| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.6 L+₹2.8 L (6.07%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹48.8 L+₹3.0 L (6.65%)Rejected-Finance 0 GANGARAM DHARMKANTA TRUCK UNION JIROTA KALAN DAUSA DAUSA RAJASTHAN 303303 | DAUSA | RAJASTHAN | 303303 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹49.3 L+₹3.5 L (7.68%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹49.9 L+₹4.1 L (8.97%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L5 | Rejected-Finance Being higher bid value |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
4 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8972/E8
2021_MES_471649_1
GE/ALP (8972) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
334 days
GE ALIPORE KOLKATA
Class D and Category a (ii)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹92,000
Yes
16 Nov 2021
31 Aug 2021
5 Oct 2021
31 Aug 2021
4 Oct 2021
20 Sept 2021
60 days
Amount
Material and labour for quarterly cleaning of RCC underground sump of 100000 gallons capacity with bleaching powder by blocking the inlet / outlet flow from manholes, lifting the excess semi-solid water from the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked holes etc before normalising flow of water with and including writing letters with synthetic enameled paint " Tank cleaned on ___ date" on each cleaning just below the previous date complete all as specified and as directed. Note:-Consumption of bleaching powder for cleaning of tank shall not be less than 60 Kg and included with the quoted unit rate.
All as per item No 01 above but RCC under ground sump of 60000 gallons capacity. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 30 Kg and included with the quoted unit rate.
All as per item No 1 above but RCC under ground sump of 25000 gallons capacity. Note: Consumption of bleaching powder for cleaning of tank shall not be less than 20 Kg and included with the quoted unit rate.
Material and labour for cleaning of RCC over head tank of various following sizes with bleaching powder by blocking the inlet/outlet flow ,lifting the excess semi-solid water from the tank, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked holes etc before normalising flow of water with and including writing letters with synthetic paint " Tank cleaned on ___ date" on each cleaning just below the previous date complete all as specified and as directed:-
RCC over head tank on the roof of multistoried bldgs, of capacity 20000 ltrs. Note : consumption of bleaching powder for cleaning of tank shall not be less than 20 Kg and included with the quoted unit rate
RCC over head tank on the roof of multistoried bldgs, capacity 15000 ltrs. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 12 Kg and included with the quoted unit rate.
RCC over head tank on the roof of multistoried bldgs, capacity 10000 ltrs. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 10 Kg and included with the coated unit rate.
RCC over head tank on the roof of multistoried bldgs, capacity 5000 gallons(22500 ltrs) Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 4 Kg and included with the quoted unit rate.
Material and labour for quarterly cleaning of rotational moulded polythelene water storage tank of following sizes by scrapping the internal wall,floor with wire brush(to remove deposited scales,mud etc ) and removing sediments outside of the tank and thoroughly cleaning of tank with fresh water and then use dilute bleaching powder solution and fresh water complete including writing letters with synthetic paint " Tank cleaned on ___ date" on each cleaning just below the previous date complete all as specified and as directed:-
PVC tank of 2000 ltrs capacity. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 1.5 Kg and included with the quoted unit rate.
PVC tank of 1500 ltrs capacity. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 1.2 Kgand included with the quoted unit rate.
PVC tank of 1000 ltrs capacity and -ditto-Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 1 Kg and included with the quoted unit rate.
PVC tank of 750 ltrs capacity. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 0.75 Kg and included with the quoted unit rate.
PVC tank of 500 ltrs capacity. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 0.50 Kg and included with the quoted unit rate.
PVC tank of 250 ltrs capacity. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 0.30 Kg and included with the quoted unit rate.
Material and labour for quarterly cleaning of RCC tower mounted tank of 50000 gallons capacity with bleaching powder by blocking the inlet / outlet flow from manhole ,lifting the excess semi-solid water from the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked holes etc before normalising flow of water with and including writing letters with synthetic enemeled paint " Tank cleaned on ___ date" on each cleaning just below the previous date complete all as specified and as directed. Note;-Consumption of bleaching powder for cleaning of tank shall not be less than 30 Kg and included with the quoted unit rate.
All as per item No 6 above but RCC tower mounted tank of 25000 gallons capacity. Note:- Consumption of bleaching powder for cleaning of tank shall not be less than 20 Kg and included with the quoted unit rate .
Material and labour for construction of masonary valve pit chamber of size 1000x1000x900mm internally with burnt brick (Sub class "B") full brick thick brick work in cement mortor (1:6), 10 mm thick plastering in Cement mortar (1:4) internally and externally upto 150mm below the ground level, 150mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregated) as in foundation bed with 150mm all round ofset from outer side of brick work, 3 mm thick MS sheet cover with locking arrangement hinged with 50 x 50 x 6 mm angle iron frame embeded in PCC (1:3:6) type C-1 (using 20mm graded stone aggregated) as coping etc including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on steel surfaces including necessary earth work in soft/loose soil complete all as specified and as directed.
Collecting the sample of water of required quantity in bottle/kit from different point produced duly levelled the source through Engineer-in-charge for forwarding to the test house and testing of water for iron, PH value, Hardness, trubidity, chloride, fluoride ,aresenic test and producing the test report in triplicate to be carried outg from NABL & ISO 17025 accredited laboratory/National test House/Govt approved laboratory complete all as specified and as directed . Note : Testing shall be carried out quarterly.
Collecting the sample of water of required quantity in bottle/kit from different point produced duly levelled the source through Engineer-in-charge for forwarding to the test house and carrying out bacteriological test for water sample quarterly and producing the test report in triplicate to be carried out from NABL & ISO 17025 accredited laboratory/National test House/Govt approved laboratory complete all as specified and as directed Note: Sample of water shall be collected and tested quarterly.
Material & labour for 15mm thick rendering with cement mortar (1:6) on brick or concrete surfaces, finished the surface even and smooth without using extra cement for water tank complete all as specified and as directed
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying CI/GI pipes and getting out in soft/loose soil complete all as specified and as directed
Removing excavation soil at a distance not exc 50 m and deposited where directed complete all as specified and as directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed
Taking up or down steel tubing & connection and removal from site as directed for following bore of pipes complete all as specified and directed :-
GI Pipe 50mm bore
GI Pipe 40mm bore
GI Pipe 25mm bore
GI Pipe 20mm bore
Supply and laying galvanised iron tubing of medium grade with ISI Marked with all fittings ( such as bends, elbows, tees, short pieces of medium grade , connectors, back-nuts, caps, plugs and unions etc.) laying in trenches/ floors/ ducts and also cutting pipes, screwing, and for making forged bends on piping as required for the following bore of pipes complete all as specified and directed :-
GI Pipe 50mm bore
GI Pipe 40mm bore
GI Pipe 25mm bore
GI Pipe 20mm bore
Supply and fixing for Gun metal gate valve conforming to IS -778 with iron wheel head,screwed both ends on GI pipes with GI union including taking doiwn old one for the following bore.complete all as specified and directed :-
Gun metal valve 50mm bore
Gun metal valve 40mm bore
Gun metal valve 25mm bore
Gun metal valve 20mm bore
Material and labour for one coat of cement base paint on external surface and one coat of non toxic food grade epoxy paint on inner surface of RCC tank including preparation of old surfaces complete all as specified and as directed.
Supply & fixing for 150mm MS pipe, heavy duty (Class 'C') of thickness 5.4mm conforming to (IS 1239) (Part 'A' 2004) including painting with two coats of black butumnus paint (suitable for drinking water) over a coat of good quality metal primer including taking down old pipe complete all as specified and as directed. Note: The rates shall include the cost of consumables for cutting and welding.
All as per item No 19 above but 100mm bore of pipe.
.All as per item No 19 above but 80mm bore of pipe.
Detection of leakage in water main by required excavation in water logged/foul condition including bailing out leakage water by bucket etc for repair of leakage GI pipe of size 50 mm bore including cutting, threading for addition & alternating for all as required as per the site including cost of labour charges and re-fixing of necessary fittings such as socket ,bend,elbow,etc in existing location complete all as specified and as directed.
Detection of leakage in water main by required excavation in water logged/foul condition including bailing out leakage water by bucket etc for repair of leakage GI pipe of size 80 mm bore including cutting, threading for addition & alternating for all as required as per the site including cost of labour charges and re-fixing of necessary fittings such as socket ,bend,elbow,etc in existing location complete all as specified and as directed.
Detection of leakage in water main by required excavation in water logged/ foul condition without hampering water supply including bailing out leakage water by bucket etc for repair of leakage in CI pipe of 150 mm size by burning out lead joints wherever required including cocking material and extra pig lead and all other accessories required and including fixing of fittings all as required complete all as specified and as directed.
Detection of leakage in water main by required excavation in water logged/foul condition without hampering water supply including bailing out leakage water by bucket etc for repair of leakage in CI pipe of 100 mm size by burning out lead joints wherever required including cocking material and extra pig lead and all other accessories required and including fixing of fittings all as required complete all as specified and as directed.
Detection of leakage in water main by required excavation in water logged/foul condition without hampering water supply including bailing out leakage water by bucket etc for repair of leakage in CI pipe of 80 mm size by burning out lead joints wherever required including cocking material and extra pig lead and all other accessories required and including fixing of fittings all as required complete all as specified and as directed.
Supply and fixing for 150m dia PVC Foot Valve heavy duty, Ball type with PVC flange ends conforming to IS 4038 h any type including all accessories after and including taking up of old unserviceable foot valve complete all as specified and as directed.
All as per item No 27 above but 100mm dia.
All as per item No 27 above but 80mm dia.
Supply and fixing for 150mm bore CI check swing type reflux valve (Conforming to IS-5312 (Part-I) heavy duty, flanged type, PN 10 including all accessories including taking up of old unserviceable valve complete all as specified and as directed by the Engr-in-Charge.
All as per item No 30 above but 100mm dia.
All as per item No 30 above but 80mm dia.
Supply and fixing for 150mm dia cast iron butter fly valve IS-13095-1991 double flanged and wafer type (PSI-250) including all accessories including taking up/down of old unserviceable valve complete all as specified and as directed.
All as per item No 33 above but 100mm dia.
All as per item No 33 above but 80mm dia.
All as per item No 33 above but 50mm dia
Material and labour for cast iron sluice valve conforming to IS -14846 with flanged ends of class PN 1.6 ISI marked, drilled for bolts comprising of Brass spindle cast iron operating wheel, including necessary rubber gasket joint complete with nuts bolts and washer for the size of 150 mm dia bore complete all as specified and as directed.
All as per item No 37 above but 100mm dia bore size
All as per item No 37 above but 80mm dia bore size
Supply, hoisting and fixing in proper position ISI embosed three layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 2000 litres including providing necessary connections after disconnecting and taking down of existing tanks complete all as specified and as directed.
All as per item No 40 above but 1500 ltrs capacity
All as per item No 40 above but 1000 ltrs capacity.
All as per item No 40 above but 750 ltrs capacity.
All as per item No 40 above but 500 ltrs capacity.
Material and labour for painting of 10-30 HP capacity centrifugal pump set after removing old painted/ rusted surafce by paint removers such as blow lamps, scrapers etc over the surface of motor/pump body and giving one coat of red oxide primer and after which painting with two coat of black anticorrosive synthetic enamel paint on the surface of centrifugal pump set with electrical spray machine and letter writing by using white paint on painted surface by showing MES No & Capacity on ordered location etc complete all as specified and as directed.
Supply and fixing Mild steel angle iron grade Fe 310-0 as in framing of valve pit cover including hinge and locking arrangement complete all as specified and directed.
Supply and fixing 3mm thick mild steel plate conforming to Fe 310-0 as in covering of valve pit chember complete all as specified and directed.
Material and labour for painting of steel plate & mild steel angle any size over 10cm width or girth with two coats of superior quality synthetic enamel paint over a coat of red oxide primer after cleaning of existing surface complete all as specified and directed.
Supply and lay 3-layer PP-R (P o l y p r o p y l e n e random copolymer) of 63 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded poly propylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as directed.
All as per item No 49 above but for outer dia 90mm complete all as specified and directed. .
Supply and fix PP-R Gate valves (brass insert) of 63 mm outer dia Complete with fittings by providing and fixing suitable PPR fittings including cutting and making fusion joint etc.complete all as directed
Supply and laying of Ductile iron pipe centrifugally cast-IS-8329-2000) of 150mm dia class K9, flanged end with and including rubber gasket joint complete with nuts and bolts but excluding DI specials complete in any length laid in trenches or in ground including taking down of old pipes complete all as specified and directed.
All same as item No 52 here in before but 100mm diameter complete all as specified and directed.
M & L for fabrication of aluminium bulletin board made out of double door shutter of size 884 mm X 593 mm using 40 mm X 18 mm aluminium section, main frame of size 1222 mm X 921 mm made of aluminium section 40 mm X 18 mm duly strengthened by another aluminium section of size 20 mm X 20 mm complete duly fixed with sunmica of size 1220 mm X 920 mm X 3 mm (thick) at back and 4 mm thick plain glass housed in front shutter panles using high class PVC gasket complete including two steel handles with magnetic locks at shutter to facilitate smooth opening.
Taking out unserviceable ladder of Aluminium/Angle iron and supply and fix of ladder fabricated with angle iron frame 50 mm x 50 mm x 6 mm, 45 cm wide & providing angle iron steps of size 40mm x 40mm x 6mm thick angle iron at the intervals of 30 cms including cutting, welding bending to shape of any length including two coats of synthetic enamel paint over a coat red oxide primer all as directed by Engr-in-Charge.
S & F of Continuous Water Level Indicator and Control function in overhead water tanks, capacitance type,10 to 4500 pF, 0 to 100 % indication, +/- 2% accuracy 110/115/230/240 V AC Supply, 50 Hz, including signal cables and all necessary fittings complete all as specified.
Material & Labour for removal of bushes, shrubs etc. vegetation growth in and around pump house complex by using axe, talwar, spade, showel, grass cutting machine, etc as per site requirement complete all as specified & directed by Engineer-In-Charge.
M & L for Fire Stand made of angle iron with suitable size top cover made of MS sheet of thickness 3.15 mm including six Nos hook to accomodate fire buckets including necesary civil work for foundation, duly painted by one coat of red oxide and two coats of signal red colour paint complete all as specified and directed.
Supply and fixing Ball brass valves size 50mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified
Dimantling and taking up of old fittings and Supply and fixing DI specials class K-12 both end flanged or both end spigot/socket or one end flanged and other end spigot/socket any type such as bends, tapers, reducers, duck foot bend, tee pieces (single and double branch), etc including cutting of pipes for upto 150 mm dia ductile iron pipe as per site requirement complete all as specified and as directed by the Engr-in-Charge.
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc.complete all as specified and as directed by the Engr-in-Charge.
Chipping of unsound /weak concrete materials from slabs , lintel,chajja, fin, facia etc. by any means as directed by engr-in-charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etc and disposal of all debris out of MOD land and complete all as specified and as directed by Engr-in-Charge for 25mm average thickness (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender)
M & L Removing of concrete all around reinforcement excluding from behind the bar by manual methods (using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface complete all as specified and directed by Engr-in-charge ( Make : SIKA/FOSROC) upto 12 mm dia bar (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender)
All as per Item No 63 above but for above 12mm dia barscomplete all as specified and as directed by Engr-in-Charge (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender)
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. upto 12 mm dia bar (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender).
All as per Item above but for above 12mm dia barscomplete all as specified and as directed by Engr-in-Charge (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender)
Supply and application of Epoxy Zinc rich primer on the prepared steel surface excluding behind the bar by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed by Engr-in-charge. Make ; SIKA/FOSROC (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender) .
Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible . The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as spd and directed by the Engr-in-charge upto 25 mm average thickness . Make :- Sika/Fosroc (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender)
M & L for applying curing compound over concrete surfaces as per manufactures instruction upto eight storie bldgcomplete all as spd and dir by Engr-in-charge .Make :- Sika/Fosroc (upto any hight of bldg including necessary double layer self supporting steel scaffolding. site condition may be ascertained before quoting of tender)
M&L for Rendering 15mm thick in Cement mortar (1:4) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth with using WPC complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick cement plaster with cement mortar (1:6) on fair faces of brick work or concrete surfaces complete neruu finish all as specified and directed.
M&L for Rendering 5mm thick with cement mortar (1:3) on concrete surfaces and finished the surface even and smooth as in ceiling complete neruu finish all as specified and as directed by Engineer-in-charge.
M&L for preparation on new plastered surfaces of wall and applying 2 coats of cement base paint over a coat of primer all as specified and directed
M&L for preparation on old plastered surfaces of wall and applying one coat of cement base paint complete all as specified and directed
RADHA ENTERPRISE
Shanti Construction Company
SEN ELECTRIC WORKS
NUPUR CONSTRUCTION
NESAIL CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .