| Sl No | Description | Qty | Unit | SWETHA ENGINEERING CONSTRUCTION L1 | PRINCE ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for decoupling the 15KW motor and dismantling the pump suction & discharge line including cost transportation charges to & from lead and lift. | 1 | No | 5,994 ₹7,072.92 | 6,500 ₹7,670 |
| 2.00 | Charges for dismantling the pump top casing and releasing all constituent parts of rotating assembly one by one. | 1 | No | 4,761 ₹5,617.98 | 5,000 ₹5,900 |
| 3.00 | Charges for removing the broken studs and all holes cleaning and rethreading in pump bottom casing. Air releasing valve and all holes cleaning and rethreading work in pump top casing. | 1 | Set | 6,135 ₹7,239.30 | 6,500 ₹7,670 |
| 4.00 | Charges for reconditioning of worn out bearing housing by metal filling and machining, bearing housing body holes and rethreading, checking dynamic balance of shaft including cost of T & P and consumables.(Work will be carried out in contractor premises) | 1 | No. | 6,200 ₹7,316 | 6,300 ₹7,434 |
| 5.00 | Charges for reconditioning of shaft by welding the wornout bearing seating area on both side of shaft welding the damaged lock nut seating threaded area, machining, bearing seating area to suit the bearing machining the threaded welding wornout portion of key way and machining the keyways as per requirement, removing the bend, checking trueness of shaft including hire charges for lathes, shaping & welding machine cost of SS welding electrode. (Work will be carried out in contractor premises) | 1 | No. | 7,800 ₹9,204 | 8,000 ₹9,440 |
| 6.00 | Charges for machining and boring 2 Nos coupling key way to suit with pump and motor shaft.(Work will be carried out in contractor premises) | 2 | No. | 2,740 ₹3,233.20 | 3,000 ₹3,540 |
| 7.00 | Charges for reassembling the pump shaft with impeller sleeve, brush, bearing housing, type flex coupling etc. | 1 | Set | 11,600 ₹13,688 | 12,000 ₹14,160 |
| 8.00 | Charges for erection of pump connecting the suction and discharges line aligning the pump & motor, coupling with motor commissioning, trill run checking. (Bearing DE & NDE side 6303-02Nos, Casing stud with nut and washer-22 Nos, suction side flange bolt and nut with washers-08 Nos, shaft sleeve-1 No, delivery side NRV 80mm-1No,Gaskets, gland rope love joy flexible coupling with spacer will be supplied by the contractor) | 1 | Operation | 24,800 ₹29,264 | 25,000 ₹29,500 |
| 9.00 | Charges for rewinding of failed 3 Phase AC 415V 15 KW induction motor including dismantling, cleaning, winding of the stator coils, applying one coat of insulating varnish, replacement of both DE and NDE bearings and assembling.(Work will be carried out in contractor premises) including cost of retrieved copper. | 1 | Set | 21,400 ₹25,252 | 22,000 ₹25,960 |
| 10.00 | Transporting charges for 3 phase AC 415 V 15KW AC induction motor and sump pump from site to contractor premises and return back. | 1 | Operation | 1,004 ₹1,184.72 | 1,500 ₹1,770 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹1,700
Closing Date
23 Dec 2025, 2:00 pmClosed
Chief Engineer/TTPS
O/o CE/TTPS
ECHP-I- Reconditioning of submerged portable split casing pump, starter panel and rewinding of failed 15KW motor at paddle feeder
2025_EB_628044_1
CE/TTPS/SE/MI/174/2025-2026
Open Tender
Miscellaneous Works
TTPS
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1,700
Yes
26 Mar 2026
2 Dec 2025
24 Dec 2025
2 Dec 2025
23 Dec 2025
2 Dec 2025
Charges for decoupling the 15KW motor and dismantling the pump suction & discharge line including cost transportation charges to & from lead and lift.
Charges for dismantling the pump top casing and releasing all constituent parts of rotating assembly one by one.
Charges for removing the broken studs and all holes cleaning and rethreading in pump bottom casing. Air releasing valve and all holes cleaning and rethreading work in pump top casing.
Charges for reconditioning of worn out bearing housing by metal filling and machining, bearing housing body holes and rethreading, checking dynamic balance of shaft including cost of T & P and consumables.(Work will be carried out in contractor premises)
Charges for reconditioning of shaft by welding the wornout bearing seating area on both side of shaft welding the damaged lock nut seating threaded area, machining, bearing seating area to suit the bearing machining the threaded welding wornout portion of key way and machining the keyways as per requirement, removing the bend, checking trueness of shaft including hire charges for lathes, shaping & welding machine cost of SS welding electrode. (Work will be carried out in contractor premises)
Charges for machining and boring 2 Nos coupling key way to suit with pump and motor shaft.(Work will be carried out in contractor premises)
Charges for reassembling the pump shaft with impeller sleeve, brush, bearing housing, type flex coupling etc.
Charges for erection of pump connecting the suction and discharges line aligning the pump & motor, coupling with motor commissioning, trill run checking. (Bearing DE & NDE side 6303-02Nos, Casing stud with nut and washer-22 Nos, suction side flange bolt and nut with washers-08 Nos, shaft sleeve-1 No, delivery side NRV 80mm-1No,Gaskets, gland rope love joy flexible coupling with spacer will be supplied by the contractor)
Charges for rewinding of failed 3 Phase AC 415V 15 KW induction motor including dismantling, cleaning, winding of the stator coils, applying one coat of insulating varnish, replacement of both DE and NDE bearings and assembling.(Work will be carried out in contractor premises) including cost of retrieved copper.
Transporting charges for 3 phase AC 415 V 15KW AC induction motor and sump pump from site to contractor premises and return back.
Complete renewal of control panel boxes electrical spares and wiring, works involves dismantling of all electrical control and wiring, fixing of all control switches and wiring, including consumables and T &P’s. (115A power contractor, over load relay 65 to 105 Amps, switch disconnector fuse unit 125 Amps & Digital AC current Transducer will be supplied by the contractor).
Less the cost of retrieved copper (this copper scraped to be retained by the contractor)
PRINCE ELECTRICALS (BID ID -1542541)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_750854.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid