 50,000 hours. Color: Warm white or white or 2-in-1. Color temperature: 3200K - 5600K can be adjusted. Control channel: 8 channels. Light angle: 35° . Dimming: 0-100% linear electronic dimming. Strobe: Independent high-speed electronic strobe, 1-13 times per second. Operating mode: voice control, self-propelled, masterslave, DMX512. Color rendering index: Ra>85 Waterproof rating: IP20 Make -Canara/ Stage Works/ Illumitex/ Effectron
200w fresnel light with barndoor Input voltage: AC100-240V, 50/60Hz Power: 220W Light source:100W/150W/200W high indicates COB LED lamp. Color rendering index: Ra>95 Light source life: 100000 hours Color temperature: 3200K, 5600K optional. Control panel: LCD liquid crystal display + four buttons Beam angle: 15-60 degrees Manual zoom Dimming: 0-100% linear dimming. Cooling method: copper radiator. Channel mode: 1 CH/2CH. Control mode: DMX512 control/manual control. Protection level: IP20 Working temperature: -25° C- +45° C Shell Material: Aluminum Alloy Accessories : Concealer, power cord, signal cable Make -Canara/ Stage Works/ Illumitex/ Effectron
200W LED profils Input Voltage: AC100-240V, 50/60Hz Power Consumption: 260W LED POWER: 200W LED Quantity; 1 PCS 200W white or warm white LED Color Temperature: 3200K or 5700K color temperature Color Rendering Index: (CRI) Ra>90 Beam Angle: 19° (26° /36° also available) Control Signal: DMX512, master-slave.auto mode Control Channel: 1/3CH DMX512 channel Product Dimensions: 550•270•185m Make -Canara/ Stage Works/ Illumitex/ Effectron
LED 400W Strobe Voltage: AC 110 -220V 50-60HZ Signal: 512 Controllable Self-propelled Control channel: 5 channels Can match the brightness of 3000W Light source: 8 25W imported lamp beads, RGBW optional Make -Canara/ Stage Works/ Illumitex/ Effectron
200W LED COB Profile Spot Beam angle 15-60 degree optional Make -Canara/ Stage Works/ Illumitex/ Effectron
Follow spot 7R Input voltage / frequency: AC220V ± 10% / 50-60Hz. Rated power: 250W/280W. Light source: Use a 200W/230W cup. Beam angle: 15° . The combination of new aluminum alloy and die-cast steel plate is beautiful and elegant. Manual focus adjustment. The aperture size is adjustable. Adjust the strobe manually. color: White. Protection level: IP20. Make -Canara/ Stage Works/ Illumitex/ Effectron
6eyes Red Laser Beam Bar Light, Laser power: 3000mW (500mW*6PCS) Input voltage / frequency: AC100V-240V, 50/60Hz. Rated power: 120W Light source: 500mW red laser tube 6 Laser color: single red / single blue / single green color optional Cooling system: low noise air cooling Operating mode: voice control, self-propelled, masterslave, OMX512. Scanning system: stepper motor Scanning angle: ± 25 degrees Operating ambient temperature: 10-35° C Protection level: IP20. Features: long illumination distance, low power consumption, long life, uniform spot, simple operation and dazzling effect. Controllable via OMX Out of extraordinary magical lighting effects, 6 beams of light can be alone, horse racing, running water. Make -Canara/ Stage Works/ Illumitex/ Effectron
LED 1810W Non-waterproof Dot Matrix Voltage / frequency: AC100V-240V/50-60Hz Rated power: 180W. Light source: 18 ultra-high brightness 10W RGBW 4 in 1 LED, optional 24, 36. Lamp life: about 60,000 hours. Color: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216 color changes. Control channel: 4/8CH. Beam angle: 25 ° , 15, 45 degrees optional. Dimming: 0-100% linear dimming, no flickering, smoothing and softening. Strobe: Independent high-speed electronic strobe, 1-13 times per second. Control mode: DMX512, master-slave control, self propelled, voice control. Working environment temperature -20-45 ° C. Waterproof rating: IP64.Make -Canara/ Stage Works/ Illumitex/ Effectron
LED 108Pcs Spot Lights Voltage/ frequency: AC100V-240V/50-60Hz Rated power: 324W Light source: 108 ultra- high brightness 3W LED. Lamp life: about 60,000 hours. Color: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216color changes. Cmtrol channe:l 6CH. Beam angle: 15, 25, 35, 45 degrees optional. Dimming : 0-100% linear dimming, no flickering, smoothing and softening. Strobe: Independent high-speed electronic strobe, 1-13 times per second. Cmtrol mode: DMX512, master-slave control, se -propelled, voice control. Working environment temperature -20-45 ° C. Waterproof rating: IP64 Make -Canara/ Stage Works/ Illumitex/ Effectron
LED54/72/108/120Pcs Non-waterproof Flood Light Rated power: 250W Light source: 54/72/108/120 high brightness and high power 3W LED. Lamp life: about 50,000 hours. Color: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216 color changes. Dimming: 0-100% linear dimming. Control channel: 6CH. Beam angle:15, 25 degrees optional. Control mode: DMX512, master-slave control, self propelled, voice control. Protection level: IP20. Make -Canara/ Stage Works/ Illumitex/ Effectron
Splitter 8 channel 4/8 independent amplification driver output.The signal amplifying and shaping !unction, extending the signal transmission distance.To enhance the capacity of data bus access equip men! number. To protect the lighting console DMX512 output interface.fault isolation, improve the safety and reliability of digital lighting Make -Canara/ Stage Works/ Illumitex/ Effectron
Mini pearl 1024 lighting controller with flight case 1. Audio signal input 2. MIDI input or output 3. Via RS 232 System interface 4. DMX 512 signal 1024 channel Power supply: 25 V.DC 0.5A Make -Canara/ Stage Works/ Illumitex/ Effectron
DMX 3-Pin Male XLR – 3-Pin Female XLR DMX Cable: Supply, Installation, Laying, Testing & Commissioning of DMX Data Signal Point Wiring : Using 2-core PVC insulated 22AWG multi-stranded Cu.Cond. high speed data cable designed for EIA485 ; lowcapacitance, twisted pair shielded ; FHDPE insulation - starting from DMX Splitter to each Light Bar - either sides, Side Ladders and Floor Points, as required to be terminated with suitable XLR connectors Make -Canara/ Stage Works/ Illumitex/ Effectron
LIGHTING SAFETY HOOK Features Choose from multiple lengths and safety bond types Galvanised steel cable Black PVC coated Black steel cable Screw-gate carbine hook Shackle Designed and manufactured in the UK! Specifications Cable diameter: 3mm Working Load Limit (WLL): 25kg Make -Canara/ Stage Works/ Illumitex/ Effectron
Black Steel Hook: G CLAMP Strong metal G clamp fitted with protector strip designed for hanging light effects. Fits on bars up to 50mm diameter. Make -Canara/ Stage Works/ Illumitex/ Effectron
"WATER COOLER AND REFRIGERATION"
Supply, install and testing water cooler electric driven (single phase) having storage cap of 150 ltrs and nominal cooling cap of 150 ltrs per hours complete all as per manufacturers instructions and as directed. Make : Blue Star/ Voltas
Supply and install Hi wall split Air conditioning indoor/outdoor complete with cordless remote control unit and within built Air IONISER and plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of 2 TR capacity. Make : Daikin/ Voltas/ Blue Star
Supply and fix voltage stabilizer capacity of 5 KVA for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 volt with output voltage stabilzer at 230 v with accuracy of + 2.5 % including high/low voltage cut out and time delay relay complete all as specified and directed.
Supply and fix voltage stabilizer capacity of 2 KVA for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 volt with output voltage stabilzer at 230 v with accuracy of + 2.5 % including high/low voltage cut out and time delay relay complete all as specified and directed.
" FURNITURE"
Supply and fix in position chair high back Model Jupiter PCH2342IX (or its latest model) of Make: Godrej or equivalent in Durian, Methodex, Fetherlite as approved.
SERVICES FOR COMPREHENSIVE MAINTENANCE OF AC PLANT
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of chilled water type central air conditioning plant of capacity 3 x 75 TR installed, comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below: at Auditorium Karwar
1st year after expiry of defect liability period.
2nd year after expiry of defect liability period.
3rd year after expiry of defect liability period.
SERVICES FOR MANNING & OPERATION OF AC PLANT
Outsourcing of services for 2 shifts ( consisting of two shifts) including Sundays and holidays and operation of Central type air conditioning plant of capacity 3 x75 TR ( Two plants each to be run at a time and one will be kept as stand by) including all connected electrical items such as main switch, starter,change over switch, MCCB, voltmeter, ammeter, panel board etc, cooling tower,condenser or water pump ,valve system,controling system, condenser,refrigerant line,adjusting valve, refrigrant valve, bypass valve, daily checcking, leakage, checking noise, controlling temp. of plant,cleaning of plant and it's surrounding area etc, by one Ref Mech (Skilled) per shift for 02 shifts in a day all as per manufacturers instructions and as specified and directed by Engr-in-charge.
1st year after certified date of completion of work.
2nd year after certified date of completion of work.
3rd year after certified date of completion of work.
4th year after certified date of completion of work.
5 th year after certified date of completion of work.
5th year after certified date of completion of work.
(b) The Contractor shall Employ Refrigeration mechanic having minimum ITI qualification from Govt Recognised institute with adequate knowledge & minimum 2 years experience in maint/operation of AC plants. The operator must competent to carry out the minor maint all as directed. (TOTAL number of operators required per day are 02 nos.)
(c) Contractor shall pay the wages to the employees through e-payment i.e Adhaar linked bank accounts (credit to their bank account). Engineer-in-charge shall ensure that e-payment made to employees and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more. Monthly e-banking statement shall be furnished by the contractor to the Engr-in-charge and the same shall be kept in record duly verified.
(e) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department.
(f) Each shift duration shall be 8 hours & duty timing will be decided by Engr-in-Charge.
(g) The unit rate quoted shall deemed to be included for cost of labour for daily routine maintenance for trouble free functioning of installation.
(h) In case of any abnormal noise/ complaint the plant should be put off and same should be brought to the notice of Engr-in-charge.
(i) The operator employed by the contractor shall be capable of carrying out minor repair/ maintenance & should have well experience in AC plants as applicable.
(l) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (spanner sets, hand gloves), a penalty of Rs 3000/- will be recovered and levied
(m) The Contractor shall not employ same tradesman continuously for more than 11 months during the Contract period.
(n) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved. In case of failure, a penalty of Rs 2000/- per uniform will be levied and recovered from their dues.
(p) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly.
(q) The contractor shall provide board at proper location near each installations duly writting the name of operators and Mobile Numbers shifwise.
(r ) In case of non function of AC Plant panel recovery @ 3000 per day shall be effected 24 hrs after the defect is noticed or notified either in writing or through a social media message by GE or his rep.
(s) Any defect in to a motor , Pumps, compressure ,Control Panel ,AHU, Refrigarent Gas , Cooling Tower shall be considered as outstanding defect & Panel charge will be applicable as above in Note (r )
SPECIAL TYPE FACING
Material and labour for providing glass mosaic work plain externally all as specified, shown on drawing and directed by Engineer in Charge . Glass mosaic tiles comprising of light shade and dark shade shall be provided at the locations as directed. Colour/shade of tiles shall be as approved by GE. Make / manufacturers of Glass mosaic tiles shall be ‘M/S Koloriner or its Equivalent as approved by GE.
Material and labour for providing glass mosaic work Mural externally all as specified, shown on drawing and directed by Engineer in Charge. Notes for Item Nos 31.01 & 31.02 :- (i) The tiles shall be pasted as per the computer graphic design/CAD given by Garrison Engineers & to be fixed at locations as directed (ii) Thickness of tile shall be 4 mm to 10 mm and of size as approved. (iii) Rate qouted to be inclusive of necessary scaffolding & adhesive as required (iv) The work shall be carried out through highly skilled person having experience in relevant field and as per manufacturers instructions. (v ) Make / manufacturers of Glass mosaic tiles shall be ‘M/S Koloriner or its Equivalent as approved by GE.
SHAIJAL T M
Baka Construction
M/s M Munivenkatappa and Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid