Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹35.0 L Quoted ₹37.1 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹45.0 L+₹7.9 L (21.3%)Rejected-Finance | ₹45.0 L+₹7.9 L (21.3%) | L2 | Rejected-Finance Not being L1 |
| 3 | Rejected-Technical 146 B SICOP BIRPUR INDUSTRIAL AREA BARI BRAHMANA JAMMU 181133 J K | BARI BRAHMANA | JAMMU | JAMMU AND KASHMIR | 181133 | - | - | Rejected-Technical Due to not enlisted in requisite category of work. |
| Sl No | Description | Qty | Unit | slathia construction works L1 | PROACH ASSOCIATES BUILDERS & ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of under ground cable and getting out in soft/loose soil complete all as specified and directed. | 178.88 | Cubic metre | 90 ₹16,099.2 Lowest | 120 ₹21,465.6 |
| 2.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. | 156.41 | Cubic metre | 10 ₹1,564.1 Lowest | 30 ₹4,692.3 |
| 3.00 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. | 22.47 | Cubic metre | 10 ₹224.7 Lowest | 30 ₹674.1 |
| 4.00 | S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS:14930 (Pt-2:200)/IS-16205 Pt-1:2017,IS-16205 Pt-24:2018 for protection of HT cable 120 to 185 sq.mm in under ground complete all as specified & directed by Engineer-in-charge. | 330 | Running metre | 120 ₹39,600 Lowest | 160 ₹52,800 |
| 5.00 | Taking down proper shut down from sub station, Material and labour for Preparation of old painted surfaces of 33 KV Switch yard including all steel structures/ frame/fencing/gate of bus bay at Grid, and steel housing of capacitor bank having dimension 5m x 4m x 3m (incluiding top closed), CTs/PTs inside of yard by brushing/cleaning stains, Duct cover - 30 Mtrs OLTC boxes- 01 No Mast conductor, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) with spraying machine in the yard including writing description of feeders/ equipments/ isolators in block English letters as directed with white/black synthetic enamel paint as existing including making of marking (R-Y-B) by paint, earthing strip by green paint of all over the yard complete all as complete all as specified and directed by Engr In Charge. | 1 | Each Job | 30,000 ₹30,000 | 22,000 ₹22,000 Lowest |
| 6.00 | Disconnecting power supply, Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of 33 KV 6.3 MVA transformer and its accessories with spraying machine in the yard including writing description of equipment in block English letter as ditected, with white/Black synthetic enamel paint and re-connection after painting complete all as specified and directed. | 1 | Each | 3,000 ₹3,000 Lowest | 16,000 ₹16,000 |
| 7.00 | Taking down proper shut down from sub station and Scrapping the two pole structure with Emery Paper after that Painting of 33KV HT pole 12m (set of two pole structure including the MS Channel / angle iron) with one coat of Red oxide and after that two coat of Aluminim paint. White washing of foundation and Marking on pole with Glow sign/ Paint sticker showing the Pole no and source of supply complete all as specified and directed. | 45 | Each | 300 ₹13,500 Lowest | 800 ₹36,000 |
| 8.00 | Taking down the old corroded / damaged HT Poles from the substation. Supply and fix steel tubular swaged poles (12 m) complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-64 complete all as specified & directed. Note : Necessary exacavation, foundation and coping is inclusive of rate quoted by contractor. | 8 | Each | 16,500 ₹1,32,000 | 600 ₹4,800 Lowest |
| 9.00 | Supplying and laying synthetic rubber insulating mat conforming to IS: 15652, suitable for working voltage up to 33 kV (Class ‘C’), having anti-skid surface, fire-retardant and moisture-resistant properties, of size 2.0 m × 1.0 m × 3.0 mm thick, including cutting if required and fixing in position by gluing to the surface by means of approved synthetic rubber-based adhesive in front of switchboards, panels, control boards, etc., complete all as specified and as directed by engr- in- charge. | 15 | Each | 3,000 ₹45,000 Lowest | 4,500 ₹67,500 |
| 10.00 | Inspection & visit for checking the fault occured due to rain , heavy wind and any other breakdown related to 33 KV HT line and 33 KV power house, Rectify the fault at own arrangement and report to JE /Engr in charge after rectifying the fault and proper testing and commissioning of HT line. All minor spare and parts such as nut ,bolts,disc and pin insulator,streching of conductor and all other essential accessories required for fault rectification are included in the quoted rates. Note:- Contrator of his rep shall come to the site of breakdown within one hour of notification of breakdown. In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contactor and will be deduct from his dues. | 15 | Each Job | 2,500 ₹37,500 Lowest | 3,000 ₹45,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
4 Aug 2026, 6:00 pmClosed
CWE
HQ CWE UDHAMPUR
REPAIR/ MAINT OF 33 KV KALIMATA POWER HOUSE, OVER HEAD LINES AND OTHER LOCATIONS UNDER GE (UTILITIES) UDHAMPUR
2026_MES_769823_2
CWE/U(U)-31/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Udhampur
As per NIT
7 documents required · 7 mandatory
₹500
GE (Utilities) Udhampur
₹1 L
8 Sept 2026
15 Jul 2026
6 Aug 2026
15 Jul 2026
4 Aug 2026
22 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of under ground cable and getting out in soft/loose soil complete all as specified and directed. | 178.88 | Cubic metre | 10 | ₹1,788.8 |
| - | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. | 156.41 | Cubic metre | 10 | ₹1,564.1 |
| - | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. | 22.47 | Cubic metre | 10 | ₹224.7 |
| - | S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS:14930 (Pt-2:200)/IS-16205 Pt-1:2017,IS-16205 Pt-24:2018 for protection of HT cable 120 to 185 sq.mm in under ground complete all as specified & directed by Engineer-in-charge. | 330 | Running metre | 10 | ₹3,300 |
| - | Taking down proper shut down from sub station, Material and labour for Preparation of old painted surfaces of 33 KV Switch yard including all steel structures/ frame/fencing/gate of bus bay at Grid, and steel housing of capacitor bank having dimension 5m x 4m x 3m (incluiding top closed), CTs/PTs inside of yard by brushing/cleaning stains, Duct cover - 30 Mtrs OLTC boxes- 01 No Mast conductor, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) with spraying machine in the yard including writing description of feeders/ equipments/ isolators in block English letters as directed with white/black synthetic enamel paint as existing including making of marking (R-Y-B) by paint, earthing strip by green paint of all over the yard complete all as complete all as specified and directed by Engr In Charge. | 1 | Each Job | 10 | ₹10 |
| - | Disconnecting power supply, Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of 33 KV 6.3 MVA transformer and its accessories with spraying machine in the yard including writing description of equipment in block English letter as ditected, with white/Black synthetic enamel paint and re-connection after painting complete all as specified and directed. | 1 | Each | 10 | ₹10 |
| - | Taking down proper shut down from sub station and Scrapping the two pole structure with Emery Paper after that Painting of 33KV HT pole 12m (set of two pole structure including the MS Channel / angle iron) with one coat of Red oxide and after that two coat of Aluminim paint. White washing of foundation and Marking on pole with Glow sign/ Paint sticker showing the Pole no and source of supply complete all as specified and directed. | 45 | Each | 10 | ₹450 |
| - | Taking down the old corroded / damaged HT Poles from the substation. Supply and fix steel tubular swaged poles (12 m) complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-64 complete all as specified & directed. Note : Necessary exacavation, foundation and coping is inclusive of rate quoted by contractor. | 8 | Each | 10 | ₹80 |
| - | Supplying and laying synthetic rubber insulating mat conforming to IS: 15652, suitable for working voltage up to 33 kV (Class ‘C’), having anti-skid surface, fire-retardant and moisture-resistant properties, of size 2.0 m × 1.0 m × 3.0 mm thick, including cutting if required and fixing in position by gluing to the surface by means of approved synthetic rubber-based adhesive in front of switchboards, panels, control boards, etc., complete all as specified and as directed by engr- in- charge. | 15 | Each | 10 | ₹150 |
| - | Inspection & visit for checking the fault occured due to rain , heavy wind and any other breakdown related to 33 KV HT line and 33 KV power house, Rectify the fault at own arrangement and report to JE /Engr in charge after rectifying the fault and proper testing and commissioning of HT line. All minor spare and parts such as nut ,bolts,disc and pin insulator,streching of conductor and all other essential accessories required for fault rectification are included in the quoted rates. Note:- Contrator of his rep shall come to the site of breakdown within one hour of notification of breakdown. In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contactor and will be deduct from his dues. | 15 | Each Job | 10 | ₹150 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_872095.xls
BOQ • 4.44 MB
Tenderdocuments.pdf
Tender Documents • 1.77 MB
C1.pdf
PDF • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .