Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC 0 SHANKERPURI COLONY SAHARANPUR BEHAT ROAD NEAR DEHAT KOTWALI SAHARANPUR UTTAR PRADESH 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical 100 33 1 R G S ROAD USHAGRAM SALANPUR 713303 WEST BENGAL INDIA | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | 713303 | - | Rejected-Technical As per TCR | |
| 3 | Rejected-Technical DUTTA BAGAN SEN RALEIGH ROAD ASANSOL BARDHAMAN BARDHAMAN 713305 WEST BENGAL INDIA | ASANSOL | BARDHAMAN | WEST BENGAL | 713305 | - | Rejected-Technical As per TCR | |
| 4 | Rejected-Technical | - | Rejected-Technical As per TCR |
Tender Value
₹11.7 L
EMD Value
₹14,700
Closing Date
18 Oct 2024, 5:00 pmClosed
Area Engineer (EandM)
Office of the General Manager Pandaveswar Area , P.O. Pandaveswar, Dist.-Burdwan, West Bengal-713346
Supply, installation, testing and commissioning of NGR in 2 MVA, 33kV/11Kv and 5MVA, 33Kv/6.6Kv Transformer of Khottadih Colliery of under Pandaveswar Area with 3 years CAMC.
2024_ECL_318825_1
GM-PND/EandM/24-25/83/579 dated 07/10/2024
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Khottadih Colliery
Please refer Tender documents.
5 documents required · 5 mandatory
₹14,700
20 Dec 2024
8 Oct 2024
19 Oct 2024
8 Oct 2024
18 Oct 2024
8 Oct 2024
8 Oct 2024 - 11 Oct 2024
Amount
Supply, installation, testing and commissioning of NGR in 2 MVA, 33kV/11Kv and 5MVA, 33Kv/6.6Kv Transformer of Khottadih Colliery of under Pandaveswar Area with 3 years CAMC. (Inclusive of EPF/CMPF)
Supply and Installation of Indoor type Neutral Grounding Resistor to be housed in secondary side of 2MVA, 33KV/11KV Transformer, 50A, 10 Sec Non-magnetic punched stainless steel grid 38.2 ohm + 5%, temperature raise up to 375 degrees complete with failsafe relay, auxiliary wiring, neutral to ground earth via NGR with installation, commissioning & testing with 3 years CAMC.
Supply and Installation of Indoor type Neutral Grounding Resistor to be housed in secondary side of 5MVA, 33KV/6.6KV Transformer, 50A, 10 Sec Non-magnetic punched stainless steel grid 38.2 ohm + 5%, temperature raise up to 375 degrees complete with failsafe relay, auxiliary wiring, neutral to ground earth via NGR with installation, commissioning & testing with 3 years CAMC.
Transporting charges.
P.F. @ 12.72% on Total Labour Cost
Total impact of GST for the purpose of CTC
S P ENTERPRISES
ELECTRO POWER INDUSTRIES
JUBILEE ELECTROMECH WORKS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .