Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹41.4 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹46.2 L+₹4.0 L (9.51%)Rejected-AOC | L-2 | Rejected-AOC Not Being the lowest bidder | |
| 3 | L-3₹48.5 L+₹6.3 L (14.9%)Rejected-AOC | L-3 | Rejected-AOC Not Being the lowest bidder | |
| 4 | L-4₹48.9 L+₹6.7 L (15.9%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-4 | Rejected-AOC Not Being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
6 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
SPECIAL REPAIRS TO TOILET BLOCKS ROOF TREATMENT ENERGY SAVING LED SECURITY LIGHTS AND CERTAIN REVENUE MINOR WORKS AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_359975_2
GE/KC/NIT-29/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹97,000
Yes
15 Oct 2020
15 Sept 2020
8 Oct 2020
15 Sept 2020
6 Oct 2020
24 Sept 2020
15 Sept 2020 - 23 Sept 2020
60 days
Amount
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified & directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet 5mm thick to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplied & fitted in the frame at site as per specification & drawings shown in SSR Part-II, complete as specified & directed.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long, complete all as specified & directed.
Extruded aluminium alloy handle, fabricated type, anodised, 150mm long, complete all as specified & directed.
Butt hinges, medium weight, cold rolled, mild steel 100mm long, complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mmx350mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Angle valves, 15mm bore, fancy type, chromium plated, cast copper alloy with capstan head, screwed down, high pressure, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Machine cut kota stone slab flooring, 20-25 mm thick as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 15mm screed layer in cement mortar 1:4, complete all as specified & directed.
Machine cut kota stone slab, 20-25 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:3, complete all as specified & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
Vitreous china, wash hand basin, flat back, white of size 630mmx450mm including brackets, 32mm dia waste pipe, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
Viterous china urinal, bowl type flat back, size 465x355x265mm (minimum) white with grating and union for discharge pipe, complete including providing and fixing plugs, beding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixed in repairs, complete all as specified & directed.
PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified & directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, fixed in repairs, complete all as specified & directed.
Brass chromium plated shower rose of 125mm size with or without swivel joints, fixed in repairs, complete all as specified & directed.
Chromium plated grating of 100mm size (square/round) cast copper alloy, made in two parts, fixed in floors/tiles with white/coloured cement, fixed in repairs, complete all as specified & directed.
Soap dish, brass chromium plated, of size 100x60mm, fixed to walls with chromium plated screws, fixed in repairs, complete all as specified & directed.
Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls with clamps / floors, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls with clamps / floors, fixed in repairs, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius with oval access door, fixed in repairs, complete all as specified & directed.
75mm bore PVC (SWR) bends any radius with oval access door, fixed in repairs, complete all as specified & directed.
PVC (SWR) vent cowl of size 75mm bore, fixed in repairs, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal with oval access door, 75mm bore, fixed in repairs, complete all as specified.
PVC (SWR) junction single (Single T) equal or unequal with oval access door, 110mm bore, fixed in repairs, complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal with oval access door, 75mm bore, fixed in repairs, complete all as specified & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 25mm bore, complete all as specifed & directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors , complete all as specified and directed.
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors , complete all as specified and directed.
Galvanized iron water tubing, medium grade, 25mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors , complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc. 10cm girth in brick walls, complete all as specified & directed.
Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
Steel ventilator with top hung shutter including hinges, steel peg stay, complete including one shop coat of red oxide zinc crome primer including taking down old unserviceable ventilator, complete all as specified & directed.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
3mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or glazing pins in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
Mild steel galvanised wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or 2nd class soft wood beading etc, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Complete removal of the existing sunken treatment including roughening and preparation old surfaces of concrete floor by picking, scurubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and applying the following treatment :- (a) 15 thick rendering on fair faces of brick work or cement surfaces in cement mortar 1:4 with using integral water proofing compound as per manufacturer instructions by weight of cement to sunken portion including wall of sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement, finishing concrete including walls of sunken portion with proper slope. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. Note : Ponding shall be done in sunken portion area by filling water which shall be kept there for 48 Hours. In case a slightest indication of seepage/leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shall be repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
PCC 1:7:12, nominal mix, type F-2 using 40mm graded crushed stone aggregate as in filling and mass concrete, complete all as specified & directed.
25mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as in floor/ sunken floor etc, complete all as specified and as directed.
Galvanized iron tube as in spout pipe, medium grade, 40mm bore in short length of 45cm, cut to shape required including Cutting/drilling holes through RCC beam/brick wall by mechanical meanexc 300mm deep and making good in cement mortar 1:3, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces using integral water proofing compound, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective item.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in roof padding and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 2000 ltrs including making connections and 25mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 25 mm - 455 gms) and dismantling of old unserviceable water storage tank, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 25mm, fixed in repairs, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
15mm thick rendering in cement mortar 1:6 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified & directed.
5mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
5mm thick rendering in cement mortar 1:4 over 10mm thick rendering in cement mortar 1:6 on brick or concrete surfaces using integral water proofing compound, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective items.
75mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick joints with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand, complete all as specified & directed.
Supply only integral water proofing compound, complete all as specifed & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of cement base paint, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan to any radius, half brick thick walls built in cement mortar 1:4, complete all as specified & directed.
20mm thick Granite (of any type/shade) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:4 complete all as specified & directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipe etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 200mm, complete all as specifed & directed.
Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 200mm, complete all as specified & directed.
Salt-glazed stoneware drain pipe, grade ‘A’ internal dia of pipe 200mm, laid in trenches and jointed, complete all as specified & directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 500 ltrs including making connections and 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms) and dismantling of old unserviceable water storage tank, complete all as specified & directed.
Refixing old steel tubing and connections of 20mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed .
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 20mm, fixed in repairs, complete all as specified & directed.
10mm thick plastering in cement mortar 1:4 on concrete surfaces of chajjaa, upward fascias, and similar items including necessary formwork and scaffolding after making good decayed concrete portion in cement mortar 1:3, height upto 11m, applying two coats of acrylic cementious water proofing coating with dry film total thickness approx 1mm as per manufactureres instructions in patches including taking out old cement plaster, complete all as specified & directed. Make. Dr Fixit 2K of Pidilite or equivelent of Chemistek/ Prime
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint over a coat of primer, complete all as specified.
Complete removal of existing treatment from old decorated plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer over 3mm thick wall care putty, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of ceiling by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads, n exc 1.5 sqm, complete all as specified & directed.
Preparation of old decorated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified & directed.
Preparation of old painted wooden or wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified & directed.
Asbestos 4mm thick E-board (classic) of size 600x600mm laid on and included GI snap grid frame work (Grid size 605x605mm) for false ceiling with powder coated GI angle of size 25x25mm, main runner ‘T’ of size 25 x 40mm, secondary runner ‘T’ of size 25x30mm suspended with 3mm GI wire with butterfly clips for levelling, complete all as specified & directed. Note : 1. Quoted rates are inclusive for making holes, cutting chassis and making good to existing walls in cement mortar 1:3 or PCC 1:2:4 type B-1 as per existing finish all as directed at site. 2. All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Preparation of new ceiling surfaces of asbestos e-board and applying two coats of oil emulsion distemper over a coat of alkali resistant primer, complete all as specified.
Preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer, complete all as specified.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Salt-glazed stoneware drain pipe, grade ‘A’ internal dia of pipe 150mm, laid in trenches and jointed, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Construction of Septic Tank for 25 users including excavation in any type of soil, foundation in PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) brick work in cement mortar 1:4, RCC (M-25 design Mix) slab including cast iron manhole cover having 6mm plate embedded all around with angle iron frame vent shaft etc, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5.
Construction of soakage well 2.40m internal dia and 3.00m depth including excavation in any type of soil, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in footing brick honey comb/ solid brick masonry in cement 1:4, RCC (M-25 design mix) cover slab filled with brick bats including intercepting chamber screen chamber and disposal of soil, complete all as specified and shown on CE Pathankot Zone TD Drawing No CEPZ/C-TD/013/13 Sheet 1 to 5. Note : 1. During excavation if unexpected water is encountered, the same shall be bailed out / de-watered by the contractor mechanically or manually without any extra cost. 2. The excavated surplus soil shall be removed to a distance exceeding 500mtr and not exceeding 1500mtr and deposited where directed by the Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
Excavation over areas not exc. 1.5m deep in any type of soil and getting out, complete all as specified & directed.
PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-2, using 40mm graded crushed stone aggregate as in surface channel and drains including necessary form work, complete all as specified & directed.
Extra for forming fair finished drain or channel 70cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified & directed.
BLANK
Excavation over areas exc. 1.5m but n exc 3.0m deep in any type of soil and getting out, complete all as specified & directed.
Excavation in trenches exc. 1.5m wide and exc 1.5m deep but not exc. 3.0m deep in any type of soil and getting out, complete all as specified & directed.
Hard core of gauge n exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified & directed.
100mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, paving, path etc, complete all as specified & directed.
Preparation of surfaces by making free from all loose particles and applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.20 Kg per Sqm heating to a working temperature of 180° C, complete all as specified & directed.
50mm thick PCC 1:2:4 nominal mix, type B-1 using 20mm graded stone aggregate as in flooring using integral water proofing compound as per manufacturer's instructions, complete all as specified and as directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective item.
15mm thick rendering in cement mortar 1:3 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Forming embankments of soils including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc 1.5m high from base, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 25mm, complete all as specified & directed.
BLANK
Pressed steel frames of size 165mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed.
Mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less 12mm dia, with and including a minimum of 6 bolts and nuts, 4 on bolt plate and 2 on stapple plate, 300mm long, complete all as specified & directed.
Preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match, complete all as specified and directed.
PCC 1:3:6 nominal mix, type C-0 using 12.5mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 450mm, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified & directed.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switche fuse unit, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 138 above but for one 3/5 pin 5 Amps socket outlet on same board.
All as per Srl item No. 138 above but for one 3/5 pin 5 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
Inverter LED lamp 6500K, 900lm in white colour of 9 watt, base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed. Make: Philips Cat Part No: BN021CLED20SPSUCWGRS2/ C&S Cat Part No:LTTB4F20WLED/W / Halonix Cat Part No: HLB-03-20-CW-AL/ Havells Cat Part No: LUMILINEPLUSBS20WLED865SPCSS/ Crompton CAT Part No: LDL-36-CDL
Factory made epoxy powder coated distribution board, SPN, 12 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed . Make : Legrand Cat Part No 507622/ Schneider Cat No A9HSND12 or equivalent model of ABB/ C&S
Sheet metal enclosures single pole and neutral enclosure with a two pin and earth plug with socket complete with one double pole MCB 20 Amps, C series, 240 volts, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
MCB, single pole & neutral, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4.00 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 900 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site, complete all as specified & directed. Make. Havells, Cat Part No.Turbo Force SP or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Supply, installation and testing of water heater storage type (Geyser) single phase, 230V, 50Hz, 5 star energy saving, high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 50 Litre capacity, 2000 Watt rated power, incoloy 800 glass coated heating element, tank coating of feroglass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up fixed to walls by drilling of holes, grouting of bolts of suitable size with nuts etc and making good disturbed surface including taking down old unserviceable geyser, complete all as specified & directed. Make. HAVELLS Model No: Monza DX, Cat Part No. GHWAMGSWH050 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Cutting & screwing of existing water supply line of 15mm bore for alterations or additions (or lengthening screw on pipe to form connector) including testing after completion, complete all as specified & directed.
Stop/angle valves, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule,complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
PVC insulated twin core 2.50 sqmm (nominal area) aluminium conductor cable, 1100 volts grade, drawn in & including PVC conduit of suitable size with clamps (3 Nos), nuts, bolts etc from junction box to street light connection, complete all as specified & directed.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Pole mounted distribution box powder coated for street light made of CRCA sheet of 3mm thick, dust and vermin proof, outdoor type of size 300mm x 260mm x 165mm with arrangement of incoming and outgoing feeder comprising of TPN aluminium bus bar of capacity 32 Amp 415 volts, single MCB SP, 230 V, 10 Amp 10 KA (in accordance with IS/IEC 60898-1), fixed on porcelain insulators, making holes on strips for connecting cables, fixed to street light pole with and including 2 Nos MS clamps made of FI 25x5mm with nut, bolt & washer duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer , complete all as specified & directed. Note : Wiring from DB to light fitting shall be measured & paid saperately under respective item of Sch 'A'.
Intergral LED security light luminaire 90W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy 110 lumens per watt including 10 KV surge protection device, mounted on GI bracket and making connection with PVC copper conductor cable of appropriate size, complete all as specified & directed. Make. Crompton Greaves : Cat Part No. LSTP-90-CDL-M or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Street light bracket made out of 40mm bore medium grade pipe of 1.50m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Supply, installation and testing of water heater storage type (Geyser) single phase, 230V, 50Hz, 5 star energy saving, high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000 Watt rated power, incoloy 800 glass coated heating element, tank coating of ferro glass dry powder tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up fixed to walls by drilling of holes, grouting of bolts of suitable size with nuts etc and making good disturbed surface, complete all as specified & directed. Make. HAVELLS Model No: Monza DX, Cat Part No. GHWAMGTWH025 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Supply, installation & commissioning in complete form as a single unit Split type air conditioner (Outdoor / Indoor units & their installation) complete with cooling and heating system to maintain the temperature for huming comfort including necessary plumbing, ducting and staging platform or stand for housing main unit with LCD wireless remote controller, electric driven, single phase of capacity 1.5 tonne, 5 Star BEE rating, complete with all accessories and fittings, complete all as specified & directed. Make. LG/ Samsung/ Bluestar/ Godrej
Supply, installation, commissioning and testing of voltage stabiliser fully automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 140 volts to 280 volts with output voltage stabilised at 220 volts ( ± 9.0 %), calibration accuracy ± 3% and speed of correction 8 volts per second of capacity 5 KVA with short circuit, over current earth fault and high voltage protection, complete all as specified & directed
Factory made epoxy powder coated distribution board vertical type, TPN, 4 ways with metal door (IP-43 protection) confirming to IS : 8623, fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar, cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one MCCB 160/250 Amp 4P as incomer and MCBs SP/TP as outgoing, complete all as specified & . Make: C&S Cat No. CSDBMCCB100DD04IP43S/ Schneider Cat Part No. A9HVD04L or equivalent model of Siemens/ ABB/ Legrand
MCCB of capacity 125 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, ATM (Thermal magnetic release), adjustable overload 80-100%, adjustable short circuit 5-10 In, complete all as specified & directed. Make. C&S Electric Cat Part No.CS31M125ATM4P or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Galvanised steel wire of 4mm dia drawn straight horizontal as continuous earth wire laid in trenches, terminated to steel pole with suitable nuts & bolts, complete all as specified & directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth strip 32x6mm size by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Air termination single pointed copper rod 12mm dia and 300mm long including necessary fixing arrangements using MS clamps, nuts, bolts etc, complete all as specified & directed.
Earthing complete with copper earth plate electrode size 600mm x 600mm x 3.15mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to copper earth strip 20x3mm size by means of bolts, nuts, check nut and washer of copper including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Copper strip 20 x 3mm fixed on suitable size porcelain insulator and screws/ nuts/ washers for roof conductors and down conductors above ground, complete all as specified & directed.
Galvanized iron water tubing, medium grade, 40mm bore for installation of air termination rod, complete all as specified and directed.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in blocks and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw, complete all as specified & directed.
Supply, installation, testing and commissioning of outdoor, cubical type LT panel board suitable for 3 phase 4 wire, 415 Volts, 50 Hz supply system factory made out of 3.15 mm thick CRCA sheet with front and rear openable door provided with suitable gasket to make dust / vermin proof for IP-54 as per IS:13947 degree of protection, fault rating 50 KA / 1 Sec including angle iron base frame of size 50 x 50 x 6 mm thick for mounting the panel board at a height of 600 mm from FFL and 300 mm grouted in PCC foundation of PCC 1:3:6 type C1 using 20mm aggregate, size of PCC foundation should be not less than (0.3 x 0.3 x 0.45 metre) for each leg complete all as specified, directed and comprising of the following:-
INCOMING (i) Incomer MCCB 200 Amp each four pole Icu = Ics = 35 KA MCCB of (Encapsulated roto operated double break contact design) (Uimp = 8KV), lcs = 100%Icu MCCB with thermal magnetic based release having adjustable O/L (70% - 100%), S/C (Isd 1.5 - 10 x lr), neutral protection at N/2, N & MCCB shall have voltage & current metering, extended rotary handle etc. - 1 No (ii) Digital LED voltmeter, 3 phase, class 0.5 - 01 No. (iii) Digital LED ammeter, 3 phase, class 0.5 - 01 No. (iv) 3 Nos resin cast CTs of 200/5A class 1.0 accuracy and 15 VA burden - 1 Set (v) 3 Nos Phase indication LED lamps with 2 Amps back up MCB breaker ON indicating light with MCB, test terminal block set, fuses / MCBs circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required - 1 Set
BUS BAR : (vi) TPN copper bus bar (having 50% Neutral) of minimum of 320 Amps, capacity with heat shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals for complete cross section etc. for withstanding fault level of 50 KA for 1 Sec - 1 Set (vii) MCCB 100 Amps, each four pole Icu = Ics - 25 KA (Encapsulated roto operated double break contact design) (Uimp = 8 KV), Ics = 100% Icu MCCB with thermal magnetic based release having adjustable O/L (70% - 100%) S/C (Isd 1.5 - 10 x Ir), neutral protection at N/2,N & MCCB shall have voltage & current metering, extended rotary handle etc - 2 Nos (vii) MCCB 63 Amps, each four pole Icu = Ics = 25 KA (Encapsulated roto operated double break contact design) (Uimp = 8 KV), Ics = 100% Icu MCCB withthermal magnetic based release having adjustable O/L (70% - 100%) S/C (Isd 1.5 - 10 Ir), neutral protection at N/2,N & MCCB shall have voltage & current metering, extended rotary handle etc. - 2 Nos
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Cutting of road for passing cable through roads including resurfacing of disturbed road surface with premixed carpet, WBM etc of existing specifications to match with original, complete all as specified and directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in this item.
Supply, installation, commissioning and testing of 3 HP rated monoblock pumping set, common base with 2 pole 3000 RPM (Synchronous Speed Max) totally enclosed fan, cooled squirrel cage induction motor suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply, capable of discharging about 455-150 LPM against head of 15 Mts to 27 mts respectively, suitable for 50x40mm size suction and discharge line connection including construction of foundation of 1200x600x200mm size using PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as per manufacturers instructions, complete all as specified & directed. Make : Crompton Greaves/ Kirloskar/ KSB/ CRI Note : All testing arrangement of pumpset should be made avalible by contractors for which rates deemed to be included in quoted rate.
Stop valve, cast copper alloy, 40mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Stop valve, cast copper alloy, 50mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Foot valve, 50mm bore, conforming to IS:4038, complete all as specifed & directed.
Galvanized iron water tubing, medium grade, 40mm bore, screwed & socket joints with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., laid in trenches including clamps connection, cutting, screwing, drilling etc, complete all as specified and directed. Note : (a) Excavation & earth work shall be mesaured & paid for seperately under respective items. (b) Unions of suitable size will be provided at all branches, tee joints at a maximum distance of 30M of straight pipe and its cost are deemed to be included in the quoted rates for this item.
Galvanized iron water tubing, medium grade, 50mm bore, screwed & socket joints with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., laid in trenches including clamps connection, cutting, screwing, drilling etc, complete all as specified and directed. Note : (a) Excavation & earth work shall be mesaured & paid for seperately under respective items. (b) Unions of suitable size will be provided at all branches, tee joints at a maximum distance of 30M of straight pipe and its cost are deemed to be included in the quoted rates for this item.
Sub main wiring using uniform coding of wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC surface conduit of 25mm size as required, fixed on wall/ceiling surface including all fittings and fixing accessories & one run of 4.00 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour and taking down old unserviceable sub main wiring, complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC conduit of 25mm size will be measured and paid as one unit only.
OUTGOING (vi) Power contactor, 12 Amp, 3 pole - 2 Nos. (vii) Over load relay, 4.5-7.5 Amp - 01 No (viii) MCB, single pole, 6 Amp, AC, 10 KA repturing capacity, 240 Volt, 'D' curve - 02 Nos (ix) LED indication lamps for ON & OFF indications - 04 Nos. (x) Push buttons for Start & Stop - 04 Nos.
Taking up cast iron water mains of size 150mm dia (including all fittings) with spigot and socket ends or flanged ends and lead joints including burning out joints and recovering lead, complete all as specified & directed.
Run lead joints to spigot and socket pipes (water mains) and pipe fittings of 150mm bore of pipe, complete all as specified & directed.
Run lead joints to spigot and socket pipes (water mains) and pipe fittings of 80mm bore of pipe, complete all as specified & directed.
Cast iron fittings such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto bore of pipe 150mm, complete all as specified & directed.
Brick masonry valve pit of size 900x900x900mm (internal dimension) with earth work in any type of soil, PCC 1:4:8 type D-2 as in foundation, brick work in cement mortar 1:4, 23cm thick, 15mm thick plaster in cement mortar 1:4 internally and externally flush pointed in same mortar as the work proceeds, flooring shall be 40mm thick in PCC 1:2:4 (Nominal mix) type B-2 laid over 75mm thick hard core, top cover shall be made out of MS sheet of 3mm thickness fixed in angle iron frame made out of angle size 40x40x6mm with 12mm dia handle & two number of hinges on one side and locking arrangement at other side complete including painting with two coats of sythetic enamel paint over a coat of red oxide primer, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Relaying of serviceable CI/DI pipes with fittings of 150mm bore retrived from Srl item No. 193 here-in-before on same or new location, complete all as specified & directed.
M/S GHUMAN BUILDERS
M/S Sudagar Mal
NARESH KUMAR AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .