Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ok |
| 2 | Accepted-Technical 368 369 2ND FLOOR BASANT BUILDING CHAUDHARY MARKET SULTANPUR SOUTH WEST DELHI DELHI 110030 | SOUTH DELHI | DELHI | 110030 | Accepted-Technical ok |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
27 Nov 2025, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Mech and Hosp Division Udhampur
Executive Engineer Mech and Hosp Division Udhampur
CAMC of 1000 LPM Oxygen Generation plant under PM Cares at Associated Hospital GMC Udhampur
2025_PWDJK_294180_1
MHDU/TS/2025-26/69
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
15 days
AH GMC UDHAMPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Executive Engineer Mech and Hosp Division Udhampur
₹17,000
XEN MHD UDHAMPUR
12 Dec 2025
4 Nov 2025
27 Nov 2025
4 Nov 2025
27 Nov 2025
5 Nov 2025
10 Nov 2025
CAMC of 02 Nos. Rotary Screw Oil Air Compressors of capacity (534 CFM, KIRLOSKAR MAKE) (534 CFM, KAISHAN MAKE) -01 each by way replacement of oil filter -01 set each, Air filter-01 set each, Oil air separator-01 set each, Inner filter-01 set each, replacement of Screw oil -60 Litres each, Chemical for oil cooler – 5 ltr, AOS gasket- 01 set each, any other allied parts of the compressors and cleaning of the machines and inspection for any wear and tear for preventing machine breakdown. CAMC includes general check-up visits for trouble free operation of OGP and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of OGP which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
CAMC of 01 No. Refrigerated Air Dryer controller of capacity 700 CFM installed at 1000 LPM oxygen generation plant under PM cares by replacement of line filters, air dryer heat exchanger cleaner – 5 ltrs, refrigerant compressor, refrigerant of suitable specification and quantity etc . CAMC includes general check-up visits for trouble free operation of OGP and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of OGP which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
Complete servicing of 250 KVA DG Set along with inbuilt AMF panel installed at 1000 LPM Oxygen Generation Plant at Associated Hospital GMC Udhampur under PM Cares by way of draining of engine oil after opening the drain plug, cleaning the chamber and tightening of plug. Replacement of lube filter-1 nos., fuel filter-2 nos., by-pass filter-1 no., and air filter both primary and safety/secondary (including O-Rings/gaskets as required). Re-Filling of the engine oil by way of providing and filling of 4 liters of Engine Oil (15W40) thereby ensuring recommended oil level with the help of dip stick/gauge. Servicing of radiator by way of draining of all the coolant mixture by removing pipe/plug, cleaning of coolant tank, outer cleaning of fins, tubes and radiator fan with low pressure hot water and detergent/caustic soda and also by way of blowing compressed air, thereafter refilling of drained coolant mixture after its filtration and topping by way of providing and filling of 05 Litres of coolant (with corrosion inhibitor properties).The job also includes checking /servicing of alternator for its smooth functioning. Fastening of all nut-bolts, clamps and checking of electrical connections, replacement of any damaged cables Lubricating/oiling of Fan pulley, Generator drive assembly and other associated parts to remove any friction and avoid rusting and unforeseen allied jobs. The Job also includes cost of material used, transportation charges, labour charges, HSD required for testing and all other kind of taxes there off and testing on no load and full load.CAMC includes general check-up visits for trouble free operation of OGP and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC includes general check-up visits for trouble free operation of OGP and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of OGP which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
Repair and maintenance of Electrical equipment’s like 250 KVA Serve Stabilizer-02 no.(JAIMA Make and FUJI Make), Main Electrical Panel Auto change over panel, Auto Sequencer Panel, allied cablings and other allied electrical equipments. Job includes the cost of spares, labour charges etc. CAMC includes general check-up visits for trouble free operation of OGP and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of OGP which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
Servicing of Oxygen concentrator (PSA Controller) Intake line filters, Valve Service kit, Exhaust filters , including topping up of Zeolite after segregation of damaged/powdered zeoilite etc. CAMC includes general check-up visits for trouble free operation of OGP and to take necessary preventive steps to eliminate/reduce breakdowns time of plant. It includes complete servicing of all the equipment’s (daily/monthly/quarterly/half yearly/9 months/ annually/preventive maintenance) whenever required. CAMC also includes repairs of any part of OGP which may develop defect, to make it functional and it is to be ensured that the efficiency of the plant remains up to the mark. If the defect in any part is non repairable or if on repairs of any part, the efficiency of the plant is under par, the defective part is to be replaced by the new one. The rates are inclusive of all charges for works involved in CAMC (01 year) and all kind of taxes as applicable.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_951687.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .