Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.3 L+₹3.5 L (8.60%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹44.4 L+₹3.7 L (8.99%)Rejected-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹44.8 L+₹4.1 L (9.94%)Rejected-AOC | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹45.5 L+₹4.7 L (11.5%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L5 | Rejected-AOC Being not L1 |
Tender Value
₹45.8 L
EMD Value
₹91,640
Closing Date
24 Nov 2022, 6:00 pmClosed
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
PROVN OF TRG SHED AT 1 TRG BN AND SPECIAL REPAIRS TO ROOFING IN BLDG NO 226 230 AT AMMUGUDA OR MD ACCN AT 1 EME CENTRE UNDER GE NORTH SECUNDERABAD
2022_MES_559903_1
8638
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH) SECUNDERABAD
₹91,640
Yes
3 Jan 2023
26 Oct 2022
26 Nov 2022
26 Oct 2022
24 Nov 2022
10 Nov 2022
Amount
Surface dressing not exc 15 deep in hard / dense soil and removal of soil distance not exc 50mtr and depositing as required complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr in width and not exc 1.5 mtr in depth for foundations, manholes and getting out in hard dense soil complete all as specified and as directed.
Excavation in post holes or similar holes n.exc 0.50 cum and getting out/returning, filling in and ramming removing surplus soil to a distance n.exc 50 m in hard / dense soil complete all as specified and as directed.
Retuning, filling in, including spreading levelling, watering and well ramming in laying not exc 25 cm thick complete all as specified and as directed.
Supply and filling and consolidation of Moorum/red bajri from out side of MOD land & filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
Removing excavated material n.exc 50 m and deposited where directed complete all as specified and as directed.
M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation and mass concrete complete all as specified and as directed.
M&L for brick work with using old size flyash bricks, straight or curved on plan exc 6mtr mean radius, built in CM 1:6 complete all as specified and as directed.
M&L for half brick work with using old size fly ash bricks straight or curved on plan to any radius built in cm 1:4 complete all as specified and as directed.
M & L for hard core of gauge n exc 63mm using broken brick/boulders deposited spread and levelled in layer n exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 ( 40mm graded stone aggregate ) in sub base of floor complete all as specified and as directed.
M&L for Rendering 10 mm thick in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 15mm thick in two layer (10mm thick 1:6 over a coat of 5mm thick in CM 1:4) top layer mixed with WPC at 2% of cement as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound (WPC) will be measured and paid separately under relevant item of this schedule.
Supply only Integral waterproofing compound ISI marked approved quality complete all as specified and as directed.
M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper (OBD) over a coat of primer over 3mm thick wall care putty complete all as specified and as directed.
M&L for preparation of new plastered wall surfaces and applying three coat of white washing on newly plastered surfaces of walls complete all as specified and as directed.
M&L for preparation of new plastered wall surfaces and applying two coats of cement based paint over a coat of base coat on walls complete all as specified and as directed.
S&F Rolled MS plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) Fe-410-W(Gde-E-250) quality B forming holes without any attachment complete all as specified and as directed.
S&F Rolled Mild steel structure/frame made of MS box/pipe sections ERW or induction butt weld tubes conforming to IS-1161-1979 grade st 240 as in columns, purlins and truss complete fitting as directed including one shop coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and as directed.
S&F Rolled Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. FE-410 W grade complete all as specified and as directed.
S&F MS Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates grade FE 410 W (Grade E-250) complete all as specified and as directed.
S&F MS Screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square exc 5 cm and not exc 10cm long with 5 to 10 mm dia complete all as specified and as directed.
S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, AZ-150 of approved colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed.
S&F Pre painted Galvalume aluminium zinc coating GI based plain / profiled sheet as in ridge / wall cladding steel sheet 0.50mm thick, AZ-150 of approved colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed.
M&L for Preparing new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and as directed.
M&L for Providing, cement concrete 1:2:4 type B1 using 20mm graded stone agg as in roof kerbs or mud stops, rounded or chamfered on edges, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for Providing precast cement concrete 1:2:4 type B1 using 20mm graded stone agg set in cm 1:4 as in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and as directed.
M&L for Reinforced cement concrete (nominal mix) 1:2:4 type B1 using 20mm graded stone aggregates as in lintel bands / Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for Formwork to sides and soffits off floor or roof beams, lintel bands, beam haunchings, girders, bressummers, lintels, cantilevers, shelves with flat surface finished with fair and smooth surface complete all as specified and as directed.
M&L for TMT bars Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binder , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material & Labour for plain cement concrete (1:3:6) type C2 (using 40 mm graded crushed stone aggregate), 75 mm thick as in sub-base to receive floor finishes complete all as specified and as directed.
M&L for designer rubber moulded chequered cement concrete tiles with mixture of grey and white cement in equal proportions with pigments of size 300 x 300 x 22mm or 250 x 250 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed or bedding layer in CM 1:6, 15mm thick for laying floor finishes etc complete all as specified and as directed.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base of 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut kota stone as in flooring 20-25mm thick over cement screed base of 15 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut kota stone as in skirting / dado 20-25mm thick over cement plaster of 10mm thick in CM 1:4 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Supply and fix steel windows (fly proof and glazed shutter) made with galvanised steel colour coated/ powder coated ( Base steel as per IS 513 'D', galvanised as per IS 277 with zinc of 120gm/sqm) with total coating thickness of 0.60mm. ( outside for glazing and inside gauged shutter) Sections for frame should be of 72mmx55mm, section for mullion should be 72mm x 50mm section for shutter frame should be 47mmx 20mm,and section for fixing glass bead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 0.6mm. Stainless steel wire mesh of 0.45mm dia and ave width of aperture 1.4mm shall be used for fly proofing . 4mm thick plain sheet glass to be used for glazing of glazed shutters including safety grills complete all as specified and as directed. Make: NCL Alltech or equivalent as approved by GE.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete, as specified, supplied and fixed size of frame 105x60mm including filling of PCC 1:3:6 type C1 in the frame complete all as specified and as directed.
S&F 30mm thick flush door shutters solid core construction with block board core and plywood face panels, commercial type both sides complete all as specified and as directed.
S & F MS butt hinges 100 mm size medium weight cold rolled complete all as specified and as directed
S & F MS Mild steel pressed handles, oval type, stove enamelled black 150mm size complete all as specified and as directed
S & F MS barrel tower bolt 200mm long stove enameled black with bright bolt complete all as specified and as directed
S & F MS Sliding door bolts 300mm long plate type stove enameled black with bright bolt not less than 12mm dia with and including min 6 bolts and nuts four on bolt plate and two on staple plate complete all as specified and as directed
M&L for preparation and treating two coats of synthetic enamel paint over a coat of pink primer to new wood and wooden surface exceeding 10cm width or girth complete all as specified and as directed.
Dismantling of asbestos cement sheet /Plain or corrugated steel sheeting, (corrugated or semi corrugated) in roof covering complete all as specified and as directed.
Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed.
Dismantling timber Scantling framed work 40 sqcm and over in section, in any position and removing store complete all as specified and as directed.
S&F wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame work complete all as specified and directed.
S&F in repairs E grid suspended false ceiling grid system of size 600 x600mm with main runner 39x 29.7x0.60mm cross tee 29 x 24.7 x 0.60mm and wall angle 22.2 x 22.2 x 0.50mm. Ceiling suspended with 3mm dia GI wire hanger fixed with purlin/ truss and hold down clips etc complete (Main runner, cross tee, wall angle shall be MS galvanized with PPCGS) over the grid providing 4mm thick HPSC pre primered self designer texture non asbestos fibre cement building board fixed to frame with hold down clips etc complete all as specified and as directed
Demolition cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 60mm thick machine pressed precast concrete inter-locking tiles M-35 any shape, size, colour/pattern (as approved) over and including 75mm thick sand bed/cushioning, complete all as specified
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
Taking down cement plaster of any description and thickness on brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M & L for complete removal of existing treatment of wall and applying two coats of distemper oil emulsion on walls over 3mm thick wall care putty complete all as specified and directed.
M & L for preparing the old plastered or unplastered decorated surfaces of walls and applying two coats of white wash complete all as specified and as directed.
M&L for complete removal of existing treatment on walls and applying two coats of exterior weather proof paint over a coat of exterior primer including preparation of surfaces complete all as specified and as directed. Make : Apex from Asian paints or equivalent in all guard from Berger, Weather shield Max Exterior Acrylic from ICI Dulux.
Material and labour for point wiring complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded drawn through and including rigid 20mm dia PVC medium grade conduit and conduit accessories duly ISI marked on concealed etc., with new sunk type pressed steel terminal boxes suitable for switches duly painted with two coats of red oxide zinc chrome primer with suitable hylam sheet cover of suitable size for mounting of switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly complete all as specified and as directed for the following :- (a) One light point/Bell point controlled by one, one way switch 5 amps, SP
All as per item No. 60 above, but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 60 above, but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 60 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 60 here-in-before but using 2.5 square millimetre single core copper conductor cable of multistranded PVC insulated unsheathed 1100 volts grade FRLS confirming to IS-694 for 3 pin 15 amps switch socket combination point on independent board and running of 2.5 square millimetre copper conductor PVC insulated cable FRLSH as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
S & F switch piano single pole flush type 5 amps, 230 volts complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, multipurpose 3/5 pin 5 amps, flush type, 230 Volts complete all as specified and as directed.
Supply and fix switch socket combination 2 in 1, multipurpose 6 pin 15 amps, flush type, 230 Volts complete all as specified and as directed.
S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round blocks complete all as specified and as directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
S & F electronic ceiling fan regulator 5 stepped and socket type heavy duty suitable to work on 230 volts complete all as specified and as directed.
Supply and fix wall mounted LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1 x 20w, 230 volts, bipin holders, DIFFUSED TYPE connector block internally prewired etc with 2 Nos PVC round blocks for mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W complete all as specified and as directed. Make : Havells cat No-REGALBATTENT8UPTO1X22W SSBSWH incl Tube Rod cat No-PHOTONULTRA2.01213T8 SSTL20WLED865SPC, Wipro cat No WI0921208 incl Tube Rod LL13-181-65SE, Philips Cat No - TMC501P1xT-LED22WP3241 incl tube rod 20w.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with suitable dia GI bracket 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts complete all as specified and as directed. Make : Havells Cat No - ENDCITYLITPLATE+SL35WLED757 SASYBOPCWOSPD, Wipro Cat No LR13-501-XXX-57-XX, Philips Cat No - BRP030 LED35 CW MR PSU GR DX.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and as directed.
S & F MCB SPN 240 volts suitable for fixing in MCB DB of capacity 40 amps complete all as specified and directed.
S & F MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB's complete all as specified and as directed.
Material and labour for earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron funnel with watering pipe, wire mesh, complete.
Supply and fixing ceiling fans 1200mm, aluminium body, power consumption not more than 28W, BEE 5 star rated with BLDC motor, service value greater than 8.40 CMM/W, air deliver minimum 235 CMM, 350 RPM compatible with step regulator for speed control along with down rod, Canopy-2 Nos complete all as specified and directed. Make - Bajaj/Havells/Atomberg Note :- The following documents to be produced while approval :- (i) NABL test report (ii) BEE certificate (iii) BIS certificate (iv) Warranty certificate for 5 years.
Supply and Laying LT UG cable of size 2 core x 16 Sqmm in trenches /floors/on wall /service connections XLPE insulated, PVC sheathed and armoured 1100 volts grade with aluminium conductor with necessary end terminal /cable gland as per site requirement including connecting to the main switches /cut outs MCB/MCCB with necessary lugs after cutting to required length complete all as specified and as directed.
Supply and lay unrestricted pre cast concrete cable covers class LV type-2, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
Supply spread and filling approved sand in cable trenches for cushioning of LT UG cable complete all as specified and as directed.
Supply & lay GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc of size 50 mm dia bore complete all as specified and as directed.
SKY CONSTRUCTIONS
ATUL ENTERPRISES
M/S DIVIJA BUILDERS
SAI RUPA CONSTRUCTIONS
BHEEMRAO PATIL CONTRACTOR
R. Wadhumal and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .