Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹36.4 L+₹11.8 L (48.0%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Other Than L1 | |
| 3 | Rejected-Technical BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | - | Rejected-Technical Due to banned for issue of tender for not deposit of FDR by GE (AF) Leh |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
30 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
MAINT /REPLACEMENT OF HEATING SYSTEM ACCESSORIES AT CERTAIN AREAS UNDER AGE E/M-II OF GE 865 EWS AT LEH
2023_MES_598226_1
138WE/L-29/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.1 L
Yes
22 Aug 2023
26 May 2023
7 Jul 2023
26 May 2023
30 Jun 2023
16 Jun 2023
Amount
M&L for replacement of Cast iron Butterfly valve of size 80mm dia Class PN 1.6 with SG Iron Dice flanged ends (integrally cast) horizontal type, conforming to IS-14846 (ISI marked) with stainless steel spindle and iron wheel non rising type including jointing material complete such as rubber or fibre board insertion packing rings with requisite numbers of nuts, bolts & washers etc including taking out existing unserviceable valve complete all as specified and directed.
M&L for replacement of Cast iron Butterfly valve of size 100mm dia Class PN 1.6 with SG Iron Dice flanged ends (integrally cast) horizontal type, conforming to IS-14846 (ISI marked) with stainless steel spindle and iron wheel non rising type including jointing material complete such as rubber or fibre board insertion packing rings with requisite numbers of nuts, bolts & washers etc including taking out existing unserviceable valve complete all as specified and directed.
M&L for replacement of Cast iron Butterfly valve of size 150mm dia Class PN 1.6 with SG Iron Dice flanged ends (integrally cast) horizontal type, conforming to IS-14846 (ISI marked) with stainless steel spindle and iron wheel non rising type including jointing material complete such as rubber or fibre board insertion packing rings with requisite numbers of nuts, bolts & washers etc including taking out existing unserviceable valve complete all as specified and directed.
M&L for replacement of Cast iron sluice valve of size 200 mm dia with CI drilled flanged ends (integrally cast)class PN-I.6 horizontal type, conforming to IS-14846 (ISI marked) with stainless steel spindle and iron wheel non rising type including jointing material complete such as rubber or fibre board insertion packing rings with requisite numbers of nuts, bolts & washers etc including taking out existing unserviceable valve complete all as specified and directed.
Material and labour for replacement of old unserviceable centrifugal motor 3 phase 415 volts of capacity 7.5 HP with Mechanical seal complete fittings with accessories , complete all as specified and directed by Engr-in-Charge.
Material and labour for replacement of old unserviceable centrifugal monoblock pump KDI-515+ 3 phase 415 volts of capacity 5 HP with Mechanical seal complete fittings with accessories , complete all as specified and directed by Engr-in-Charge.
Material and labour for replacement of old unserviceable centrifugal monoblock pump 3 phase 415 volts of capacity 3 HP with Mechanical seal complete fittings with accessories , complete all as specified and directed by Engr-in-Charge.
Supply and fixing and replacement of Chilled/Hot Water wall mounting indoor type Fan Coil Unit 600 /1.5TR (CFM/TR) Capacity incl 02 Nos of 20mm valve with stainer (inlet&outlet) incl heavy duty PVC pipe for connection complete all as specified and directed by Engr-In-Charge. (Note : Old Unserviceable wall mounting fan coil unit to be deposited in MES Store Yard)
Supply and fixing and replacement of Chilled/Hot Water Fan coil Unit (FCU) vertical type Floor Mounting 1.5TR (CFM/TR) Capacity complete all as specified and directed by Engr-In-Charge. (Note : Old Unserviceable wall mounting fan coil unit to be deposited in MES Store Yard)
Supply and fixing in replacement of wall mounting (ECO Panel) Convector heater 2.5KW/Hrs Two heat output setup with auto control and LED temperature display. Diemension-Width 1200mm, height, 450mm depth 90mm with complete fixing accessories all as specified and directed by Engr-in-Charge. (Note : Old Unserviceable converter heater to be deposited in MES Store Yard)
S&F in replacement of Radiator coil for 100000 Kcal/Hr capacity Hot water generator not classified under Indian Boiler Act 2023 as per existing shape size & dimensions as per manufacturers recommendation all as specified and directed by Engr-in-Charge.
S&F in replacement of Radiator coil for 300000 Kcal/Hr capacity Hot water generator not classified under Indian Boiler Act 2023 as per existing shape size & dimensions as per manufacturers recommendation all as specified and directed by Engr-in-Charge..
S&F in replacement of Radiator coil for 400000 Kcal/Hr capacity Hot water generator not classified under Indian Boiler Act 2023 as per existing shape size & dimensions as per manufacturers recommendation all as specified and directed by Engr-in-Charge..
S&F in replacement of Burner Assembly including fixing the assembly in the existing Hot water Boiler incl making necessary arrangments with all required fixing materials and made functional the Hot water Boiler of Capacity 1.0/1.5 LKCal/Hr and testing after completetion complete all as directed by the Engr-in-charge.
S&F in replacement of Burner Assembly including fixing the assembly in the existing Hot water Boiler/stand alone CHS incl making necessary arrangments with all required fixing materials and made functional the Hot water Boiler/Stand Alone CHS of Capacity 0.5/0.35 LKCal/Hr and testing after completetion complete all as directed by the Engr-in-charge.
Taking out the unservicable insulation from existing pipe of size 150mm bore of pipe and providing for Insulation of MS Pipe with PUF slab 40 mm thick and applying bituminuous compound and GI cladding with 26 gauge GI sheet complete including complete earthwork for clearance around the pipe compete all as specifid and as directed by Engr-in-Charge.
Ditto as per item No.16 above but of size 100mm all as specifid and as directed by Engr-in-Charge.
Ditto as per item No.16 above but of size 50mm all as specifid and as directed by Engr-in-Charge.
Ditto as per item No.16 above but of size 40mm all as specifid and as directed by Engr-in-Charge.
Ditto as per item No.16 above but of size 32mm all as specifid and as directed by Engr-in-Charge.
Ditto as per item No.16 above but of size 25mm all as specifid and as directed by Engr-in-Charge.
Ditto as per item No.16 above but of size 20mm all as specifid and as directed by Engr-in-Charge.
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .