| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Accepted-AOC Being Lowest bidder (L1) | |
| 2 | L2₹15.0 L+₹4.3 L (40.2%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
6 May 2022, 5:00 pmClosed
CWE (AF) AGRA
HQ CWE(AF) AGRA PIN-208027
REPAIR AND MAINT OF SEWAGE TREATMENT PLANT AND OTHER CONNECTED WORKS UNDER GE (AF) ADM AREA, AF STN AGRA
2022_MES_500757_3
80021-26/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) ADM AREA AGRA
As per tender documents
7 documents required · 7 mandatory
₹500
GE(AF) ADM AREA, AGRA
₹30,000
Yes
31 May 2022
1 Apr 2022
9 May 2022
1 Apr 2022
6 May 2022
22 Apr 2022
Amount
Material and labour for painting on steel and iron surfaces with one coat of synthetic enamel paint as per existing colour scheme or pattern after preperation of old painted surface of any description over 10cm in width or girth complete all as specified and directed.
Supply & pouring Compressor Oil in air blower at STPs as directed. Make : Castrol SP 320/Servo/Indane complete all as specified and directed.
Labour for dismantling, disconnecting the Air Blower including disconnecting from channel frame and electrical panel for repair of Gear Box, refitting of gear box after toping up oiling, greasing, alingment of pump set and re-fixing/ assembling testing to make it functional complete including cleaning of all dirt, dust and including transportation to civil workshop for repair work and back to working site etc. all as specified and directed. Note:- Worn out spares shall be replaced with existing make and measured and paid seprately as under:-
(a) Replacement of Pulley V Belt SPB-1800
(b) Suction air filter
(c) Bearing set
(d) Oil seal set
(e ) Piston bush
(f) Gear set
(g) Rotor Set
(h) Pulley bush
(i) Check nut
(j) Service charges
Disconnecting electric comnnections from LT control pannel and starter of Non clogging submersible pump set of any size 7.5 HP to 10 HP and removing the pipe line connections from discharge side and taking out sub pump set alongwith, column pipe from Sewage sump with the help of chainpully including transportion to wksp for repair including replacement of rusted nuts bolts. rubber gasket complete and re-assembling /refitting at work site complete all as specified and as directed. Note:- Worn out spares shall be replaced with existing make and measured and paid separately as under:-
(a) Rewinding of submersible motor.
(b) Pump Impeller
(c ) Mechanical seal set upper and lower
(d) Bearing
(e ) Fixing compounding
(f) O ring set
Labour for dismantling, disconnecting the centrifugal pump set of capacity 7.5 HP from foundation and fixing after repairing rewinding and assembling the pump set including insulating material of any size ,testing complete all as specified and directed including transportation to workshop and back after repair. Note:- Worn out spares shall be replaced with existing make and measured and paid separately as under:-
(a) Impeller CI
(b) Mechanical seal for pump shaft AISI-410
(c ) Bush sleeve (Gun metal)
(d) Connection plate
(e ) Bearing
S & F in replacement of flexible suction hose pipe heavy duty ISI marked of size 25 mm outer dia. complete all as specified and as directed.
Supply & pouring MBBR/FAB media model PP22 effective specific surface area 400 Sqm/Cum to 600 Sqm/cum of height 12mm and dia of 27mm made up of virgin media complete all as directed.Note :- MBBR media will be certified by OEM and the colour of the media must be white in colour.
M & L for strip opening of 3 phase, 415 volts, AC, 50 Hz of capacity 2 HP Induction Motor ,taking out burnt winding coil complete and rewinding with super enamelled copper winding wire as of existing size/ gauge including providing insulating material, varnishing and replacement of worn out parts like bearing , bushing, sleeves etc and re-assembling/refixing the motor as per the initial arrangement including making all connections complete all as spd and directed. Note:- Transportion to civil work shop and back to site deemed to be included in quoted rates.
M & L for strip opening of 3 phase, 415 volts, AC, 50 Hz of capacity 3 HP Induction Motor ,taking out burnt winding coil complete and rewinding with super enamelled copper winding wire as of existing size/ gauge including providing insulating material, varnishing and replacement of worn out parts like bearing , bushing, sleeves etc and reassembling/refixing the motor as per the initial arrangement including making all connections complete all as spd and directed. Note:- Transportion to civil work shop and back to site deemed tobe included in quoted rates.
M & L for strip opening of 3 phase, 415 volts, AC, 50 Hz of capacity 7.5 HP Induction Motor ,taking out burnt winding coil complete and rewinding with super enamelled copper winding wire as of existing size/ gauge including providing insulating material, varnishing and replacement of worn out parts like bearing , bushing, sleeves etc and re-assembling/refixing the motor as per the initial arrangement including making all connections complete all as spd and directed. Note:- Transportion to civil work shop and back to site deemed to be included in quoted rates.
M & L for strip opening of 3 phase, 415 volts, AC, 50 Hz of capacity 20 HP Induction Motor ,taking out burnt winding coil complete and rewinding with super enamelled copper winding wire as of existing size/ gauge including providing insulating material, varnishing and replacement of worn out parts like bearing , bushing, sleeves etc and reassembling/refixing the motor as per the initial arrangement including making all connections complete all as spd and directed. Note:- Transportion to civil work shop and back to site deemed to be included in quoted rates.
M & L for dismantling, disconnecting the screw pump set of capacity 2.25 HP from foundation after disconnectiong all connections for repairing/ greasing including replacement of worn out minor parts and re-fixing after making serviceable to the entire satisfaction complete all as specified and directed. Note:- Transportion to civil work shop and back to site deemed to be included in quoted rates.
S&F of LED bollard of 8/10 watts, 230 volts, 50 Hz with IP 65 protection with robust design and efficient light distribution complete all as specified and directed. Make:- Havells Cat Ref :- LHEYBDP6IN6K008/ Wipro or equivalent in Philips.
Supply and laying in replacement XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, of size 10 Sqmm 2 core complete all as specified and directed.
S & F in replacement of existing unsv SG Iron butterfly valve of pressure handling capacity 13-20 kg/cm2 suitable for 100 mm CI tubing complete all as spd and directed.
S&F of new dosing pump diaphragm type in replacement of the existing u/s dosing pump having discharge capacity of 6-10 lph and having pressure handling capacity of 10 kgf/cm2 complete all as specified and directed. Make :- Ramco/Declibac/Oasis
S&F in replacement of column pipe of mild steel of diameter 50 cm and having pressure handling capacity of 0-10 kgf/cm2 complete all as specified and directed.
M & L in replacement of existing unsv MCCB 100 Amps current carrying capacity 36 KA , AC 415 Volts three pole with magnetic/ thermal fixed setting complete all as specified and directed.
S&F in replacement of MCB Single pole 5 to 40 amps 240v "C" series 10KA all as specified. Make :- RAMCO/DECLIBAC/OASIS
S&F in replacement of MCB Single pole and Neutral 40 to 63 amps 240v "C" series 10KA all as specified .
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
S&F in replacement of MCB TPN / isolator 4 pole C' series 10 KA 63 Amps all. as specified and directed.
S&F in replacement of motor protection circuit breaker of 3 poles having current carrying capacity of 6-10 amps.Make-Seimens 3VU1340-1ML00 or equivalent in Legrand/ABB.
S&F in replacement of motor protection circuit breaker of 3 poles having current carrying capacity of 22-32 amps.Make-Seimens 3VU16401MP00 or equivalent in Legrand/ABB.
Supply and fixing of XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 11000 volts grade, cross sectional area 6 sqmm,4 core. Complete all as directed by Engr in Charge.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 11000 volts grade, cross sectional area 10 sqmm,4 core. Complete all as directed by Engr in Charge.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of UG cable and getting out in soft/loose of soil complete all as specified and directed.
Returning filling in and including spreading, watering and well ramming in layers not exceeding 25 cm thick in soft /loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for under ground cable upto 8 cm before laying the cable and 15 cm after laying and stretching the cable and punned down to form a bed.The punning shall be done by hand complete all as specified and directed. Note : Only punned thickness shall be measured for payment purpose.
Material and labour for sub class 'B' bricks well burnt old size laid dry flat for protection of cable complete all as specified and directed.
Supply only of poly aluminium chloride complete all as specified and directed by Engr-In-Charge.Note-Contractor must bring the test certificate for the purity of the chemicals. Make :- M/S Sree Rayalaseema Hi streghth Hypo Ltd/MS Bharti water Pvt Ltd/M/S Declibac
Supply only Sodium Hypo Chloride having 10% Chlorine content complete all as specified and directed. Notes :- (a) The contractor shall furnish the original Test Certificate of conformity of the chemicals from the manufacturer indicating MES order / CA No. and other relevant details at the time of acceptance of product by GE. (b) The chemicals shall be tested out for their genuinity within 07 days of receipt of consignment at site from NABL approved lab and report to be submitted to the Engineer-in-charge. (c) Cost of testing and transportation shall be deemed to be included in unit rate of supply. The chemicals shall be used only after their confirmation to the standards. Make :- M/S Sree Rayalaseema Hi strength Hypo Ltd/MS Bharti water Pvt Ltd/M/S Declibac
Material and Labour for earthing complete with galvanized steel earth plate Electrode 600mm x 600mm x 6mm thick buried directly in ground earth pit not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5mt below GL connected to 32 x 6mm GI strip upto 7.5 m long by mean of GI bolts ,nuts,check nuts & washers and connected to earthing test point & earth dolly all as shown in electrical plate No 3 of SSR part I 2009 & as specified and testing on completion including earth work & excavation in any type of strata , PCC (1:3:6) type chamber precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric of XPM, weight not less than 4 Kg /Sqm) with cast iron frame ,funnel with water pipe of 20mm dia GI medium grade , wire mesh and lugs etc complete all as directed.
Material and labour for cleaning of MBBR -02 Nos tank, filter feed tank, chlorine contract tank thoroughly by removing mud, grits etc from 900 KLD STP complete all as specified and as directed. Notes :- (a) Cleaning inner surface of tank completly by scraping with steel wire brush and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed. (b) Washing with clean water and bleaching powder complete tank internally and removal of left out sludge, if any at site at a distance not exceeding 50 mtr all as directed.
Material and labour for cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc at 900 KLD STP for equalisation tank complete all as specified and directed.
Supply & fixing of electromagnetic flowmeter having flanged ends with inner lining of teflon to be installed in the sewage line of 200 mm diameter pipeline including cutting of the pipeline and all necessary welding all as required at site and directed by Engr-In-Charge.Note-The cost of connection of the electromagnetic flowmeter in the existing sewage line including necessary cutting and welding are deemed to be included in the above rates.Make-Magflow/Seimens/ABB
Supply of the digital Ph meter ISI marked having range from 0 to 14 and having minimum count of 0.1 ph value with dc battery system complete all as specified and directed.
Supply of the digital TDS meter ISI marked for measurement of the total dissolved solids (tds) of the treated water and sewage water having range of 0-999 ppm complete all as specified and directed. ISI marked
Taking down the old unserviceable insulating mat & Supply & fixing of electrical insulating rubber mat of size 1m*2m*2.5 mm thickness as per IS 156252:2006 specifications all as directed.
M&L for opening of filter media chamber and taking out of unserviceable sand and filtermedia gravels and cleaning/scrapping the inside surface throughly all as directed.
S&F of pebble size of 40-25 mm grade media size in the existing dual media filter/activated carbon filter complete all as spd and directed.
S&F of pebble size of 25-12 mm grade media size in the existing dual media filter/activated carbon filter complete all as spd and directed.
S&F of coarse silex of size of 12-6 mm grade media size in the existing dual media filter/activated carbon filter complete all as spd and directed.
S&F of fine silex of size of 6-2 mm grade media size in the existing dual media filter/activated carbon filter complete all as spd and directed.
S&F of quartz silica sand of 16-32 micron grade media size in the existing dual media filter complete all as spd and directed.
S&F of activated carbon filter media (coconut shell type) IV600 in the existing activated carbon filter vessel complete all as spd and directed.
S&F of anthracite in the existing dual media filter complete all as spd and directed.
Supply & fixing in replacement of existing U/S submersible cable of 10 sqmm 4 core submersible cable in the non clog submersible pump.
S&F PVC filteration plant nozzle strainer of suitable size as per sample kept all as specified and directed.
S&F belt type oil skimmer with gear,0.5 HP Motor & belt size 8 inch wide and 10 Mtr long mounted on tank tops,unit consisting of two pulleys,fluid flow slowly over the belt leaving the floating oil on the surface of the belt (stand for fixing arrangement of unit will be considered separately on relevant items) all as specified and directed.Make:Universal Tech Pvt Ltd /Simaless/PP Aquatech
M&L for bracings,supports,clamps and back plaes fabricated from structural steel sections including nuts,bolts,washers,welding,bending,cold or hot drilling holes for boltsin any shape or size as indicated or directed inclusive of one primer coat,one undercoat and one finishing coat of paint complete all as specified and directed.
M&L for repair and maintanance of centrifuge decanter of 3 hp capacity, cleaning of centrifuge bed, changing of minor parts, bearing, belt etc to make it fully fucntional for ejection of sludge cake from it complete all as specified and directed.
Collecting and carryout samples for testing of treated water of STP, from NABL approved laboratory with following parameters and submission of detailed test report to the Engineering -in-charge.(a) Carrying out minimum essential testing of water as per IS 10500 of 1991 mandatory for chemicals colour, odour, PH valve, TSS BOD,COD.total residual chlorine, total nitrogen (NH3-N) and Bacteriological total coilform organisms per 100ml (MPN) and E coli in 100ml. Note :- Rate quoted shall deemed to be included for :- (i) Cost of sterilized bottle as reqd. (ii) Transportation charge for collection of sample.
Note :- Completion certificate will be issued only after production of performance test certificate from following OEM like :- M/S Nitasha Constructions /M/S Hydrotech Paryavaran (India) Pvt Ltd /M/S ION Exchange (India) Ltd/M/S Sombansi Engg Pvt Ltd / M/S Optimus Enviropro Pvt Ltd/ M/S Sophsicated Indl materials
M/s P.N.C. Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .