Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC SCO 122 23 UNNAMED ROAD SEC 8 CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹7.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹10.6 LRejected-Finance CHANDIGARH | ₹10.6 L | L2 | Rejected-Finance L2 |
Tender Value
₹17.0 L
EMD Value
₹34,036
Closing Date
20 Jan 2026, 12:00 pmClosed
Er. Dinesh Tandon
Executive Engineer, Electrical Division No. 2, 1st Floor Additional Deluxe Building Sector- 9/D, Chandigarh.
As per NIT
2026_CHD_89996_1
E2/25/166
Open Tender
Electrical Works
60 days
Chandigarh
As per NIT
2 documents required · 2 mandatory
₹0
₹34,036
3 Feb 2026
9 Jan 2026
20 Jan 2026
9 Jan 2026
20 Jan 2026
9 Jan 2026
DSR item No.1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group-C
DSR item No.1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group-C
DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell Push
DSR 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
DSR 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
DSR 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mm x75 mm)
4 Module (125 mm x 75 mm)
6 Module (200 mm x 75 mm)
8 Module (125 mm x 125 mm)
DSR item No. 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
DSR item No. 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DSR 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple Pole & Neutral
DSR item No.8.1 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) (Please refer DNIT for complete specification of item no.13)
DSR item No.8.7 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) (Recessed/ Surface type) (Please refer DNIT for complete specification of item no.8)
DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
200 A,36KA,FPMCCB
Supplying and fixing suitable size GI box 6 Module (200mmX75mm) in recess/surface as required with modular plate and cover, including providing and fixing 1 No. 3 pin 5/6 A & 1 No. 6 pin 15/16 A modular socket outlet and 1 No. 5/6 A & 1 No. 15/16 A modular switch. The job includes the cost of making interconnections with suitable copper wire and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. The Modular accessories should be of Lauritz Knudsen (Entice) / ABB (Ivie) / Legrand (Myrius) / Crabtree (Athena)/ Norisys (Square series) make only.
Supply & erection of Wall Fan 400mm sweep oscillating type complete with blades with regulator. The fan should be of Havells (Swing)/ Usha (MAXX AIR)/ Orient (400mm Wall44)/ Crompton (WM Hiflo wave Plus)/ Bajaj (Esteem Double String) make only. The wall fan should be provided with double string i.e. one no. controlling oscillating and one for speed. The cost including connection with adjacent light points.
Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
Size 12 inch (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only.
Supply & erection MCB 4 pole 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ curve without enclosure. The job includes the labour charges and other petty material required to complete the job. The MCB should be of Lauritz Knudsen (Exora)/ Legrand (DX3)/ Hager (h3)/ Schneider (Acti9)/ ABB (SB200M)/ Siemens (Betagard) make only.
Fabrication, supplying, installation, testing and commissioning of Indoor type cubicle type fully enclosed compartmentalized electric panel of suitable size (300mm-900mm) deep as required as site suitable for three phase 50 Hz 415 volt AC supply system made out of 1.6 mm thick CRCA sheet duly strong thread with suitable size of MS channel members and base weather proof dust and vermin proof, ventilated with louvers at sides removable gland plates at the bottom, earthing studs at both ends duly painted with powder coated finish of approved shade and two coats of anticorrosion paint including providing and fixing of four strip main and auxiliary aluminium bus bars of rating min 300 amp., multifunction meter, LT phase indicator lamp for each incomer/ outgoing, MCB distribution board metering unit and having space for accommodating various MCCB’s, MCB SP, MCB TPN, Change over switch etc as per site requirement. The manufacturer/ fabricator of LT panel should posse’s type test certificate/ reports w.r.t. construction/ manufacturing of LT panel confirming to IS: 8623/93 with breaking capacity 50KA (minimum) & Degree of protection IP42 (minimum) from CPRI /ERDA approved Lab.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 12.51 MB
BOQ_110057.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid