| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC 93 SARASWATI PURAM COLONY SG PGI LUCKNOW UP 226 014 | LUCKNOW | LUCKNOW | UP | 226014 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.9 L+₹2.5 L (7.57%)Rejected-Finance 512 227 5TH LANE NISHANTGANJ LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹36.5 L+₹3.2 L (9.48%)Rejected-Finance H NO 145 SAINIK NAGAR RAIBAREILLY ROAD TELIBAGH LUCKNOW 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹36.9 L+₹3.5 L (10.6%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | L5₹39.4 L+₹6.0 L (18.1%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
22 Jul 2021, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PERIODICAL SERVICES AND MISC B/R WORKS FLOORING HARDSTANDING, PATH, PLINTH PROTECTIONS AND MISC B/R WORKS AT CH(CC) IN THE AREA OF AGE E/M HOSP UNDER GE E/M LUCKNOW
2021_MES_454752_1
GE/EM/LKO/HOSP/T-25 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
Lucknow
Class D or above category a (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹98,000
Yes
3 Aug 2021
25 Jun 2021
24 Jul 2021
25 Jun 2021
22 Jul 2021
9 Jul 2021
Amount
M&L for rendering 15 mm thick cement plaster in CM 1:4 with water proofing compund (@ 3% by weight of cement) on fair faces of brick work or concrete surface and finishing the surface even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge. (Note:- Water proofing compund shall be measured and paid seprately.)
Supply only integral water proofing compound conforming to IS 2645 complete all as specified and directed by Engineer-in-Charge
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge
All as per item No. 3 above but on ceiling.
M&L for PCC type B-1 (1:2:4) (20mm graded aggregate) as in benching and coving / filleting over chajjas complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly plastered surface of wall/ roof and applying two coats of exterior emulsion paint over one coat of primer complete all as specified and directed by Engineer-in-Charge
Complete removal of existing treatment for wall/ roof and applying two coats of weather proof exterior emulsion paint over a coat of primer including making good edges of chajjas and uneven surface of plaster using a thin layer of wall care putty complete all as specified and directed by Engineer-in-Charge
Preparation of old plastered or unplastered surfaces of walls by washing, rubbing down & stopping etc, and applying one coat of cement base paint of any tint/shade complete all as specified and directed by Engineer-in-Charge
All as per item No 8 above but two coats
Preparation of old plastered or unplastered surfaces of walls by washing, rubbing down & stopping etc, and applying one coat of distemper oil emulsion of any tint/shade complete all as specified and directed by Engineer-in-Charge
All as per item No.10 above but two coats
All as per item No 10 above but on ceiling.
Preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
Preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
Complete removal of existing treatment of walls and applying two coats of distemper oil emulsion over a thin layer of white wall putty on old plastered surfaces including prepration complete all as specified and directed by Engineer-in-Charge
M&L applying one coats of Apex ( Asian Paint) / Weather coat (Berger) over old painted surface including preparation of wall surface complete all as specified and directed by Engineer-in-Charge
M&L in repair for 3mm thick ACP sheet wooden finish along with frame work and making groove and shelf complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:5:10 type E2 (using 40 mm graded stone agrregate) as in fdns, filling & mass conrete etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone agrregate) as in fdns, filling & mass conrete, for hard standing etc complete all as specified and directed by Engineer-in-Charge
M&L 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as plinth protection and the like complete all as specified and directed by Engineer-in-Charge
M&L for filling joints between two panels with mix of 85/25 bitumen and sand in 1:3 complete all as specified and directed by Engineer-in-Charge
Demolition of stone slab and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in cement mortar complete all as specified and directed by Engineer-in-Charge
M&L 60 mm thick PCC intrelocking tiles (rubber laminated finish ) of size and shape as approved , laid dry on sand not less than 40 mm thick, interstices filled in floors/ pathway complete all as specified and directed by Engineer-in-Charge. (Note :- Sand cushion shall not be measured and paid separately)
M&L 60 mm thick PCC intrelocking tiles of size and shape as approved , laid dry on sand not less than 40 mm thick, interstices filled in floors/ pathway complete all as specified and directed by Engineer-in-Charge.( Sand cushion shall not be measured and paid separately).
M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping,padding and bed block, wall through and the like including weathering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed by Engineer-in-Charge
M&L Chequered cement concrete coloured tiles 20 cmx20cmx20 mm thick with coloured cement and no pigment , set, jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:4 as in floors complete all as specified and directed by Engineer-in-Charge( (Note : Screed bed will not be measured and paid separately)
M&L 18-20mm thick machine cut Kota stone slab flooring with marble stone strips/ slab/ tiles as per design approved, over and including cement screed bed 15mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing complete all as specified and directed by Engineer-in-Charge (Note : Screed bed will not be measured and paid separately)
M&L 18-20mm thick machine cut Kota stone slab as in skirting /riser over cement screed bed 10mm thick in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing complete all as specified and directed by Engineer-in-Charge (Note : Screed bed will not be measured and paid separately)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge
M&L for non skid ceramic (coloured) tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 15mm thick screed CM1:6 complete all as specified and directed by Engineer-in-Charge(Note : Screed bed will not be measured and paid separately)
M&L for non skid ceramic (coloured) tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.16 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 15mm thick screed CM1:6 complete all as specified and directed by Engineer-in-Charge (Note : Screed bed will not be measured and paid separately)
M&L Vitrified ceramic tiles (Dark Shade) 10mm thick (square/ractangular) Coloured polished tiles, area of each tile n.exc 0.38 sq m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement and pigment to match over 15 mm thick screeding CM 1:6 complete all as specified and directed by Engineer-in-Charge (Note : Screed bed will not be measured and paid separately)
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick screed in CM 1:3 complete all as specified and directed by Engineer-in-Charge (Note : Screed bed will not be measured and paid separately)
M&L coloured/designed as approved wall tiles (extrior grade) 8 to 10 mm thick area of each tile exc 0.09 sqm but n.exc 0.25 sq m in vertical/horizental surface set and jointed in neat cement slurry and pointed in white/colured cement and pigment to match over and including rendering 15 mm thick CM 1:4 complete all as specified and directed by Engineer-in-Charge. (Note :- Rendering will not be measured and paid separately)
M&L for glazed ceramic tiles in vertical surfaces 300x200 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick screed in CM 1:3 complete all as specified and directed by Engineer-in-Charge (Note : Screed bed will not be measured and paid separately)
Taking down chowkat with shutter without taking of shutter from frame n.exc 1.5 sqm each. complete all as specified and directed by Engineer-in-Charge
Taking down shutter only exc 1.0 sqm but n.exc 2.00 sqm each complete all as specified and directed by Engineer-in-Charge
Taking down shutter only n. exc 1.0 sqm each complete all as specified and directed by Engineer-in-Charge
Taking down chowkat with shutter exc 1.5 sqm but n.exc 4 Sqm each and removing from site complete all as specified and directed by Engineer-in-Charge
S&F 2nd class Hard wood in plain, solid, straight chowkats and frames wrought framed, rebated on the solid, rounded or chamfered put together with glue pinned joints complete all as specified and directed by Engineer-in-Charge
S&F Bands, straps, clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed by Engineer-in-Charge
M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate for fixing of hold fast and making good complete all as specified and directed by Engineer-in-Charge
S&F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, as per specifications& drawing complete all as specified and directed by Engineer-in-Charge
S&F factory made solid PVC moulded door shutter 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, with wood free EPS, supplying and fixing in frame at site as per specification and drawings shown in section 8 of SSR part -II complete all as specified and directed by Engineer-in-Charge
M&L 30mm thick 2nd class hard wood Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.23(b) complete all as specified and directed by Engineer-in-Charge
M&L 35mm thick 2nd class hard wood plain framed panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS:1003 (Part1),kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer-in-Charge
S&F 100mm size butt hinges medium weight (ISI Marked), rolled mild steel complete all as specified and directed by Engineer-in-Charge
S&F 75mm size butt hinges medium weight (ISI Marked), rolled mild steel complete all as specified and directed by Engineer-in-Charge
S&F 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed by Engineer-in-Charge
S&F 100mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed by Engineer-in-Charge
S&F 150mm size Aluminium anodized barrel Tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F 100mm size Aluminium anodized barrel Tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F Aluminium alloy, anodized, sliding door bolt (ISI Marked) of 300mm with hasp & staple (Bolt type) and fixing clips of sheets, coat or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge
M&L Preparation of new wooden surface exceeding 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge
S&F 2nd class hardwood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc., and removing old beads to Store complete all as specified and directed by Engineer-in-Charge
S&F aluminium alloy wire cloth, 0.45 mm nominal dia of wire and averaging width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engineer-in-Charge
S&F in repair aluminium alloy wire cloth, 0.45 mm nominal dia of wire and averaging width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass panes of any thickness, size ,quality or description from wooden frames , glazed with putty or fixed with beads in repairs complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass pan ordinary quality 3mm thick and glazing with oil putty/ wooden beads in square n. exc 0.5 m each pane complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) rubbish off the premises complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in ground floor and pavings n. exc 15 cm thick (above or below ground level) complete all as specified and directed by Engineer-in-Charge
M&L 75mm th PCC 1:3:6 type C-2 as in sub base, Paving, plinth protection, finished even and fair complete all as specified and directed by Engineer-in-Charge
M&L non-skid coloured ceremic tiles 300x300x7 mm in flooring, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick screed in CM 1:3 complete all as specified and directed by Engineer-in-Charge (Note : Screed bed will not be measured and paid separately)
M&L for 30mm thick PCC 1:2:4 type B-0 using (12.5mm graded stone aggregate ) as in sunken floor mixed water proofing compound finished surface even and smooth with using extra cement complete all as specified and directed by Engineer-in-Charge (Note : water proofing compound shall be measured and paid separately).
Rendering 15mm thick cement plaster in cement mortar 1:3 as in brick/concrete surface of sunken portion using water proofing compound complete all as specified and directed by Engineer-in-Charge (Note : water proofing compound shall be measured & paid separately)
M&Lwire brushing and cleaning top surface of cement concrete including flashings and junction of parapet etc. and surface painting with a layers of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m. blinded with grit or pea size gravel @ 0.006 cu.m. per sqm and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed by Engineer-in-Charge
M&L Cement concrete 1:5:10 type E2 using 40mm graded stone concrete as in sunken floor, foundations, filling and mass-concrete finished surface fair and even complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick walls, including racking out joints hacking for keys and scrubbing down and washing with water complete all as specified and directed by Engineer-in-Charge
All as per item no 70 above but on ceiling surfaces.
M&L rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L rendering 10mm thick on brick wall or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L rendering 10mm thick on ceiling in cement mortar 1:3 finished fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L applying three coat of white wash on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified and directed by Engineer-in-Charge
M&L applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified and directed by Engineer-in-Charge
Taking up or down steel tubing and connections of 15 mm bore complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections of 20 mm bore complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
M&L 20 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
Refixing old Steel water tubing, 15 mm bore, with new galvanized fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed by Engineer-in- Charge.
Refixing old Steel water tubing, 20 mm bore, with new galvanized fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed by Engineer-in- Charge.
S&F 20mm dia unplasticised PVC pipes of pressure tating 10 kgf/cm2 with all fittings and fixed complete to walls and ceilings or laid in floors including taking down of pipe complete all as specified and directed by Engineer-in-Charge.
S&F 15mm dia unplasticised PVC pipes of pressure tating 10 kgf/cm2 with all fittings and fixed complete to walls and ceilings or laid in floors including taking down of pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm dia bib tap cast copper alloy(fancy type), chromium plated with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repairs stop valve, cast copper alloy, fancy type,chromium plated screwed down both ends for high pressure, as per ISI suitable for 15mm dia iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass chromium plated shower rose 125mm size with swivel joints, suitable for 15mm dia GI pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china water closet (squatt pan) orrisa pattern 580x440 mm white, with front or back inlet with integral foot rests including connections to trap, and to flushing pipe, antisyphonage pipe, etc (excluding flushing cistern and flush pipe) complete including making good to floor complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC low level flushing cistern (white) 10 Ltrs capacity with internal fitting, push button operated type with and including bracket, PVC flush pipe etc complete all as specified and directed by Engineer-in-Charge.
S&F CI 'P' or 'S' trap of 100mm size complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china urinals, flat back of size 465mmX355mmX265mm, white with grating and union for discharge pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china,white, wash hand basin, flat back size 550x400mm 'including MS brackets including cutting for and pinning in, but excluding waste pipe complete all as specified and directed by Engineer-in-Charge.
S&F 32mm dia waste pipe of polythelene,flexible, for wash hand basin or urinals complete all as specified and directed by Engineer-in-Charge.
S&F waste coupling of PTMT (half or full threaded) for 32/40mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC connection 15mm size with PTMT nuts, of 450mm length complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 96 above but fixed to walls
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 98 above but with access door
S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 100 above but fixed to walls
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 103 above but with access door
M/L for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F stack clamps made out from 50x5mm size flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to walls or roof for 100mm bore of pipe etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster brick/stone wall, ceiling/facia (as in patch work) etc including racking out joint, hacking for key, scrubbing down with water complete including M&L for rendering plaster 10mm thick in cement mortar 1:3 on concrete surface of wall/ceiling/facia including one bonding coat with pedilite chemical and making good to match the adjecent surface complete all as specified and directed by Engineer-in-Charge.
Dismantling PVC water tanks exc 250 ltr but n. exc 500 ltr capacity and removing to store complete all as specified and directed by Engineer-in-Charge.
Dismantling PVC water tanks exc 500 ltr but n. exc 1000 ltr capacity and removing to store complete all as specified and directed by Engineer-in-Charge.
S&F 500 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge.
S&F 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge.
S&F 20mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC OHT tanks complete all as specified and directed by Engineer-in-Charge.
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube complete all as specified and directed by Engineer-in-Charge.
M&L Plain Cement concrete Type B-0, 1:2:4 (12.50mm graded aggregate), 25 mm thick as in floors complete all as specified and directed by Engineer-in-Charge.
M&L 18-20mm thick machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and complete and 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. (Note :- Screed bed shall not be measured and paid separately)
M&L 18-20mm thick machine cut kota stone slab as in skirting/riser over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and complete and 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. (Note :- Screed bed shall not be measured and paid separately)
Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-Charge.
Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6.0 m mean radius built in cement sand mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour complete all as specified and as directed by Engineer -in-Charge.
M&L for Providing precast cement concrete with type B0 PCC 1:2:4 (using 12.5 mm graded stone aggregate) set in CM 1:4 louvres and jallies, 35 mm thick (measured solid), including all mouldings but excluding frame complete all as specified and as directed by Engineer -in-Charge.
M&L for RCC M-25 Nominal Mix using 20 mm gradded stone aggregate in slabs supported on walls, beams and columns in floor,roof,landing etc complete all as specified and directed by Engineer-in-Charge.
M&L Formwork to soffits of suspended slabs such as roof slabs floor slabs, landing and similar work for fair finished surface complete all as specified and directed by Engineer-in-Charge.
M&L for form work to edges of concrete flats, treads, break in floors, window cills, horizental or sloping and similarexc 10cm but not exceeding 20 cm wide for fair finished surface complete all as specified and directed by Engineer-in-Charge.
S&F mild steel TMT bars 8mm dia and over ,cut to length , bent to shape requred, including cranking , bending spirally for columns hooking for columns hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L 18-20 mm thick granite stone slab ( Black colour) , bedded over screed bed and jointed in cement mortar to match the colour of slab as in flooring , polishing and grinding complete all as specified and directed by Engineer-in-Charge. (Note :- Screeding bed shall not be measured and paid separately)
S&F 140mm overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP Angle stop cock ( one way) long thread with wall flange , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for all forming branch channel (1/2) round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching complete all as specified and directed by Engineer-in-Charge.
M&L for concrete bed for 150 mm bore pipe in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for 150 mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china Europeon Water Closet (one piece) of specified make with flushing cistern & white seat cover complete all as specified and directed by Engineer-in-Charge.
S&F in repair cp angle cock (two way) complete all as specified and directed by Engineer-in-Charge.
S&F health faucet CP with 15 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F white Toilet paper holder of vitreous china (specified make) fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Pillar taps, fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP Angle stop cock ( one way) long thread with wall flange , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed by Engineer-in-Charge.
Divya Jyoti Constructions
M/s Pratap Associates
M K Engineers and Contractors
m/s raghubar dayal
M/s SNS Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .