| Sl No | Description | Qty | Unit | Unnati Engineers L2 | Industrial Traders L4 | shivam builders L1 | Lucknow Refrigeration L3 |
|---|---|---|---|---|---|---|---|
| 1.00M & L for periodical services, cleaning and testing various type equipment 33/11 KV equipments in switch yard and other connected works etc complete as specified and directed for the following :- | |||||||
| 1.01 | Line isolator, 33 KV (Horizontal type) :- Servicing of line isolator (Horizontal break outdoor type) including cleaning of contact (knife) by CTC liquid proper oiling greasing on contacts & moving rod / handle for proper function of moveable rod for smooth ON / OFF position and checking, tightening the incoming and outgoing connection (terminal lugs to be replaced if required as per existing size with GI nut bolts, washer) and testing with following (i) Megger testing between phase to phase & phase to earth shall be carried out complete all as specified and directed. | 9 | Each | 1,500 ₹13,500 | 301 ₹2,709 Lowest | 2,800 ₹25,200 | 3,500 ₹31,500 |
| 1.02 | HT Potential Transformer (33 KV / 110 Volt) :- Cleaning of bushing and terminal of HT potential transformer 33000 / 110 volts (outdoor type) by CTC liquid and checking of oil level including rectification of any type of leakage and proper connection checking and testing complete all as specified and directed with following :-
(i) Megger testing between phase to phase & phase to earth
(ii) Checking output voltage
(iii) Testing the oil dielectric strength (BD test) | 4 | Set of 3 | 2,000 ₹8,000 | 301 ₹1,204 Lowest | 3,200 ₹12,800 | 4,200 ₹16,800 |
| 1.03 | HT Vacuum Circuit Breaker (VCB) 33 KV :- Cleaning & servicing of HT 33 KV vacuum circuit breaker (VCB) 400/630/1250 Amp, 3 phase, outdoor type, checking of each moving parts, spring, charging system, closing & trip coil assembly and proper oiling, greasing and proper adjustment of trip bars, closing bar complete all as specified and directed with the following testing :-
(i) ON/OFF testing in local and remote position.
(ii) Spring charge system testing shall be carried out.
(iii) Tripping test in over and earth fault position by external current injecting Kit on Primary Secondary side.
(iv) Megger testing between phase to phase and phase to earth in ON / OFF position both. | 3 | Each | 25,000 ₹75,000 | 1,202 ₹3,606 Lowest | 7,500 ₹22,500 | 4,500 ₹13,500 |
| 1.04 | HT 33 KV Current Transformer (CT) :- Cleaning of bushing and terminal by CTC solution of CT rating 100 / 5 + 5 + 1 Amp rating, 33 KV and checking of oil level, rectify leakages if any and testing the oil strength (BD test) and proper connection checking and testing complete all as specified and directed with following :-
(i) Megger testing between phase to phase& phase to earth | 3 | Set of 3 | 5,000 ₹15,000 | 301 ₹903 Lowest | 2,500 ₹7,500 | 4,200 ₹12,600 |
| 1.05 | 33 KV VCB Control & Relay Panel :- Cleaning of control & relay panel inside & outside by CTC solution and checking all the control cable connection of CT, PT, VCB, meters, trivector meter transformer complete all as specified and directed. | 3 | Each | 5,000 ₹15,000 | 301 ₹903 Lowest | 2,500 ₹7,500 | 3,100 ₹9,300 |
| 1.06 | Transformer 33 / 11 KV, 2 MVA :- Cleaning of power transformer 33 /11 KV, 2 MVA, outdoor type externally including all accessories (such as conservator tank, marshaling box, bushings, buchholz relay Radiator, bushings oil level indicator,rectify the leakage (if any) complete and checking the incoming and outgoing terminal connection complete all as specified and directed with the following testing :-
(i) Transformer oil dielectric strength (BD voltage) test.
(ii) buchholz relay Alarm & trip testing.
(iii) Oil temperature Alarm & trip testing.
(iv) Winding temperature Alarm & trip testing.
(v) Megger testing between HV to earth.
(vi) Megger testing between LV to earth.
(vii) Megger testing between HV to LV .
(viii) Earth resistance test of transformer neutral.
(ix) Earth resistance test for body earthing.
(x) Replacement the all packing in marshalling box (if required) | 2 | Each | 2,500 ₹5,000 | 1,503 ₹3,006 Lowest | 5,500 ₹11,000 | 4,500 ₹9,000 |
| 1.07 | Transformer 33/ 0.433 KV, 100 KVA (Station Transformer) :- Cleaning of station transformer (outdoor type) externally including all accessories and checking of all incoming & outgoing connection and rectify the leakages if any complete all as specified and directed with the following testing :-
(i) Transformer oil dielectric strength (BD) test.
(ii) Megger testing between HV to earth.
(iii) Megger testing between LV to earth.
(iv) Megger testing between HV to LV .
(v) Earth resistance test of transformer neutral.
(vi) Earth resistance test for body earthing. | 1 | Each | 2,000 ₹2,000 | 1,002 ₹1,002 Lowest | 6,500 ₹6,500 | 2,800 ₹2,800 |
| 1.08 | D.O. Fuse :- Cleaning of HT insulators & checking the incoming & outgoing joint connection and testing complete all as specified and directed with the following :-
(i) Megger testing between phase to phase& phase to earth. | 2 | Each | 1,500 ₹3,000 | 852 ₹1,704 Lowest | 1,500 ₹3,000 | 1,500 ₹3,000 |
| 2.00 | M&L for painting of 33 /11 KV MRS switch yard MS structure with one coats of asian make aluminum paint after cleaning and making good surface for panting of the following structure:-
(a) Bus bar Gantry:- Painting of busbar Gantry of MS channel (I Section) size 150 mm x 75 mm x 5.5 mtr long - 12 Nos
(b) Lightening arresters (LA):- Painting of lightening Arresters of MS channel (C-section) of size 100 mm x 50 mm x 3.0 mtr long -02 Nos with MS Angle iron 50x 50 x 2.65 mtr long -02 Nos complete - 03 Job
(c) Line isolator (LI):- Painting Line isolator of MS channel ( C-section) of size (125 mm x 65mm x 2.50 mtr long -04 Nos) and ( 100 mm x 50 mm x 1.00 mtr -03 Nos) with MS flat bracing (50mm x 50mm x 0.30 mtr -6 Nos) and MS Angle iron ( 50 mm x 50 mm x 2.65 mtr long-02 Nos) complete -09 Job
(d) Horn Gap fuse:- All as per item No 2(c) here in before. Qty - 03 Job
(e) Pin insulator supporting structure :- All as per item No 2 (c) here in before. Qty - 03 Job
(f) PT supporting structure :- All as per item No 2 (c) here in before. Qty - 04 Job
(g) VCB / CT stand :- Painting of CT VCB structure made out of MS channel ( C-section) of size ( 65 mm x 65 mm x 1.10 mtr long- 04 Nos) and ( 100 mm x 50 mm x 0.90 mtr long- 03 Nos) and ( 100 mm x 50 mm x 1.90 mtr long- 04 Nos) and Angle iron of size ( 50 mm x 50 mm x 1.10 mtr -04 No) ( 50 mm x 50 mm x 0.70 mtr long- 06 Nos) and (50 mm x 50mm x 0.25 Mtr long - 05 Nos) complete -03 Job complete all as specified and directed. | 1 | Each Job | 30,000 ₹30,000 | 7,515 ₹7,515 | 5,000 ₹5,000 Lowest | 26,000 ₹26,000 |
Tender Value
₹20.4 L
EMD Value
₹40,700
Closing Date
7 Jan 2026, 6:00 pmClosed
CWE (AF) BAREILLY
HQ Commander Works Engineers (AF) Military Engineer Services Bareilly 243002
As described in BOQ
2025_MES_745279_1
81600/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) (AF) MEMAURA
As per NIT
9 documents required · 9 mandatory
₹500
AGE (I) (AF) MEMAURA
₹40,700
27 Feb 2026
19 Dec 2025
15 Jan 2026
19 Dec 2025
7 Jan 2026
2 Jan 2026
M & L for periodical services, cleaning and testing various type equipment 33/11 KV equipments in switch yard and other connected works etc complete as specified and directed for the following :-
Supply only Air break switch spares :-
HT 33 KV Current Transformer (CT) :- Cleaning of bushing and terminal by CTC solution of CT rating 100 / 5 + 5 + 1 Amp rating, 33 KV and checking of oil level, rectify leakages if any and testing the oil strength (BD test) and proper connection checking and testing complete all as specified and directed with following :- (i) Megger testing between phase to phase& phase to earth
HT Potential Transformer (33 KV / 110 Volt) :- Cleaning of bushing and terminal of HT potential transformer 33000 / 110 volts (outdoor type) by CTC liquid and checking of oil level including rectification of any type of leakage and proper connection checking and testing complete all as specified and directed with following :- (i) Megger testing between phase to phase & phase to earth (ii) Checking output voltage (iii) Testing the oil dielectric strength (BD test)
Supply and fixing in replacement of electronic auxillary relay type B24 voltage 24 V DC for 33 KV panel complete all as specified and directed
33 KV VCB Control & Relay Panel :- Cleaning of control & relay panel inside & outside by CTC solution and checking all the control cable connection of CT, PT, VCB, meters, trivector meter transformer complete all as specified and directed.
M & L preparation of old painted external surfaces of HT, 2 pole structures consisting of cross arms, GOD assy with pipe, DO fuse assy, clamps etc. of any description and applying one coat of Aluminium paint by manually complete all as specified and directed.
HT Vacuum Circuit Breaker (VCB) 33 KV :- Cleaning & servicing of HT 33 KV vacuum circuit breaker (VCB) 400/630/1250 Amp, 3 phase, outdoor type, checking of each moving parts, spring, charging system, closing & trip coil assembly and proper oiling, greasing and proper adjustment of trip bars, closing bar complete all as specified and directed with the following testing :- (i) ON/OFF testing in local and remote position. (ii) Spring charge system testing shall be carried out. (iii) Tripping test in over and earth fault position by external current injecting Kit on Primary Secondary side. (iv) Megger testing between phase to phase and phase to earth in ON / OFF position both.
Transformer 33/ 0.433 KV, 100 KVA (Station Transformer) :- Cleaning of station transformer (outdoor type) externally including all accessories and checking of all incoming & outgoing connection and rectify the leakages if any complete all as specified and directed with the following testing :- (i) Transformer oil dielectric strength (BD) test. (ii) Megger testing between HV to earth. (iii) Megger testing between LV to earth. (iv) Megger testing between HV to LV . (v) Earth resistance test of transformer neutral. (vi) Earth resistance test for body earthing.
M&L for painting of 33 /11 KV MRS switch yard MS structure with one coats of asian make aluminum paint after cleaning and making good surface for panting of the following structure:- (a) Bus bar Gantry:- Painting of busbar Gantry of MS channel (I Section) size 150 mm x 75 mm x 5.5 mtr long - 12 Nos (b) Lightening arresters (LA):- Painting of lightening Arresters of MS channel (C-section) of size 100 mm x 50 mm x 3.0 mtr long -02 Nos with MS Angle iron 50x 50 x 2.65 mtr long -02 Nos complete - 03 Job (c) Line isolator (LI):- Painting Line isolator of MS channel ( C-section) of size (125 mm x 65mm x 2.50 mtr long -04 Nos) and ( 100 mm x 50 mm x 1.00 mtr -03 Nos) with MS flat bracing (50mm x 50mm x 0.30 mtr -6 Nos) and MS Angle iron ( 50 mm x 50 mm x 2.65 mtr long-02 Nos) complete -09 Job (d) Horn Gap fuse:- All as per item No 2(c) here in before. Qty - 03 Job (e) Pin insulator supporting structure :- All as per item No 2 (c) here in before. Qty - 03 Job (f) PT supporting structure :- All as per item No 2 (c) here in before. Qty - 04 Job (g) VCB / CT stand :- Painting of CT VCB structure made out of MS channel ( C-section) of size ( 65 mm x 65 mm x 1.10 mtr long- 04 Nos) and ( 100 mm x 50 mm x 0.90 mtr long- 03 Nos) and ( 100 mm x 50 mm x 1.90 mtr long- 04 Nos) and Angle iron of size ( 50 mm x 50 mm x 1.10 mtr -04 No) ( 50 mm x 50 mm x 0.70 mtr long- 06 Nos) and (50 mm x 50mm x 0.25 Mtr long - 05 Nos) complete -03 Job complete all as specified and directed.
