Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹27.2 L+₹1.5 L (5.64%)Rejected-Finance AMBAGAN TEZPUR TOWN PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹33.1 L+₹7.3 L (28.3%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L3 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL RAJNEESH GUPTA, CWE TENGA
HQ CWE TENGA, PIN 900194 C/O 99 APO
REPAIR/REPLACEMENT OF HT LINE, MARSHELLING YARD MRS, DEFFERENT 11 KV SUB STATION INCLUDING REPAIR OF TRANSFORMER AND CONNECTED WORKS AT MISSAMARI UNDER GE MISAMARI
2020_MES_396269_1
8212/E8
Open Tender
Civil Works
Item Rate
365 days
MISSAMARI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MISSAMARI
₹80,000
Yes
17 Feb 2021
19 Nov 2020
21 Dec 2020
19 Nov 2020
18 Dec 2020
3 Dec 2020
75 days
Amount
Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre wide and exc. 1.50 Metre but not exc. 3.00 Metre in depth, for Foundation of Poles/ Stays, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
Dismantling unserviceable Steel Tubular Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Poles will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
Dismantling Stay Assembly of any description and any size including Mild Steel Clamps with Bolts, Nuts and Washers etc., complete all as specified and as directed. NOTE: Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed.
Dismantling Insulators like Pin type, Shackle type from existing Electric Poles of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed.
Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc., complete all as specified and as directed.
Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segreating serviceable Bricks/Precast covers, Pipes, Cables etc, and keep in safe custody for reuse, complete all as specified and as directed. NOTE : Earthwork will be measured and paid under appropriate Items.
M&L Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Formwork (as/if required), complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required) complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed.
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-55 (11.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally from Top of Coping) including writing MES Pole No.with synthetic Enamel Paint (First Grade/quality), complete all as specified and as directed. NOTE : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
M&L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20mm, including 7/4.00 mm Galvanised Stay Strand, complete all as specified and as directed. NOTE: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, etc., Loop Insulator, etc. will be measured and paid under approprite Items.
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
Refixing only Cross-arms, Bracings, Supports, Clamps and Back Plates (serviceable materials i.e. Structural Steel Sections obtained from Item No. 7 here-in-before) including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 150mm Height, 150mm dia for 11 KV grade, complete all as specified and as directed
Fixing only Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 150mm Height, 150mm dia for 11 KV grade, (Serviceable Insulator obtained from Item No. 8 here-in-before) complete all as specified and as directed
S&F Disc type insulator porcelain, vitreous,145mm high and 255mm dia ball and socket Type white , brown or green insulator single Disc Assembly for tension with Tension Clamps for conductors working pressure 11000 Volts, complete all as specified and as directed.
Fixing only Disc type insulator porcelain, vitreous,145mm high and 255mm dia ball and socket Type white , brown or green insulator single Disc assembly for tension with tension Clamps for conductors working pressure 11000 Volts (Serviceable Insulator obtained from Item No. 8 here-in-before), complete all as specified and as directed.
S&F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x140mm, clearance of hole 25.50 mm dia, complete all as specified and as directed.
S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
Restringing ACSR Conductor of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wire complete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
S&F Cradles, hexagonal/rectangular fabricated with Galvanised Steel Wire with 4.00mm dia including binding with Aluminium Binding Wire, complete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
M&L Danger Notice Plate of 1.6 mm thick Mild Steel Sheet, vitreous enamelled white, with Letters, Figures and Conventional Skull and Bones in Signal Red colour and fixed with MS Clamps Bolt and Nuts of approved size, for HT 25x20 Cm size including dismantling unserviceable one, complete all as specified and as directed .
S&F Expulsion Fuse, Single Pole, Channel type/drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps including taking down unservice-able Fuses, complete all as specified and as directed.
Supply and Fixing expulsion fuse single pole, double stack channel type suitable,for working pressure 33000 Volts grade including dismantling of old unserviceable fuses complete all as specified and directed.
S&F Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable,for working pressure 11000 Volts including dismantling of old unserviceable and connection to earth Strip, complete all as specified and directed.
S&F Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable,for working pressure 33KV including dismantling of old unserviceable and connection to earth with Strip, complete all as specified and directed.
S&F Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted on insulator and fitted on steel frame , current rating 200 Amps, mechanically operated mechanism from Ground Level consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including dismanting old unserviceable Switch Air Break of any descrip tion, complete all as specified and as directed
Dismantling Air Break Gang Operated Switches HT 11 KV 3 Phase, any capacity ( 200/400 ) Amps vertical / horizontal mounted including Insulators and Operating Mechanism for repair/replacement of broken / worn out components and insulators etc. with or without taking down from Pole all as directed. NOTE :- (a) Parts needed to be replaced shall be measured and paid seperately as 'supply only' against appropriate Items of Schedule. However Labour component involved in replacement is included in Unit Rate quoated against this Item. The Unit Rate shall deemed to be included for handling of serviceable materials for reuse to site and as directed (b) Any minor repairs involved to make the GOD functional even if notified by Engineer-in-Charge shall be carried out by the Contractor without any extra cost to the Department.
Supply only Male Contact/ Moving Contact Blade suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed.
Supply only Female Contact/ Fix Contact Jaw suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed.
Supply only Tinned Copper Flexible Jumper 200/400 Amps, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed.
Supply only MS Jumper Carrier, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed
Supply only Back Connector Plate, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and as directed
Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 120 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
M&L Cable End Jointing Kit Indoor Termination Cold Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 70 Sqmm to 95 Sqmm complete all as specified and as directed
M&L Cable Jointing Kit Straight Through Termination Cold Shrink-able type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 70 Sqmm to 95 Sqmm complete all as specified and as directed.
M&L Cable Jointing Kit Straight Through Termination Cold Shrink-able type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size120 Sqmm to 185 Sqmm complete all as specified and as directed.
M&L Cable End Jointing Kit Indoor Termination Cold Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 120 Sqmm to 150 Sqmm complete all as specified and as directed
M&L Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 70 Sqmm to 95 Sqmm complete all as specified and as directed
M&L Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 120 Sqmm to 150 Sqmm , complete all as specified and as directed
S&F Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded aggregate) Type B-1 of size (0.5M X 0.05MX1.0M) Cable Route Indicator including embossing 'DANGER/11KV CABLE/MES' on both sides and painted Letters with approved Colour, burried in ground for a depth of 45 Cm including necessary Earth Work, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
S&F Unreinforced Pre-cast Concrete Cable Cover, Class HV type 2 flat of size 450x180x40mm with minimum average breaking load 350 Kg, as per IS-5820:1970, complete all as specified and as directed.
Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
S&F Galvanised Iron Pipe 80mm bore (dia), Light grade as in protection of UG Cable laid in Trenches, complete all as specified and as directed.
Taking out Transformer from its Position from any location under GE Missamari for repair /servicing/ rewinding of capacity 75 to 250 KVA , 11/0.433 Volts disconnecting /opening HV, LV Electrical connections, earthing connections along with following other works. (a) Transporation of transformer to workshop at Tezpur/ Guwhati and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed. (b) Opening of transformer top cover by extraction ,removing of serviceable - unserviceable nuts bolts and washers etc (c). Lifting primary coil (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully , and display all the parts without damaging any portion (g) Refilling topping up of transformer oil after dehyderation and filteration in transformer. (d). Reassembeling the transformer complete with all existing serviceable parts, and new parts as ordered . (e) Reinstall the Transformer at site in position as directed after repair connecting HV, LV electrical connections, earthing connections and testing to entire satisfaction on load . Note- (f) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer, rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehyderation and filteration of transformer oil etc shall be measured and paid seperately under appropriate Item of schedule. (g) Renewal of adequate size Nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOATED
Taking out Transformer from its Position from any location under GE Missamari for repair /servicing/ rewinding of capacity 300 to 500 KVA , 11/0.433 Volts disconnecting /opening HV, LV Electrical connections, earthing connections along with following other works. (a) Transporation of transformer to workshop at Tezpur/ Guwhati and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed. (b) Opening of transformer top cover by extraction ,removing of serviceable - unserviceable nuts bolts and washers etc (c). Lifting primary coil (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully , and display all the parts without damaging any portion (g) Refilling topping up of transformer oil after dehyderation and filteration in transformer. (d). Reassembeling the transformer complete with all existing serviceable parts, and new parts as ordered . (e) Reinstall the Transformer at site in position as directed after repair connecting HV, LV electrical connections, earthing connections and testing to entire satisfaction on load . Note- (f) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer, rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehyderation and filteration of transformer oil etc shall be measured and paid seperately under appropriate Item of schedule. (g) Renewal of adequate size Nut, bolts & washers of transformer top cover shall deemed to be included in UNIT RATE QUOATED
Taking out potental transformer from its Position from main receiving station under GE Missamari for repair /servicing/ rewinding of 33 KV disconnecting /opening HV, LV Electrical connections, earthing connections along with following other works. (a) Transporation of transformer to workshop at Tezpur/ Guwhati and back to site by making necessary arrangements of T&P (crane, recovery, vehicle, tripoid to be arranged by firm ) as directed. (b) Opening of PT top cover by extraction ,removing of serviceable - unserviceable nuts bolts and washers etc (c). Lifting primary coil (HT) and secondary coil (LT) , dismantaling of PT complete part by part carefully , and display all the parts without damaging any portion (g) Refilling topping up of oil after dehyderation and filteration in transformer. (d). Reassembeling the PT complete with all existing serviceable parts, and new parts as ordered . (e) Reinstall the PT at site in position as directed after repair connecting HV, LV electrical connections, earthing connections and testing to entire satisfaction on load . Note- (f) Replacement of userviceable parts like; , rewinding , reinsulation of Primary and secondary coil with copper winding wire, dehyderation and filteration of oil etc shall be measured and paid seperately under appropriate Item of schedule. (g) Renewal of adequate size Nut, bolts & washers of PT top cover shall deemed to be included in UNIT RATE QUOATED
M&L for rewinding HT coil of 11/ 0433 KV Transformer any capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
Re-insulation of HT coil of transformer of any capacity using proper size paper insulation material to form DPC Copper wire and HT insulation material suitable for HT 11 KV transformer complete all as specified and directed. (Note : Item shall be measured only where re-insulation of copper wire is required.)
M&L for rewinding LT coil of 11/ 0433 KV Transformer any capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
Re-insulation of LT coil of transformer of any capacity using proper size paper insulation material to form DPC Copper wire and insulation material suitable for HT 11 KV transformer complete all as specified and directed. [Note : Item shall be measured only where re-insulation of copper wire is required].
Servicing to transformer at site of capacity 50 KVA to 250 KVA installed on Plinth / Pole mounted structure by opening top cover & replacing unserviceable spares / components of transformer ,without lifting core assembely reassembling after repair & testing complete all as specified and directed by Engr-in-Charge. Note- (f) Replacement of userviceable parts like; Bush insulator, brass studs, cork gasket, breather assembly, tap changer,etc shall be measured and paid seperately under appropriate Item of schedule.
Supply only Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity 350 to 500 KVA, 11/0.433 Volts transformers
Supply only Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply only Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity50 to 150 KVA, 11/0.433 Volts transformers
Supply only brass stud on LT side as per existing size, shape and specification for capacity 350 to 500 KVA, 11/0.433 Volts transformers
Supply only brass stud on LT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply only brass stud on LT side as per existing size, shape and specification for capacity 50 to 150 KVA , 11/0.433 Volts transformers
Supply only cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 350 to 500 KVA, 11/0.433 Volts transformers
Supply only cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply only cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Volts transformers
Supply only Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity 350 to 500 KVA, 11/0.433 Volts transformers
Supply only Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply only Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity50 to 150 KVA, 11/0.433 Volts transformers
Supply only brass stud on HT side as per existing size, shape and specification for capacity 350 to 500 KVA, 11/0.433 Volts transformers
Supply only brass stud on HT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply only brass stud on HT side as per existing size, shape and specification for capacity 50 to 150 KVA , 11/0.433 Volts transformers
Supply only top cover gasket set as per existing size, shape and specification complete for capacity 350 to 500 KVA , 11/0.433 Volts transformers
Supply only top cover gasket set as per existing size, shape and specification complete for capacity 200 to 315 KVA, 11/0.433 Volts transformers
Supply only top cover gasket set as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Volts transformers
Supply only breather assembly as per existing size, shape and specification complete for capacity 350 to 500 KVA , 11/0.433 Volts transformers
Supply only breather assembly as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply only breather assembly as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Volts transformers
Supply only Tap Changer as per existing size, shape and specification complete for capacity 350 to 500 KVA , 11/0.433 Volts transformers
Supply only Tap Changer as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply only Tap Changer as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Volts transformers
Overhauling servicing of tap changer and replacement of unserviceable parts as ordered with new and assembling c with old serviceable parts for smooth functioning and operation complete as all specified and as directed
Dehydration and filtration of existing transformer oil of transformers capacity ranging from 50 KVA to 3150 KVA ( 33 KV System step down to 33/11 KV and 11 KV System step down to 11/0.433 KV) on site at different locations without disturbing the power supply system with filtration machine and heating system in order to achieve Di-electric strength of oil 40KV minimum at 2.5 mm gap complete all as specified and as directed.
Supply & filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacement up to desired level of transformer oil capacity complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] (Make : GULF/POWER OIL or equivalent as approved by GE)
Supply and fixing as in replacement Temperature Guage as per existing size, shape and specification complete for capacity 350 to 500 KVA , 11/0.433 Volts transformers
Supply and fixing as in replacement Temperature Guage Changer as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply and fixing as in replacement Temperature Guage as per existing size, shape and specification complete for capacity 50 to 150 KVA, 11/0.433 Volts transformers complete all as specified and directed.
Supply and fixing as in replacement pair of arcing horns suitable for transformer capacity 50 to 500 KVA, 11/0.433 Volts complete all as specified and directed.
Supply and replacing silica gel in crystal form of breather assembly of transformer capacity upto 3150 KVA at installed site complete all as specified and directed.
Material and Labour for Earthing complete with Galvanised Steel Earth Plate Electrode 600 x 600 x 6mm, thick buried directly in ground ( earth pit not less than 2.25 Metre deep below the Ground Level ) with Top Edge of Earth Plate not less than 1.50 Metre deep below normal ground level , connected to Galvanised steel iron earth lead wire 32x6mm dia by means of Bolts, Nuts, Check Nuts and Washers made of Galvanised Iron 20 mm dia GI Pipe (Med grade) for watering, 40 mm dia GI Pipe light grade for protection of earth lead wire,including necessary earth work in any type of soil , PCC (1:3:6) Type C1 Concrrete pit RCC (1:1.5:3) Type A1 Precast cover (54x54x5Cm) duly reinforced with including 8mm Dia TMT Bar @ 150 mm c/c both ways lifting handle made of 8mm dia TMT Bar embeded in precast cover slab complete as shown in electrical Plate No 3 of SSR Part-I including testing on completion complete all as specified and as directed.
Servicing / Removing the existing, relay units (two over current relays and one earth fault relay) of any make and cap from the cubical panel and carrying out servicing including cleaning, fitted, cradle contacts with Emery paper wiping gently, cleaning,and adjusting yoke, replacing burnt tripping coil etc incl calibration of IDMT relay in VCBs and tuning with other VCBs as reqd (so that incoming VCBs trips on fault before 33KV VCB and outgoing VCBs trip before incoming VCBs) Testing of IDMT relay with the help of primary / secondary injection all as specified as per manufacturer specification.
Servicing / Removing the existing, relay units (two over current relays and one earth fault relay) of any make and cap from the cubical panel and carrying out servicing including cleaning, fitted, cradle contacts with Emery paper wiping gently, cleaning,and adjusting yoke, replacing burnt tripping coil etc incl calibration of IDMT relay in VCBs and tuning with other VCBs as reqd (so that incoming VCBs trips on fault before 11KV VCB and outgoing VCBs trip before incoming VCBs) Testing of IDMT relay with the help of primary / secondary injection all as specified as per manufacturer specification.
M&L spring charging motor for 11 KV VCB, 240 Volt, AC complete all as specified and directed complete all as specified and directed by Engr-in-charge.
M & L for replacement of digital type over current earth fault relay with communicable port with hih set adjustable of current setting range., complete all as specified and directed by engr-in-charge.
Supply and fixing high speed master trip relay type VAJ 110 V DC
Supply and fixing Resin cast VCB enclosure
Supply and fixing racking rack out pinion
Supply and fixing LED Lamp, 110V, DC
M/S S.S.Corporation
PURBANCHAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .