| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | ₹4.6 L | L1 | Admitted-Finance |
| 2 | L2₹8.2 LAdmitted-Finance | ₹8.2 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | satwik services pvt. ltd. L2 | M/S International Water Care L1 |
|---|---|---|---|---|---|
| 1.00Mechanised cleaning | |||||
| 1.01 | Cleaning and disinfection of Clear Water Reservoir (CWR) and Over Head Service Reservoir (SR) with mechanized equipment such as high pressure jet pump for cleaning of under sides of clear water tanks, removal of sludge and other foreign matter in tank if any. The sludge from the tank would be removed in the shape of sludge slurry with the mechanized pump.A Work Specification,Mechanized cleaning of storage tank comprises of 6 stages as mentioned belowStage-I Mechanised dewatering. Stage-II Desilting and removal of left over dirty water and sludge with a sludge removal pump. Stage-III Cleaning of wall, ceiling and floor by high pressure water jet with the help of equipment which creates a pressure of 100 150 Bar. Stage-IV Removal of remaining sludge from the floor with the help of industrial vaccum cleaner. Stage-V Spraying of non toxic, bio-degradable, ecofriendly anti bacterial agent certified by a Govt. approved laboratory to disinfect the tank from all harmfull pathogens. The dose utilised should be safe as per the OECD guidelines 423 adopted on 17 Dec. 2001. Stage-VI Treatment of inside tank by exposing UV radiation to kill further suspended or floating bacteria if any. The contractor will specify the date of cleaning of tanks on each SR and CWR. The contractor has to execute the cleaning work 2 times in a year(at every six months)B Eligibility Criteria of Experience1 Contractor having experience for executing similar order for value equal or more than Rs. 10.06 lacs. 2 Contractor having experience for cleaning single tank sizing more than or equal to 10.80 lac litres, 60 percent of maximum capacity 18.0 lac litre with similar process. 3) Contractor should be ESI and PF registered. 4) Execution team should be tested as medically fit by authorized Doctor. 5) Certificate for non toxicity of anti bacterial as per the OECD guidelines, need submitted by the contractor.The work specifications and Eligibility is required as per office order no. ACE 2009-10 1238 dated 16.03.2009,Copy of office order is attached. The contractor has to Details of capacities of reservoirs are as under Clear Water Reservoir CWR I/A Chopanki 900 kilo litre, I/A Chopanki 900 kilo litre, I/A Khushkhera 1800 kilo litre, I/A Pathredi 1600 kilo litre, I/A IID Centre Khushkhera 260 kilo litre, I/A Tapukara 400 kilo litre, I/A Bandapur 250 kilo litre, I/A Karoli - Industrial Zone - 1600 KL, I/A Karoli - Residential Zone - 600 KL, Total 8310 kilo litre. Over Head Service Reservoir SR IA Chopanki 900 kilo litre, I/A Chopanki 900 kilo litre, I/A Pathredi 800 kilo litre, I/A Khushkhera 900 kilo litre, I/A IID Centre Khuskhera 130 kilo litre, I/A Tapukara 400 kilo litre, I/A Bandapur 150 kilo litre, I/A Karoli - Industrial Zone - 800 Kilo litre, I/A Karoli - Residential Zone - 300 Kilo litre, Total 5280 kilo litre, | 27,180 | per kilo litre | 30 ₹8,15,400 | 17 ₹4,62,060 Lowest |
Tender Value
₹10.1 L
EMD Value
₹20,113
Closing Date
22 Jun 2026, 11:00 amClosed
Unit Head RIICO Bhiwadi II
RIICO Bhiwadi II office
Mechanised Cleaning of CWR and SR at all Ind. areas of Bhiwadi -II
2026_RIICO_565950_3
2026-27/10/01-05
Open Tender
Civil Works
Percentage
365 days
Bhiwadi II
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
RIICO
₹20,113
9 Jul 2026
10 Jun 2026
23 Jun 2026
10 Jun 2026
22 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Mechanised cleaning | |||||
| 1.01 | Cleaning and disinfection of Clear Water Reservoir (CWR) and Over Head Service Reservoir (SR) with mechanized equipment such as high pressure jet pump for cleaning of under sides of clear water tanks, removal of sludge and other foreign matter in tank if any. The sludge from the tank would be removed in the shape of sludge slurry with the mechanized pump.A Work Specification,Mechanized cleaning of storage tank comprises of 6 stages as mentioned belowStage-I Mechanised dewatering. Stage-II Desilting and removal of left over dirty water and sludge with a sludge removal pump. Stage-III Cleaning of wall, ceiling and floor by high pressure water jet with the help of equipment which creates a pressure of 100 150 Bar. Stage-IV Removal of remaining sludge from the floor with the help of industrial vaccum cleaner. Stage-V Spraying of non toxic, bio-degradable, ecofriendly anti bacterial agent certified by a Govt. approved laboratory to disinfect the tank from all harmfull pathogens. The dose utilised should be safe as per the OECD guidelines 423 adopted on 17 Dec. 2001. Stage-VI Treatment of inside tank by exposing UV radiation to kill further suspended or floating bacteria if any. The contractor will specify the date of cleaning of tanks on each SR and CWR. The contractor has to execute the cleaning work 2 times in a year(at every six months)B Eligibility Criteria of Experience1 Contractor having experience for executing similar order for value equal or more than Rs. 10.06 lacs. 2 Contractor having experience for cleaning single tank sizing more than or equal to 10.80 lac litres, 60 percent of maximum capacity 18.0 lac litre with similar process. 3) Contractor should be ESI and PF registered. 4) Execution team should be tested as medically fit by authorized Doctor. 5) Certificate for non toxicity of anti bacterial as per the OECD guidelines, need submitted by the contractor.The work specifications and Eligibility is required as per office order no. ACE 2009-10 1238 dated 16.03.2009,Copy of office order is attached. The contractor has to Details of capacities of reservoirs are as under Clear Water Reservoir CWR I/A Chopanki 900 kilo litre, I/A Chopanki 900 kilo litre, I/A Khushkhera 1800 kilo litre, I/A Pathredi 1600 kilo litre, I/A IID Centre Khushkhera 260 kilo litre, I/A Tapukara 400 kilo litre, I/A Bandapur 250 kilo litre, I/A Karoli - Industrial Zone - 1600 KL, I/A Karoli - Residential Zone - 600 KL, Total 8310 kilo litre. Over Head Service Reservoir SR IA Chopanki 900 kilo litre, I/A Chopanki 900 kilo litre, I/A Pathredi 800 kilo litre, I/A Khushkhera 900 kilo litre, I/A IID Centre Khuskhera 130 kilo litre, I/A Tapukara 400 kilo litre, I/A Bandapur 150 kilo litre, I/A Karoli - Industrial Zone - 800 Kilo litre, I/A Karoli - Residential Zone - 300 Kilo litre, Total 5280 kilo litre, | 27,180 | per kilo litre | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.87 MB
TDmerged.pdf
Tender Documents • 4.41 MB
BOQ_1007040.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].