M & L for RCC cable duct cover with 8mm dia MS bar as required at site including 12 mm dia MS bar moveable handle both side of cable cover for lifting etc complete all as specified and directed.
Supply and fixing in replacement battery charger suitable for 30 volt as per existing make/model/capacity etc complete all as specified and directed
Supply and fixing in replacement of remote switch suitable for 11 KV HT panel as per existing make/model earth etc complete all as specified and directed.
Supply and fixing in replacement of heater switch suitable for 11 KV HT panel as per existing make/model earth etc complete all as specified and directed.
Supply and fixing in replacement of space heater for VCB suitable for 11 KV HT panel as per existing make/model earth etc complete all as specified and directed.
S&F Ammeter digital type 100A/5A or 60A/5A CTR of 150mm x 150mm including taking out of old unserviceable ammeter complete all as specified and directed.
S&F Voltmeter digital type 15 KV of 110/30 V PTR. Size 150mm x 150mm including taking out old unserviceable voltmeter complete all as specified and directed.
S&F indicator light (LED type) suitable to operate on 30 volts DC/110 V AC having two covers red/green/blue for HT VCB panel including taking down old complete all as specified and directed.
D.O. Fuse :- Cleaning of HT insulators & checking the incoming & outgoing joint connection and testing complete all as specified and directed with the following :- (i) Megger testing between phase to phase& phase to earth.
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n exc. 1.50m deep for HT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed
Returning filling including spreading leveling watering and well ramming in layers not exc 25cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n exc 50m and depositing where directed at a level n exc1.5m above the starting point, complete all as specified and directed.
Servicing and calibration to 11KV HT VCB (SF-6 type) of RMU complete with the following:- (a) Calibration of relay any type/make/model on HT panel (2 Nos over current & 01 No earth fault relay) as per load or as directed by Engr-in-charge and cleaning the contact (NO+NC) by CTC solution and adjust the contact and testing the relay by testing kit etc complete all as specified and directed. (b) Opening the HT panel bus bar and cleaning the bus bar and closed the whole by putty and other material in all respect etc complete all as specified and directed Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately as supply only. (ii) Contractor shall submit the connected test report to Engr-in-charge
Supply and laying un-reinforced precast concrete cable cover, class HV, Type I, flat size 300 mm x 180 mm x 40 mm laid dry for protection of UG cable complete all as specified and directed
Dismantling / Taking out unserviceable HT cables for replacement of any size from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed . (Note : Earth work shall be measured and paid separately)
Supply, laying, jointing and testing of HT XLPE cable 3 core, 11000 volt screened, PVC bedded "Earthed grade" insulated bedded, galvanised steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system confirming to IS-7098(Part-I) 1977 and part-II of 1985 laid in pipe /ducts/trenches, under floor and road or fixed to wall etc complete cross-sectional area of cable 240 sqmm 3 core, all as specified and directed .
M&L for sand cushioning to U/G cable in layers of 23 cm thick ( 8 cm before laying the cable and 15 cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Punned down volume shall be measured.
M & L in replacement of GI tubing light grade for passing through cables under the floor, along the wall or along the pole of 100 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etc including taking down old GI tubing complete all as specified and directed.
Material and labour for lightning arrester 11000 volts non linear resister type conforming to IS-3070 part-I, line discharge class-2, nominal discharge 10 KA and high discharge 65 KA assembly complete suitable for 11 KV including all clamps, nuts, bolts and washers and connecting to earth with 4 mm dia GI wire complete all as specified and directed.
Material and labour for lightening arrester 33000 volts non linear resister type conforming to IS-3070 part-I, line discharge class-2, nominal discharge 10 KA and high discharge 65 KA assembly complete suitable for 33 KV including all clamps, nuts, bolts and washers and connecting to earth with 25x4 mm GI strip complete including dismantling of old lighting arrester etc all as specified and directed.
M&L in replacement of indoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core all as specified and directed.
M&L in replacement of indoor end terminal joints cold shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area 185 Sqmm, 3 Core, all as specified and directed. ( Make : 3M/Denson/Raychem )
M&L in replacement of indoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour for making joints suitable for aluminium conductor cable of cross sectional area 240 Sqmm 3 Core complete all as specified and directed.( Make : 3M/Denson/Raychem)
M&L in replacement of outdoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour for making joints suitable for aluminium conductor cabl
e of cross sectional area 95 Sqmm 3 Core complete all as specified and directed.
M&L in replacement of outdoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour for making joints suitable for aluminium conductor cable of cross sectional area 185 Sqmm 3 Core complete all as specified and directed.
M&L in replacement of outdoor end terminal joints cold shrinkable Suitable for HT 11000V (Earthed), XLPE insulated armoured Heavy duty under ground cable including joint kits and labour for making joints suitable for aluminium conductor cable of cross sectional area 240 Sqmm 3 Core complete all as specified and directed.
M&L in replacement of straight through joints cold shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour for making joints suitable for aluminium conductor cable of cross sectional area 95 Sqmm 3 Core complete all as specified and directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 100 mm bore(dia) for passing UG cable, complete all as specified and as directed. (Note : - GI Pipe laid will be measured and paid separately under appropriate item)
Supply, installation, commissioning and testing of outdoor type switch air break gang operated suitable for horizontal mounting rotating type, HT 33000 volts grade triple pole with 09 insulators, 400 amp capacity current rating complete having post insulator type on channel (two insulator for one phase) mounted on steel frame mechanically operated mechanism from ground level consisting of rod of 25 mm bore GI pipe, light grade of suitable length worked from ground level with locking arrangement fixed with flat iron clamp 50X6 mm and MS channel of suitable size & length for fixing GO/DO including bolts, nuts and washers complete all as specified and directed.
Supply, laying, jointing and testing of HT XLPE cable 3 core, 11000 volt screened, PVC bedded "Earthed grade" insulated bedded, galvanised steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system confirming to IS-7098(Part-I) 1977 and part-II of 1985 laid in pipe /ducts/trenches, under floor and road or fixed to wall etc complete cross-sectional area of cable 95 sqmm 3 core, all as specified and directed
Supply, installation, commissioning and testing of outdoor type switch air break gang operated suitable for vertical mounting rotating type, HT 11000 volts grade triple pole with 09 insulators, 400 amp capacity current rating complete mounted on insulators and steel frame mechanically operated mechanism from ground level consisting of rod of 25 mm bore GI pipe, light grade of suitable length worked from ground level with locking arrangement fixed with flat iron clamp 50X6 mm and MS channel of suitable size & length for fixing GO/DO including bolts, nuts and washers complete all as specified and directed.
Supply and fixing of earth continuity conductor or main earthing lead fixed to wall / pole / roof conductors and down conductors with porcelain insulation above ground with saddles and fixing screws etc. or any other indicated situation as GI strip of size 25x4 mm connected to test point complete all as specified and as directed
Supply and fixing of earth continuity conductor or main earthing lead fixed to wall / pole / roof conductors and down conductors with porcelain insulation above ground with saddles and fixing screws etc. or any other indicated situation as Aluminium strip of size 25x3 mm connected to test point complete all as specified and as directed
Supply & fixing DO fuse assembly, triple pole mounted on porcelain HT insulator 6 Nos and MS galvanised
Supply and filling up of Transformer oil conforming to as per IS:335-1993 in topping up/replacement up to desired level of transformer oil capacity complete all as specified and directed. (Note: Dielectric strength of oil should not be less than 50 KV complete all as specified and directed.)
Supply and replacing silica gel in crystal form of breather assembly of transformer capacity upto 2000 KVA installed at site complete all as specified and directed.
Repair/servicing to transformer at site of capacity 100 to 250 KVA installed on plinth/pole mounted structure by opening top cover & replacing unserviceable spares/components of transformer, without lifting core assembly reassembling after repair & testing complete all as specified and directed.
Repair/servicing to transformer at site of capacity 315 to 500 KVA installed on plinth/floor mounted structure by opening top cover & replacing unserviceable spares/components of transformer, without lifting core assembly reassembling after repair & testing complete all as specified and directed.
Supply only ceramic Bush insulator on LT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 KV transformer complete all as specified and directed.
Supply only cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 KV transformer complete all as specified and directed
Supply only cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification for capacity 200 to 315 KVA, 11/0.433 KV transformer complete all as specified and directed
Supply only ceramic Bush insulator on HT side as per existing size, shape and specification for capacity 200 to 300 KVA, 11/0.433 KV transformer complete all as specified and directed
Supply only top cover gasket as per existing size, shape and specification for capacity 200 KVA, 11/0.433 KV transformer complete all as specified and directed
Supply only top cover gasket as per existing size, shape and specification for capacity 315 to 500 KVA, 11/0.433 KV transformer complete all as specified and directed
Supply only breather assembly as per existing size, shape and specification for capacity 200 KVA, 11/0.433 KV transformer complete all as specified and directed
Supply only breather assembly as per existing size, shape and specification for capacity 315 to 500 KVA, 11/0.433 KV transformer complete all as specified and directed
steel frame rating upto 400 Amp, 11000 Volt, post insulator type on channel (two insulator for one phase) complete with expulsion type fiberglass fuse carrier barrel type and including DO fuse and electrical connections complete all as specified and directed by Engineer-in-Charge.
Dehydration and filtration of existing transformer oil of transformers capacity ranging from 100 KVA to 500 KVA ( 1/0.433 KV ) on site at different locations without disturbing the power supply system with filtration machine and heating systemin order to achieve Di-electric strength of oil 40 KV minimum 2.5 mm gap complete all as specified and as directed. Note : (a) Testing of transformer HT switch gear oil before & after dehydration shall be carried out as directed (b) The unit of payment under this term shall be per litre of oil meant for all process to the entire completion of job.
Servicing of HT (11KV ) switch gear panel, detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, through authorized representative service centre of VCB manufacturer channel partner /OEM or UPPCL approved vendor for VCB repairing agency, Testing for smooth operation manual/ remote after calibration of relay and resetting & generation of testing report by the primary injection set For 11KV VCB for OC/EF, parameter of relay setting including writing of MES No. complete all as specified and directed by Engr-in-Charge. Note: Worn out minor parts shall be deemed to be included in unit rate.
Supply only closing/tripping coil of 11 KV VCB's as per existing make and model complete all as specified and directed.
M&L in replacement of straight through joints cold shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour for making joints suitable for aluminium conductor cable of cross sectional area 240 Sqmm 3 Core complete all as specified and directed.
Supply & fixing in replacement of Current transformer (CT) of 11 KV, single phase indoor type, CT ratio 60/1 Amp, STC 26.3 KA or more for 1 sec, Class PS, Insulation class B complete all as specified and as directed.
Supply & fixing in replacement of Current transformer (CT) of 11 KV, single phase indoor type, CT ratio 200-100/5-5 Amp, STC 26.3 KA or more for 1 sec, Class PS, Insulation class B complete all as specified and as directed.
Supply and installation of 33 KV single phase out door oil cooled CT of ratio 50/1-1 Amp class 1.0 – 5P10 burden 15 VA insulation level 70 KV/170 KV as per IS-2705 complete all as specified and directed.
Supply and installation 33 KV single phase out door oil cooled PT of ratio 33 KV/rt 3/110V/rt 10V/rt 3 Class 0.5-3, Burden 50 VA – 50 VA, insulation level 70/170 KV, voltage factor 1.2 Cont and 1.9 for 30 Sec, conforming to IS-3156 complete all as specified and directed.
Supply and fixing in replacement of electronic 3 phase over current and earth fault (IDMT) relay installed on existing panel or separate enclosure, with connecting, internal control wiring, testing complete all as specified and directed (MAKE :- L&T Model No- MC61A-nX or equivalent )
Supply and fixing in replacement of 3 phase trip circuit supervision relay type VAX MK II installed on existing panel or separate enclosure, with connecting, internal control wiring, testing complete all as specified and directed
Supply and fixing in replacement of electronic auxillary relay type AR114X2 voltage 24 V DC for 33 KV panel complete all as specified and directed
Servicing of HT (33 KV ) panel / VCB, detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, through authorized representative service centre of VCB manufacturer channel partner /OEM or UPPCL approved vendor for VCB repairing agency, Testing for smooth operation manual/ remote after calibration of relay and resetting & generation of testing report by the primary injection set For 33 KV VCB for OC/EF, parameter of relay setting including writing of MES No. complete all as specified and directed by Engr-in-Charge. Note: Worn out minor parts shall be deemed to be included in unit rate.
NOTE Ser item No. 50 to 62:- (i) Tenderer shall be checked the existing VCB's and shall be taken all the details of existing defective one before order the materials. (ii) New items shall be match with the existing system in any cases. (iii) Any minor adjustment /modification for the fixing the item if required at site contractor shall be carried out at site without any extra cost.
Supply & fixing in replacement of Voltage transformer (VT) of rated voltage 11 KV, three phase indoor type, ratio 11000/110 volts, VA/PH : 200, IL : 12/28/75 kVp, class 1, Insulation class B, 50 Hz, complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600x 6 mm thick buried in ground vertically to a depth n.less than 2.25 mtr below normal ground level connected to galvanized steel strip 25 x 4 mm earth lead by means of bolts, nuts and washers made of galavanised iron or steel earth strip protected by 40 mm bore light grade GI pipe and connected for body earthing of feeder pillar box all as specified and directed including PCC work as per sketch No 3 of SSR Part -I (2009) pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel, wire mesh 20 mm dia GI pipe medium grade for watering, charcoal and slat in alternate layers incl necessary earth pole and excavation in hard/dense soil and removal etc including testing complete all as specified and as directed.
M & L for preparation of old painted steel or iron surfaces of transformers of 100 to 500 KVA, 11/0.433 KV capacity transformer by scrapping with steel wire brush /scrapper emery paper etc and applying one coat of synthetic enameled smoke grey/exising colour (painting shall be done by spray machine) including writing of SM No, MES No at prominent place/location of transformer with black synthetic enamel paint in white back ground complete all as specified and as directed.
Material & Labour for single gravel of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
Supply only spring charging motor of 230 volts 0.25 HP, 8000 RPM of 11 KV VCB's type VE -12, 30/110 volts (Make - L&T/ Crompton Greaves or equivalent).
Supply and fixing in repairs relay suitable for earth, overcurrent,differential and buchholz Alarm, Winding & Oil temp alarm suitable for 2 MVA 33/11 KV Transformer as per existing make/model etc complete all as specified and directed.
Detection of pin point fault in HT cable (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator, acoustic fault locator and reflectometer (laptop based) complete all as specified and directed by Engr-in-Charge. Notes- (i) Cable fault locating machine to be arranged at site with in 12 hrs after intimation (ii) Earth work will be measured separately. (iii) Cost of transportation in unit rate is deemed to be included.
Male contact/moving Contact Blade
Female contact/Fix Contact Jaw
Tinned copper Flexible jumper 200A/400 A
MS jumper carrier
Back Connector plate
Repairing / Servicing the Air break isolating switch 11 KV 200/400 Amps by replacing the defective major spares including provn of worn out bolts nuts etc, applying petroleum jelly on moving/ fixed contacts complete all as specified and directed. Note :- Major spare will be measured & priced separately under relevant item of BOQ.
All as per item No 71 here in before but for 4 pole structure complete all as specified and directed.
Supply and fixing in replacement of pin type insulator porcelain vitreous green, brown or white suitable for 11000 Volts grade including one galvanised mild steel spindle two GI washers, one GI nut, bolt and two washers etc of size 150mm height and 150mm dia, complete including dismantling old insulator from position all as specified and directed.
S&F in replacement of Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150 mm dia, Shank dia 25mm or more, min creepage distance 840mm suitable for 33000 volts grade including dismantling old insulator from position complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
81600Tender.pdf
Tender Documents • 1.14 MB
BOQ_834527.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .