| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹1.1 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.1 Cr+₹4.4 L (4.04%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.1 Cr+₹4.4 L (4.04%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹1.1 Cr+₹5.2 L (4.76%)Rejected-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹1.1 Cr+₹5.2 L (4.76%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹1.2 Cr+₹5.8 L (5.33%)Rejected-Finance | ₹1.2 Cr+₹5.8 L (5.33%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹1.4 Cr+₹34.8 L (31.8%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹1.4 Cr+₹34.8 L (31.8%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
20 May 2025, 6:00 pmClosed
CWE (AF) Palam
CWE (AF) Palam, Delhi Cantt-10
ADDN/ALTN TO SMQs AT HQ WAC (U) SUBROTO PARK UNDER GE (AF) SUBROTO PARK DELHI CANTT-10
2025_MES_703612_1
CWE/PM/SP-01/2025-26
Open Tender
Civil Works
Item Rate
365 days
Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
GE (AF) Subroto Park
₹2.2 L
2 Jul 2025
4 Apr 2025
27 May 2025
4 Apr 2025
20 May 2025
6 May 2025
Amount
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc. 15 cm thickness( below or above ground floor) complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC (1:5:10) type E-2 using 40 mm graded brick aggregate as in sunken portion complete all as specified and as directed by Engineer-in-Charge.
M & L for cleaning the sunken floor surfaces by wire brushes, brooming, removing dust by dismantling of floor, lime terracing and applying following :- (a) 10 mm thick screed bed in cement mortar 1:3 complete mixed with water proofing compound as per manufacturers instructions complete all as specified and directed. (b) Bitumen primer confirming to IS-3384-1965 @ 0.50 Kg Per sqm. (c) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm confirming to IS - 702-1998 for water proofing membrane. (d) Applying of polymeric water proofing membrane weight not less than 3 Kg/Sqm over entire area with overlaps and sealed all as specified directed. (e) Again applying a tack coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm over water proofing membrane. (e) Dusting dry sand @ 0.75 Kg Per Sqm over water proofing membrane. Note : Spout tube shall be measured & paid separately.
Supply only Liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 32 mm dia galvanised iron steel tube light grade for sunken portion complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) excluding flushing cistern and flush pipe and including P or S trap complete all as specified and as directed by Engineer-in-Charge.
S&F plastic water closet seat cover white closed pattern with flat bottom and cover incl mild steel chromium plated hinging device complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC flushing cistern, valveless, symphonic action type, 10 Ltr capacity, low level, white, with inlet, ball valve, float and handle including bracket complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster etc on brick wall or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and disposed off unserviceable materials to outside MOD land complete all as specified and as directed by Engineer-in-Charge.
M&L 12 mm thick cement mortar 1:6 on uneven surface of brickwork or concrete surfaces on wall surface, finished even and smooth without using any extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling, complete all as specified and as directed by Engineer-in-Charge.
M&L 15 mm thick cement mortar 1:4 on other than fair faces of brick work or concrete surfaces on wall surface, finished even and smooth without using any extra cement complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr in Charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but n. exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cm (1:4) complete all as specified and as directed by Engineer-in-Charge.
M&L non skid ceramic coloured tiles 10 mm thick (square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors/dado etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cm (1:4) complete all as specified and as directed by Engineer-in-Charge.
M&L Glazed coloured ceramic tiles in vertical surface/ dado 450X 300X 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L Green marble 18-20 mm thick machine cut , bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 15 mm thick screed bed (1:6 CM) including dismantling of old stone slab complete all as specified and as directed by Engineer-in-Charge.
S&F in repair kitchen sinks of bowl size 410mm x 330 mm made of stainless steel 1 mm thick with waste coupling and waste pipe complete all as specified and as directed by Engineer-in-Charge.
Taking down door chowkats or frames with shutters, any type (without taking off shutters from the frame) area not exceeding 1.50 sqm complete all as specified and as directed by Engineer-in-Charge.
Taking down door chowkats or frames with shutters, any type (without taking off shutters from the frame) area exceeding 1.5 sqm but n.exc 4.0 sqm complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any description exc 1 sqm but n.exc 2.0 sqm each and removal to store complete all as specified and as directed by Engineer-in-Charge.
S&F pressed steel frames for doors with one or more rivets including necessary fixing lugs, hinges, lock strike plate etc of size 105 x 60mm filling with 1:3:6 PCC complete all as specified and as directed by Engineer-in-Charge.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc of size 165 x 60mm filling with 1:3:6 PCC ccomplete all as specified and as directed by Engineer-in-Charge.
S&F 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and as directed by Engineer-in-Charge.
S&F 2nd class HW glazed and skelton 35mm thick shutters, open rebated and prepared to receive glass gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass Gauze etc complete all as specified and as directed by Engineer-in-Charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer-in-Charge.
S&F mild steel helical door spring 300 mm ordinary rat tail type incl roller and roller plate fixed with screws to wooden frame or with welding to steel frames complete all as specified and as directed by Engineer-in-Charge.
M&L 18/19 mm thick pre-laminated particle board interior grade pre-laminated one side with decorative choice laminating & other side balancing white lamination including external teak wood lipping 12 mm thick fixed with nails on external edges fixed with screw to frame work for cupboard shutter and shelves including taking down old one complete all as specified and as directed by Engineer-in-Charge.
M&L 18/19 mm thick pre-laminated particle board interior grade both sides balancing white lamination fixed with screw to angle frame work for cupboard shutter and shelves including taking down old one complete all as specified and as directed by Engineer-in-Charge.
S&F continuous piano hinges, mild steel, bright finish or electro galvanised, width of flap 30mm complete all as specified and as directed by Engineer-in-Charge.
M &L for 125 mm magnetic catches with brass body and striking plate including letting in and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F for 125 mm size of hasp & staple safety type aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for galvanised rigid steel conduit 20 mm ext dia pipe for hanger rods including necessary arrangement to fixed in cup board complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair windows/ ventilators fabricated from 0.60mm thick roll formed section made of galvanised steel powder coated (Base steel as per IS-513"D" quality) galvanised as per IS-277 with ZINC of 120GM/SQM . Windows /ventilators having frame suitable for dual shutter i.e. inner and outer shutter with grill, glazed and wire mess shutter and all fitting, fixtures accessories incl 6mmx12mm flat iron with 10mm square bar M.S. grills complete as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(4000 series) NOTE: (i) Glazed shutter with 4.00 mm thick glass, mesh shutter with 32 gauge stainless mesh and MS grill is deemed to be inclusive in the rate quoted for unit (ii) Glass, stainless steel mesh will be fixed to window by authorised rep of manufacturer of window only. Rate including taking down of windows and making good the surface.
Supply and fixing in repair windows / ventilators fabricated from 0.60mm thick roll formed section made of galvanised steel powder coated (Base steel as per IS-513"D" quality) galvanised as per IS-277 with ZINC of 120GM/SQM . Windows /ventilators having frame suitable for single shutter with grill, glazed shutter and all fitting, fixtures accessories incl 6mmx12mm flat iron with 10mm square bar M.S. grills complete as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(3000 series) NOTE: (i) Glazed shutter with 4.00 mm thick frosted/plain glass, mesh shutter with 32 gauge stainless mesh and MS grill is deemed to be inclusive in the rate quoted for unit (ii) Glass, stainless steel mesh will be fixed to window/ventilator by authorised rep of manufacturer of window/ventilator only. Rate including taking down of windows and making good the surface.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with SS wire staples complete all as specified and as directed by Engineer-in-Charge.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with SS wire staples complete all as specified and as directed by Engineer-in-Charge.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube complete as per manufacturer’s specification & drawing complete all as specified and as directed by Engineer-in-Charge.
S & F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottoms rails MS frame shall be covered with heat moulded plain colour PVC C Channel having a PVC sheet strip of 20 MM width stuckin side with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail in either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded and sealed to the styles and rail with suitable PVC sheet beading and joint together with solvent cement complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Butt hinges, medium wt, cold rolled, mild steel of size 100mm complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed by Engineer-in-Charge.
S&F 200 mm length aluminium, anodized, barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-Charge.
S&F 150 mm size aluminium handle, cast type anodized complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete all as specified and as directed by Engineer-in-Charge.
S&F 15 mm bore steel tubing galvanized medium grade with all fittings and fixed concealed to walls and ceiling or laid in floors complete all as specified and as directed by Engineer-in-Charge.
S&F 20 mm bore steel tubing galvanized medium grade with all fittings and fixed concealed to walls and ceiling or laid in floors complete all as specified and as directed by Engineer-in-Charge.
S&F in repair brass chromium plated shower rose 125 mm size with swivel joints including fixing to pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repair brass, 15 mm dia bore CP wall mixture (water saving) with all accessories complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 15 mm dia CP bib cock long body with wall flange (water saving tap) cast copper alloy, screwed for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S & F in repair for 15 mm bore angle valve cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, for iron pipe or for unions complete all as specified and as directed by Engineer-in-Charge.
S&F in repair brass 15 mm dia bore CP sink mixture (water saving) with all accessories complete all as specified and as directed by Engineer-in-Charge.
S&F in repair CP stainless steel towel ring complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm dia two in one CP bib cock long body with wall flange (water saving tap) cast copper alloy, screwed for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Hand Shower (Health Faucet) (ABS body) mild steel with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs CP grating round 100mm dia with hole of PTMT (min weight 25 gms) complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC connection of 45 cm long with 2 Nos PTMT side nuts screwed with iron pipe of 15 mm dia complete all as specified and as directed by Engineer-in-Charge.
S&F in repair stainless steel soap dish, any type, fixed to plugs with chromium plated brass screws embedded in wall complete all as specified and as directed by Engineer-in-Charge.
S&F in repair vitreous china WHB white, flat back, size 550 x 400mm including brackets, coupling and all accessories etc complete all as specified and as directed by Engineer-in-Charge.
S&F in repair C.P tubular Towel rail 20 mm dia, D type 60 cm long complete all as specified and as directed by Engineer-in-Charge.
S&F in repair wash hand basin CP mixture swan neck tap left /right/front operated knob (water saving) screwed for iron pipe and fixed 15mm bore complete all as specified and as directed by Engineer-in-Charge.
S & F in repair corner glass shelf with bracket complete all as specified and as directed by Engineer-in-Charge.
S & F in repair front glass shelf with bracket complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs 32mm bore and 75cm long PVC flexible waste pipe for WHB/urinal complete all as specified and as directed by Engineer-in-Charge.
S&F in repair curtain rods, mild steel conduit pipe 20 mm bore including temples, brackets etc complete all as specified and directed by Engineer-in-Charge.
M &L two coats of synthetic enamel paint over a coat of pink primer including preparation of newly wooden surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L one coat of synthetic enamel paint including preparation of old wooden surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L one coat of synthetic enamel paint including preparation of old steel surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L two coats of synthetic enamel paint over a coat of red oxide primer including prepration of newly steel surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L Preparation of newly plastered or unplastered surface and applying two coats of oil bound distemper over a coat of primer including 2 mm thick wall care putty on walls complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stopping of existing surface and making the surface even and smooth and apply Two coats of oil bound distemper including 2 mm thick wall care putty on walls complete all as specified and as directed by Engineer-in-Charge.
M&L preparation of newly plastered surface and applying three coats of white wash on ceilings complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of ceiling by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stopping of existing surface and making the surface even and smooth and apply two coats of white wash on ceilings complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of newly plastered or concrete surfaces of wall and applying two coat of weather coat exterior emulsion over a coat of primer complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stopping of existing surface and making the surface even and smooth and apply two coat of weather coat exterior emulsion and including a coat of primer complete all as specified and as directed by Engr-in-Charge.
M & L for PCC 1:2:4 type B1 (20 mm graded stone aggregate) as in bed for PVC water tank, roof kerbs benching rounded, parking flooring edge complete all as specified and as directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm graded stone aggregate including making joints & filling with sand bitumen mastic complete all as specified and as directed by Engineer-in-Charge.
S&F in repair SS 900x800 plate rack fixed in position including all necessary fittings all as specified and directed by Engr In- Charge.
M&L for repair to broken sides/bottom of roof projection, facia, column, chajja etc by all means i.e. either by cement plaster of any thickness or by cement concrete 1:1.5:3, type A-0, using 12.5 mm graded stone aggregate etc, using chicken wire mesh to reinforce & form work as required with two coat of weather coat complete all as specified and as directed by the Engineer-in-Charge.
M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
M & L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror polish including dismantling of old slab complete all as specified and as directed by Engineer-in-Charge. Note : Screed bed shall be measured and paid separately.
M/L for machine cut kota stone slab 25mm thick as in riser of steps, skirtings, dados etc over 10 and including mm thick cement screed in cm (1:6) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror polish including dismantling of old slab complete all as specified and as directed by Engineer-in-Charge.
Taking down rainwater pipes (any Size or pattern), including all fittings, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) pipes of 110 mm bore single socketed, in any length with rubber ring joints, fixed with walls or trenches complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) bends any radius for 110 mm bore PVC pipe with cement joints complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) junction single,(Single T) equal or unequal, 110 mm dia complete all as specified and as directed by Engineer-in-Charge.
Dismantling of CI pipe incl all fittings from wall/trenches any type & any size complete all as specified and as directed by Engineer-in-Charge.
S & F 75 mm dia cast iron soil/waste pipe in any length with or without ears with cement joints laid in trenches or in floors etc complete all as specified and directed by Engr -in - Charge .
S & F 100 mm dia cast iron soil/waste pipe in any length with or without ears with cement joints laid in trenches or in floors etc complete all as specified and directed by Engr -in - Charge.
S&F CI bends any radius for 100 mm bore CI pipe with cement joints complete all as specified and as directed by Engineer-in-Charge.
S&F CI bends any radius for 75 mm bore CI pipe with cement joints complete all as specified and as directed by Engineer-in-Charge.
S&F 75 mm dia CI Branch pieces, T Section, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F 100 mm dia CI Branch pieces, T Section, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F CI vent cowl 75 mm complete all as specified and as directed by Engineer-in-Charge.
S&F CI gully trap 125/110 mm setting and jointing with solvent complete all as specified and as directed by Engineer-in-Charge.
S&F CI floor trap 75mm with grating including jointing with solvent complete all as specified and as directed by Engineer-in-Charge.
Demolition of any type of roof treatment (i.e App membrance, brick tiles, mud phuska, cement concrete/ lime concrete etc ) from roof any thickness including leaping plaster including removing the demolished material from roof outside defence land complete all as specified and directed by Engineer-in-Charge.
M & L for cement concrete 1:2 :4 type B-0(using 12.5 mm graded stone aggregate) laid as in padding over roof slabs with and including WPC as per manufacturer instruction for providing proper slope including finishing surface even & fair by using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gms polyester non-woven fabric with scratched tool before finishing roof surface. When the concrete surface is still green, the roof surface shall be thoroughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 / kg at 25 degree and viscositing of 70 to 160 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied. APP membrane shall be laid on primed surface touch application method after allowing 24 hours of primer to dry. Laying of APP membrane shall be commenced at the lowest level and worked upto the crest.APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with butane touch. This treatment shall be done by the approved authorised applicator. Guarantee of treatment shall be for 10 years. Thereafter APP membrane shall be painting with two coat of water proofing paint with aluminium finish. (ii) Independent testing of membrane for the approval technical parameters specified hereinafter shall be carried out the approved laboratories like National test house any other Govt approved laboratory having facilities for the testing of membrane.
S&F in repair to rotational moulded vertical water storage tanks triple layer ( White colour) with closed tops ( cylindrical ) hoisted and fixed in position 500 litre capacity including disconnecting and refixing the existing GI fitting and pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair of gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2, screwed for iron pipe of size 20 mm bore complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, precast concrete blocks etc complete all as specified and as directed by Engineer-in-Charge.
M & L for brick work with sub-class `B' bricks old size, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M & L framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand and similar work conforming to Fe 290,Gde - E-165 complete all as specified and as directed by Engineer-in-Charge.
M&L for post Anti Termite Treatment of soil under existing floors using emulsion @ 01 litre / hole, 300mm apart including drilling & plugging 12mm dia holes with CM(1:2) to match the existing floors complete all as specified and as directed by Engineer-in-Charge.
M&L for post Anti Termite Treating the soil under plinth protection @ 5 liters of emulsion / Sqm of surface area complete all as specified and as directed by Engineer-in-Charge.
M &L post Anti termite treatment along the external wall below concrete or masonry apron and wooden joinery using chemical emulsion @ 2.25 liters / m including drilling & plugging holes etc. in apron complete all as specified and as directed by Engineer-in-Charge.
S&F in repair factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cum. One side prelam and other side plain 18mm thick Celuka PVC ply for kitchen cabinet shutter complete all as specified and as directed by Engineer-in-Charge.
S&F in repair factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cum. Plain 18mm thick Celuka PVC Ply for Shelf/Partitions/Drawer complete all as specified and as directed by Engineer-in-Charge.
S&F factory made 5mm thick PVC sheet of density 600kg/cum. Plain 5mm thick PVC sheet paneling for back side(wall side) complete all as specified and as directed by Engineer-in-Charge.
S&F 100 mm size Stainless Steel handle complete all as specified and as directed by Engineer-in-Charge.
M &L for 50 mm magnetic catches with brass body and striking plate including letting in and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F 38mm size Stainless Steel Piano hinges complete all as specified and as directed by Engineer-in-Charge.
M&L for concrete 1:3:6 type C1 using 20mm graded aggregate as in coping, bed plates and the like including necessary formwork and finishing the surface fair and even without using extra cement complete all as specified and as directed by Engineer-in-Charge.
M & L rendering 15mm thick on other than fair faces of brick work in CM 1:4 finished even & smooth without using extra cement including 3% WPC by weight of cement all as specified and directed by Engineer-in-Charge .
Excavation in trenches n.exc 1.5m wide and n.exc1.5 m in depth for foundation, or shafts, wells, cess pits manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed by Engr-in-charge.
Demolition and breaking up drain pipes internal dia / bore of pipe 200mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including haunching in any description and disposed from MOD land . complete all as specified and directed by the Engineer-in-Charge.
S&F 200mm bore (inner dia) double wall corrugated HDPE pipes (SN8) in any length including all fittings and jointing with elastomeric rubber rings and couplers / other jointing materials as per manufacturers instructions, complete all as specified and as directed by Engineer-in-Charge.
M & L for concrete bed PCC 1:4:8 Type D2 (Using 40mm graded stone aggregate) to drain pipes 200. mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and as directed by Engr-in-Charge.
Returning & filling in including spreading, leveling, watering & well ramming in layers n.exc 25mm thick in soft/ hard/ dense soil complete all as specified and directed by Engineer-in-charge.
Removing surplus excavated material out side MOD land complete all as specified and directed by Engr-in-Charge.
S&F in repair factory made SFRC manhole/drain cover (Grade M-25) heavy duty cover slab in rectangular shape of size as required 80 mm thick incl MS sheet 2 mm thick and 80 mm wide all around the cover complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC (1;4:8 ), Type D2, using 40mm graded mechanically crushed store aggregates as in foundations, filling, sub base and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for sand filling under floor cushioning for interlocking tiles including water consolidation complete all as specified and as directed by Engineer-in-Charge.
M&L for 60 mm thick M-35 grade machine pressed precast concrete interlocking paver block coloured (Red/Yellow) in any shape and size with grey cement and pigment as approved conforming to IS-15658-2006 complete all as specified and as directed by Engineer-in-Charge.
Disconnection and restoration of PNG connection alongwith removal and refixing of PNG meter and necessary pipe line need to be essentially of SMQs wherever renovation/repair being under taken in kitchens complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for concealed point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI 694 marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs with all fittings including Tee, Junction boxes and pressed steel terminal powder coated box of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the quoted rate of item.
For one light point controlled by one SP switch
For one fan/exhaust fan and wall mounted fan point controlled by one SP switch.
For one light point controlled by two 2 - way SP switches
For one bell point controlled by one No bell push
All as per item No 130 here-in-before but for one 3 pin socket outlet, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No 130 here-in-before but for one 3 pin socket outlet, 6 Amps on Independent board with the cable 1.5 Sqmm size complete all as specified and as directed by Engineer-in-Charge.
All as per item No 130 here-in-before but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.
S&F switch piano 5 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet flush type 3 pin 6 amps suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano 5 Amps flush type single pole two way suitable for 240 volt AC complete all as specified and as directed by Engineer-in-Charge.
S&F switch piano 16 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix bell push flush type 5 Amps suitable for 240 volt complete all as specified and as directed by Engineer-in-Charge.
