Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹37.1 L+₹31,020.50 (0.84%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.4 L+₹1.6 L (4.41%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.4 L+₹1.7 L (4.58%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹38.9 L+₹2.2 L (5.90%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹45.0 L
EMD Value
₹90,080
Closing Date
23 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj. Sujith Mohan, GE
Garrison Engineer 864 Enggr Wks Sec, PIN-913864,C/o 56 APO
SPECIAL REPAIR TO COOK HOUSE BLDG NO.SP-09 OF DEF and EMP COY OF HQ CORPS, PROVN OF MT STORE FOR MT PL OF RR AND PROVN OF AUSTRALLIAN WOODEN PANELING BLDG NO.P-85 (LESS BAR) IN JHELUM OFFR MESS AT BB CANTT, SRINAGAR
2023_MES_619456_1
864/WS-66/2023-24
Open Tender
Civil Works
Item Rate
180 days
B B Cantt.
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹90,080
Yes
11 Dec 2023
18 Sept 2023
28 Oct 2023
18 Sept 2023
23 Oct 2023
7 Oct 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge thickness , including nanital or similar pattern roof covering complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F in repair 2nd class soft wood plain fillets wrought, square, rectangular or triangular in section, sectiional area exc 13Sqcm but nexc 25 sqcm secured with nails complete all as specified and directed.
S&F in repair 2nd class soft wood plain fillets wrought, square, rectangular or triangular in section, sectiional area exc 6Sqcm but nexc 13sqcm secured with nails complete all as specified and directed.
S&F 6mm thick Plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed.
S&F 6mm thick veneered decorative plywood, grade-1, (with BWR resin) with decorative face face veneers on one face, fixed with nails to timber frame work complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nailscomplete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
S&F 20mm thick 2nd class soft wood boarding clean swan with butt joints and fixed with nails in eaves board complete all as specified and directed.
M&L for brickwork with old size sub class 'B' bricks straight or curved on plan exc 6m mean radius and built in CM 1:6 complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam, lintels, cantilevers, shelves incl supports etc in rough finished flat surface of concrete complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressumners, lintels over 1.5m span complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan any radius, built in cement mortar 1:4, in half brick thick wall complete all as specified and directed.
Dismantling of timber scantlings 40 sq. cm and over in section, in any position unframed work complete all as specified.
M&L for second class hard-wood in scantlings wrought fixed in frame work complete all as specified.
Fixing only any type of wood in scantling in frame work obtained from dismantling complete all as specified and directed.
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Gde-E- 250) quality-A complete all as specified and directed.
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W (Gde-E- 250) quality-A complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, (reinforcement cut as required to facilitate demolition) complete all as specified & directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200mm thick (horizontal or sloping for fair finished surfaces of concrete complete all as specified and directed.
M&L for form work to edges of concrete flats, treads, breaks in floor & roofs,concrete railings, n.exc 20 cm wide horizontal or sloping and similar works exc 5cm but n.exc 10 cm wide, fair finished surfaces of concrete complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4 type B-1 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia, as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for 22-25mm thick granite (of any type) slabe rubbed and polished, in steps, jambs, pillars, window- cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15 mm thick screed bed or bedding layer in CM 1:3 all as specified & directed.
Taking down cement plaster of any description, on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick or concrete surfaces finished even and fair complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint on walls complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all specified and directed.
M & L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all specified and directed.
Demolition of plain cement concrete(un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8), Type D-2 (using 40mm graded crushed stone aggregates) as in sub base or floors etc. complete all as specified and as directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in floor snished the surface even and smooth with using extra cement including glass dividing strips 3mm thick 38mm wide complete all as specified.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base/levelling course complete all as specified.
M&L coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 15mm thick screed bed in CM 1:6, complete all specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete fixed over and including 15 mm thick screed bed or bedding layer in CM 1:3 complete all as specified and as directed.
Dismantling, floor hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface of size 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match fixed over and including 10mm thick backing coat in CM 1:4, complete all as specified and directed.
Taking down frame with shutters (without taking off shutters from frame) n.exc 1.5 sq.m each and removing from site complete all as specified and directed.
Taking down frame with shutters (without taking off shutters from frame) exc 1.5 sqm but n.exc 4 sqm each and removing from site complete all as specified and directed.
S&F 2nd class hard-wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed.
M&L for 35mm thick 2nd class hard wood factory made Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed.
S&F 35mm thick 2nd class hardwood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) and fitted to chowkats complete all as specified and directed.
S&F 30mm thick 2nd class hardwood factory made glazed and skeleton door/window shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (b) and fitted to chowkats complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and directed.
S & F mild steel, colled rolled, medium weight butt hinges 100mm size complete all as specified and directed.
S & F 150 mm size aluminium anodised barrel tower bolts of extruded sections all as specified and directed.
S&F 150mm size extruded aluminium handles fabricated type, anodised all as specified and directed.
S&F 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded section & fixing bolts & sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S&F mild steel 300mm size, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 140mm fixed in floor complete all as specified and directed.
S&F in replacement curtain rods of 20mm dia, mild steel, chromium plated, fancy type including fixing brackets, knobs, etc. complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
S&F 15mm bore steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
S&F 20mm bore steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Lagging to pipes internal dia 15mm used in internal water supply or plumbing all round with, 25mm thick bonded mineralwool preformed ‘SNAP ON ’pipe sections of density 144Kg/cum conforming to IS-9842 with 0.01mm aluminium foil, complete all as specified and directed.
Lagging to pipes internal dia 20mm used in internal water supply or plumbing all round with, 25mm thick bonded mineralwool preformed ‘SNAP ON ’pipe sections of density 144Kg/cum conforming to IS-9842 with 0.01mm aluminium foil, complete all as specified and directed.
S&F in repairs 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F 1000 litres capacity rotational moulded polye-thylene water storage tanks three layers (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe (Minimum wt 210gm including dismantling old unserviceable PVC water tanks complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in plinth protection/hard standing, finished concrete surfaces even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2, complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil, comlete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and n. exc. 1.5m depth as in foundation in any type of soil and getting out etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4, Type B-1, using 20mm graded crushed stone aggregate as in foundation, fopoting, foundation/ plinth beams, bases for columns , basement slabs etc. complete all as specified and directed
M&L for form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work rough finished surface complete all as specified and directed.
Returning filling in including, spreading, leveling and well ramming in layers not exceeds 25 cm thick in any type of soil complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Spreading, levelling, watering and well ramming the earth filling under floor, in layers n exc. 25 cm thick complete all as specified and directed.
M&L for broken stone hard core of gauge n. exc. 63mm deposited, spread and levelled in layer n. exc. 15cm thick watered and rammed to a true surface complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with MS handles, MS peg stay with glazing bars, complete all as specified and directed
S & F stainless steel butt hinges medium weight 100 mm size etc complete all as specified and directed.
S&F 10-12mm thick 1st class soft wood Australlian wooden panelling fixed with toughened and grouted as wall panelling including fillets/cornices & 9mm thick plywood BWR fixing on walls and applying two coats of varnishing, polishing and preparation with sneezing complete all as specified and directed.
S&F Khatamband pattern false ceiling, design as approved by GE with ornamental wood work made out of 1st class soft wood (Deodar) including fillets/cornices & 12mm thick plywood and finally finishing with french polish (two or more coats) complete all as specified and directed.
Taking down carefully existing old burn out/unserviceable copper/aluminium point wiring any type (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing old materials tfrom site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for point wiring with PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 1.5 Sq.mm (Nominal area) any type any length drawn through in and including heavy duty ISI marked PVC conduit/cassing capping of suitable size along with its all connected fittings accessories including providing of pressed steel terminal sunken boxes 1.6 mm thick or PVC flush type box and dully fixed it concealed on wall or surface on wall and providing with electro plated 3mm thick plastic laminated sheet top cover of approved colours for mounting of switches sockets, regulators etc and also using /drawind of 1.5 sqmm PVC insulated FRLS wire , 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as a continuous earth wire which is connected with terminated the box to ceing rose / fitting complete and including making good to all disturbed surfaces of wall/ceiling and floor area of wiring system and to match the existing surface of wall/floor/ceiling etc. all as specified and directed for following:-
One light/fan point controlled by one way switch 5 Amp
One 3/5 pin socket outlet, 5 Amps on same board
One 3/5 pin socket outlet, 5 Amps on independent board
All as per Sl item No.84 above but using single runs of PVC insulated FRLS wire, 1100volt grade with multistranded copper conductor wire of size 2.5 Sq. mm (Nominal area) (ISI Marked) for 3/6 pin type15 Amp socket outlet point wiring system with controlled by one way switch fixed on independent board and also providing of 2.5 sqmm PVC insulated FRLS wire , 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as continuous earth wire complete all as specified and directed
S&F piano switch 5/6 Amps 230 Volts for one way switching system complete as specified and directed.
S&F socket 5/6 Amps AC 230 Volts 3/5 pin type complete all as specified and as directed.
S&F piano switch 15/16 Amps 230 Volts for one way switching system complete all as specified and as directed.
S&F socket 15/16 Amps AC 230 Volts 5/6 pin type complete all as specified and directed.
S&F fan regulator with hum free step type alongwith speed control know of capacity 120 watt 230 Volts for one way switching system complete all as specified and as directed.
S&F ceiling rose three terminals type made out of polycarbonate , isolated body complete all as specified and directed.
Supply and fixing of wall mounted slim batten type decorative integrated design LED tube light fitting of rating capacity in 1x 20W/22W with electronic driver and fitting extruded body made of aluminum housing with high quality polycarbonate diffuser with long life energy saving and required fitting use in both warm/white type colour, with providing suitable type of flat flexible two/three core copper cable and making electric connection and including taking down of old unserviceable fitting all as specified & directed. (Make Philips Cat Part No BN021LED22S 6500K/4000K PSU GR of / Havells Cat Part No LUMILINEPLUSNEOBS22WLED865SPCSSIND / Crompton Cat Part No- CCS-100-20-65- HL2-DP-NWH )
S&F ventilating exhaust fan made out of sturdy metalic body, complete with louvers and shutter operational of size 300mm sweep suitable to work on 230 Volts 50 Hz, 1200RPM, coper winding including making of suitable type /size of hole on wall compete all as specified and directed.
Supply and fixing surface mounted LED bulk head luminaries light fitting of rated capacity 10W out door type with dust and water proof, with PVC housing and unbreakable polycarbonate opal with in-built surge protection with IP 65/66 protection rating, energy efficient for ready to use and required in both warm/white type color fixture including fixing on bldg wall surface including providing of suitable type of flat flexible two/three core copper cable and making electric connection and including taking down of old unserviceable fitting complete all as specified and directed. (Make Philips Cat Part No - WT202W LED10S / Havells Cat Part No -HEXAFT10WLED857SSYMBOPC / Bajaj Cat Part No- BIBWP 10W LED
M& L for taking down carefully existing ceiling fan /exhaust fan any type sweep and removing fan blade including cleaning all dust particles and filling cavities with filler material, oiling, greasing and painting fan & blade with one coat of synthetic enamel white paint by spraying and assemble the same along with all connecting fixing accessories like rubber rell, nut, bolt, washer, lock pin etc and hanging the same in position along with all electrical wire connection complete all as specified and directed
S&F Sub main wiring system with two runs PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 2x6Sqmm and one run of 1x6 Sqmm (Nominal area) (ISI Marked) as in earth wire any type any length drawn through in heavy duty ISI marked PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall including taking down old unservicable sub main wiring system and making good all disturbed surfaces match to the existing surface complete all as specified and directed . Note:- 3 runs of 6sqmm wire and one run of PVC cassing capping/conduit shall be measured and 1.0 RM.
S&F sheet metal enclosure duly powder coated with locking arrengment system and having double door TPN 4 way distribution board with IP-43 1K-09 protection system and having mounting chanel and connection bus bar system suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase powe supply, complete with appropriate size copper bus bar and neutral and earth link etc complete alongwith providing of 01No MCCB 160 Amps rating with rupturing cap 25 KA 3 pole 415 Volts and also 12 Nos of MCB SP 63 Amps 'C' Curve of the same make as of distribution board complete & including taking down of existing DBs with MCBs and making all necessary electrical connection and dully fixed surface on wall or concealed on wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface as per existing complete all as specified and directed.
S&F sheet metal enclosure duly powder coated with locking arrengment system and having double door SPN 8 way distribution board with IP-43 protection system and having mounting chanel with having suitable rating and connection of copper bus bar system with having capacity 200 Amps and suitable size of common neutral link including taking down of existing DBs with MCBs and making all necessary electrical connection and dully fixed surface on wall or concealed on wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface as per existing complete all as specified and directed.
S&F sheet metal enclosure duly powder coated with locking arrengment system and having double door SPN 4 way distribution board with IP-43 protection system and having mounting chanel and connection bus bar system with having capacity 200 Amps and suitable size of common neutral link including taking down of existing DBs with MCBs and making all necessary electrical connection and dully fixed surface on wall or concealed on wall with the help of cutting chases to wall for fixing of DB and making good the disturbed wall surface as per existing complete all as specified and directed.
S&F MCB SPN 40 to 63 Amps, 230 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, 240 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
S&F MCB TPN 63 to 100 Amps, 230 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
Supply and laying GI pipe 40 mm bore medium grade with all fitting laid in trenches/ under road /floor/ pole/ wall for protection of cable including providing clamping arrangment for holding of pipe on pole/wall in proper size of clamps, nut bolt and washer etc complete all as specified and directed.
Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade cross sectional area of size 25 sqmm 3.5core including laid in trenches or fixing on poles or passing through pipes including taking out of old unserviceable cable any type any size complete all as specified and directed.
Excavation in trenches/ under road/ PCC path/hard standing not exceeding 1.5 m wide and not exceeding 1.5m depth for laying of pipe / cable and getting out etc complete all as specified and directed.
M&L for Sand cushioning for under ground cable provided with a layers of sand before laying cable and sand after laying and stretching the cable complete all as specified and directed.
M&L for brick covering width equal to length of brick for mechanical protection to cable with well burnt sub class 'B' bricks laid dry flat acomplete all as specified and directed.
Supply and fixing of environmental friendly LED street light fitting of rated capacity 60W out door type made out of pressure die cast hosing with glass and high performance polycarbonate optics with LEDs with drives and having IP 65/66 protection and surge to heat resistant sink for better heat dissipation and including to ready for use and required in both warm/white color type including providing suitable size of dia GI pipe light grade bracket and it to match/setting the new fitting fixture hole attachment system of suitable bracket length upto 1.2 mtr long and make to shape bend of 120 degree angle including fixing on existing pole /bldg wall/ roof with the help of 02 Nos of MS clamp with nut, bolt and including providing of suitable type of flat flexible two/three core copper cable and making electric connection and including taking down of old unserviceable fitting all as specified and directed (Make Philips Cat Part No BRP032 LED60 CW/WW SLR GR PSU / Havells Cat Part ENDURAOMNIPLUSSL60WLED757SASYTOPC / Crompton Cat Part No- LST-60-CDL-M)
M&L for earthing, complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4mm dia by means of bolts, nuts, check nuts and washers of galavanised iron and earth strip protected by provision of GI light grade pipe 20 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm/6mm flat iron with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electrical plate No 03 of SSR-2009 Part-I and connecting to earth test point complete all as specified and directed.
S&F MCB SPN 32 to 40 Amps, 230 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity complete all as specified and directed.
Supply and laying GI pipe 25 mm bore medium grade with all fitting laid in trenches/ under road /floor/ pole/ wall for protection of cable including providing clamping arrangment for holding of pipe on pole/wall in proper size of clamps, nut bolt and washer etc complete all as specified and directed.
Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade cross sectional area of size 10 sqmm 2.0core including laid in trenches or fixing on poles or passing through pipes including taking out of old unserviceable cable any type any size complete all as specified and directed.
S&F modular type switch 5/6 Amps 230 Volts, suitable for one module for one way switching system complete as specified and directed.
S&F modular type socket 5/6 Amps AC 230 Volts, suitable for 3/5 multi pin type with two module complete all as specified and as directed.
S&F modular type switch 15/16 Amps 230 Volts, suitable for one module for one way switching system complete as specified and directed.
S&F modular type socket 15/16 Amps AC 230 Volts, suitable for 5/6 multi pin type with two module complete all as specified and as directed.
S&F energy saving long life recessed/surface mounted down lighter panel LED luminaire light fitting of shape round/square type with rating wattage capacity 5 to 12 W of operating supply voltage 220AC 50Hz, decorative type with having LEDs and electronic driver and extruded body made of aluminium/PC housing with fully diffused high quality to surge protection energy efficient for ready to use and required in both warm/white type colour, fixture or all as per existing sample/type complete set duly fixed concealed in wall or on wall surface/ceiling including making suitable type/size of cutting of new hole on existing ceiling surface or in additional extra hole cutting as per site requirement for fixing of light fitting and providing suitable type flate flexible three core cable for electric connection including taking down existing unserviceable fitting complete all as specified and directed.
M&L for point wiring with PVC insulated FRLS wire, 1100 volt grade with multistranded copper conductor wire of size 1.5 Sq.mm (Nominal area) any type any length drawn through in and including heavy duty ISI marked PVC conduit/cassing capping of suitable size along with its all connected fittings accessories including providing of modular type/size of pressed steel terminal sunken boxes 1.6 mm thick or PVC flush type box and dully fixed it concealed on wall or surface on wall and providing modular type back and face top covered plate for housing / mounting of switches sockets, regulators etc and also using /drawind of 1.5 sqmm PVC insulated FRLS wire , 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as a continuous earth wire which is connected with terminated the box to ceing rose / fitting complete and including making good to all disturbed surfaces of wall/ceiling and floor area of wiring system and to match the existing surface of wall/floor/ceiling etc. all as specified and directed for following:-
One light/fan point controlled by one way switch 5 Amp
One 3/5 pin socket outlet, 5 Amps on same board
One 3/5 pin socket outlet, 5 Amps on independent board
All as per Sl item No.118 above but using single runs of PVC insulated FRLS wire, 1100volt grade with multistranded copper conductor wire of size 2.5 Sq. mm (Nominal area) (ISI Marked) for 3/6 pin type15 Amp socket outlet point wiring system with controlled by one way switch fixed on independent board and also providing of 2.5 sqmm PVC insulated FRLS wire , 1100 Volt grade (ISI Marked) with multistranded copper conductor wire used as continuous earth wire complete all as specified and directed
M/S SHIMAR STAR GLACIER
M/S BASHIR AHMAD MIR
ZAHOOR ENGINEERING WORKS
M/S NORTHERN ELECTRICAL WORKS
M/S KABIR CHOUDHARY
M/S Vivek Gupta and Co
Alishan Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .