| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.4 L+₹1.9 L (10.5%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹22.4 L+₹4.0 L (21.6%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹23.5 L+₹5.1 L (27.4%)Rejected-AOC BHANDARI NIWAS BHARAT NAGAR TEH DISTT PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹24.0 L+₹5.5 L (30.1%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
11 Mar 2024, 6:00 pmClosed
Garrison Engineer(N)Mamun
Garrison Engineer(N)Mamun Pin-145001
REPAIR/ REPLACEMENT OF ELECTRIC WIRING, MCB DBs, TPN/VTPN DBs, EARTHING AND CONNECTED ACCESSORIES, FITTINGS AND FIXTURE FOR MD ACCN OF CERTAIN BUILDINGS AT D-IV AND D-V ZONE UNDER AGE E/M-II OF GE(N) MAMUN
2024_MES_637627_2
GE(N)/M-68/2023-24
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N)Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N)Mamun
₹82,000
9 Apr 2024
28 Feb 2024
13 Mar 2024
28 Feb 2024
11 Mar 2024
6 Mar 2024
Amount
Taking down carefully unsv copper/aluminium point wiring (light/fan/Bell/socket or power) complete, including fixture and fittings such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sketch fitting etc removing materials to store for keeping in safe custody for taking credit and making good to disturb surface of wall/floor with cement mortar and finished to match existing surface complete all as specified and directed.
M & L for point wiring using 3 x 1.5 Sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable (Phase, neutral and earth wire) drawn through and incl concealed conduit medium grade of dia not less than 20mm and connected to common earth dolly with 1.6 mm thick cadmium plated CI/GI pressed steel sunken boxes and 3 mm thick plastic laminated sheet cover fixed with brass screws complete including cutting grooves for concealed wiring for light/fan/exhaust point controlled by one 1 way switch complete all as specified and directed. Note :- Conduit shall be fixed on surface/ceiling with necessary saddles where concealing of conduit is not feasible without any extra cost.
All as per Ser item No 2 but for light point controlled by two way switch .
All as per item No. 02 here in before, but for one bell/buzzer point controlled by one bell push 5 Amp
All as per Ser item No 2 abvoe but for one 5 Amp socket outlet point on same board controlled by one switch 5 Amp one way.
All as per Ser item No 2 but for one 5 Amp socket outlet points controlled by one switch 5 Amps one way on independent board.
All as per item No. 2 but but for one 15Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cafble.
M & L for point wiring using 3 x 1.5 Sqmm FRLS PVC insulated unsheathed/multi stranded copper conductor cable (Phase, neutral and earth wire) drawn through existing conduit and connected to common earth dolly with 1.6 mm thick cadmium plated CI/GI pressed steel sunken boxes and 3 mm thick plastic laminated sheet cover fixed with brass screws for concealed wiring for light/fan/exhaust fan point controlled by one 1 way switch complete all as specified and directed.
All as per item No. 08 but for One light point controlled by 2 way switch
All as per item No. 08 but for one bell/buzzer point controlled by one bell push 5 Amp
All as per Ser item No 08 but for one 5 Amp socket outlet points controlled by one switch 5 Amps one way on same board.
All as per Ser item No 08 but for one 5 Amp socket outlet point on independent board controlled by one switch 5 Amp one way.
All as per Ser item No 08 but for one 15Amp socket point with 3x2.5 Sqmm FRLS PVC insulated multi-strand copper conductor cable.
S & F switch piano flush button single pole one way 5 amp 240 volts, all as specified and as directed.
S & F Switch Socket combination 2 in 1, 5 Amp flush type, 240 V, complete all as specified and as directed
S & F Switch Socket Combination 15 Amp, 5 in 1, 3 pin, 240 volts complete all as specified and as directed
S & F socket outlet 2 in 1, 3 pin, 5 amps, flush type with shutters, 240 volts all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type, 240 volts all as specified and as directed.
S & F switch 15 Amps, flush type with shutters, 240 volts all as specified and as directed.
S & F switch piano flush button single pole two way 5 amp 240 volts, all as specified and as directed.
S&F Bell push, flush type, 5 amp AC 230 Volt etc complete all as specified and directed.
S&F Bell Ding Dong AC 230 Volt, single Pole etc complete all as specified and directed.
S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
S & F stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W flush type.
S&F fancy type Lamp holder jumbo, PVC/Polycarbonate type with back plate complete all as specified and directed.
Supply and fix LED lamp 12 watts 230 volts retfrofit suitable for any type lamp holder as required.
S&F sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing PVC concealed conduit complete all as specified and directed.
All as per item No 27 but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor.
S & F SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating not less than 100Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete all as specified and directed.
S & F Triple pole and neutral DB 4 way sheet metal enclosures double door 415 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating not less than 200Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete all as specified and directed.
S & F sheet metal enclosures double door VTPN MCB DB 4 way, 415 V AC, 50 Hz AC with 200 amps copper bus bar complete with IP54,IK09 protection suitable for wall including MCCB 100 amps, 4P, 16KA with fixed magnetic and thermal setting of same make as of DB and making connection suitable size of aluminium thimbles, making good the disturbed surface to match with existing complete all as specfied and directed.
S & F MCB TPN 40 to 100 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SP 06 to 32 amps 230 volts B curve, 50 HZ AC 10 KA complete all as specified.
M&L for repair to existing switch board by taking out the old existing ser/unsv switches, sockets, regulators any type, etc, refixing the servicable switchs/sockets/requlators etc with replacement of old unsv/broken plastic laminated sheet not less than 3mm thick of size upto 5"x5" complete all as specified and directed. Note: Old servicable retrived switches, sockets, regulators any type, etc shall be used.
All as per Ser itme No 35 above but of size 8"x5".
All as per Ser itme No 35 above but of size 9"x11".
S & F Energy efficient surface Mounted LED batten Luminire 18 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr complete all as specified and directed.
S&F surface mounted 10 Watt 2' box type LED batten as mirror light with wall mounting arrangment including connecting up with 3 core flexible copper conductor cable of suitable size in flexible conduit pipe of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
S&F Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected by 4 mm GI wire as earth lead by means of nuts and bolt,thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) in PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fair finish internal surface with 15 mm thick plaster in CM 1:4, funnel, including charcoal dust and common salt and specified including provision of 4mm dia GI wire upto 7.5 metre long protected by 15 mm bore light grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion, all as shown in electrical plate No 3 of MES SSR Part -1 (2009), all as specified and directed. Note :- RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
Taking down carefully serviceable single phase energy meters from meter box after carefully disconnecting the electrical connections and keeping aside for refixing and dismantling old burnt/unsv meter box and removing to store for keeping in safe custody for taking credit and making good to disturbed surfaces of walls , floors etc. complete all as directed.
Supply and fixing in replacement sheet moulded compound (SMC) meter box fire retardant type of size not less than 600x500x150mm to enclose 04 Nos single phase electric meters with hinged type front operated door having transparent acrylic sheet and proper locking arrangement and flush mounting in wall incl refixing the serviceable electric meters dismantled under Srl Item No 42 and making electrical connections including cleaning of disturbed area and making good the disturbed surface and matching with existing specification complete all as directed.
S&F in replacement of building security light 60W luminaire, having pressure die cast aluminium housing, PC diffuser and integrated electronic driver with high efficiency, with polycarbonate cover, IP-65 protection including 32mm bore light grade GI pipe bracket, mounted on wall or roof including all accessories viz FI clamps, fasteners, nut bolt, washer etc including connecting up with 3 core flexible copper conductor cable in flexible conduit pipe of suitable size complete all as specified and directed.
S&F in replacement of electronic type single phase meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50Hz, conforming to IS.13779, IP-54 with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. Make : HPL/INDO TECH/L&T/AMTL
Deduct : Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs. 81894.00 to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
dadwal engineers
KONARK ENTERPRISES
M/s GIrdhari Lal Rakesh Kumar
GOLDEN CONSTRUCTIONS
RD Engineers
M/S GULATI ENGINEERING WORKS
M/s. Aggarwal Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .