| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAdmitted-Finance | ₹40.8 L | L1 | Admitted-Finance |
| 2 | L2₹46.4 LAdmitted-Finance NAMBLABAL PAMPORE DISTRICT PULWAMA JAMMU KASHMIR 192121 | PAMPORE | PULWAMA | JAMMU KASHMIR | 192121 | ₹46.4 L | L2 | Admitted-Finance |
| 3 | L3₹57.4 LAdmitted-Finance OLD AIRPORT ROAD W ANBAL SRINAGAR J K 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | ₹57.4 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Bashir Enterprises L3 | M/S falcon Builder L1 | ms new dar water star L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling of MS channel or Angle iron or flat iron sections from LT poles. | 1.5 | Qtl | 3,000 ₹4,500 | 5,000 ₹7,500 | 1,000 ₹1,500 Lowest |
| 2.00 | Dismantling of insulators of any type and any size from LT poles. | 360 | Each | 30 ₹10,800 | 35 ₹12,600 | 10 ₹3,600 Lowest |
| 3.00 | Dismantling of ACSR Conductorany size from LT poles | 4.5 | Qtl | 6,000 ₹27,000 | 2,500 ₹11,250 | 500 ₹2,250 Lowest |
| 4.00 | Dismantling & Removing carefully Old unserviceble LT cables/ Service cable of size 16 sqmm to 35 sqmm from LT Pole to MCB DB complete. | 735 | RM | 30 ₹22,050 | 20 ₹14,700 | 10 ₹7,350 Lowest |
| 5.00 | S&F in Replacement of LT Panel compartmentalised cubical Outdoor type Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 1500 Amp installed on proceline/ SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finesh over one coat of red oxide on out side surface and painted in side with two coated of red oxide primer and rear opening type with apran for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary PCC platform of suitable size. (Loc :- Near MRS)
INCOMING:-
(i) ACB drawn-out type with adjustable microprocessor release confirm to IS/IEC:60947-2, 4 pole , LT 415 Volts, 50 Hz AC grade of 1000 Amps rating 50 KA rupturing capacity with suitable for adjustable over load current and short circuit and earth fault protection - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 630/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 315 Amp Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 35 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 03 Nos, (iii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos, (iv) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 32 Amps rating 16 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos, | 1 | Each | 30,000 ₹30,000 Lowest | 3,20,000 ₹3,20,000 | 4,20,000 ₹4,20,000 |
| 6.00 | S&F of LT feeder pillar compartmentalised cubical outdoor type Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 400 Amp installed on proceline/ SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finesh over one coat of red oxide on out side surface and painted in side with two coated of red oxide primer and rear opening type with apran for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary PCC platform of suitable size.(Loc :- Near Offrs Mess)
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 315 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 315/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 63 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 03 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 40 Amps rating 16 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos. | 1 | Each | 2,20,000 ₹2,20,000 | 80,000 ₹80,000 Lowest | 1,00,000 ₹1,00,000 |
| 7.00 | Description all as per ser item No 6.00 above, but bus bar of rating 400 Amp. (Loc :- Near Shalimar )
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 315 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 315/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 200 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(iii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 63 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(iv) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 40 Amps rating 16 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos. | 1 | Each | 2,20,000 ₹2,20,000 | 80,000 ₹80,000 Lowest | 1,20,000 ₹1,20,000 |
| 8.00 | Description all as per ser item No 6.00 above, but bus bar of rating 300 Amp. (Loc :-Near Offrs Qtr No P-03 & 04)
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 160/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 32 Amps rating 16 KA rupturing capacity 'C' Curve, - 02 Nos. | 1 | Each | 1,50,000 ₹1,50,000 | 80,000 ₹80,000 Lowest | 80,000 ₹80,000 Lowest |
| 9.00 | Description all as per ser item No 6.00 above, but bus bar of rating 300 Amp. (Loc :- Near Offrs Qtr No P-05 & 06 )
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 160/5 copper wound, Class 1.0, 10 VA – 1 Set.
(iv) Indicating lamps R,Y and B Phase : 01 set of three.
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(ii) MCB 4 pole , LT 415 Volts, 50 Hz AC grade of 32 Amps rating 10 KA rupturing capacity 'C' Curve, - 02 Nos. | 1 | Each | 1,50,000 ₹1,50,000 | 80,000 ₹80,000 Lowest | 80,000 ₹80,000 Lowest |
| 10.00 | Description all as per ser item No 6.00 above, but bus bar of rating 300 Amp.(Loc :- Near Offrs Qtr No P-01 & 02)
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 160/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(ii) MCCB 04 pole , LT 415 Volts, 50 Hz AC grade of 40 Amp Amps rating 16 KA rupturing capacitiy 'C' Curve, - 02 Nos. | 1 | Each | 1,50,000 ₹1,50,000 | 80,000 ₹80,000 Lowest | 80,000 ₹80,000 Lowest |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
30 Jun 2026, 6:00 pmClosed
Lt Col Sanjay Siwach, GE
GE 970 EWS C/o 56 APO PIN-913970
SPL REPAIR/REPLACEMENT OF LOW TENSION (LT) OVERHEAD LINES WITH UNDERGROUND CABLES NEAR BUILDING NO P-1 TO P-6, P-158, P-236, P-237, P-239, P-240, P-274 TO P-282, P-286, P-299, P-333, P-334, P-344, P-345 AND P-454 AT JAK LI RC SRINAGAR UNDER GE 970EWS
2026_MES_767814_1
GE 970 EWS-51(T)/2026-27
Open Tender
Civil Works
Item Rate
180 days
JAK LI RC SRINAGAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹94,600
Yes
14 Jul 2026
26 May 2026
2 Jul 2026
26 May 2026
30 Jun 2026
13 Jun 2026
26 May 2026 - 18 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of MS channel or Angle iron or flat iron sections from LT poles. | 1.5 | Qtl | - | - |
| 2 | Dismantling of insulators of any type and any size from LT poles. | 360 | Each | - | - |
| 3 | Dismantling of ACSR Conductorany size from LT poles | 4.5 | Qtl | - | - |
| 4 | Dismantling & Removing carefully Old unserviceble LT cables/ Service cable of size 16 sqmm to 35 sqmm from LT Pole to MCB DB complete. | 735 | RM | - | - |
| 5 | S&F in Replacement of LT Panel compartmentalised cubical Outdoor type Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 600 Amp installed on proceline/ SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finesh over one coat of red oxide on out side surface and painted in side with two coated of red oxide primer and rear opening type with apran for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary PCC platform of suitable size. (Loc :- Near MRS)
INCOMING:-
(i) ACB drawn-out type with adjustable microprocessor release confirm to IS/IEC:60947-2, 4 pole , LT 415 Volts, 50 Hz AC grade of 630 Amps rating 50 KA rupturing capacity with suitable for adjustable over load current and short circuit and earth fault protection - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 630/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 200 Amp Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 03 Nos, (iii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos, (iv) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 32 Amps rating 16 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos, | 1 | Each | - | - |
| 6 | S&F of LT feeder pillar compartmentalised cubical outdoor type Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 400 Amp installed on proceline/ SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finesh over one coat of red oxide on out side surface and painted in side with two coated of red oxide primer and rear opening type with apran for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary PCC platform of suitable size.(Loc :- Near Offrs Mess)
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 200 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 200/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 63 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 03 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 40 Amps rating 16 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos. | 1 | Each | - | - |
| 7 | Description all as per ser item No 6.00 above, but bus bar of rating 400 Amp. (Loc :- Near Shalimar )
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 200 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 250/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 125 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos.
(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos.
(iii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 63 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos.
(iv) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 40 Amps rating 16 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos. | 1 | Each | - | - |
| 8 | Description all as per ser item No 6.00 above, but bus bar of rating 300 Amp. (Loc :-Near Offrs Qtr No P-03 & 04)
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 160/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(ii) MCB 4 pole , LT 415 Volts, 50 Hz AC grade of 32 Amps rating 10 KA rupturing capacity 'C' Curve, - 02 Nos. | 1 | Each | - | - |
| 9 | Description all as per ser item No 6.00 above, but bus bar of rating 300 Amp. (Loc :- Near Offrs Qtr No P-05 & 06 )
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 160/5 copper wound, Class 1.0, 10 VA – 1 Set.
(iv) Indicating lamps R,Y and B Phase : 01 set of three.
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(ii) MCB 4 pole , LT 415 Volts, 50 Hz AC grade of 32 Amps rating 10 KA rupturing capacity 'C' Curve, - 02 Nos. | 1 | Each | - | - |
| 10 | Description all as per ser item No 6.00 above, but bus bar of rating 300 Amp.(Loc :- Near Offrs Qtr No P-01 & 02)
INCOMING:-
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 160 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases - 01 No.
(ii) Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No
(iii) Digital Ammeter 96mm x 96 mm, flush pattern with 3 way selector switch - 01 No.
(iv) 3 Nos of CTs of ratio 160/5 copper wound, Class 1.0, 10 VA – 1 Set
(iv) Indicating lamps R,Y and B Phase : 01 set of three
OUTGOING
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 100 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 02 Nos.
(ii) MCB 04 pole , LT 415 Volts, 50 Hz AC grade of 40 Amp Amps rating 10 KA rupturing capacitiy 'C' Curve, - 02 Nos. | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
Tender51T_merged.pdf
Tender Documents • 2.59 MB
BOQ_859853.xls
BOQ • 17.29 MB
CorrigundamNo1.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].