Supply and fix bell AC 240 volt ding dong type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm ,3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair of surface mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with three core copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing in repair of surface mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with three core copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
S &F in repair of Decorative, wall mounting, champagne gold finish fixture with plastic body suitable upto 15 W LED lamp B22 base with flexible copper wire, three core cable complete all as specified and directed by Engineer-in-Charge. Note- The unit quoted rate inclusive of one no 12 watt LED lamp suitable for B22 base.
Supply and fixing in repair of LED security light fitting 35 watt high pressure dia cast aluminium housing and secondary optical lens for superior light distribution , heat resistant toughened glass with frame, IP66 protection complete with lamp & connected item and connection with suitable cable from ceiling rose to light fitting and fixing on GI bracket made out of suitable GI Pipe medium grade 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nuts bolts washer etc complete all as specified and as directed by Engineer-in-Charge.
Taking down including disconnecting the electric connection of ceiling fan and dismantling blades, greasing complete all as specified and as directed by Engineer-in-Charge.
Hanging / fixing only ceiling fan received from item No 148 here-in-before and connecting up with suitable size of copper cable from connector of fans to ceiling rose complete all as specified and as directed by Engineer-in-Charge.
Taking down including disconnecting the electric connection of exhaust fan and dismantling blades, greasing and painting the whole assembly complete all as specified and as directed by Engineer-in-Charge.
Fixing only Exhaust fan received from item No 150 here-in-before and connecting up including fastener and suitable size of copper cable from connector of fans to ceiling rose complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable submain wiring of alluminium two/three runs of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
M & L for submain wiring with three run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked drawn through suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings concealed in wall or surface conduit on ceiling portion complete all as specified and directed by Engineer-in-charge. Note : (i)3 runs of cable and conduit will measured one unit for payment purpose. (ii) Cost of cutting chasing and matching with existing surface also included in the unit quoted rate of item.
M & L for submain wiring with three run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked drawn through suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings concealed in wall or surface conduit on ceiling portion complete all as specified and directed by Engineer-in-charge. Note : (i)3 runs of cable and conduit will measured one unit for payment purpose. (ii) Cost of cutting chasing and matching with existing surface also included in the unit quoted rate of item.
M & L for disconnecting single phase electric meter -14 nos from the meter box panel and keeping in safe custody for refixing purpose as per the same qtr and removing the old meter box panel from the site complete all as specified and directed by engineer-in charge.
Supply installation testing and commissioning of meter box panel indoor type made out of 2.00mm thick CRCA sheet totally enclosed dust & vermin proof including internal wiring with suitable size of copper conductor wire PVC insulated FRLSH including dismantling of old meter box. The meter box should have separate cubical for each meter . The panel comprising the followings. 1 Incoming MCCB 200 Amps 4 pole 25 KA ,Ics=100%Icu -01 No 2 Outgoing MCB 63 A 10 KA SPN 'C' CURVE -15 Nos 3 Separate cubical space for single phase prepaid electric meter with glass display opening -15 Nos 4 Indicating LED type RYB -01 No 7 Danger note Plate-01 No 8 Bus bar chamber TPN 400 Amps aluminium-01 set 9 Fixing arrangement to fix meter Note: Fixing of 14 Nos single phase prepaid electric meter retrieved from item no 155 also included in the unit quoted rate of this item.
Taking down old unsv MCB DB SPN of any size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid separately.
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply complete all as specified and as directed by Engineer-in-Charge.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SP 40 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
M&L for taking down existing geyser carefully of any capacity without damaging from bathroom and to be kept in safe custody untill completion of finishing work and re-fixing the same after completion of work, complete all as specified and as directed by Engr in charge.
M&L in repair for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair round shape 12 watt 220 volts AC ,6000 K , surface type with efficiency not less than 100 lumen/watt complete with drivers, holders LED lamp including connecting up with necessary PVC sheathed 3 core flexible copper wire complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote control complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed by Engineer-in-Charge.
BRIJ MOHAN LAL AND CO. (BID ID -3301176)
L G BUILDERS (BID ID -3296209)
M/s. Kansal Construction Co. (BID ID -3295878)
J.P. Enterprises (BID ID -3295914)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .